Sensor SKU: 5906660327714 (IP30)
Sensor SKU: 5905309600713 (IP67)
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.
- Device monitor state of relays or reed switches (1 channel for input)
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 1 minutes to 18 hours (configurable by the user)
- Measurement sending interval: 5 minutes to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Sensor's configuration can be changed remotely from the cloud or with a mobile application over Bluetooth Low Energy
- Operating temperature: -35…+70 °C
- Case IP30 protection (IP67 on request)
Designed to monitor electrical, gas, and water meters, as well as other measurement devices that have a dry contact pulse output feature. This device, belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.
- Maximum pulse frequency: 25 Hz
- Minimum pulse width: 10 ms
- Minimum interval between pulses: 30 ms
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Data encryption
- Supply: 1 x AA battery
- Battery lifetime (20 °C): up to 10 years
- Operating temperature: -40...+60 °C
- Protection class: IP67
Broadsens edge-computing wireless gateways connect and control multiple wireless low-power sensors such as SVT200-A, SVT300-A, SVT400-A, SVT200-V, SVT300-V and SVT400-V.
BroadVibra software is installed inside the wireless gateway. The software has intuitive interface and can be accessed from all major web browsers remotely. The software is ideal for predictive maintenance and conditional based monitoring.
- Communication with sensor: 2.4GHz BLE
- Up to 190 sensors supported
- Network interface: Ethernet, Wi-Fi 802.11ac wireless
- Communication protocol: MQTT, TCP/IP, UDP, Modbus TCP & RTU (RS-485), OPC UA
- Integrated Database: 64 / 128 GB
- Notifications and alarms sent by email (SMTP)
- Vibration analysis: Velocity, RMS, True peak, Peak-peak, STD, Crest factor, Kurtosis, trend analysis, FFT analysis, advanced filtering, frequency fine tuning, trigger modes
- Working environment: -30...+60 °C, 10...90 %RH
- Additional features: 2nd power connector, 2 x GPIO ports (input or output, see manual)
The LoRa-Log-Vape system, using LoRaWAN communication technology, is designed for detecting "vaping" and cigarette smoke. Sensors capture environmental parameters and, upon detecting an event, send a notification to the LoRaWAN receiver (gateway). The data is collected and processed in the receiver and can be viewed on a web page.
The LoRa-Log-Vape registration system consists of a wireless LoRaWAN sensor receiver and wireless Synetica “vape” sensors ENL-IAQ-Vape.
- G2-P pulse counter converts wired consumption meter into a wireless meter
- Types of devices: water, electricity, HCA, room sensor devices, etc.
- Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
- Modes: configurable C, T, or S
- AES-128 encryption mode 5, profile A
- Value format: 0,001...10000 / pulse (configurable). Unconverted dimensionless value
- The total number of pulses is sent periodically
- It is possible to count pulses from two devices simultaneously
- Pulses from the electricity meter LEDs can also be counted using an optical probe (only one optical probe can be mounted)
- Transmission interval: configurable 60 s…1 hour
- Tamper protection
- Operating temperature: -30…+85 °C none condensing (recommended +5…+50 °C)
- Power supply: AA battery 3.6 V Li-SOCI2
- Battery lifetime up to 14 years, depends on configuration and operating temperature
- Measurement object: concentration of particulate matter (PM) in the air PM1.0, PM2.5 or PM10
- Measurement range: 0…1000 µg/m3
- Resolution: 1 µg/m3
- Accuracy: ± 10 %
- Measured data is sent wirelessly to Aranet Pro base station* and if needed to Aranet cloud*
- Signal line of sight range: up to 3 km
- Data transmission interval: 1, 2, 5 or 10 minutes
- Protection: IP42
- Operating temperature and humidity: -10…+60 °C; 0…95 % RH
- Power supply: 12…24 VDC
High-precision sensors in a pre-assembled enclosure box, designed to measure pH in irrigation water for horticulture. This device, belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.
- pH level measurement range: 0…14
- pH sensor operating temperature: 0…+60 °C
- Wireless data transmission and grid-powered
- Kit contains: 4…20 mA transmitter with 24 VDC PSU, Glass pH probe, pH 4…20 mA module
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- For more accurate measuring use sensor in combination with Horticulture Drainage sensor
- For proper use see user manual
Sensor SKU: 5905309601659 (IP30)
Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.
- Device can be used to detect every single movement (act as a regular motion sensor used in alarm systems) or count the number of detected movements in the set time periods in order to detect the room occupancy
- Detection distance: 12 m
- Field of view: 40° x 105°
- Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
- Possibility to integrate sensor to other third-party systems
- Operating temperature / humidity: -35…+70 °C / 0…99 %
- Case IP30 protection
Sensor SKU: 5906660327950 (IP30)
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud** platform or any other third party systems.
- Device can be used to detect every single movement (act as a regular motion sensor used in alarm systems) or count the number of detected movements in the set time periods in order to detect the room occupancy
- Detection distance: 12 m
- Field of view: 40° x 105°
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 1 minutes to 18 hours (configurable by the user)
- Measurement sending interval: 5 minutes to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Possibility to integrate sensor to other third-party systems
- Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
- Case IP30 protection
Radon gas is tasteless, odorless, and hard to detect, posing serious health risks. It escapes from the ground into the air and can accumulate in your home. Radon is a radioactive element, and higher concentrations entering the lungs can cause cancer. Since its levels can fluctuate regular radon monitoring is vital.
- Radon measurement range: 0…4000 Bq/m3
- Temperature measurement range: 0...+50 °C
- Humidity measurement range: 0...99 %
- Pressure measurement range: 600...1100 hPa
- Operational range (in line-of-sight): up to 3 km*
- Bluetooth Low Energy connection with smartphone (Android or iOS) using Aranet Home mobile app
- Supply: 2 x AA batteries
- Battery lifetime (20 °C): up to 7 years (see datashet)
- E-Ink display for longer battery life
- Operating temperature: 0...+50 °C
- Protection class: IP20
Aranet Rain and Precipitation sensor kit is specifically designed for outdoor monitoring of rain and precipitation. This versatile kit finds applications in agriculture for irrigation and soil moisture management, weather stations, water treatment plants, and more.
- The rain gauge is made of ASA (Acrylonitrile Styrene Acrylate) material which is resistant to sunlight (UV), heat and cold
- Protection against birds (spines) and leaves (mesh)
- Measurement accuracy: ± 2%
- Measurements may be given in units of volume such as liters, milliliters, gallons, or expressed in millimeters per square meter
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Supply (impulse counter): 1 x AA battery
- Battery lifetime (20 °C): up to 10 years
- Operating temperature (pulse counter): -40...+60 °C
- The rain gauge operates from +0 °C as it does not have a warming mechanism
- Protection class (pulse counter): IP68
- Included: rain gauge and wireless pulse counter TDSPIC02.010
- Input: external digital I2C probe for temperature, humidity and dew point (sensor are not included)
- Temperature measurement range and accuracy: according to the connected probe
- Humidity measurement range and accuracy: according to the connected probe
- GSM (GPRS) modem, (SIM card are not included)
- Measured values can be sent to the internet storage COMET Cloud
- SMS and JSON messages can be sent via GPRS data connection
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Calibration certificate of manufacturer included
- Data can be transferred to PC via USB-C interface
- Ambient temperature: -20...+60 °C
- Supply: Li-Ion battery A8200, 3.6 V / 5200 mAh
- Protection class: IP67
- Warranty: 3 years
Aranet T/RH sensor with Radiation Shield is an innovative solution for accurate temperature and humidity measurements in greenhouses exposed to direct sunlight.
- Sensor compatible with base stations: PRO, PRO Plus ir PRO Plus LTE
- Temperature measurement range: -40...+60 °C
- Accuracy: ± 0.3 °C
- Relative humidity measurement range: 0…100 %
- Accuracy: ± 2 %
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Supply: 1xAA battery
- Battery lifetime (20 °C): up to 10 years
- Transmitter operating temperature: -40…+60 °C
- Transmitter protection class: IP65
The sensor SVT200-T require to be used with Broadsens's wireless gateway and analysis software BroadVibra.
- Temperature measurement range: -40…+105 °C
- Accuracy / Resolution: ±0,3 °C / 0,01 °C
- Measurement and transmission interval: 15 seconds (Selectable: 1…60 s)
- Power supply: CR2450W Battery. Up to 10 years in continuous usage
- Wireless data transmission (BLE): 2.4GHz; up to 100 m in line of sight
- Certificates: FCC, IC, CE(EU), TELEC, KCC, NCC, WPC, RCM certified
- Mounting: Glue / epoxy. Screw mounting option available for SVT200-T-F case
- Protection class: IP68 waterproof
- Size / Weight: 39 mm x 14 mm / 30 g
Wireless, battery powered temperature sensor with 4 probes. Internal OLED screen for reading local measurements.
- Sensor compatible with base stations: PRO, PRO Plus ir PRO Plus LTE
- Probe compatibility: 2-wire Pt1000 (any class)
- Possible temperature measurement range: -200...+600 °C
- Connection plug: M8 A-code connector with locking nut
- Included probe specifications:
- Temperature measurement range: -30…+180 °C
- Probe dimensions: 6×100 mm (V4A stainless steel)
- Cable insulation material / length: silicone / 5 m
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Data encryption
- Supply: 2xAA alkaline batteries
- Battery lifetime (20 °C): up to 10 years
- Transmitter operating temperature: -40…+60 °C
- Transmitter protection class: IP65
- Packaging includes: 2xAA batteries, 4 pcs temperature probes
The sensor SVT300-V require to be used with Broadsens's wireless gateway and advanced vibration analysis software BroadVibra.
- Alarm sent out in 0,5 second when accident detected
- Acceleration range: 2g to 16g auto adjustment
- Acceleration sampling rate: Low speed & 6.4kHz sampling rate dynamic adjustment based on vibration level
- Acceleration resolution: 16 bit
- -3dB bandwidth (Hz): x,y,z axis: 0.1Hz to 3.2kHz
- Temperature measurement range: -40…+125 °C
- Wireless data transmission (BLE): 2.4GHz; up to 300 m in open space. FCC / IC approved
- Battery life: 3…4 (12-hour running machine a day); 14250 battery, 1200 mAh
- Mounting: M6 screw hole or two screw-hole case
- Working temperature: -55…+85 °C; IP68 (IP69K optional)
- Explosive atmosphere: Intrinsic safe. ATEX & IECEx: Ex ia IIC T4 Ga; Ex ia IIIC T135 Da
Power network meter N100 for electric quality to measurements parameters 3 and 4-wire, 3-phase, balanced or unbalanced power network systems with data logging.
The measurement of: values of voltage and current, active, reactive and apparent power, active, reactive energy, power factors, frequency, up to 51st THD.
- Two-color LED display
- Backlit units of all measured quantities
- Configurable analog and alarm outputs
- Digital RS-485 interface, MODBUS
- Archiving data in the internal memory file system memory 8 GB
- Ethernet interface, protocol: MODBUS TCP/IP, HTTP, FTP
- services: www server, ftp server, DHCP client
- The innovative multiple sensing head interface, which can support up to 8 individually addressable heads per communication box
- reduces sensor cost, simplifies sensor installation and applications troubleshooting, and provides the lowest cost per measurement point
- Temperature measurement range: -40...+2250 °C (different versions)
- Advanced signal processing
- Wide choice of focus distances
- Durable stainless steel IP64 enclosures designed to withstand ambient temperatures from -20 to 85 °C
- Integrated laser sighting
- Galvanic isolated outputs
- Plastic lens option for food application
- Analog input for ambient compensation and adjusting emissivity setting
- USB for easy setup
- Simple, two-wire or digital installation
- Backward compatibility to old Raytek and Ircon in class sensors and accessories
- Real-time thermal line-scanner system for continuous or discrete process measurements
- Up to 1024 measurement points per line
- Fast scan rates up to 150 lines per second (real-time 150 Hz thermal imaging)
- Optical resolution up to 200:1
- Built-in line laser for rapid alignment
- On-board Ethernet TCP/IP communication
- PC independent alarm output
- PC independent 4...20 mA interfaces (3 outputs)
- Wide choice of models and spectral responses
- Rugged, waterproof IP65 enclosure
- Water cooling for ambient temperature up to 180 °C
Contactless counter Colibri 490. With a magnetic drive, activates when a magnet or piece of iron move nearby.
- Display 6-digit, 4mm
- Protection class IP66
- Measurement range: 32…43 °C
- Measurement accuracy: ± 0,3 °C
- Measurement distance: 0…5 cm
- Measurement duration: 1 s
- Measurement location: forehead
- Automatic shut-down: 30 s
- Measurements: 149 x 38 x 42 mm
- Operating temperature: 10…40 °C
- Operating humidity: ≤ 85 %
- Certificates: ISO13485, CE, CFDA
- Supply: 2 x AAA batteries
- PAR measurement range: 0...4000 μmol/s/m2 PPFD
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Data encryption
- Supply: 1 x AA battery
- Battery lifetime (20 °C): up to 5 years
- Operating temperature: -20...55 °C
- Protection class: IP68
- Supplies and controls NAMUR sensors (1 or 2 channels)
- Relay or transistor output
- Output voltage: 9,2 VDC
- High frequency switching (up to 2 kHz)
- DIN rail-mounted
- LED indication
- Supply: 24 VDC / 230 VAC
- Operating temperature: -20...60 °C
- Protection class: IP20
High-frequency contrast sensors for UV, VIS and IR range.
- CO2 concentration measurement range: 0...10 000 ppm
- Output: 4...20 mA
- Programmable
- External probe cable length: 1 / 2 / 4 m
- LCD display
- Calibration certificate included
- Ambient temperature: -30...+80 °C
- Supply: 9...30 VDC
- Protection class: IP65
- Warranty: 3 years
Interior protection from flooding sensor CZP-103R, designed for protection of various rooms (workshops, servers, communication modules, etc.) against flooding. The sensor activates when there is water between its electrodes. Can be used in drainages and rainfall wells for protection against basement flooding. LED indication.
- Flood protection
- Alarm and control
- Supply 12...24 VDC
- Isolated ~5 V electrode supply
- Low energy consumption
- Size 19 mm x 66 mm
Fluid level electrode probes SKC-201, designed to control conductive fluid level in open and pressure tanks. Electrodes – rod or flexible (rope with plastic coating). Probe head is made of acid-resistant steel. Maximal electrode count – 3. Insulation is made out of high quality plastic, enabling the probe to be used in food industry. Standard version probes are coated with plastic (FEP, PU, PVDF), lowering the residue collection (slime, carbonate, foam, etc.). Two modifications are available – with connection cable (P) and connector (G).
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- Stable long-life metal-oxide gas sensor
- Range 0....1000 ppm NH3
- Resolution 1 ppm NH3
- Default alarms at 25 ppm / 35 ppm NH3
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Electrochemical gas sensor
- Range: 0...100, 0...300, 0...1000, (0...10000 on request) ppm NH3
- Resolution: 1 / 2 / 5 ppm NH3
- Sensor lifetime: > 2 years
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -10...+50 °C
- Supply: 11..30 VDC / 24 VAC or 90...265 VAC
- Metal-oxide gas sensor
- Range: 0...1000 ppm NH3
- Resolution: 1 ppm NH3
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+50 °C / 15...90 %RH
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- NDIR gas sensor
- Range: 0...50 000 ppm CO2 (up to 100 % CO2 on request)
- Resolution: 0.01 % vol.
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -25…+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Electrochemical (CO) and optical NDIR (CO2) gas sensors
- Range: 0...100 ppm CO, 0...10000 ppm CO2
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Operating temperature: -20...+50 °C
- Supply: 24 VDC/VAC
- Protection class: IP65
- Electrochemical gas sensors
- Range: 0...100 ppm CO, 0...20 ppm NO2
- Resolution: 1 ppm CO, 0,1 NO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Operating temperature: -20...+50 °C
- Supply: 24 VDC/VAC
- Protection class: IP65
- Photo ionization detector
- Detected vapors: acetone, ethanol, toluene, xylene, etc.
- Standard calibration: isobutylene
- Range: 0...40 / 0...200 ppm (isobutylene)
- Resolution: 1 / 1 ppb
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+65 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Metal-oxide gas sensor
- Detected vapors: acetone, ethanol, toluene, xylene, etc.
- Standard calibration: toluene
- Range: 0...100 % LEL (flammable range) / 0...1000 ppm (toxic range)
- Resolution: 0,1 % LEL / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+70 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 0,3 / 1 ppm O3
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...5 ppm O3
- Resolution: 0,01 ppm O3
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
Capacitive oil level sensor PWP-420.60, designed for oil, liquid fuel, food oil and other fluid level control in metal and nonmetal tanks. Special sensor versions are suited for work in aggressive fluid mediums (acids, alkalis).
Digital, programmable indicator N30H for DC voltage, current, with RS-485 interface.
- Device is designed for DC (bi-polar) voltage, current measurement
- LED indicator colors: red, green, yellow (for 3 input value ranges)
- Device is programmed with buttons or via RS-485 port
- 4 alarm inputs in 6 modes
- Measurement value conversion into analog signal 0/4...20 mA arba 0...10 V
- Minimal and maximal value storing for all measurements
The oxygen concentration meter MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 °C.
- Universal input (for standard signals and temperature sensors)
- Alarm output
- OLED display
- Configuration via miniUSB connector
- Supply: 24 VDC or 230 VDC / VAC
- IP65 protection class
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø9,8 mm
- Length: 1...35 m
- Tensile strength: ≤ 2,5 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø17 mm
- Length: 1...100 m
- Tensile strength: ≤ 8 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
- The purpose of the test chamber is to measure the airtightness of doors which are in the frame of chamber at set pressure
- Air is driven into the chamber with a ventilator which is controlled by an AC drive
- The intake flow rate is measured by CS Instruments VA420 flow rate meter (0-480 m3/4)
- The pressure in chamber is measured with DPT series differential pressure transmitter
- The temperature in chamber is measured in 11 points
- All data is logged and visualized in logger and computer (via IGSS software)
- Designed for the remote monitoring of measurements in industrial, domestic and environmental maintenance applications
- Typical applications include oil separator alarms, tank surface level measurements, monitoring pumping stations and real estate, and surface and groundwater measurements
- The device sends alarms and measurement results as text messages either directly to GSM phone or to the LabkoNet server
- Settings can be easily modified with a GSM phone
- Analog inputs: 4 units 4...20 mA (passive or active)
- Digital inputs: 4 units
- Relay outputs: 2 units
- Communication: SMS, GPRS
- Operating temperature: -20...+50 °C
- Supply: 230 VAC / 12 VDC battery
- Protection class: IP65
Single-phase commutator – controller RP7. The device can be used or circuit commutations. Can be used for resistive and inductive loads and single-phase motor speed control. Possible control with standard analog signal.
Other functions:
- Load current limiting
- Soft start
- Isolated inputs
- Load current control
- Fuse failure detection
- Overload indication
Converter PD8 is designed for data transfer from devices with RS-485 port to Ethernet network. The device comes in two versions. First version is used with network service Real Port. In this case, the Master role is taken by PC with installed software, creating a parallel port. Software (i.e. Lumel Energy) ensures data transfer between devices with RS-485 port and one PC.
Second version (parallel bridge with UDP protocol) enables the sextension of data transfer system using additional PD8 converters and local Ethernet network. Variant with two converters or one with many (max. 65) converts is available.
Linear encoder MLS210. With spiral connection.
Technical specifications
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC