- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- Pressure measurement range: 600...1100 hPa
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- GSM modem (GPRS)
- SMS and JSON messages can be sent via GPRS data connection
- Messages can be sent on alarms and periodically
- Data can be transferred to PC via USB-C interface
- Calibration certificate of manufacturer included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
- Universal air and environment quality sensor E2-CO2-series measures CO2 (carbon dioxide) level, temperature, humidity, pressure, sound level, ambient light (LUX). Transmits instant values, average hourly values, and average 24-hour values
- Communication: wM-BUS EN13757-3/4:2013, complies OMS 4.0.2
- Modes: C1-A/B, T1 or S1 (selectable on order)
- Measurement ranges
- Temperature: -40…85 °C
- Humidity: 0…100 % RH (non-condensing)
- CO2: 0…5000 ppm (0…55 °C)
- LUX: 0,01…83000 LUX at same frequency as the human eye
- Absolute pressure: 20…100 kPa
- Sound level: 20…90 dBa at 850 Hz
- Measurement accuracy
- Temperature: ± 0,2 at +5…+60 °C; ± 0,5 at -20…+85 °C
- Humidity: ± 2 % RH at 20…80 % RH; ± 3 % RH at 10…90 % RH; ± 3,5 % RH at 0…100 % RH
- CO2: ± (50 ppm + 3%)
- LUX: 4 %
- Pressure: 0,4 kPa
- CO2 sensor calibrates every 20 days
- Warnings about low battery, CO2 sensor malfunction, calibration not performed yet
- Transmission interval: every 90 seconds
- Measured values sample interval: every 6 minutes
- LED and sound indication about CO2 exceeded limit
- Device has 2 antennas for maximum range in both vertical and horizontal directions
- Power supply: 2 x ER18505 3.6 V Li-SOCI2 battery pack (8200 mAh)
- Up to 14 years battery lifetime, standard configuration and operating temperature
TSV202-60 ideal for monitoring battery banks, solar panels, industrial control circuits, and other high-voltage applications.
- Dual channel input: 0…60 V
- Communication interface: 1-Wire protocol
- Accuracy: ±1%
- Resolution: 0.001V
- Galvanic isolation between the voltage circuit and 1-Wire bus
- Operating environment: -20…+60 °C / 10…90 %RH
- Warranty: 3 years
- 1-Wire protocol ambient light sensor
- Light measurement range: 0...83000 lux
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
- Dual channel input: 0…24 mA or 0…10 V
- Communication interface: 1-Wire protocol
- Accuracy: ±1 %
- Resolution: 0.001mA / 0.001 V
- Galvanic isolation between the current circuit and 1-Wire bus
- Detection of special states such as sensor errors or calibration values
- Operating environment: -20…+60 °C / 10…90 %RH
- Warranty: 3 years
- 1-Wire protocol ambient pressure sensor TSP200
- Pressure measurement range: 300...1100 hPa
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
TSM400-1-CP is a multi-parameters sensor that supports the 1-Wire protocol. The sensor measures the concentration of carbon dioxide and atmospheric pressure.
- CO2 measurements range: 400…5000 ppm
- Accuracy: ± (40 ppm + 5 %)
- Resolution: 1 ppm
- Calibration: manual
- Pressure measurements range: 10…1200 hPa
- Accuracy (min): ±1.5 (25°C, 750 hPa)
- Accuracy (max): ±2.5 (-20 °C to + 85 °C, 300…1100 hPa)
- Resolution: 1 hPa
- Operating temperature range: -20…+60°C
- Operating relative humidity range: 5…95% (non-condensing)
- Ingress protection: IP20
- Operating voltage range: 4,5…26 VDC
- 1-Wire protocol current transmitter
- Current measurement range: 0,3...15 A (AC / DC, set by jumper)
- Resolution: 10 bits
- Galvanic isolation between the current circuit and 1-Wire bus
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
TSC201 is a compact current sensor with a 1-Wire interface and an input range up to 10 A, designed for AC and DC current monitoring. Its range allows direct measurement of low currents or connection to current transformers (CTs) with 10 A secondary output for accurate indirect monitoring of higher currents.
- 1-Wire protocol current transmitter
- Current measurement range: 0,1...10 A (AC / DC)
- Measuring accuracy: ± 1 %
- Resolution: 0,01 A
- Galvanic isolation between the current circuit and 1-Wire bus
- Power supply: 4,0…5,5 V
- Excellent long-term stability
- Warranty: 3 years
- Input: Pt100 (2-, 3-, 4-wire)
- Measurement range: -200...+850 °C
- Resolution: 24 bits
- Very low current consumption
- No external power supply needed
- Warranty: 3 years
- Connection: RJ-11
TSM400-1-TH is a digital temperature and humidity sensor with a 1-Wire interface. Suitable for monitoring air quality of server rooms, data centers, offices and stores.
- Temperature measurement range: -20…+60°C
- Accuracy (min): ± 0,4 °C (in -10…+60°C range)
- Accuracy (max): ± 0,6 °C (in -20…+60°C range)
- Resolution: 0,1 °C
- Relative humidity measurement range: 10 to 90% (non-condensing)
- Accuracy (min): ± 3.0 % RH (in 20…80 % RH range)
- Accuracy (max): ± 5.0 % RH (in 10…90 % RH range)
- Resolution: 0,1 %RH
- Excellent long-term stability
- The unique 64-Bit serial number for multi-sensors support
- Ingress protection: IP20
- Operating voltage range: 4,5…26 VDC
SPECTRO-2 has 2 contrast sensors, allowing it to calculate other parameters.
- Input: 2x thermocouples - J, K, T, N, E, B, R, and S
- Output: Modbus RTU – RS-485
- Resolution: 24 bits with DSP processing
- Working isolation voltage: 1500 Vrms
- Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
- DIN rail mounting
- Power supply: 5…30 Vdc
- Warranty: 3 years
- Digital inputs: 2
- 1-Wire input (up to 8 sensors)
- RS-485 input (up to 8 sensors)
- Analog inputs: 4 (2 x 0...10 VDC, 2 x 0...10 VDC / 4...20 mA, WEB control)
- Relay outputs: 4 (NO/NC)
- Setup via USB or SMS
- Data logger for up to 52 000 records
- Webserver
- Periodical upload of data logger file to a remote HTTP server
- HTTP Post, HTTP API
- Communication: 4G-LTE, 3G-WCDMA
- SMS alarms (up to 5 numbers)
- E-mail alarms (up to 5 recipients), SMT with TLS support
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- 4G LTE supported frequency bands:
- B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/B19/B20/B25/B26/B28/ B66/B34/B38/B39/B40/B41
- 3G supported frequency bands:
- B1/B2/B4/B5/B6/B8/B19
- 2G supported frequency bands:
- B2/B3/B5/B8
- M2M communication protocols: MQTT, HTTP API (XML or JSON)
- Setup via WEB interface through the USB or remote setup with HTTP API or SMS commands
- Digital inputs: 2 “dry contacts”
- 1-Wire input (up to 4 sensors)
- Analog inputs: 2 (0...60 VDC)
- Relay outputs: 2 (NO/NC)
- E-mail alarms (up to 5 recipients), SMTP with TLS support
- SMS alarms (up to 5 recipients)
- GSM Geolocation (optional)
- Firmware update over the air (FOTA)
- Operating temperature: -20...+55 °C
- Supply: 10…28 VDC
TCG210-4 is a battery-powered 4G parcel temperature and humidity logger with fallback support for 2G communication. The device is compatible with HTTP/HTTPS API protocols, making it suitable for modern IoT applications. It periodically sends HTTP/HTTPS POST requests to a remote server, containing a status file in JSON format and the most recent logged data in CSV format.
- Global connectivity - Quad-band 4G LTE Cat.1 with 2G fallback ensures reliable operation worldwide.
- Battery-powered autonomy - Operates for months without external power, ideal for parcel monitoring and remote applications.
- Intelligent power management - Advanced sleep mode significantly extends battery life.
- Flexible configuration - Easy setup via Wi-Fi, SMS, or HTTP API.
- Real-time alerts - Instant SMS alarm notifications to up to five phone numbers.
- Integrated sensing - High-accuracy temperature and humidity sensor for critical parcel monitoring.
- Large data storage - Onboard memory for up to 70,000 logged records.
- Seamless IoT integration - Periodic HTTP/HTTPS POST with current status in JSON format.
- Data export - Automatic upload of logged data in CSV format to a remote server.
- Remote management - Full device control through HTTP API commands.
- Future-proof - Firmware update over Wi-Fi or 4G LTE keeps the device always up to date.
- Compact and lightweight - Designed for easy deployment in parcel logistics, cold chain transport, and warehousing.
- Safe for air transport - Powered by a compliant Li-SOCl₂ battery (IATA DGR, UN 3091, PI970 Section II), suitable for air shipment.
- Input voltage range: 0…264 Vac or 0…370 Vdc
- Input frequency: 0…60 Hz
- Input resistance: >2.4 MOhm
- Output: Modbus RTU – RS-485
- Resolution: 24 bits with DSP processing
- True RMS measurement
- Working isolation voltage: 1500 Vrms
- Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
- DIN rail mounting
- Power supply: 5…28 Vdc
- Warranty: 3 years
- Voltage being detected in one of two ranges: 85...250 VAC or 170...250 VAC (settable by jumper)
- Galvanic isolation between the input voltage and output (OC)
- Low temperature drift
- Supplied by detected voltage
- Warranty: 3 years
- The Si-83 tank pump is perfect for residential A/C (up to 20 kW) and heating units (up to 40 kW)
- Max discharge head: 5,4 m
- Max pressure: 5,7 m
- Tank volume: 2 L
- Automatic turn on specific level in tank
- Overdraft level safety switch
- Stainless steel motor shaft
- Protection class: IP44
- Max condensate temperature: 55 °C
- Max condensate acidity: pH > 2,5 (Gas condensing boilers)
- Quick installation with mobile app
Adding preset counter Type 886.
- Display 3- or 5-digit, 4mm
- Protection class IP30
- Universal airflow monitor with Safety Integrity Level 1 (SIL1) according to IEC 61508/IEC61511 (alternatively device with SIL2 certification available)
- With switching output suitable for control cabinet installation
- Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
- Large measuring range from 0.1 ... 30 m/s, quick and easy commissioning
- Example areas of application: Monitoring heating registers, air curtain systems, dampers, fans, DDC
- Ambient temperature and humidity transducer with 4...20 mA output
- Integrated sensors
- Calibration certificate is included
- Economical
- Ambient temperature and humidity transducer with 4...20 mA output
- Stem length 700 mm
- Calculated values: dew point temperature, absolute humidity, specific humidity, mixing ration, specific enthalpy
- Display with two periodically changed shown values (can be switched off)
- Integrated sensors
- Calibration certificate is included
- Programmable output
- Low temperature inertia
- For use in non-aggressive environment
- 3 year warranty
- Analog gas detector MC for connection to DGC, MSC, WSB or any compatible gas detector
- Reliable self-monitoring: Integrated watchdog
- Precise signal: 4–20 mA (2–10 V) output for easy system integration
- Ethernet connection
- Analog outputs: 2 (0...20 mA / 4...20 mA / 0...24 mA / 0...5 V / 0...10 V)
- Digital outputs: 4 (PWM / ON/OFF)
- Relay outputs: 2 (NO/NC)
- Modbus TCP/IP support
- Webserver
- XML/JSON, HTTP API commands
- SNMP alarms (up to 5 recipients)
- Operating temperature: -10...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
Astronomical digital clocks RAT-TPA1B are applied for switching on and off the lightning or other electrical receivers in accordance to sunset and sunrise with an option to program a night break, which means a temporary switching off of the receivers for savings purposes
- 52 programs, holiday mode
- Automatic summer/winter digital clockover
- Automatic transfer of weekdays
- Sealable cover of the front panel, easy setting by 4 buttons
- Backlighted LCD display (can be turned off)
- 10-year power reserve (internal lithium battery which can protect real time clock and all the settings when the electric power supply is off)
- Number and type of contacts: 1 CO
- Rated load: 16 A / 250 V AC
- Direct mounting on 35 mm rail mount acc. to EN 60715
- Compliance with standards EN 60730-1, EN 60730-2-7, Directive RoHS
The ATEX IBC Heater series is a safe, efficient, and customizable heating solution for IBC containers located in hazardous areas. IBC heaters are used for protection against frost, temperature maintenance and process heating in a wide range of industries.
Technical Specifications:
- Heats IBCs from -40°C to +200°C for steel, +80°C for plastic, ideal for industries like oil, gas, and pharmaceuticals.
- Fits standard 1000-liter IBCs, optional insulating lid, for indoor/outdoor use, IP65/I dust and water jet protection.
- Ready to use, fully configured with EC-type certificate, no additional acceptance needed.
- Variable voltage, power, and size options, for temperature classes T6 to T3.
- Compatible with optional ATEX controller for temperature management.
- Nominal voltage: 230 VAC*
- Nominal power: 2400 W (container heater) (insulation lid) without heating
- Max. operating temperature: +180°C / +200°C (steel IBC-Container), +80°C (plastic IBC-Container)
- Temperature class: T6, T5, T4, T3 (depending on temperature setting limiter)
- Electrical connection terminal boxes for network (EX-e) / sensor (EX-i)
- Protection class: IP65/I
- Zones 1/2 (gas); 21/22 (dust)
- Sensors: 2xPt100 (EX-i, EX-e)
- Weight: 30kg (container heater), 5kg (insulation lid)
- Measures ambient air pressure
- Measurement range: 600...1100 hPa
- Operating temperature: -30...80 °C
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
- TOR-80 is designed to measure the dielectric strength of transformer oil and other dielectric fluids according to IEC 60156, ASTM D877 and ASTM D1816
- Can work autonomously or transfer results to a PC, create a local database, generate reports, plot graphs and print results
- There is software for the implementation of standard and custom measurement procedures
- Max output voltage: up to 80 kV, sinusoidal
- Output voltage measurement accuracy ± 2 %
- Voltage increase rate: 0,1 to 5 kV/sec (adjustable)
- Resolution of output voltage indication: 100 V
- High voltage timeout after breakthrough: 4 ms typical (10 ms max)
- Operating voltage: 85 – 264 V a.c. (48…63 Hz)
- Power requirement: 250 VA max
- Measuring cell volume for oil: 500 cm3
- Temperature range of testing oil: 0…100 °C
- Unit operating conditions:
- Temperature: 0…50 °С
- Storage temperature: -20… 60 °С
- Relative humidity: Up to 90 % (without condensation)
Moisture measuring of sand, minerals, clay, grain, foodstuffs, sawdust, ores, sewage sludge. During operation, the sensor requires nothing but a power supply and a display or a controller that can receive the measurement signal. The BMMS sensor is designed for applications in which no multi-part systems are to be used but still the highest precision is required. Due to the in-process calibration, all potential interference from the sensor installation is directly compensated for.
- Capacitive moisture measurement
- Temperature range of measuring material: 4...50 °C
- Direct measured values transfer from the sensor
- Calibration is made directly at sensor, beyond the process
- Capacitive moisture measurement
- Up to 16 sensors per signal processing unit
- Temperature range of measuring material: 4...80 °C
- Measured value transfer: Profibus DP or analogue standard signal (e.g. 4...20 mA) optional
- Continuous measurement or batch operation
The VA702 is a Volt/mA/TC Calibrator, designed as a source and measurement tool. It measures or outputs a 0 to 24 mA DC current loop, 0 to 20 V DC voltage, and supports thermocouple temperature measurements (model dependent). Note: The calibrator cannot measure and source simultaneously.
- Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
- Storage temperature: -40℃ to 60℃
- Operating temperature: -10℃ to 50℃
- Operating altitude: Up to 2000 meters
- Temperature coefficient: ±0.01% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
- Relative humidity:
- 95% up to 30℃
- 75% up to 40℃
- 45% up to 50℃
- 35% up to 55℃
- Power requirements: 6 x AAA batteries
- Size: 204mm (L) x 99mm (W) x 46mm (H)
- Weight: 460g (including battery)
The VA710 Thermocouple Calibrator is a high-accuracy handheld instrument for calibrating thermocouple instruments. It measures or simulates 8 types of thermocouples (°C or °F) and millivolts. It cannot measure and source simultaneously.
- Measure or simulate: Millivolt and 8 types of thermocouples (°C or °F)
- Display: Large 5-digit LCD with full-angle visibility
- Accuracy: Max. up to 0.3℃ and 0.025% for mV
- Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
- Temperature coefficient: ±0.02%/℃ (from 0℃ to 18℃ and 28℃ to 50℃)
- Storage temperature: -40℃ to 60℃
- Operating temperature: 0℃ to 50℃
- Operating altitude: Up to 3000 meters
- Relative humidity:
- 95% up to 30℃
- 75% up to 40℃
- 45% up to 50℃
- Shock: Random 2g, 5Hz to 500Hz
- Safety: 1 meter drop test
- Fuse: F 0.125A/250V
- Power supply: 6 x AAA 1.5V batteries or Standard jack for external power supply
- Size: 205mm (L) x 98mm (W) x 46mm (H)
- Weight: 472g (including battery)
Universal calibrator-meter Inmel 60 for automation tuning.
Carbon dioxide (CO2) and temperature transmitter with a display CDT2000 Duct. The device is designed for measurement of air parameters in ventilation channels.
- CO2 range 400...2000 ppm
- Temperature range 0...50 °C
- To measure carbon dioxide and temperature in air and neutral gases ranges 0…5000 ppm, 0...50 °C
- Configuration with keypad or software: measuring ranges, units, outputs settings
- Optional with display or without display
- Galvanic isolation all the ways
- On request range increase up to 0...20 000 ppm
- Carbon dioxide (CO2) range: 0… 2000 ppm or 0…4000 ppm (selectable)
- Stable long-life optical NDIR sensor
- Response time: < 2 min
- Output: 0...10 V arba 4...20 mA
- Ambient temperature: 0...+ 50 ºC
- Supply: 24 VAC/ VDC
- Protection class: IP 30
- Dimensions: 98 x 98 x 33 mm
- Application: offices, hotels, convention centers, apartments, shops, etc.
- To measure carbon dioxide in air and neutral gases range 0…5000 ppm
- Configuration with switches or software: measuring ranges, outputs settings
- Optional with display or without display
- Ambient and duct models. Duct model available only without display
Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.
- Carbon dioxide (CO2) range: 400...2000 ppm
- Humidity range: 0...100 %
- Temperature range: 0...50 °C
- Stable long-life optical NDIR gas sensor
- Range 400...5 000/10 000/50 000 ppm CO2
- Resolution 10 ppm CO2
- Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
- Remote probe option
- Stable long-life optical NDIR gas sensor
- Range 400...5 000/10 000/50 000 ppm CO2
- Resolution 10 ppm CO2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Remote probe option
- NDIR gas sensor
- Range: 0...10 000 ppm CO2
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: 0...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC as options
- NDIR gas sensor
- Range: 0...50 000 ppm CO2 (up to 100 % CO2 on request)
- Resolution: 0.01 % vol.
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -25…+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
Carbon dioxide transmitter CMT is designed for CO concentration measurement. The transmitter is used to control interior ventilation systems.
- CO range 0...300 ppm
- Electrochemical (CO) and optical NDIR (CO2) gas sensors
- Range: 0...100 ppm CO, 0...10000 ppm CO2
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Operating temperature: -20...+50 °C
- Supply: 24 VDC/VAC
- Protection class: IP65
- Electrochemical gas sensors
- Range: 0...100 ppm CO, 0...20 ppm NO2
- Resolution: 1 ppm CO, 0,1 NO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Operating temperature: -20...+50 °C
- Supply: 24 VDC/VAC
- Protection class: IP65
- Stable long-life electrochemical gas sensor
- Range 0....1000 ppm CO
- Resolution 1 ppm CO
- Default alarms at 25 ppm / 35 ppm CO
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Stable long-life electrochemical gas sensor
- Range: standard 0....200 ppm CO, maximal 0...1000 ppm CO
- Resolution 1 ppm CO
- Default alarms at 25 ppm / 125 ppm CO
- Outputs 2 x relays with switch-over contacts
- Visual and acoustic alarms
- Long-life electrochemical cell
- Range 0....1000 ppm CO
- Resolution 1 ppm CO
- Outputs 4...20 mA / 0...10 V, RS-485