  • Датчик температуры AUREGIS ТJ-1 с соединительным кабелем
  • Предназначен для измерения температуры в диапазоне -50°C до 400°C
  • Возможны исполнения по требованиям заказчика
  • Тип сенсора: PT100, PT1000, K, J, PTC, NTC, Ni120, Ni1000
  • T22CT can be used for network analysis, monitoring and measuring of non -sinusoidal and distorted networks AC current
  • Variations of measuring current range (A): 0...50 / 100 / 150 / 200 / 250 / 300 / 400 / 500 / 600 / 750
  • Output: 4…20 mA or 0…20 mA (Proportional change to input current)
  • Frequency range of Measuring current: 50…60 Hz
  • High electric isolation between primary conductor and output
  • Mounting onto 35 mm DIN rail by means of optional supply of snap on mounting
  • Auxiliary power supply: 24 V DC, ± 15%
  • Protection class: IP20
  • Operating temperature and Humidity: 0…+70 °C, 0...95% RH without condensation
  • The Si-83 tank pump is perfect for residential A/C (up to 20 kW) and heating units (up to 40 kW)
  • Max discharge head: 5,4 m
  • Max pressure: 5,7 m
  • Tank volume: 2 L
  • Automatic turn on specific level in tank
  • Overdraft level safety switch
  • Stainless steel motor shaft
  • Protection class: IP44
  • Max condensate temperature: 55 °C
  • Max condensate acidity: pH > 2,5 (Gas condensing boilers)
  • Quick installation with mobile app
  • Portable, small dimension temperature meter with a probe
  • The probe can be 1,5 m, 3 m or of specified length
  • Temperature measurement accuracy: ±1 °C
  • Temperature measurement range: -50...+150 °C
  • LCD screen
  • 2 year warranty
  • Supply: 1x6LF-22 (9 V)

The SV600 Fixed Acoustic Imager enables users to continuously detect, locate and visualize unheard and unseen air and gas leaks or changes in sound signatures before they become costly problems.

  • 64 MEMS digital microphones for image of leaks
  • Powerful processor for onboard real time processing: Sound classification, Frequency filtering, dB values and sound intensity mapping, Event triggering
  • Measuring distance: 3…15 m
  • Integrated visual light camera
  • The SV600 can be mounted on moving applications – including as a Boston Dynamics Spot
  • Can be mounted close to any equipment or asset, to any area of the production line, or where human access is restricted or dangerous
  • Option for IO support through fieldbus coupler
  • Integration: HTTP REST API, Modbus
  • Operating temperature: -20…+50 °C
  • Protection class: IP54
  • Communication and power supply: Ethernet RJ45, POE IEEE 802.3at
  • Air flow monitor with automatic reset function (alternatively available with error memory)
  • Switching point continuously adjustable, switching output 2 NO/ 2 NC
  • Robust sensor design, high sensor protection class IP67, sensitive and fast air flow detection
  • Examples of areas of application: Monitoring of heating registers, humidifiers, air curtain systems, dampers, fans, DDC
  • Operating on the Pitot tube principle
  • Insensitive to airflow direction
  • Accuracy: 2 %
  • Pairs well with HK Instruments DPT-FLOW transducers
  • Connection: 1/4” OD tubing
  • Operating temperature: 5...95 °C
  • Round or rectangular duct
  • Various duct size options (up to 1200 mm)
  • Air velocity measurement range: 0...2 / 0...10 / 0...20 m/s (selectable via jumper)
  • Temperature measurement range: 0...50 °C
  • Output: 0...10 V / 4...20 mA
  • Option: LCD screen
  • Option: relay output
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...+50°C
  • Protection class: IP54
  • Maximal pressure measurement range: 0...7000 Pa
  • Air flow and velocity measurement
  • LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 9 V battery
  • Operating temperature: 10...+50°C
  • Protection class: IP54
  • Maximal pressure measurement range: 0...1000/2000/5000/7000 Pa
  • Air flow and velocity measurement
  • Output: 0...10 V / 2...10 V or 4...20 mA
  • Option: autozero function and LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 10...35 VDC
  • Operating temperature: -40...+50°C (see datasheet)
  • Protection class: IP54
  • Universal airflow monitor with Safety Integrity Level 1 (SIL1) according to IEC 61508/IEC61511 (alternatively device with SIL2 certification available)
  • With switching output suitable for control cabinet installation
  • Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
  • Large measuring range from 0.1 ... 30 m/s, quick and easy commissioning
  • Example areas of application: Monitoring heating registers, air curtain systems, dampers, fans, DDC

Ambient humidity and temperature logger TERMIOPLUS-S with external sensor is designed for logging of ambient humidity and temperature in its internal memory.

  • Temperature range: -30...+70°C
    • Temperature accuracy: In range -30...+70 °C: ± 0,3 °C
    • Resolution: 0.1
  • Humidity range: 0...100 % RH
    • Humidity accuracy: ±2 %RH at 25 °C (30…70 %RH); ±3 %RH at 25 °C (10…90 %RH); ±4 %RH at 25 °C (0…100 %RH)
  • Memory: 32000 (16000 temperature and 16000 humidity)
  • USB interface for data download
  • Logging interval: 15 s...10000 min
  • Supply: 2xAA battery, 3.6 V
  • Battery lifetime: 1 one year with 30 min. interval recording at +10 °C
  • Size: 45 x 100 x 19 mm

Astronomical digital clocks RAT-TPA1B are applied for switching on and off the lightning or other electrical receivers in accordance to sunset and sunrise with an option to program a night break, which means a temporary switching off of the receivers for savings purposes

  • 52 programs, holiday mode
  • Automatic summer/winter digital clockover
  • Automatic transfer of weekdays
  • Sealable cover of the front panel, easy setting by 4 buttons
  • Backlighted LCD display (can be turned off)
  • 10-year power reserve (internal lithium battery which can protect real time clock and all the settings when the electric power supply is off)
  • Number and type of contacts: 1 CO
  • Rated load: 16 A / 250 V AC
  • Direct mounting on 35 mm rail mount acc. to EN 60715
  • Compliance with standards EN 60730-1, EN 60730-2-7, Directive RoHS

The ATEX LB Series Drum Heater is engineered for safe and efficient heating in explosion-proof environments. Designed for drums in Zones 1, 2, 21, and 22, it delivers reliable performance with self-limiting heating technology. Ideal for maintaining low-temperature processes and frost protection, it features robust, anti-static PVC fabric and a user-friendly ATEX-certified junction box. Perfect for industries handling volatile chemicals or requiring stringent safety standards.

Technical Specifications

  • Certification: CETS 23 ATEX 030 X; CETS 23 ATEX 031 U
  • Zones: Suitable for Zones 1, 2, 21, and 22
  • T-Class: T6, T5, T4, T3, T2, T1
  • IP Rating: IP65 for dust and water resistance
  • Operating Temperature: 65°C (energized) / 85°C (de-energized)
  • Ambient Temperature: -20°C to +55°C
  • Power Output: Self-limiting heating cable, adjustable to drum size
  • Materials: Anti-static, water-repellent PVC fabric (B2 Flame Retardant)
  • Connection Cable: 5m, 3G1.5mm² with ATEX-certified junction box
  • Available Sizes: For 200/220L drums
  • Applications: Frost protection, temperature maintenance, chemical processing

Solid drilled threaded thermowells, protective cases:

  • Protect and extend the lifetime of temperature sensors and thermometers in processing applications
  • Facilitate the replacement of sensors
  • Allow sensor maintenance without process interruption

The high temperature base drum heater heats metal drums from the bottom, with a diameter of 555mm, compatible with all size metal drums up to 200 liters. It has a built-in thermostat ranging from 50 to 300°C and can be combined with a traditional drum heater for faster heating. It can be used to heat a variety of industrial liquids.

Technical description:

  • Tubular heaters.
  • 50mm. Rockwool isolation.
  • 3-meter power cable.
  • Thermostat: 50° to 300ºC.
  • Weight: 15kg.
  • Can easily be used in conjunction with other drum heaters or insulation jackets for faster heating.
  • IP 54.

Ideal for heating up:

  • Water.
  • Oils and also diesel fuel.
  • Resin.
  • Vaseline.
  • Wax, e.g. lanolin (wool wax or wool grease).
  • Fats.
  • Glue.
  • Adhesives.
  • SET-1000 + SET/OSK2 is designed for oil detection on water surface
  • Can be used in tanks where water level is alternating
  • Control device SET-1000 is a one-channel level switch
  • SET/OSK2 sensor detects more than 15 mm width hydrocarbon layer on water surface
  • Polypropylene floats
  • ATEX certified
  • Wall-mounted, IP67
  • Supply: 230 VAC, 50/60 Hz

Carbon dioxide (CO2) and temperature transmitter with a display CDT2000 Duct. The device is designed for measurement of air parameters in ventilation channels.

  • CO2 range 400...2000 ppm
  • Temperature range 0...50 °C

Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.

  • Carbon dioxide (CO2) range: 400...2000 ppm
  • Humidity range: 0...100 % 
  • Temperature range: 0...50 °C
  • Stable long-life optical NDIR gas sensor
    Range 0...10 000/50 000 ppm CO2
    Resolution 1/100 ppm for 10K/50K range CO2​
    Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
    Remote probe option

  • Stable long-life optical NDIR gas sensor
  • Range 400...5 000/10 000/50 000 ppm CO2
  • Resolution 10 ppm CO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • NDIR gas sensor
  • Range: 0...10 000 ppm CO2
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: 0...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC as options

Carbon dioxide transmitter CMT is designed for CO concentration measurement. The transmitter is used to control interior ventilation systems.

  • CO range 0...300 ppm
  • Stable long-life electrochemical gas sensor
  • Range 0....1000 ppm CO
  • Resolution 1 ppm CO
  • Default alarms at 25 ppm / 35 ppm CO
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Stable long-life electrochemical gas sensor
  • Range: standard 0....200 ppm CO, maximal 0...1000 ppm CO
  • Resolution 1 ppm CO
  • Default alarms at 25 ppm / 125 ppm CO
  • Outputs 2 x relays with switch-over contacts
  • Visual and acoustic alarms
  • Long-life electrochemical cell
  • Range 0....1000 ppm CO
  • Resolution 1 ppm CO
  • Outputs 4...20 mA / 0...10 V, RS-485
  • Stable long-life electrochemical gas sensor
  • Range 0....200 ppm CO
  • Resolution 1 ppm CO
  • Outputs 2 x relays with switch-over contacts
  • UART digital interface
  • Visual and acoustic alarms
  • Magnetic key switching
  • Electrochemical gas sensor
  • Range:
  • -- 0…300 ppm CO
  • -- 0...1000 ppm CO
  • Resolution: 1 ppm CO
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • The versatile Si 2052 is suitable for replacement of some market standards drain pumps used in cassette type air-conditioning units up to 20 kW
  • Max discharge head: 0,9 m (flow rate = 24 l/h)
  • The single level detection unit can be used as a safety contact (NC 50 VA resistive – 250 V) to cut off automatically the air conditioning system compressor or solenoid valve
  • The centrifugal technology inside this pump is specifically designed for removing condensates continuously, in any kind of environment, with a very low sound level (≤ 30 dBA)
  • Protection class: IPX4
  • Operating conditions: 100 % - continuous duty
  • Lokaset 20 is designed for high wastewater level detection in septic tanks
  • Easy to install, does not need calibration
  • Switch output
  • Visual and acoustic alarms
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • Stable long-life electrochemical cell
  • Range 0...20 ppm Cl2
  • Resolution 0,02 ppm Cl2
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 0,5 ppm/1 ppm Cl2
  • Remote probe option
  • Stable long-life electrochemical cell
  • Range 0...20 ppm Cl2
  • Resolution 0,02 ppm Cl2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • Electrochemical gas sensor
  • Range: 0...10 ppm Cl2
  • Resolution: 0,1 ppm Cl2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC (default), 24 VAC or 90...265 VAC
  • For methane, butane, propane and hydrogen
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarms at 20 / 50 % LEL
  • For methane, LPG, hydrogen and acetylene
  • Can be calibrated for metane, propane and butane
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 x relays with switch-over contacts
  • Default alarms at 10 / 25 % LEL
  • For methane, butane, propane and hydrogen
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • For methane, LPG, hydrogen and acetylene
  • Can be calibrated for methane, butane, propane, acetylene and hydrogen
  • Stable long-life metal-oxide gas sensor
  • Range: 0...100 % LEL
  • Resolution: 0,1 % LEL
  • Outputs 2 x relays with switch-over contacts
  • Default alarms set-points 10 / 25 % LEL
  • UART digital interface
  • Alarms: blinking LED, 85 dB buzzer
  • Metal-oxide gas sensor
  • Detected gases: hydrogen, methane, acetylene, propane, butane
  • Standard calibration: methane
  • Range: 0...100 % LEL
  • Resolution: 0,1 % LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Compact air flow meter with switching output (1 NO)
  • Robust sensor design, protection class IP67 and compact dimensions
  • Switching point continuously adjustable between 0.1...15 m/s (extended measuring range available with RLSW5)
  • Exemplary areas of application: monitoring of fans, heating registers, extraction, soldering and air curtain systems
  • Compact air flow meter with switching output (1 NO / 1 NC) with TÜV type examination (according to DIN EN 61010-1: 2011-07)
  • Robust sensor design, protection class IP67 and compact dimensions, sensitive and fast air flow detection
  • Media temperature up to 60 °C
  • Switching point continuously adjustable between 0.1...30 m/s
  • Exemplary areas of application: Visualization and control of air flows in building automation, filter and fan monitoring as well as in industrial applications such as catalytic converters
  • Compact air flow meter with analogue output (0…10 V & 4…20 mA)
  • Robust sensor design, protection class IP67 and compact dimensions
  • Media temperature up to 70 °C
  • Switching point continuously adjustable between 0.1...30 m/s
  • Exemplary areas of application: Visualization and control of air flows in building automation, filter and fan monitoring as well as in industrial applications such as catalytic converters
  • Flow monitors for water and air flows
  • Robust stainless steel sensor housing for industrial environments
  • Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
  • Switching point sensitive and continuously adjustable both for liquids (0.03 ... 3 m/s) and for gases (0.5 ... 20 m/s)
  • With switching output (1 NO/ 1 NC)
  • Exemplary areas of application: Monitoring of air and water flows, cooling circuits up to 30% glycol content, pump monitoring
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
  • Relay output: 2 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Temperature input: none / Pt100 / Pt1000 / thermocouple
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
  • Relay output: 3 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA (optional: double output)
  • Relay output: 4 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
Microprocessor controller INDU-30 with RS-485 interface for temperature and humidity control in food and other industries. The device is designed for temperature and humidity control in food and other industries (drying, climate chambers, etc.). Humidity measurement is done via psychorometer method. Two programmable inputs are used for temperature sensor connection and one for standard signal 0/4...20 mA. Version for work with thermocouples is also available. The device can log measured values in set time intervals. Data is transferred via RS-485 interface. Control starts in set t..
Microprocessor controller INDU-50 with RS-485 interface for temperature control in thermal processing devices in food industry. The device is intended to be us in boiling pots, vaporizers, grills, climate chambers and so on. Measured values can be logged into the internal memory. Data is transferred via RS-485 interface. Real time clock. Control starts in set time or after set delay. Technical specifications Input: 2 analogue inputs PT-100 (PT-500, PT1000) channel 1: temperature – ‘dry’ thermometer channel 3: temperature – ‘we..

The DPI series electronic pressure measuring devices are engineered for building automation in HVAC/R industry. The most technologically advanced and versatile electronic differential pressure switches on the market, combining up to two relay outputs and 0–10 V output options.

  • Range: from 0....60 to 0...5 kPa
  • Accuracy: ±2% (FS 20°C)
  • Allowed overpressure: 20 kPa
  • Operating temperature: -5...+60°C

Differential manometer DPG/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.

  • Range: 0…1500 Pa
  • Switch activation range: 20…1500 Pa
  • Operating temperature: -5… +60°C
Loading...