  • Volumetric flow and air velocity meter with linear analogue output in control quality (0...10 V & 4...20 mA) and switch
  • Suitable for media temperatures up to 350°C
  • Measured value display by means of LCD and LED
  • Freely scalable measuring range m/s, m³/h, l/min
  • Sensitive and fast airflow detection up to 30 m/s
  • Exemplary areas of application: Measurement and control of air flows, building services, PLC, filter monitoring, extraction and extrusion systems, exhaust gases and test benches
  • Pressure measurement range: 0...1000 Pa, 0...5000 Pa
  • Volume flow, differential pressure measurement, filter monitoring and liquid level detection
  • Volume flow: 10...100% [m3/s][m3/min][m3/h]l/s][l/min][l/h]
  • Filter monitoring: 10...100%
  • Liquid level detection: 0 – 8...14 cm or 0 – 39...72 cm (depends on pressure range)
  • Output: 0 – 10 V, 1 x changeover contact
  • Measurement element: piezoresistive sensor
  • Application: in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spay booths, in large scale catering facilities, for filter monitoring and level measurement or for triggering frequency converters.
  • Medium: clean air, non-aggressive, non-combustible gasses

 

The TSF400-0 is a compact water-leak detector designed for early detection of water presence on floors, trays, or inside equipment enclosures. It operates from a wide 4.5–26 VDC supply and provides an N-channel open-drain output for direct connection to PLCs, controllers, alarm modules, or building-automation systems.

Applications:

  • Leak detection in server rooms, UPS rooms and telecom shelters
  • HVAC drip trays, cooling/condensation lines
  • Under-floor and raised-floor monitoring
  • Domestic and commercial flood-alert systems

Specifications:

  • Operating temperature range: 0...50 °C
  • Ingress protection: IP65
  • Cable length: 3 m

The LoRa-Log-Vape system, using LoRaWAN communication technology, is designed for detecting "vaping" and cigarette smoke. Sensors capture environmental parameters and, upon detecting an event, send a notification to the LoRaWAN receiver (gateway). The data is collected and processed in the receiver and can be viewed on a web page.

The LoRa-Log-Vape registration system consists of a wireless LoRaWAN sensor receiver and wireless Synetica “vape” sensors ENL-IAQ-Vape.

  • Water leakage detector G2-LD detects leakage with active 1 meter cable
  • Up to 2 leakage cables mountable
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: configurable C, T, or S (configurable)
    • AES-128 encryption mode 5, profile A
  • Transmission interval: configurable 60 s…1 hour
  • Operating temperature: -30…+85 °C (recommended +5…+50 °C) (None condensing)
  • Warnings about low battery, case opened or removed from wall (opt.), leakage detected (red LED)
  • Power supply: ER14505 3.6 V Li-SOCI2 battery
    • Battery lifetime up to 14 years, depends on configuration and operating temperature

Designed for precisely measuring electricity usage and frequency of use. Pulse counter belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • Compliance with MID certificate
  • Maximum current: 40 A
  • Nominal voltage: 230 V, 50 Hz
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply (pulse counter): 1 x AA battery
  • Battery lifetime (20 °C): up to 10 years
  • Protection class sensor / meter: IP67 / IP40

High-precision sensors in a pre-assembled enclosure box, designed to measure pH in irrigation water for horticulture. This device, belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • pH level measurement range: 0…14
  • pH sensor operating temperature: 0…+60 °C
  • Wireless data transmission and grid-powered
  • Kit contains: 4…20 mA transmitter with 24 VDC PSU, Glass pH probe, pH 4…20 mA module
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min                    
  • For more accurate measuring use sensor in combination with Horticulture Drainage sensor
  • For proper use see user manual

Sensor SKU: 5905309600546 (IP67)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud** platform or any other third party systems.

  • Moisture measurement range: 0…200 centibar (kPa)
  • Temperature measurement range: -55…+125 °C, accuracy: up to 0,5 °C in the range -10…+85 °C and up to 2 °C in the range -55…125 °C
  • The temperature sensor is used to adjust the results of soil moisture readings
  • Soil moisture and temperature sensors cable length: 3 m
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -35…+70 °C / 0…99 % RH non-condensing
  • Case IP67 protection

Designed for precisely measuring electricity usage and frequency of use. Pulse counter belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • Compliance with MID certificate
  • Maximum current: 80 A
  • Nominal voltage: 3 x 230 / 400 V, 50 / 60 Hz
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply (pulse counter): 1 x AA battery
  • Battery lifetime (20 °C): up to 10 years
  • Protection class sensor / meter: IP67 / IP40

Sensor SKU: 5905309601352 (IP30)

Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.

  • Sensor detects the presence of conductive liquid (e.g. water) at any point along the entire length of the cable
  • Probe maximum working temperature: 70 °C
  • Probe length: 3 m (different probe length on request)
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -35…+70 °C / 0…99 %
  • Case IP30 protection

Sensor SKU: 5906660327684 (IP30)

Sensor SKU: 5905309600348 (IP67)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.

  • Sensor detects the presence of conductive liquid (e.g. water) at any point along the entire length of the cable
  • Probe maximum working temperature: 70 °C
  • Probe length: 3 m (different probe length on request)
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection (IP67 on request)

Sensor SKU: 5905309601345 (IP30)

Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.

  • Detection of the presence of a conductive fluid (e.g. water) on the level at which the probe is mounted
  • Probe length: 3 m
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -35…+70 °C / 0…99 %
  • Case IP30 protection

Sensor SKU: 5906660327677 (IP30)

Sensor SKU: 5905309600645 (IP67)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.

  • Detection of the presence of a conductive fluid (e.g. water) on the level at which the probe is mounted
  • Probe length: 3 m
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection (IP67 on request)
  • Measures and records power network parameters in single phase or three phase 3 and 4-wire symmetrical and asymmetrical systems
  • 54 electrical network quality parameters
  • Analysis of voltage and current harmonics (up to the 51-st)
  • Color touchscreen: LCD TFT 3.5“, 320 x 240
  • 2 configurable alarm outputs
  • Analog output 0/4...20 mA and 2 x Pt100 inputs (optional)
  • Digital output: RS-485 (MODBUS)
  • Ethernet / Profinet 2.2
  • Supply: 85...253 VAC / 90...300 VDC or 20...40 VAC / 20...60 VDC
  • Battery backup RTC
  • Dimensions: 96 x 96 x 77 mm
  • The innovative multiple sensing head interface, which can support up to 8 individually addressable heads per communication box
  • reduces sensor cost, simplifies sensor installation and applications troubleshooting, and provides the lowest cost per measurement point
  • Temperature measurement range: -40...+2250 °C (different versions)
  • Advanced signal processing
  • Wide choice of focus distances
  • Durable stainless steel IP64 enclosures designed to withstand ambient temperatures from -20 to 85 °C
  • Integrated laser sighting
  • Galvanic isolated outputs
  • Plastic lens option for food application
  • Analog input for ambient compensation and adjusting emissivity setting
  • USB for easy setup
  • Simple, two-wire or digital installation
  • Backward compatibility to old Raytek and Ircon in class sensors and accessories
  • Real-time thermal line-scanner system for continuous or discrete process measurements
  • Up to 1024 measurement points per line
  • Fast scan rates up to 150 lines per second (real-time 150 Hz thermal imaging)
  • Optical resolution up to 200:1
  • Built-in line laser for rapid alignment
  • On-board Ethernet TCP/IP communication
  • PC independent alarm output
  • PC independent 4...20 mA interfaces (3 outputs)
  • Wide choice of models and spectral responses
  • Rugged, waterproof IP65 enclosure
  • Water cooling for ambient temperature up to 180 °C

Interior protection from flooding sensor CZP-103R, designed for protection of various rooms (workshops, servers, communication modules, etc.) against flooding. The sensor activates when there is water between its electrodes. Can be used in drainages and rainfall wells for protection against basement flooding. LED indication.

 

  • Flood protection
  • Alarm and control
  • Supply 12...24 VDC
  • Isolated ~5 V electrode supply
  • Low energy consumption
  • Size 19 mm x 66 mm
  • Temperature sensor MWTF is designed to measure the average temperature (S+S Regeltechnik, Germany)
  • Range: -30...80 °C
  • Measuring capillary: Ø5 mm, L=0.4 m / 3 m / 6 m / up to 20 m
  • Capillary material: Copper, plastic-coated
  • Protection class: IP65

Fluid level electrode probes SKC-201, designed to control conductive fluid level in open and pressure tanks. Electrodes – rod or flexible (rope with plastic coating). Probe head is made of acid-resistant steel. Maximal electrode count – 3. Insulation is made out of high quality plastic, enabling the probe to be used in food industry. Standard version probes are coated with plastic (FEP, PU, PVDF), lowering the residue collection (slime, carbonate, foam, etc.). Two modifications are available – with connection cable (P) and connector (G).

  • Stable long-life electrochemical gas sensor
  • Range 0...5 ppm O3
  • Resolution 0,03 % ppm O3
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor
  • Stable long-life metal-oxide gas sensor
  • Range 0....1000 ppm NH3
  • Resolution 1 ppm NH3
  • Default alarms at 25 ppm / 35 ppm NH3
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Electrochemical gas sensor
  • Range: 0...100, 0...300, 0...1000, (0...10000 on request) ppm NH3
  • Resolution: 1 / 2 / 5 ppm NH3
  • Sensor lifetime: > 2 years
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -10...+50 °C
  • Supply: 11..30 VDC / 24 VAC or 90...265 VAC
  • Metal-oxide gas sensor
  • Range: 0...1000 ppm NH3
  • Resolution: 1 ppm NH3
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+50 °C / 15...90 %RH
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • NDIR gas sensor
  • Range: 0...50 000 ppm CO2 (up to 100 % CO2 on request)
  • Resolution: 0.01 % vol.
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -25…+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Electrochemical (CO) and optical NDIR (CO2) gas sensors
  • Range: 0...100 ppm CO, 0...10000 ppm CO2
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Operating temperature: -20...+50 °C
  • Supply: 24 VDC/VAC
  • Protection class: IP65
  • Electrochemical gas sensors
  • Range: 0...100 ppm CO, 0...20 ppm NO2
  • Resolution: 1 ppm CO, 0,1 NO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Operating temperature: -20...+50 °C
  • Supply: 24 VDC/VAC
  • Protection class: IP65
  • Photo ionization detector
  • Detected vapors: acetone, ethanol, toluene, xylene, etc.
  • Standard calibration: isobutylene
  • Range: 0...40 / 0...200 ppm (isobutylene)
  • Resolution: 1 / 1 ppb
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+65 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Metal-oxide gas sensor
  • Detected vapors: acetone, ethanol, toluene, xylene, etc.
  • Standard calibration: toluene
  • Range: 0...100 % LEL (flammable range) / 0...1000 ppm (toxic range)
  • Resolution: 0,1 % LEL / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Stable long-life electrochemical gas sensor
  • Range 0...5 ppm O3
  • Resolution 0,03 % ppm O3
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 0,3 / 1 ppm O3
  • Attached or remote sensor
  • Electrochemical gas sensor
  • Range: 0...5 ppm O3
  • Resolution: 0,01 ppm O3
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

Differential manometer MM for air and non-aggressive gasses, designed for pressure measurement in narrow ranges.

  • Range: -100…1500 Pa
  • Operating temperature: -40… +60°C

Capacitive oil level sensor PWP-420.60, designed for oil, liquid fuel, food oil and other fluid level control in metal and nonmetal tanks. Special sensor versions are suited for work in aggressive fluid mediums (acids, alkalis).

  • Power network parameter meter N14 is designed for measuring of three-phase network parameters and accounting of internal energy consumption. Can be used in 3- or 4-wire systems
  • Can be used in energetic monitoring systems (RS-485 port)
  • Active and reactive power measurement, active and reactive power counters, average power measurement
  • Phase, current and voltage effective value measurement
  • Network frequency measurement
  • Average active power (over set time) measurement
  • Changeable current and voltage transformer transfer coefficient values
  • Operating temperature: -30...+50 °C
  • Programmable switch output and RS-485 (MODBUS) port
  • Pulse output for remote energy accounting
  • Accuracy class: current, voltage 0,5/1,0; frequency 1,0; power 2,0; energy 1,0/2,0; tg φ 1,5
  • Designed for direct or indirect measurement of 1-phase network parameters
  • Measured values: U, I, f, P, Q, S, PF, tg fi, fi, Ep, Eq
  • Direct measurements up to 63 A
  • Universal input: 1/5 A 100/400 VAC or 32/63 A, 100/400 VAC
  • Outputs: RS-485 (MODBUS interface), 1x relay + 1x analog or 2x relay
  • OLED display
  • Programmable current and voltage transformer ratios
  • Programmable via buttons or free eCon software (through USB)
  • Size: 53 x 110 x 60 mm
  • Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
  • THD factor
  • Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
  • Digital output: RS-485 MODBUS (option)
  • Protection class for front side: IP65
  • Supply: 85...253 VDC/VAC
  • Backlit LCD display
  • Dimensions: 96 x 96 x 77 mm
  • Power network meter ND20 is designed to measure 3-phase network parameters and to account internal energy consumption
  • Usable in 3- and 4-wire systems
  • Can be used in energetic monitoring systems (RS-485 port)
  • Front panel protection class IP65
  • Harmonic, THD, watthour measurement
  • 3,5” LCD indicator
  • Analog output of 0/4...20 mA (additionally ordered)
  • Measurement of power network parameters in 1-phase and 3-phase (3 or 4-wire) systems
  • Current inputs 0,1 A and 0,25 A (for dedicated transformers)
  • Quick and convenient ways to connect current transformers via RJ12 connector or screw terminals
  • Designed for usage with following transformers: LJ12, LJ25, LJ35, LJ45, LJ306, LJ307, LJ308
  • RS-485 (MODBUS RTU) interface
  • THD factor measurement
  • Backlighted LCD 3,5”
  • Protection grade from the frontal side: IP65
  • Power network parameter measurement in 1- and 3-phase network
  • THD factor calculation
  • High accuracy class
  • Backlit LCD 3,5” display
  • RS-485 Modbus slave interface
  • Frontal protection class: IP65
  • Measures 54 power network parameters (up to 63-rd harmonic, in 1- and 3-phase network)
  • Color LCD TFT 3,5” display
  • Display pages are fully configurable by user (10 pages. 8 parameters in each)
  • 2 configurable alarm outputs
  • Digital RS-485 Modbus output
  • Optional: 0/4...20 mA output and 2xPt100 inputs
  • Option: logging of 32 parameters into internal 8 GB memory
  • Modbus TCP/IP, HTTP, FTP server, WWW server, DHCP client
  • Carbon dioxide (CO2) range: 0… 2000 ppm or 0…4000 ppm (selectable)
  • Stable long-life optical NDIR sensor
  • Response time: < 2 min
  • Output: 0...10 V arba 4...20 mA
  • Ambient temperature: 0...+ 50 ºC
  • Supply: 24 VAC/ VDC
  • Protection class: IP 30
  • Dimensions: 98 x 98 x 33 mm
  • Application: offices, hotels, convention centers, apartments, shops, etc.
  • Meter N27D is designed to measure parameters of the single-phase power network
  • Direct measurements up to 63 A
  • The device measures voltage, current, frequency and active power
  • Measurements are represented in 4-digit display
  • Button enables the scrolling through available measurements
  • Mounted on standard 35 mm rail (LST-EN 62208)

2, 3 or 4 axes ADR10 series indicators for digital systems, linear displacement measurements, movement measurements, positioning detection. These indicators are used with optical and magnetic linear encoder scales ALS or MLS. Error compensation.

 

Application:

  • Lathes
  • Milling machines
  • Plate metal processing mills
  • Grinding machines
  • Erosion machines
  • Mechanical processing centers
  • Designed for the remote monitoring of measurements in industrial, domestic and environmental maintenance applications
  • Typical applications include oil separator alarms, tank surface level measurements, monitoring pumping stations and real estate, and surface and groundwater measurements
  • The device sends alarms and measurement results as text messages either directly to GSM phone or to the LabkoNet server
  • Settings can be easily modified with a GSM phone
  • Analog inputs: 4 units 4...20 mA (passive or active)
  • Digital inputs: 4 units
  • Relay outputs: 2 units
  • Communication: SMS, GPRS
  • Operating temperature: -20...+50 °C
  • Supply: 230 VAC / 12 VDC battery
  • Protection class: IP65

Linear encoder MLS210. With spiral connection.

 

Technical specifications

  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS110. With cable connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS110. With spiral connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS120.

Technical specifications

  • Casing integrated into slider
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS130. Very small size.

 

Technical specifications

  • Very small measuring head (in metal enclosure)
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS210. With spiral connection and slider joints.

 

Technical specifications

  • Protection class IP67
  • Twin sliders
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC