- High level detection
- Oil on water surface detection
- Designed for usage in separators, basins and tanks
- Easy to install, does not need calibration
- Reliable long-term se in harshest conditions
- Acoustic and visual alarms
- 2 switch outputs
- ATEX certified
- Wall-mounted
- Supply: 230 VAC, 50/60 Hz
- Temperature measurement range: 0...50 °C
- Humidity measurement range: 0...100 %
- Output: 2 x 0...10 V / 2...10 V / 4...20 mA
- Option: LCD display
- Option: relay output
- Option: Modbus RTU
- Supply: 24 VDC/VAC
- Operating temperature: 0...50 °C
- Protection class: IP20
- Temperature measurement range: 0...50 °C
- Humidity measurement range: 0...100 %
- Output: 2 x 0/2...5/10 VDC
- Option: LCD display
- Option: Modbus RTU
- Supply: 24 VDC/VAC
- Operating temperature: 0...50 °C
- Protection class: IP54
- Long-life metal-oxide gas sensor
- Range 0...100 % LEL H2
- Resolution 0,1 % LEL H2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor options
- Stable long-life electrochemical gas sensor
- Range 0...100 / 0...1000 ppm H2S
- Resolution 0,1 / 1 ppm H2S
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 10 / 20 ppm H2S
- Stable long-life electrochemical gas sensor
- Range 0...100 / 0...1000 ppm H2S
- Resolution 0,1 / 1 ppm H2S
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor option
- Electrochemical gas sensor
- Range: 0...100 / 0...2000 ppm H2S
- Resolution: 0,1 / 1 ppm H2S
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
The Kuhlmann Electro-Heat IBC Immersion Heater is an efficient solution for heating liquids in Intermediate Bulk Containers (IBCs), addressing viscosity challenges to enhance industrial productivity. Suitable for a variety of substances, it ensures consistent heating and easy liquid management. Its applications span multiple industries, including chemical processing, pharmaceuticals, food and beverage, and oil and gas. Constructed with durable stainless steel and featuring precise temperature control, this immersion heater combines performance with longevity.
Technical Specifications:
- Surface load: 2.2 W/cm²
- Power: 2000W
- Supply: 230V 1-phase
- Stainless steel tube element AISI 316L (1.4404)
- Length of element: 950mm
- Diameter of element: ø100mm
- Heated zone: 300mm
- Integrated PT100 sensor
- Minimum level of liquid during heating: 500mm (half full)
- Cable between heater and control unit: ~2800mm
- Digital controller: 0-90°C
An IBC silicone base heater efficiently heats up contents in an IBC container, making it easy to discharge viscous or semi-solid products with minimal waste. The 2700W heater can heat water from 15°C to 70°C in less than 40 hours. Kuhlmann’s durable silicone base heater fits various IBC containers and is easy to install and use. It can also be mounted with a digital temperature controller for precise temperature control.
Technical Specifications:
- Dimensions: 1035 - 851mm.
- Materials: 100% silicone.
- 1,5 meter power cord with no plugs.
- 0-150°C PT100 Sensor System temperature controller (additional product).
- Heats water from 15°C - 70°C in less than 40 hours in a fully loaded IBC Container.
idOil sensors are an integral part of the idOil oil separator alarm system and they are to be used with the idOil control units. All idOil sensors are digital and polarity free. Standard cable length is 5 m.
- idOil-LIQ high liquid level sensor|
Indicates when the liquid level in the oil separator rises excessively e.g. in an outlet blockage situation. - idOil-OIL oil sensor
Detects oil and indicates when the separator’s oil storage is full. - idOil-SLU sludge sensor
Monitors the sludge layer in the oil separator and indicates when the sludge layer has reached its maximum level.
“idOil®” is an alarm system intended for monitoring liquid levels particularly in oil and sand separators. The system consists of the idOil control unit and the idOil sensors installed in the separator. The sensor cables can be extended with a cable connector or connection box. One to three digital idOil sensors of the same or different type can be connected to the control unit. The sensors can be used to monitor the following:
- High liquid level (idOil-LIQ high liquid level sensor)
- Oil layer detection (idOil-OIL oil sensor is for class IIA explosive liquids and idOil-OIL-Soil sensor is for class IIB explosive liquids)
- Sludge layer detection (idOil-SLU sludge sensor)
- Measurement of parameters: voltage, current, active, reactive and apparent power, cosφ, tgφ, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
- Current and voltage harmonics analysis up to 51st (measurements available via RS-485)
- Programmable input:
- Current: 0…1 / 0…5A
- Voltage: 0…100V / 0…230V / 0…400V
- Output:
- Analog: 0/4...20 mA or 0...10 V
- Relays: 1 or 4
- Binary (OC)
- Digital output: RS-485 modbus (can be programmed through RS-485)
- Two-line LCD display
- Pulse output to measure energy consumption
- 4 alarm outputs with signaling on LED diodes, working in 7 different modes
- Conversion of any measured value into an analog signal 0/4...20 mA or 0...10V
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -25...23...55 °C
N19Z meter measures AC voltage and current. The meter is designed to work in 3-phase networks or 1-phase networks.
- Nominal input voltage: 300 or 600 V 1 phase / 100…500 V 3 phase
- Nominal input current: 1A or 5A
- True RMS measurement (up to 15th Harmonic)
- On site programmable PT/CT ratios
- User selectable 3ph3wire or 3ph4wire Network (for 3ph)
- Onsite selection of Auto scroll / Fixed Screen (for 3ph)
- 4 Digits 14mm ultra bright LED Display
- Protection: IP54 front / IP20 back
- Parameter Screen recall: In case of power failure, the instrument memorizes the last displayed screen
- Accuracy: ±0.5% of nominal value
The CM22 provides essential video security features in a compact form. It is a 3MP (2048x1536) camera with 10 meters of IR light range, and includes people and vehicle detection for motion search and trajectory analysis. The CM22 camera, combined with the SV23 vape detector and air quality sensor, and powered by the Verkada Command cloud computing platform, creates a powerful vape prevention and logging system.
- 30, 60 and 90 days of data retention (256…768 GB) on hardware and cloud back-up. If the connection to the Command cloud is lost, data is saved onboard and synced once the internet connection is restored
- Easy to install: no NVR, DVR, servers or port forwarding, just PoE connection
- Alerts: Camera status (offline), motion detection, people detection, vehicle detection, crowd detection, line-crossing detection, loitering detection
- Privacy: live face blur, privacy regions and audit log
- Field of view: Horizontal: 95°; Vertical: 69°; Diagonal: 130°
- Operating temperature / humidity: -10…50 °C / 0…90 %
- Connection and power input: RJ-45, PoE (IEEE 802.3af type 1)
- Certifications: FCC, ICES, RCM, VCCI, CE, UKCA, EN 50155 railway compliance, UL/cUL/IEC 62368-1, NOM
- Warranty: 5 years
The Internal IBC Heater is a unique approach to heating viscous foodstuffs and chemicals within IBC Containers. It is designed to protect sensitive products, such as syrups, honey, treacle, molasses, fats and other viscous products that are difficult to process. Most products can be batched within a relatively short time, increasing efficiency and reducing down time.
Technical specifications:
- Designed for insertion into 1000 litre cubic IBC but will also fit inside most IBC configurations.
- Adjustable temperature range from 0°C to 70°C using an easy to use controller on the top of the heater.
- 230/240 Volts - up to 2.4kW power output.
- Finned, food safe heating element that is inserted into the IBC, thereby heating the contents directly.
- Fast batching ability. Unique thermodynamic core that gives even temperature distribution along the heating extrusion,
- Preventing thermal damage to the liquid contents of the IBC.
- Non-stick industrial strength Xylon coating for easy washdown.
- Carefully designed low Watt density to protect sensitive products.
- Lightweight with stainless steel handles for easy insertion and extraction.
- Even temperature distribution along the length of the heating extrusion.
- Colored LED for power cycle and status indication.
- 16 Amp blue industrial power plug.
- Protective sleeve between the base of the control unit and the neck of the IBC to prevent ingress of contaminants.
- Robust Construction:
- IP67-rated body with potentiometer control mounted under protective see-through cover.
- The product is sealed to ensure that all the connections and components are waterproof.
- Robust IP67-rated aluminum case.
- Long life heating elements.
- Input: standard 4...20 mA signal or capacitive Labkotec 3W probe
- Current output: 0/4...20 mA
- Switch outputs: 2 units
- LCD display
- Programmable using buttons
- ATEX certified
- Wall-mounted, IP65
- Supply: 230 VAC, 50/60 Hz
- High level detection
- Oil on water surface detection
- Sludge under water detection
- Designed for usage in separators, basins and tanks
- Version with GSM module available – for alarms and service reminders
- Acoustic and visual alarms
- 2 switch outputs
- ATEX certified
- Wall-mounted
- Supply: 230 VAC, 50/60 Hz
- Output: switch
- Application: level sensing for solids
- Supply: 24 VDC / 220 VAC
- Sensitivity setting: 3 positions
- Rotation speed: 1 per minute
- Operating temperature: -20...+70 °C
- Operating pressure: up to 0,8 bar
- Material: body – plastic, other component – stainless steel
- Protection class: IP65
- Weight: 1 kg
- Incremental encoder output: A, B / A, B, Z / A, /A, B, /B / A, B, Z, /A, /B, /Z
- Resolution: 5 / 10 / 25 / 50 μm
- Magnetic measurement (contactless, non-friction system)
- Vibration-resistant
- Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
- Supply: 10...30 VDC / 5 VDC
- Operating temperature: -25...+85 °C
- Protection class: IP67
- Incremental encoder output: A, B / A, B, Z / A, /A, B, /B / A, B, Z, /A, /B, /Z
- Resolution: 5 / 10 / 25 / 50 μm
- Portable reference point
- Stroke values up to 2000 mm
- Vibration-resistant
- Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
- Supply: 10...30 VDC / 5 VDC
- Operating temperature: -25...+85 °C
- Protection class: IP65
SpotScan is a linear scanning add-on for RAYTEK, IRCON noncontact IR thermometers ENDURANCE, Marathon MM, Modline 5 and Modline 7
SpotScan is designed to broaden the capabilities of noncontact IR thermometers while scanning measured surface linearly thus measuring wider than one dot target area
The enLink IAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (0.1, 0.3, 0.5, 1.0, 2.5, 5.0 & 10), Barometric pressure, Sound*, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
- Distinguishes between vaping and smoke and counts the number of detections
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours or adaptive (triggered by vape or smoke)
- Power suplly: 12…24V V DC, 0.15 Amp (max)
- Configuration via USB cable / downlink
- Operating Temp. / Humidity: 0…40 °C / 0…95 % RH
- Long-lasting stainless steel screw electrodes
- Measurement range: 7...20 % (-40...+125 °C)
- Resolution: 0,1 %
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Electrode cable: FEP, -50...+200 °C, 5/10/15 m
- Timber temperature compensation
- Electrode length: 15 / 25 mm
- Supply: 11...30 VDC
- Protection class: IP68
The device is designed to measure ambient air pollution by detecting concentration and distribution of particles.
- Įėjimas: Pt100, Pt1000, 0…4000 Ω, TC (E, J, K, N, R, S), -75…310 mV, -10…10 V, -24…24 mA, potenciometras
- Relinė išėjimas: 1 x NO kontaktas, apkrovos galia 6 A / 250 V AC; 6 A / 30 V DC
- Skaitmeninis išėjimas: RS-485 / MODBUS RTU
- Išorinio įrenginio maitinimas: 24 V DC / 24 mA
- Matematinės funkcijos matavimo reikšmės konvertavimui
- Dviejų eilučių LCD ekranas (1 eilutė – 6 skaitmenys, 2 eilutė – 5 skaitmenys)
- Apsaugos klasė: priekio – IP65 / galo – IP10
- Darbinė temperatūra: -20...23...60 °C
- Maitinimas: 40…253 V AC / 20…300 V DC
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL (0...5 % vol) CH4
- Resolution 0,1 % LEL (50 ppm) CH4
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 20 / 50 % LEL CH4
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL CH4
- Resolution 0,1 % LEL CH4
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 20 / 50 % LEL CH4
- Visual and acoustic alarms
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL (0...5 % vol) CH4
- Resolution 0,1 % LEL (50 ppm) CH4
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor options
- Metal-oxide gas sensor
- Range: 0...100% LEL (0...5 %) CH4
- Resolution: 0,1 % LEL (50 ppm) CH4
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+70 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Range: -250...2550 Pa
- Maximal overpressure: 30 kPa
- Accuracy: ±1,4 %
- Pressure and air flow measurements from air diffusers and valves
- Data can be uploaded on your computer for visualization and further analysis
- Over 700 programmed valve types
- Mediums: air and non-aggressive gases
- Operating temperature: -10... +50 °C
- Connection: ø 5 mm pressure hoses
- Can be used with Pitot tube
- 5 year warranty
- Included: calibration certificate, 2 x 2 m PVC hoses
The JX-30 features the Delmhorst EDGE™ App with expanded wood species, customizable settings, and the ability to share data from any location.
- Moister measurement range: 6…60% Wood (Douglas Fir)
- Large, custom display with auto backlight – easy to read under all conditions
- Species: 74 plus 123 additional available through EDGE™ App
- Wood temperature correction (°F/°C)
- Pins/electrode correction (insulated or non-insulated)
- Alarm set point: alerts to user-selected moister level
- On-screen statistics: High, Low, Average, Standard Deviation, View all readings
- Internal calibration check
- “Low Batt” warning with audio
- Auto off timer. Set to 1 min, 4 min or 10 min
- Integral contact pins max 5/16” penetration (use 2498/A-100)
- Compatible with any Delmhorst external electrode
- Color-coded LED’s: adjustable through EDGE ™app
- Power: 2x AA batteries – Alkaline Energizer (included)
- QR code on meter for easy access to support materials
- Size: meter only: 220 mm x 72mm x 39mm; in carry case - 241mm x 165mm x 64mm
- Weight with case: 510 g
- Moisture reading range:
- 4,3…18 % moisture for paper (kraft paper calibration)
- 5…40 % for baled scrap paper (PX-30)
- 0…100 reference scale for obtaining relative moisture levels on other materials without calibration (PX-30)
- Large, custom display with auto backlight and modern light case for comfort use
- On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
- Bluetooth® connectivity to EDGE® app (PX-30). timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
- Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app PX-30)
- Internal calibration check
- “Low Batt” warning with audio
- Auto off timer. Set to 1m, 4m, or 10m
- Compatible with existing Delmhorst prods and electrodes
- Power: 2x AA Alkaline battery (Working hours: 125…150)
- Temperature Correction Range: -18…+124 °C
- QR code on meter for easy access to support materials and meter registration
- Size: meter only 21.97 x 7.24 x 4.06 cm
- Weight: meter only: 218 / 244 gm
- 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration
The Triton ULTRA is a multifunctional vape sensor capable of detecting e-cigarette vapor, marijuana smoke (THC), smoking, loitering, the number of people, gunshots, loud noise, and glass breakage.
- Measured parameters: Temperature, humidity, PM1.0, PM2.5, PM10, TVOC, CO2, NO2, CO, HCHO, sound level
- Customizable instant alarms based on the situation: Email notification, loud alarm, lights, *integration
- Tamper protection: device vandalism, masking and covering
- Real-time monitoring of student loitering via live video streaming
- No license subscription required for use
- The sensor independently performs all measurements and detections and sends alarms itself
- *Integration capability with many third-party systems: TCP, HTTP, MQTT, RTSP
- Event logging of alarms in the device
- Communication: LAN, WiFi
- Operating environment temperature / humidity: 0...44 °C / 0...90% RH (non-condensing)
- Power supply: PoE+ (IEEE 802.3at Class 3 compliance). Ability to connect up to 4 devices in series
Multifunction astronomical digital clocks RDT-TPA2 are applied for switching on and off the lightning or other electrical receivers in accordance to sunset and sunrise.
- 80 programs (astronomical and annual), holiday mode, random mode
- Automatic summer/winter digital clockover
- Automatic transfer of weekdays
- Sealable cover of the front panel, easy setting by 4 buttons
- Backlighted LCD display (can be turned off)
- 10-year power reserve (internal lithium battery which can protect real time clock and all the settings when the electric power supply is off)
- Number and type of contacts: 2 CO (each channel can be assigned an individual program)
- Rated load: 16 A / 250 V AC
- Direct mounting on 35 mm rail mount acc. to EN 60715
- Compliance with standards EN 60730-1, EN 60730-2-7, Directive RoHS
SIRO is an indoor air quality transmitter with a modern design. The transmitter is available with several optional air quality sensors. The modular device can be equipped with CO2 concentration and VOC (Volatile Organic Compounds) measurements or alternatively PM (Particulate Matter) measurement, and in addition, temperature and humidity measurements. SIRO-MOD series models use Modbus serial communication protocol.
- Measuring elements:
- CO2: Non-dispersive infrared (NDIR); 0...2000 ppm
- VOC: Complementary Metal Oxide Semiconductor (CMOS); range: * - see datasheet
- PM: Laser-based light scattering particle sensing
- Temperature: Integrated to CMOS
- Relative humidity: Thermoset polymer capacitive sensing element
- Field configurable outputs for selected measurements; Configuration possible through MODBUS
- Proportional output options including voltage (0–10 V, 0–5 V, 2–10 V) and optional current (4–20 mA); MODBUS
- Offset feature enabling field calibration for each measurement parameter (CO2, VOC, PM, RH, T)
- Optional LCD-display and buttons
- Operating temperature: 0…50 °C
- Protection standard: IP20
- Electrochemical gas sensor
- Range: 0...250 ppm NO
- Resolution: 1 ppm NO
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Stable long-life electrochemical gas sensor
- Range 0...20 / 0...200 ppm NO2
- Resolution 0,02 / 0,1 ppm NO2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 3 / 6 ppm NO2
- Stable long-life electrochemical gas sensor
- Range 0...20 / 0...200 ppm NO2
- Resolution 0,02 / 0,1 ppm NO2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Electrochemical gas sensor
- Range:
- -- 0...20 ppm NO2
- -- 0...200 ppm NO2
- Resolution:
- -- 0,1 ppm NO2 for 20 ppm range
- -- 1 ppm NO2 for 200 ppm range
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Noncontact infrared temperature meter 3i Plus (pyrometer), designed for metalworking industry where casting, hardening, heating take place. Also suitable for ceramics, semiconductor, chemical furnace temperature measurement
- It is a new generation, small size IR device for high temperature measurement
- Precise high-resolution optics guarantee high accuracy, resistant casing let the device survive falls from up to 1 meter height
- That said, measurements can be done in various environments and from various distances
- Noncontact stationary infrared temperature meter CM for temperature measurement
- Range: -20...500 °C
- Outputs: 0...5V, or TC K / J type (chosen while ordering)
- Software “DataTemp Multidrop” for remote monitoring and configuration
- Noncontact infrared thermal meter (pyrometer) ENDURANCE
- for temperature measurement up to 3200 ºC with the resolution of 0,1 ºC
- Outputs: Ethernet, profinet, 0/4...20mA (isolated), RS485, relay 48V and 300mA
- Web server
- Wider area can be measured when used with SpotScan
- Noncontact infrared thermal meter Marathon MM, wide range of accessories for various applications
- Range: -40...3000°C (in fixed ranges)
- Outputs: 0/4...20mA, RS485, mechanical switch
- Noncontact infrared thermal meter Thermalert TX, additional accessories for various applications
- Can be used in an explosive area
- Range: -18...2000 °C (in fixed ranges)
- Outputs: 4...20mA, HART į RS232, mechanical switch (depends on version)
- OilSET-1000 is designed for oil detection in separators, basins and tanks
- Easy to install, does not need calibration
- 2 switch outputs
- Ultrasonic sensor SET/S, 5 meter cable
- ATEX certified
- Wall-mounted, IP67
- Supply: 230 VAC, 50/60 Hz
ORP electrode sensors (glass, epoxy body and submersible)
The CH52-E four-camera multisensor features four independent sensors, providing expansive coverage from a single install point. Each sensor includes a 1 / 2.8” progressive CMOS image sensor, varifocal lens with 2.08x optical zoom, and 30 meters of IR range to provide clear and consistent image quality in any lighting condition. The CH52-E includes four onboard CV25S Ambarella processors to support advanced analytics like AI-powered search, Occupancy Trends, line crossing, loitering, and Person of Interest (POI) alerts. The CH52-E excels at covering hallway intersections and exterior corners of buildings, providing comprehensive visibility and eliminating blind spots while only requiring a single PoE++ cable.
- 30 - 365 days (1TB - 8TB) of onboard storage
- Redundant cloud backup and unlimited cloud-based archiving of footage
- Sensor Resolution: 4 x 5MP (2688 x 1944)
- Protection class / Impact rating: IP66 / IK10
- Operating temperature: -40…+50 °C
- Warranty: 10 Years
- Certifications: FCC, ICES, CE, UKCA, RCM, VCCI, KCC, NOM, CB, NTRA, ICASA, UL/cUL/IEC 62368-1, FY2019 NDAA compliant
- Stable long-life electrochemical gas sensor
- Range 0...20 % vol O2
- Resolution 0,01 % vol O2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 19,5 / 18 % vol O2
- Stable long-life electrochemical gas sensor
- Range 0...20 % vol O2
- Resolution 0,01 % vol O2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor options