- 1-Wire protocol temperature and humidity sensor
- Temperature measurement range: -20...+60 °C
- Humidity temperature range: 10...90 %RH
- Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (10...90 %RH) / ±0,4 °C (-10...+60 °C) / ±1 °C (-20...+60 °C)
- Resolution: 14 bits for temperature, 12 bits for humidity
- Long-term stability
- Warranty: 3 years
- 1-Wire protocol temperature and humidity sensor
- Temperature measurement range: -20...+60 °C
- Humidity temperature range: 10...90 %RH
- Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (10...90 %RH) / ±0,4 °C (-10...+60 °C) / ±1 °C (-20...+60 °C)
- Resolution: 14 bits for temperature, 12 bits for humidity
- Long-term stability
- Warranty: 3 years
- Connection: RJ-11
- RS-485 protocol temperature and humidity sensor
- Temperature measurement range: -20...+60 °C
- Humidity temperature range: 5...95 %RH
- Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (5...95 %RH) / ±0,4 °C (-10...+60 °C) / ±0,6 °C (-20...+60 °C)
- Resolution: 14 bits for temperature, 12 bits for humidity
- Long-term stability
- Warranty: 3 years
- Connection: RJ-45
- Digital pulse counter - tachometer ECH4400
- Count inputs: 2 channels (max 50 kHz, 5…30 V pulses), can be selected as PNP or NPN input
- Counting frequency: (20, 50, 100, 500, 1000, 5000) Hz, (10, 20, 30, 40) kHz
- Control outputs: 2 relay NO / NC 250 V, 2 A
- SSR outputs: Open collector output (Max.: 30 VDC, 50 mA)
- RS485 Modbus communication interface (custom ordered)
- Power supply: 90…250 V AC; 10…30 V DC; 8…24 V AC (custom ordered)
- Auxiliary supply output: 12 VDC, max 50 mA
- Ambient temperature: 0…+50 °C
- Case protection: front panel IP65, rear panel IP20
- 1-Wire protocol temperature sensor
- Temperature measurement range: -40...+85 °C
- Accuracy: ±0,5 °C (-10...+85 °C) / ±2 °C (-40...+85 °C)
- Resolution: 12 bits
- Very low current consumption
- Warranty: 3 years
- Protection class: IP65
- 1-Wire protocol temperature sensor
- Temperature measurement range: -40...+85 °C
- Accuracy: ±0,5 °C (-10...+85 °C) / ±2 °C (-20...+85 °C)
- Resolution: 12 bits
- Very low current consumption
- Warranty: 3 years
- Connection: RJ-11
- Modern, simple and user-friendly service
- Communication interfaces: RS-485 Modbus Slave, Modbus TCP Slave and optionally Ethernet
- FTP server (available in controller versions with Ethernet interface)
- Selection of PID parameters for any unit
- For easy programming and devices configuration, LUMEL offers one common LPCon software
- Parameter logging on SD card
Duct temperature transducer with 4...20 mA output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Calibration certificate is included.
Duct temperature transducer with 0...10 V output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Output temperature range is user adjustable. Calibration certificate is included.
These jacket heaters enable the comfortable and effective way to heat up IBC containers and other tanks. Low energy losses, even heat distribution. Can be used for various products: water, oils, diesel fuel, resin, Vaseline, wax, lanolin, fats, butters, Ghee, glue and adhesive. Can be used with insulation lid.
- 1, 2, or 3 thermostats adjustable from 0…+90 °C
- Teflon coated Polyester Material
- Standard size IBC 1000L (4400 x 1000 mm)
- Durable, lightweight design with quick release buckles
- 3 m connection cable
- Protection class IP40 (Optional IP54)
- Warm-up duration approx. 48h (1000L drum with water starting from +15º C to +50º C with 2x1000 W heaters and isolation lid)
- Warm-up duration approx. 48h (1000L drum with water starting from +15º C to +70º C with 3x1000 W heaters and isolation lid)
The silicone heater increases flow from LPG cylinders. By adding heat directly to the cylinder, the silicone heater maximizes LPG vaporization, ensuring that your supply lasts longer and works better, even under high demand.
- Dimensions: 890mm x 120mm
- Voltage: 230V
- Wattage: 500W
- Compatible with 22kg and 33kg standard size gas bottles
- Spring mounted for perfect cylinder fit
- Features a 40°C limiter and a 55°C safety fuse with manual reset
Utilizing unique dual-sensing technology, the device combines electromagnetic induction with an integrated ultrasonic sensor to provide highly accurate detection of both liquid level and flow velocity. Specifically optimized for partially filled pipes, open channels, and gravity-fed systems, the unit achieves an outstanding accuracy of ±1–2% of the actual flow rate.
- Internal pipe diameter: DN80…DN600
- Flow velocity (min. / max.): 0,46…7,5 m/s
- Accuracy: ± 1…2 % of actual flow (depends on flow profile and level detection)
- Process Temperature: 0…+70 °C
- Coating materials: hard rubber
- Maximum working pressure: No pressure (gravity flow) or 10 bar if pipe is full
- Output signal: 2× pulse / flow switch (max. 400 Hz), 4 ... 20 mA, 1× RS485 interface (Modbus / M-Bus protocol), M-Bus, HART, Ethernet module (TCP/IP, integrated web server)
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Data archiving on a micro-SD card
- Process connections: flange
- Maximum ambient temperature: 55 °C
- Power supply: 24 V AC / DC, 230 V AC
- Protection class: IP68 for sensor, IP65-IP68 for transmitter
FLOW 55 datasheet [EN]
FLOW 38 MID version with certification, allowing the flow meter to be used for utility metering. FLOW 38 MID is certified for use with drinking water. The FLOW 38 MID electromagnetic flow rate meter is a precise measuring device designed to measure the flow of electrically conductive liquids. The electronic unit (display) can be connected directly to the body (rotatable up to 350° for convenient viewing). Various process connection versions are available. A wide selection of materials for the internal surfaces in contact with the process medium allows the device to be adapted to various liquids.
- Internal pipe diameter: DN10…DN400
- Flow velocity (min./max.): 0,1…12 m/s (R40, R50)
- Accuracy: 0.2% in the 1:100 range, 0.5% in the 1:200 range
- Maximum medium temperature depending on the inner coating: 150 ℃
- Coating materials: rubber, teflon, ceramic
- Maximum working pressure: up to 16 bar
- Output signal: pulse, 4-20 mA, RS485 (Modbus RTU/ M-bus)
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Process connections: Flange, Thread
- Maximum ambient temperature: 50 °C
- Power supply: 24 VAC/VDC, 110... 230 VAC
- Protection class: IP65, IP67, IP68
The FLOW 38 electromagnetic, bidirectional flow and flow rate meter is a precise measuring device designed to measure the flow of electrically conductive liquids. Due to the wide range of configurations available, this device is used in many industries. The electronic unit (display) can be connected directly to the body (rotatable up to 350° for convenient viewing) or connected via a cable up to 30 meters long. Various process connection versions are available. A wide selection of materials for the internal surfaces in contact with the process medium allows the device to be adapted to various liquids. FLOW 38 is certified for use with drinking water. There is also a version of the Flow38 with MID certification, allowing the flow meter to be used for utility metering.
- Internal pipe diameter: DN4-DN600
- Flow velocity - bidirectional (min./max.): 0.2…12 m/s
- Accuracy: 0.2% in the 1:100 range, 0.5% in the 1:200 range
- Maximum medium temperature depending on the inner coating: 150 ℃
- Coating materials: rubber, Rilsan, Teflon, ceramic
- Maximum working pressure: up to 100 bar
- Output signal: pulse, 4-20 mA, RS485 (Modbus RTU/ M-bus), Modbus TCP/ IP, HART
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Process connections: Flange, Sandwich, Food grade fittings (clamp), Thread
- Maximum ambient temperature: 55 °C
- Power supply: 24 VAC/VDC, 110... 230 VAC
- Protection class: IP65, IP67, IP68
The FLOW45 electromagnetic flowmeter is equipped with a lithium battery, so it does not require an external power supply. The device has high accuracy in terms of full flow rate. Before each measurement, automatic diagnostics of all functions and parts necessary for proper measurement are performed. The device has a built-in empty pipe test and if there is no full flow, it will invalidate the entire measurement, as well as assess the flow direction and record the appropriate data.
- Internal pipe diameter: DN10…DN200
- Flow velocity (min. / max.), bidirectional: 0,2…12 m/s (1/60)
- Accuracy: 1 % for 1…10 m/s
- Maximum medium temperature depending on the inner coating: 150 ℃
- Coating materials: rubber (hard, soft, drinking water certified), Teflon, ceramic, Rilsan
- Maximum working pressure: up to 100 bar
- Output signal: pulse, RS485
- GSM data transmission module
- Data archiving on a micro SD card
- Process connections: flange, thread, sandwich, food grade
- Maximum ambient temperature: 5…55 °C
- Power supply: replaceable lithium battery (last up to 5 years) / external (12 V DC, max. 500 mA)
- Protection class: IP65, IP67, IP68
Absolute encoder AC58. Vibration- and overload-resistant. Wide range of appliance.
- Size Ø58, axis - Ø10mm
Incremental encoder RI36. Vibration- and overload-resistant. Wide range of appliance.
- Size Ø36.6 mm, axis - Ø4/6/8/10 mm
Incremental encoder RI38. Vibration- and overload-resistant. Wide range of appliance.
- Size Ø39 mm, axis - Ø6 mm
Incremental encoder RI42. Vibration- and overload-resistant. Wide range of appliance.
- Size Ø40 mm, axis - Ø6 mm
Incremental encoder RI76. Vibration- and overload-resistant. Wide range of appliance.
- Size Ø76 mm, ašis - Ø15...42 mm
Incremental encoder RX70. Vibration- and overload-resistant. Wide range of appliance.
- Size Ø69mm, axis - Ø10mm
- Certified for ATEX zone
- Complies to category II 2 gas and dust
- IP65/IP66 protection class
- Certified: II 2 G/D E Ex d II T4/T6 IP65/IP66 135 °C bz. 85 °C
- Universal industrial rotary encoders
- Up to 40,000 steps
- High degree of signal accuracy
- Ingress protection up to IP67
- Fits most applications due to many flange and connection options
- Suitable for high shock loads
- Typical fields of application are machine tools, CNC axes, Packaging machines, Motors/ drives, Injection molding machines, Sawing machines
- Operating temperature up to 100°C (RI 58-T)
- Analog inputs: 6 (0...10 VDC / 4...20 mA, configurable, isolated)
- Digital inputs: 4 (isolated)
- RS-485 input (up to 24 Modbus RTU registers)
- Memory: 70 000 values
- Ethernet connection
- Modbus RTU to Modbus TCP conversion
- Webserver
- Periodical upload of data logger file to a remote HTTP server
- HTTP Post, HTTP API
- SNMP alarms (up to 5 recipients)
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- Ethernet connection
- Analog inputs: 2 (0...10 VDC)
- Digital inputs: 2
- Relay outputs: 2 (NO/NC)
- 1-Wire input (up to 8 sensors)
- Memory: 70 000 values
- Modbus TCP/IP support
- Webserver
- XML/JSON, HTTP API commands
- SNMP alarms (up to 5 recipients)
- E-mail alarms (up to 5 recipients)
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- Ethernet connection
- Digital inputs: 1
- Relay outputs: 8 (NO/NC)
- Webserver
- XML and HTTP API commands
- E-mail alarms (up to 5 recipients), SMTP with TLS support
- SNMP alarms
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...14 VDC
- Ethernet connection
- Modbus TCP/IP
- Digital inputs: 4
- 1-Wire input (up to 8 sensors)
- Analog inputs: 4 (0...60 VDC)
- Relay outputs: 4 (NO/NC)
- Configurable inputs
- Webserver
- HTTP Post, HTTP API
- E-mail alarms (up to 5 recipients), SMT with TLS support
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- Air flow monitor with switching output for control cabinet installation
- Safely and reliably monitor hot air flows up to 400°C
- Sensitive response behaviour
- Large measuring range (0.1...30 m/s), simple and fast commissioning
- Areas of application: Monitoring of heating coils, drying plants, industrial ovens, granulate dryers, surface technology plants, thermoprocess technology
- Flow monitoring with SIL1 certification according to IEC 62061 (corresponds to Performance Level c according to EN ISO 13849-1)
- Can be used in ATEX zones 1 and 2 in conjunction with 2 Zener barriers supplied
- Large measuring range from 0.1 to 30 m/s with media temperatures from 0°C to 60°C
- With switching output suitable for control cabinet installation
- Developed for demanding industrial applications, IP40
- Example areas of application: Flow monitoring in paint shops, paper factories and research facilities
- Air flow monitor for monitoring air flow in ATEX zones 1 and 2 (optionally additionally with SIL1 or SIL2 certification)
- With switching output (1 NO/ 1 NC) for control cabinet installation
- Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
- Large measuring range (0.1...30 m / s), simple and fast commissioning
- Example areas of application: Monitoring heating registers, air curtain systems, dampers, fans, DDC, industrial furnaces, granulate dryers
- Exd fire-resistant thermocouple temperature sensors are designed for temperature sensing in explosive atmospheres.
- Ranges: -40...+800°C; -40...+1200°C; -40...+700°C
- Outputs: TC, 4...20 mA
- Measurement distance: 0,5…2 m
- Accuracy: ± 0,5 °C
- Measurement speed: 0,7…2 m
- Software: DERMALOG Fever Detection (PC required)
- Interface: USB 3.0
- SDK: .Net / C / C++ / (Java coming soon)
- Measurement speed: 0,6 s (up to 700 people per hour)
- Integrated sensors: 5
- IR thermal array, range: 0...100 °C (± 0,3 °C)
- Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
- Relative humidity sensor, range: 0...100 % (± 3 %)
- Vibration sensor (for sabotage detection), range: 0,25...5 G
- Distance sensor, resolution: 1 mm
- Dew point calculation
- Relay inputs: 2
- Relay outputs: 2
- LED indication, buzzer (85 dB)
- Communication: Ethernet (10/100)
- Connector (RJ45) for connection of other Kentix devices
- Webserver
- Software: remote connection with AlarmManager-PRO
- E-mail, SNMP alarms, Rest API
- SD card slot (to save pictures, card up to 128 GB)
- PoE
- Optional: RFID reader
- Optional: wall bracket, cable
Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.
- Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
- Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
- CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
- Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
- Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
- Air quality (VOC) measuring range: 0…100 %
- Data output: galvanically separated RS-485 Modbus RTU interface
- Variants: with / without LCD display
- One sensor covers about 30 m² of room area
- Power supply: 24 V ac/dc (200 mA)
- Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
- Suitable for ATEX Zones 2 and 22
- Stable long-life photoacoustic or optical NDIR sensor
- Range: 0...10 000 ppm / 0...40 000 ppm / 0...5 % vol (0...100 % on request)
- Resolution: 1 ppm / 10 ppm / 0.01 % vol. CO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+60 °C; 0….100 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...300 or 0...1000 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
Thermal mass flow sensor for compressed air and gases VA 500
- 4...20 mA, pulse and a Modbus RTU (RS 485) interface as standard
- Optional: Interfaces such as Modbus TCP (Ethernet), PoE, M-Bus
- Optional: Bi-directional measurement
- Pressure tight up to 50 bar
- Temperature range up to 110 °C
- Protection class IP65
- Suitable for gas velocities up to 224 Nm/s
- Integrated display for showing the measured values
- Can be used from 1/2" up to 40", larger diameters on request
- Easy installation under pressure
- Settings can be changed via the display
- Main counter reading can be reset via the display
- Calorimetric measuring principle
- Units freely selectable via keys at the display
- Display shows 2 values at the same time, twistable by 180 ° degree
- Integrated Modbus interface enables connection control systems, SCADA
- M-Bus (optional)
- Analog output 4...20 mA
- Pulse output (galvanic isolation)
- High measuring accuracy (ideal for leakage measurement)
- Applications of flue gas analyzer Si-Ca 130: for commercial and residential boilers and water heaters
- Detectable gases: O2, CO, CO2, NO, NOx
- Up to three gas sensors
- CO measurement up to 8000 ppm
- Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation)
- Color display screen with buttons
- Communication: Bluetooth (mobile App), remote printer
- Measurement storage: smartphone
- Predictive maintenance with estimated sensor life and calibration reminders
- Protection class: IP42
- Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
- Operating temperature: -5…+45 °C
- Sensor protection by pump stopping
Fluid level alarm Elcluwo 111S, designed for usage with conductometric probes for fluid level alarm and control.
Technical specifications
- One or more level control
- Switch output 2A, 250 VAC
- Probe supply from isolated ~12 V source
- Adjustable sensitivity
- Available modes – flooding, drainage, dry flow, overflooding
- Pump or valve control
- Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
- Mounting on standard rail (35 mm)
Fluid level alarm Elcluwo 112S, designed for usage with conductometric probes for fluid level alarm and control, depth pump protection.
Technical specifications
- One or more level control
- Switch outputs: switching + NO 2 A / 250 VAC
- Probe supply from isolated ~12 V source
- Adjustable sensitivity
- Available modes – flooding, drainage, dry flow, overflooding
- Pump or valve control
- Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
- Mounting on standard rail (35 mm)
- One or more level control
- Switch outputs: switching + 3 x NO 2 A / 250 VAC
- Probes: galvanically isolated, max. 2mA, 5V~ 100 Hz
- Adjustable sensitivity
- Available modes – flooding, drainage, dry flow, overflooding
- Pump or valve control
- Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
- Mounting on standard rail (35 mm)
- Supply: 230 VAC / 24 VAC
- One or two level control
- Switch outputs – switching + 5 x NO, 2A / 250 VAC
- Probes: galvanically isolated, max. 2uA, 5V~ 100 Hz
- Adjustable sensitivity
- Available modes – filling, draining, dry flow, overflow, two/three pump control and others
- Valve or gate control
- Adapted for work with various probes – SKS 401, 201, 101, SW-01 and others
- Mounted on standard rail (35 mm)
- Supply: 230 VAC / 24 VAC
The FPT 8236 pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.
- Measuring range: 0.5...0.5 to 0...100 bar (-5...10 to 0...1500 psi)
- Output signal: 4...20 mA, 0...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
- Accuracy at 25°C typically: ± 0.5 % FS typ.
- Membrane in Duplex steel 1.4462
- Pressure connection: G1/2” male, flush membrane
- Media temperature –10... +125 °C
- Ambient temperature: –10...+125 °C
- Applications: Machine tools, Food Industry, Process technology, Water treatment, Hydraulics
- Gas measuring, monitoring and warning controller (Multi-Sensor-Controller MSC) for reliable detection of combustible, toxic and refrigerant gases
- Flexible control: 3 relays (SPDT, potential-free, 250 V)
- Intelligent Communication: RS-485 interface with DGC and Modbus protocol
- Precise signal transmission: 4–20 mA input and output for seamless system integration, up to 3 sensors including remote
- Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
- Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
- Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
- Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
- G-7 is designed for moisture measurement of grain
- Moisture measurement range: 9...30 %, depends on grain type
- Built-in calibrations for barley, coffee, corn, flax, hay, oats, pasta, rapeseed, rough rice, rye, sorghum, soybeans and wheat
- Built-in temperature correction over the range of 0...70 °C
- Programmable offset to match elevator
- Stores up to 150 accumulated readings in user-defined batches by grain
- Displays the average and highest readings, standard deviation, co-efficient of variance oh stored readings
- Built-in connector accepts any Delmhorst electrode
- Built-in calibration check
- Audible, adjustable alarm
- Size: 180 x 150 x 140 mm
- Weight: 1800 g
- Rugged construction ensures years of reliable use
- Supply: 9 V battery
- 1-year warranty
- Data converter which connects reader in safe zone with network switches and temperature cables/spears in dangerous zone
- Input: 4 x temperature cables (from switches GWNET11 and cables GWSL 1100 or GWSL 2100)
- Output: Modbus RTU, RS-485
- Reads data from 68 individual temperature cables and spears
- Supply: 230 VAC / 115 VAC
- Protection class: IP66
- Certificates: IECEx, ATEX
- Works as a multiplexer, enabling 4 additional temperature cables or spears to be connected to GWAB11 converter
- Another GWNET11 can be connected in parallel, further expanding inputs of GWAB11 by 4
- Operating temperature: -20...+50 °C
- Protection class: IP66
- Certificates: IECEx, ATEX
Automatic portable solid state particle (dust) meter EMIOTEST 3114 is designed for periodic solid state particle concentration measurement in closed channels, i.e. flue gas, and perform other functions:
- Periodic measurement of solid state particle concentration in stationary sources of emission
- Solid state particle concentration measurement in gasses
- Testing of dust removal equipment
- Gas flow rate measurement
- Calibration and periodic control of automatic systems (AMS) by measuring the emission and mass stream of dust
- Dioxins, furans, PAH, mercury concentration measurement
- Heavy meal, HCL, HF concentration measurement
Kuhlmann Ground Thawing Blankets are durable and weatherproof, designed to thaw frozen ground and soil, pipes, and protect equipment from freezing. They also work as curing blankets for various construction purposes.
Technical specifications:
- Durable PVC materials.
- Fixed temperature (70°C).
- 2-meter power cable.
- Special sizes produced upon request.
- IP67 Class.
- In normal conditions the mat thaws up to 30 cm of soil in 24 hours - or up to 60 cm in more sandy soil/ground.