  • 6-range lighting meter AHKF
  • Supply: 15...36 VDC (24 VAC for AHKF-U too)
  • Sensor: Photodiode in glass casing
  • Ranges: 0...500 Lux / 1 kLux / 2 kLux / 5 kLux / 20 kLux / 60 kLux
  • Output: 4...20 mA / 0...10 V
  • Ambient temperature: -35...70 °C
  • Accuracy: < ±10 %
  • Temperature accuracy: < ±5 %
  • Size: 72 x 64 x 37,8 mm
  • Protection type: III (EN 60730)
  • Protection class: IP 65 (EN 60529)

The barrel heater is designed to be used for heating the fluids and oil products stored in barrels. Heater is typically used with thermostat (30-110 °C), thermal cut-off (160 °C), cable (3 m) and plug for connection to an earth contact.

Cartridge electric heating elements are designed to emit large amount of heat in a small area. The heaters are made from heat-resistant steel or brass, with kanthal wire embedded in ceramics and supplemented with magnesium oxide (MgO).

  • Portable analyzer NP40 is designed for power network quality parameter analysis
  • Analyses voltage and current harmonics up to 51-st, THD
  • Real-time waveform display (4 voltage / 4 current)
  • Measurement of TRMS currents up to 3000 A (with standard sensor)
  • Half cycle RMS measurement (voltage and current)
  • Measurement in 1-phase and 3-phase systems (3- and 4-wire)
  • Voltage, current, harmonics, power, energy and other parameter measurement
  • Graphical representation of data in a waveform and vector diagram
  • Record of events: dips, swells, overvoltages
  • Built-in 8 GB memory card
  • Ethernet interface for remote monitoring
  • USB interface for data transfer
  • Color 5,6” TFT display, 320 x 240 px

LTC potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

The main difference from LTM transducers is that LTC has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines

LTM potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

Movement of up to 1000 mm. High resolution (0,01 mm). No additional parts such as gears are needed, because transducer construction enables the direct connection into mechanical system.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines

LTP potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

The main difference from LTM transducers is that LTP has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines
  • Long-life MOS or electrochemical gas sensor
  • Range 0....1000 ppm NH3
  • Resolution 1 ppm NH3
  • Outputs 4...20 mA / 0...10 V, RS-485

Power network transducer P41 is designed to convert 1-phase power network parameters into analog or digital signal. Measured parameters: voltage (U), current (I), frequency (f), active power (P), reactive power (Q), apparent power (S), power factor (PF), reactive power coefficient (tgφ), phase angle difference (φ), active energy (Ep), reactive energy (Eq).

  • universal inputs (1 A or 5 A, 100 V or 400 V)
  • programmable analog output ( -20 mA...+20 mA)
  • parameter transfer via RS-485 interface (Modbus RTU protocol)
  • chosen values memory (9000 records)
  • programmable current and voltage transformer coefficients
  • transducer settings are changed via „LPConfig“ software (USB)

Power network transducer P43 is designed to measure 3-phase (three or four-wire systems) power network parameters. Two parameter values are converted into analog output signal -20...+20 mA. Other parameter values are sent over RS-485 or USB ports. All parameter min and max values are measured. Data refresh interval is less than 1 s. Output signals are isolated from input and supply. Two programmable alarm outputs. Pulse (passive) output OC can be used for energy accounting. Mounted on 35 mm rail.

  • Measuring ranges:
    • current 1/5 A L1...L3: 0,02...6 A
    • voltage L-N/L-L: 2,9...276/ 10...480 V
    • frequency: 45,00...66 Hz
    • active power: -1,65 kW...1,4 W...1,65 kW
    • reactive power: -1,65 kvar...1,4 var...1,65 kvar
    • apparent power: 1,4 VA...1,65 kVA
    • power factor: -1...0...1
    • active energy: 0...99 999 999,9 kWh
    • sum energy: 0...99 999 999,9 kvarh
  • Consumed power: ≤ 6 VA
  • Transformation coefficients: Ku = 1...4000, Ki = 1...10000
  • Supply: 85...253 VDC or AC 40...400 Hz
  • Ambient temperature: -10...23...+55 °C
  • For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
  • Default calibration R-404a
  • Long-life MOS sensor
  • Range 0...1000 ppm
  • Resolution 1 ppm
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL (0...2,5 % vol.) C2H2
  • Resolution 0,1 % LEL (25 ppm) C2H2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor

Fluid level alarm Elcluwo 111S, designed for usage with conductometric probes for fluid level alarm and control.

 

Technical specifications

  • One or more level control
  • Switch output 2A, 250 VAC
  • Probe supply from isolated ~12 V source
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)

Fluid level alarm Elcluwo 112S, designed for usage with conductometric probes for fluid level alarm and control, depth pump protection.

 

Technical specifications

  • One or more level control
  • Switch outputs: switching + NO 2 A / 250 VAC
  • Probe supply from isolated ~12 V source
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)
  • One or more level control
  • Switch outputs: switching + 3 x NO 2 A / 250 VAC
  • Probes: galvanically isolated, max. 2mA, 5V~ 100 Hz
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)
  • Supply: 230 VAC / 24 VAC
  • One or two level control
  • Switch outputs – switching + 5 x NO, 2A / 250 VAC
  • Probes: galvanically isolated, max. 2uA, 5V~ 100 Hz
  • Adjustable sensitivity
  • Available modes – filling, draining, dry flow, overflow, two/three pump control and others
  • Valve or gate control
  • Adapted for work with various probes – SKS 401, 201, 101, SW-01 and others
  • Mounted on standard rail (35 mm)
  • Supply: 230 VAC / 24 VAC
  • Measurement speed: 0,6 s (up to 700 people per hour)
  • Integrated sensors: 5
  • IR thermal array, range: 0...100 °C (± 0,3 °C)
  • Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
  • Relative humidity sensor, range: 0...100 % (± 3 %)
  • Vibration sensor (for sabotage detection), range: 0,25...5 G
  • Distance sensor, resolution: 1 mm
  • Dew point calculation
  • Relay inputs: 2
  • Relay outputs: 2
  • LED indication, buzzer (85 dB)
  • Communication: Ethernet (10/100)
  • Connector (RJ45) for connection of other Kentix devices
  • Webserver
  • Software: remote connection with AlarmManager-PRO
  • E-mail, SNMP alarms, Rest API
  • SD card slot (to save pictures, card up to 128 GB)
  • PoE
  • Optional: RFID reader
  • Optional: wall bracket, cable
  • System consists of alarm device SET-1000 and fixed level vibration sensor SET/V
  • For usage separators, basins and tanks
  • Alarm device SET-1000 is a single-channel level switch
  • When used with SET/V, SET-1000 alarms when set high level in tank is exceeded
  • ATEX certified
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
Pressure peak damping element, designed to be used to protect measuring devices from sharp pressure changes in system. Made by Trafag (Switzerland).Environment: air, waterProcess connection: G1/4 male, G1/4 female (brass), G1/2 male, G1/4 male (stainless steel)Material: Stainless steel (model K5) or brass (model F5) Pressure peak damping element datasheet [EN, DE, FR] ..

Counter ALC77-C for linear and rotary encoders (up/down).

 

Technical specifications

  • 600 kHz input frequency
  • Encoder input (A and B signals)
  • 7-digit LED screen
  • Range -999...9999
  • 2 programmable set points (SPs)
  • 2 switch outputs + RS-232
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 72 x 72 mm

Counter ALC77-T for linear and rotary encoders (for tachometers).

 

Technical specifications

  • 5 kHz input frequency
  • Encoder input (A and B signals)
  • 7-digit LED screen
  • Range -999...9999
  • 2 programmable set points (SPs)
  • 2 switch outputs
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 72 x 72 mm

Counter ALC77-B for linear and rotary encoders (batch).

 

Technical specifications

  • 10 kHz input frequency
  • Encoder input (A and B signals)
  • 7-digit LED screen
  • Range -999...9999
  • 2 programmable set points (SPs)
  • 2 switch outputs
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 72 x 72 mm

Counter ALC94UNI for linear and rotary encoders (up/down), universal.

 

Technical specifications

  • 600 kHz input frequency
  • Encoder input
  • 6-digit LED screen
  • Range -99999...999999
  • 2 programmable set points (SPs)
  • 2 switch outputs OR RS-232
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 96 x 48 mm
  • Wide temperature range: -10...+1200 °C
  • 320 x 240 and 640 x 480 infrared resolution
  • 9 or 60 Hz models available
  • Sighting: IR-Fusion technology (thermal and visible sighting) for easy alignment and added detail on blended images
  • Remote motorized focus
  • Multiple field interchangeable lens options available
  • GigE Vision interface
  • LAN/Ethernet with PoE for communication with the thermal imager provides access to Ethernet, Web server and ThermoView Software
  • I/O alarming capabilities
  • ThermoView software for industrial automation applications
  • Ambient temperatures to 200 °C with high temperature enclosure
  • Air purge and accessories available
  • Rugged housing, IP67 rated
  • Indoor temperature controller of TR series (S+S Regeltechnik, Germany)
  • TR-040 (external setting): 0...40 °C
  • TR-040U (internal setting): 0...40 °C
  • TR-060 (external setting): 0...60 °C
  • TR-060U (internal setting): 0...60 °C
  • Output: Relay
  • Switching capacity: 24...250 VAC (16 A)
  • Ambient temperature: -35...65 °C
  • Protection class: IP65
  • TR series indoor thermostat with two temperature settings.TR-04040 (external setting)
  • TR-04040 (external setting): 0...40 °C/0...40 °C
  • TR-04040U (internal setting): 0...40 °C
  • TR-060 (external setting): 0...60 °C
  • TR-060U (internal setting): 0...60 °C
  • Output: Switch
  • Switching voltage / current: 24...250 V, 16 A AC
  • Ambient temperature: -35...65 °C 
  • Protection class: IP65
  • TOR-80 is designed to measure the dielectric strength of transformer oil and other dielectric fluids according to IEC 60156, ASTM D877 and ASTM D1816
  • Can work autonomously or transfer results to a PC, create a local database, generate reports, plot graphs and print results
  • There is software for the implementation of standard and custom measurement procedures
  • Max output voltage: up to 80 kV, sinusoidal
  • Output voltage measurement accuracy ± 2 %
    • Voltage increase rate: 0,1 to 5 kV/sec (adjustable)
    • Resolution of output voltage indication: 100 V
    • High voltage timeout after breakthrough: 4 ms typical (10 ms max)
  • Operating voltage:  85 – 264 V a.c. (48…63 Hz)
    • Power requirement: 250 VA max
  • Measuring cell volume for oil: 500 cm3
    • Temperature range of testing oil: 0…100 °C
  • Unit operating conditions:
    • Temperature: 0…50 °С
    • Storage temperature: -20… 60 °С
    • Relative humidity: Up to 90 % (without condensation)
  • Thermostat range 0...200 °C
  • Digital thermostat
  • Warm-up time - 24 hours (P = 1200W; 200 L; from 15 to 80 °C)
  • Coating material silicone/glass fiber
  • Glass fiber cap
  • Spring heating element with silicone insulation
  • Regulated clamp buckles
  • 3 meter supply cable
  • Protection class: IP40

Fluid level electrode probes SKC-101, designed to control conductive fluid level in high temperature and high pressure medium. Modifications differ by permissible operating temperature. Recommended to use with Elcluwo 112...114 level alarms.

  • Temperature range: -50...250 °C or -50...500 °C
  • Accuracy: ±0,03 °C
  • Resolution: 0,01 °C (switchable to 0,1 °C)
  • Display: LCD, 6 digits, backlight
  • MIN, MAX, hold functions
  • Sensor: Pt100
  • Protection class: IP65
  • Suitcase is ordered separately
  • Thermometer DT20 for temperature measurement in smokehouses, butcheries, etc.
  • Measuring range -50...20 °C, accuracy 0,1 °C
  • Sharp-tipped probe ST-03 (4x120 mm) made of stainless, acid-resistant steel (1H18N9T)
  • Cable length 3 m
  • Operating temperature 0...40 °C
  • Supply 230 V
  • Size 130x94x81 mm
  • Ergonomic ABS casing with indicator, IP65

Digital thermometer DT-34 is designed for fluid, gas and solid body temperature measurement in range of -50°C to 270°C. Casing is made out of mechanically resistant plastic (ABS) and contains special collars for dust, dirt and water protection.

The measurements are done with a Pt1000 sensor. Special sensor construction and small size ensure little thermal inertia and fast measurement. The results are shown in a 4-digit LCD display, of which the fourth digit shows the decimal part. Negative temperatures are shown with a minus sign. The device can be used in laboratories and manufacturing for technological measurements in various conditions.

Thermometer DT-34 can be shipped with a fitting temperature sensor made according to Your requirements.

Digital thermometer ST-90 for temperature measurement from -200 to 1200 °C.

ST-90 is designed for usage with various construction K-type thermocouple sensors. The sensor is connected via MiniTherm port on the top of ST-90. The device is supplied by 9V 6F22 battery (work time up to 500 h). Indication on LCD screen (3 1/2). Special collars protect the electronics from moisture, grease and dust.

Thermometer ST-90 can be shipped with a fitting temperature sensor made according to Your requirements.

  • Temperature range: -30...+70 °C
  • Humidity range: 0...100% RH
  • Resolution in range: 0.1 °C
  • Temperature accuracy: In range -20...+40 °C: ±0,5 °C; outside of range: ±1,0 °C
  • Humidity accuracy: ± 2 %RH
  • Supply: 3.6 V (Lithium battery)
  • Battery lifetime: up to 2 years
  • Protection class: IP65
  • Size: 45 x 100 x 19 mm

Digital thermometer DT-1 is designed to be used for temperature measurements in liquids, gasses and solids in range of -50...+200 °C. The casing is made out of mechanically resistant plastic (ABS) and has special collars, protecting the device from dust, dirt and water. The measurements are conducted using a Pt1000 sensor. Special sensor construction and small size guarantee little delay and fast measurement. The results are shown in 4-digit LCD (last digit represents the decimal part). The device can be used in laboratories and industry in any conditions.

Loading...