Temperature transducers P4141, P4121, P4151, P4131, P4161, P4171, P4191 with 4...20 mA output and Pt1000 input.

P4121 – P4171 class transducers are designed to convert RTD Pt1000 (3850ppm/°C) signal to current. These transducers have 4...20 mA output. RTD sensor Pt1000 is not included.

Temperatre, humidity and pressure meters, loggers Cxxxx, Dxxxx.
Cxxxx are designed for indication (without data logging), Dxxxx indicates and logs listed parameters.

  • Applications of flue gas analyzer Si-Ca 130: boilers, burners, water heaters and furnaces
  • Detectable gases: O2, CO, CO(H2), CO2, NO, Low NO, NOx, Low NOx
  • Up to three gas sensors
  • CO measurement up to 8000 ppm
  • Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation), stack gas velocity
  • Color graphical touchscreen for control
  • Communication: USB, Bluetooth (mobile App), remote printer
  • Measurement storage: 2000 data points + smartphone and PC
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Protection class: IP42
  • Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
  • Operating temperature: -5…+45 °C
  • Sensor protection by pump stopping
  • Designed for the remote monitoring of measurements in industrial, domestic and environmental maintenance applications
  • Typical applications include oil separator alarms, tank surface level measurements, monitoring pumping stations and real estate, and surface and groundwater measurements
  • The device sends alarms and measurement results as text messages either directly to GSM phone or to the LabkoNet server
  • Settings can be easily modified with a GSM phone
  • Analog inputs: 4 units 4...20 mA (passive or active)
  • Digital inputs: 4 units
  • Relay outputs: 2 units
  • Communication: SMS, GPRS
  • Operating temperature: -20...+50 °C
  • Supply: 230 VAC / 12 VDC battery
  • Protection class: IP65

Single-phase commutator – controller RP7. The device can be used or circuit commutations. Can be used for resistive and inductive loads and single-phase motor speed control. Possible control with standard analog signal.

 

Other functions:

  • Load current limiting
  • Soft start
  • Isolated inputs
  • Load current control
  • Fuse failure detection
  • Overload indication

TSH202B is a compact humidity and temperature sensor with 1-Wire interface. It is ideal for use in a variety of applications where space is limited, such as environmental monitoring systems, HVAC control, and more.

  • Fully calibrated digital output
  • Excellent long-term stability
  • A unique 64-bit serial number for multi-sensor systems
  • 3.0% relative humidity accuracy
  • 12-bit resolution for humidity measurements
  • 14-bit resolution for temperature measurements
  • Compact air flow meter with switching output (1 NO)
  • Robust sensor design, protection class IP67 and compact dimensions
  • Switching point continuously adjustable between 0.1...15 m/s (extended measuring range available with RLSW5)
  • Exemplary areas of application: monitoring of fans, heating registers, extraction, soldering and air curtain systems
  • Compact air flow meter with switching output (1 NO / 1 NC) with TÜV type examination (according to DIN EN 61010-1: 2011-07)
  • Robust sensor design, protection class IP67 and compact dimensions, sensitive and fast air flow detection
  • Media temperature up to 60 °C
  • Switching point continuously adjustable between 0.1...30 m/s
  • Exemplary areas of application: Visualization and control of air flows in building automation, filter and fan monitoring as well as in industrial applications such as catalytic converters
  • Compact air flow meter with analogue output (0…10 V & 4…20 mA)
  • Robust sensor design, protection class IP67 and compact dimensions
  • Media temperature up to 70 °C
  • Switching point continuously adjustable between 0.1...30 m/s
  • Exemplary areas of application: Visualization and control of air flows in building automation, filter and fan monitoring as well as in industrial applications such as catalytic converters
  • Flow monitors for water and air flows
  • Robust stainless steel sensor housing for industrial environments
  • Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
  • Switching point sensitive and continuously adjustable both for liquids (0.03 ... 3 m/s) and for gases (0.5 ... 20 m/s)
  • With switching output (1 NO/ 1 NC)
  • Exemplary areas of application: Monitoring of air and water flows, cooling circuits up to 30% glycol content, pump monitoring
  • Warning- and Sensor-Board WSB for digital and analog sensor technology for the precise detection of combustible, toxic and refrigerant gases.
  • Versatile alarm function: Alarm and fault relays (30 V)
  • Intelligent interfaces: RS-485 interface with DGC or Modbus protocol
  • Precise signal transmission: 4–20 mA input and output for reliable communication
  • Flexible: Connection of up to 3 sensors (2 digital)

Compact sensor VA 525 for measuring compressed air or nitrogen inline.

  • 4...20 mA and pulse or a Modbus RTU (RS 485) interface as standard
  • Optional interfaces such as Modbus TCP (Ethernet), PoE, M-Bus available
  • Pressure range up to 16 bar
  • Temperature range up to 60°C
  • For speeds up to 224 Nm/s
  • Integrated display to show the measured values
  • Available from 1/4" to 2''
  • Settings adjustable via the keys of the display
  • Main counter can be reset via the display
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: piston
  • Measured pressure from  -0,6...3,4 to 4...40 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: -25...+125 °C / -40...+125 °C
  • Ambient temperature: -25...+125 °C / -40...+125 °C
  • Protection: IP65
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: piston
  • Measured pressure from 1...10 to 40...400 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: -25...+125 °C
  • Ambient temperature: -25...+85 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, EN60730-1 / EN60730-2-9: Typ 2.B.H
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: membrana
  • Measured pressure from 1...10 to 10...100 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: 0...+80 °C
  • Ambient temperature: 0...+80 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, EN60730-1 / EN60730-2-6: Typ 2.B.H
  • Compact thermostat for shipbuilding
  • ISP version – with capillary tube, ISPT version – without capillary tube
  • Measured temperature from +5...95 °C to +20...150 °C
  • Switching differential: not adjustable
  • Output signal: floating change-over contact
  • Ambient temperature: -30...+70 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H

Contactless counter Colibri 490. With a magnetic drive, activates when a magnet or piece of iron move nearby.

  • Display 6-digit, 4mm
  • Protection class IP66
  • Measurement range: 32…43 °C
  • Measurement accuracy: ± 0,3 °C
  • Measurement distance: 0…5 cm
  • Measurement duration: 1 s
  • Measurement location: forehead
  • Automatic shut-down: 30 s
  • Measurements: 149 x 38 x 42 mm
  • Operating temperature: 10…40 °C
  • Operating humidity: ≤ 85 %
  • Certificates: ISO13485, CE, CFDA
  • Supply: 2 x AAA batteries
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
  • Relay output: 2 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Temperature input: none / Pt100 / Pt1000 / thermocouple
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
  • Relay output: 3 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA (optional: double output)
  • Relay output: 4 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
Microprocessor controller INDU-30 with RS-485 interface for temperature and humidity control in food and other industries. The device is designed for temperature and humidity control in food and other industries (drying, climate chambers, etc.). Humidity measurement is done via psychorometer method. Two programmable inputs are used for temperature sensor connection and one for standard signal 0/4...20 mA. Version for work with thermocouples is also available. The device can log measured values in set time intervals. Data is transferred via RS-485 interface. Control starts in set t..
Microprocessor controller INDU-50 with RS-485 interface for temperature control in thermal processing devices in food industry. The device is intended to be us in boiling pots, vaporizers, grills, climate chambers and so on. Measured values can be logged into the internal memory. Data is transferred via RS-485 interface. Real time clock. Control starts in set time or after set delay. Technical specifications Input: 2 analogue inputs PT-100 (PT-500, PT1000) channel 1: temperature – ‘dry’ thermometer channel 3: temperature – ‘we..

Converter PD8 is designed for data transfer from devices with RS-485 port to Ethernet network. The device comes in two versions. First version is used with network service Real Port. In this case, the Master role is taken by PC with installed software, creating a parallel port. Software (i.e. Lumel Energy) ensures data transfer between devices with RS-485 port and one PC.

 

Second version (parallel bridge with UDP protocol) enables the sextension of data transfer system using additional PD8 converters and local Ethernet network. Variant with two converters or one with many (max. 65) converts is available.

Counter ALC77-B for linear and rotary encoders (batch).

 

Technical specifications

  • 10 kHz input frequency
  • Encoder input (A and B signals)
  • 7-digit LED screen
  • Range -999...9999
  • 2 programmable set points (SPs)
  • 2 switch outputs
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 72 x 72 mm

Counter ALC77-C for linear and rotary encoders (up/down).

 

Technical specifications

  • 600 kHz input frequency
  • Encoder input (A and B signals)
  • 7-digit LED screen
  • Range -999...9999
  • 2 programmable set points (SPs)
  • 2 switch outputs + RS-232
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 72 x 72 mm

Counter ALC77-T for linear and rotary encoders (for tachometers).

 

Technical specifications

  • 5 kHz input frequency
  • Encoder input (A and B signals)
  • 7-digit LED screen
  • Range -999...9999
  • 2 programmable set points (SPs)
  • 2 switch outputs
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 72 x 72 mm

Counter ALC94UNI for linear and rotary encoders (up/down), universal.

 

Technical specifications

  • 600 kHz input frequency
  • Encoder input
  • 6-digit LED screen
  • Range -99999...999999
  • 2 programmable set points (SPs)
  • 2 switch outputs OR RS-232
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 96 x 48 mm
  • Current (AC / DC) transducer T23CT with 4...20 mA output
  • AC/DC current input (single option): up to 50 / 100 / 150 / 200 / 300 A
  • Optional mounting on DIN rail
  • Galvanic isolation
  • Supply: 24 VDC
  • Ambient temperature: -25...+55 °C
  • Protection class: IP65, IP40 for terminals

Data logger PD22. The device is designed for usage in telemetric systems, to be located between a controller and slave devices. PD22 increases the data transfer speed and enables the system to contain more devices. Slave devices are connected to the RS-485 port (Port.1, MODBUS). System controller is connected to RS-485 or RS-232 (Port.2). Data logger has a real time clock and is mounted on 35 mm rail.

Data logger (recorder) AR207 is designed for temperature, standard DC voltage and current and pulse signal logging. 16/8 programmable channels. 4 programmable (NO or SSR) outputs for control and alarm. Color LCD TFT screen. Ethernet (web server function). Internal memory card which can be expanded using USB flash drive. Panel mounting. Multi-channel data presentation. Internal real time clock (RTC). Programming and data access protection.

Data logger for lever measurement DL/N -35%
  • Data logger for level measurement up to 100 m
  • Measuring interval: from 0,5 s to 24 hours
  • Data capacity: up to 500 000 values
  • Interface: RS-485
  • Ambient temperature: -5...50 °C
  • Protection class: IP67
  • Sensor material: stainless steel 1.4435 (316L)
  • Supply: 3,6 V lithium battery
  • Included: 110 m PE cable, RS-485 converter, software
1,185.80 € 770.77 €
Ex Tax: 637.00 €

Recorder HT20 is designed for measurement and logging of ambient humidity and temperature.

  • Especially suitable for server rooms, pharmaceutical and food warehouses, laboratories, museums and greenhouses
  • Logged data is stored in the internal memory and then sent digitally to the user (over Ethernet)
  • Alarms are formed by e-mails, on the webserver, using symbols on screen or via audible alarms
  • HT20 can be powered by the Ethernet network (PoE – Power over Ethernet), additionally ordered
  • FTP, DHCP, SMT, Modbus TCP/IP protocols
  • The MQTT protocol is ideal for communication in distributed acquisition systems data (IoT applications)
  • Especially suitable for server rooms, pharmaceutical and food warehouses, laboratories, museums and greenhouses
  • Logged data is stored in the internal memory and then sent digitally to the user (over Ethernet)
  • Alarms are formed by e-mails, on the webserver, using symbols on screen or via audible alarms
  • HT20IoT can be powered by the Ethernet network (PoE – Power over Ethernet), additionally ordered
  • FTP, DHCP, SMT, Modbus TCP/IP protocols
  • Digital data logger KD8 with a colored touchscreen LCD display
  • The device is designed for measurement and logging of parameters in industry, energy sector, control and monitoring systems
  • Software for data analysis in PC
  • 4-language menu, electronic signature for data protection
Temperature and humidity mini data loggers SL5x. Operating temperature from -40°C to +140°C, designed for temperature measurements or temperature and humidity measurements logging. Due to small size (Ø17x6 mm) these data loggers can easily be fit in small objects and packages. ♦ Compact size♦ Sturdy and reliable construction♦ Wide range of accessories♦ Free software♦ Data export function♦ Cold supply chain assurance while transporting and storing pharmaceuticals and biotechnological products, chemicals and food products which require special transport and stora..
  • To measure and data logging: carbon dioxide (0...5000 ppm), temperature (0...50 °C), atmospheric pressure (800...1100 hPa), humidity (0…100 % RH) in air and neutral gases
  • Free software for configuration and data visualization
  • Bluetooth communication for smartphones and tablets (Android and IOS)
  • Safety lock magnetic mounting with inviolability system holder (accessories)
  • Compatible with food industry environment
  • Up to 4 recordable parameters simultaneously
  • Optional calibration certificate
  • Triton Vape Detector  detects of vaped and burn nicotine, THC, and other substances. Does not differentiate the substances
  • Monitoring of Humidity, Particulate Matter Index and VOC Index
  • Rejects most aerosols with a similar profile to vape/smoking
  • Alert Options: SMS Text Message, Email, App, Notification, 3rd Party Integration, Audible Alarm
  • Tamper protection: Device Vandalism, Device Disconnect, Masking and Sensor Cover, Ultra-loud alarm to dissuade tampering
  • Integrations: Integrates with numerous 3rd party video management systems to give context to alerts through automatic camera recording
  • Manage devices through the Triton Sync online dashboard and app in Cloud. Real-time monitoring and customizable alerts
  • Operating environment Temperature / Humidity: 0…40 °C / 0…90 % RH (non-condensing)
  • Power Supply PoE (IEEE 802.3af Class 3 Compliance) 9W 48V
  • With display and operation via keys, three display pages for temperature humidity and other parameters to show
  • 4...20 mA analogue output, alarm relay connection, Modbus-RTU (RS-485)
  • Extreme long-term stability, quick response time
  • Sensor diagnostic with CS service software
  • Suitable to measurement in granulate dryers, compressed refrigerating gases 
  • Extreme long-term stability, quick response time
  • Sensor diagnostic with CS service software
  • 4...20 mA analogue output, Modbus-RTU (RS-485)
  • Suitable to measurement residual moisture, dew point after granulate driers in plastic industry and various gases

The DPI series electronic pressure measuring devices are engineered for building automation in HVAC/R industry. The most technologically advanced and versatile electronic differential pressure switches on the market, combining up to two relay outputs and 0–10 V output options.

  • Range: from 0....60 to 0...5 kPa
  • Accuracy: ±2% (FS 20°C)
  • Allowed overpressure: 20 kPa
  • Operating temperature: -5...+60°C

Differential manometer DPG/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.

  • Range: 0…1500 Pa
  • Switch activation range: 20…1500 Pa
  • Operating temperature: -5… +60°C

Differential manometer MM for air and non-aggressive gasses, designed for pressure measurement in narrow ranges.

  • Range: -100…1500 Pa
  • Operating temperature: -40… +60°C

Differential manometer MM/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.

  • Range: 0…1500 Pa
  • Switch activation range: 40…1500 Pa
  • Operating temperature: -20… +60°C
  • Pressure range: from -1...6 to -1...18 bar
  • Output signal: 1 Floating change-over contact (SPDT)
  • Process temperature: -40...+150 °C
  • Process connection: G1/4" f, G1/8" f, G1/2" m
  • Protection class: IP65

Differential pressure switch is designed for use in air and non-aggressive gasses. Made by HK Instruments (Finland).

Loading...