- Measurement range: -40...+150 °C
- Temperature measurement accuracy: ± 1,3 °C
- Operating temperature: -20...+50 °C
- Used with wireless manifold
- Cable of 2 m length
- 124 refrigerant gases
- Sturdy
- Hanging hook
- 3 'Y' ¼” 'MFL connectors including one with a Schrader valve
- T22CT can be used for network analysis, monitoring and measuring of non -sinusoidal and distorted networks AC current
- Variations of measuring current range (A): 0...50 / 100 / 150 / 200 / 250 / 300 / 400 / 500 / 600 / 750
- Output: 4…20 mA or 0…20 mA (Proportional change to input current)
- Frequency range of Measuring current: 50…60 Hz
- High electric isolation between primary conductor and output
- Mounting onto 35 mm DIN rail by means of optional supply of snap on mounting
- Auxiliary power supply: 24 V DC, ± 15%
- Protection class: IP20
- Operating temperature and Humidity: 0…+70 °C, 0...95% RH without condensation
- Portable, small dimension temperature meter with a probe
- The probe can be 1,5 m, 3 m or of specified length
- Temperature measurement accuracy: ±1 °C
- Temperature measurement range: -50...+150 °C
- LCD screen
- 2 year warranty
- Supply: 1x6LF-22 (9 V)
- Maximal pressure measurement range: 0...7000 Pa
- Air flow and velocity measurement
- LCD screen
- Allowed overpressure: 25 kPa
- Supply: 9 V battery
- Operating temperature: 10...+50°C
- Protection class: IP54
Antenna radar level meter ARLM-54 designed for reliable level measurement of various liquids and pasty.
- Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
- Intelligent numerical signal processing with false reflection elimination
- Measuring range up to 8 m or up to 20 m
- Current output - 4...20 mA, HART communication
- Measurement independent of temperature and pressure of the atmosphere above the surface
- Possibility to measure even in aggressive vapors
- Operating temperature: -30…+70 °C
- Protection class: IP68
- Antenna radar level meter ARLM-70 "AMANDA" designed for reliable level measurement of various liquids
- Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
- FMCW antenna radar level gauge with a range of up to 20 m
- Teaching function to suppress false reflections
- Display of measured values on matrix OLED or LCD display
- Current output - 4...20 mA, HART communication
- Manual or remote adjustment
- Measurement independent of temperature and pressure of the atmosphere above the surface
- Possibility to measure even in aggressive vapours or vacuum
- Operating temperature: -30…+70 °C
- Measures ambient air pressure
- Measurement range: 600...1100 hPa
- Operating temperature: -30...80 °C
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
- CLM-70 for continuous level measurement of liquids, bulk solids in all industrial branches
- Stainless steel design suitable for the food and pharmaceutical industries
- Output: 4...20 mA with two-way HART
- Process connection: G1”, G1 ½”, NPT 1" threads and Tri-Clamp (Ø 50.5 or 64 mm)
- Arbitrary electrode length (up to 20 m)
- Display of measured values on matrix OLED or LCD display
- Power supply: 18…36 V DC
- Protection class: IP67
- Measures carbon dioxide concentration in air
- Measurement range: 0...2000 ppm
- Operating temperature: -30...60 °C
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 15 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
- Measures carbon dioxide concentration in air
- Measurement range: 0...10000 ppm
- Operating temperature: -30...80 °C
- Cable length: 1 / 2 / 5 / 10 m
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 15 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
- Measures carbon dioxide concentration in air
- Duct mount
- Measurement range: 0...2000 ppm
- Operating temperature: -30...60 °C
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 15 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
- Measures carbon dioxide concentration in air, temperature, humidity
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: 0...2000 ppm, -30...+80 °C, 5...95 %RH
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s; CO2: 15 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
- Measures carbon dioxide concentration in air, temperature, humidity
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: 0...10000 ppm, -30...+105 °C, 5...95 %RH
- Temperature and humidity sensor cable length: 1 / 2 / 4 m
- Carbon dioxide concentration sensor cable length: 1 2 / 5 / 10 m
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s; CO2: 15 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
Temperatre, humidity and pressure meters, loggers Cxxxx, Dxxxx.
Cxxxx are designed for indication (without data logging), Dxxxx indicates and logs listed parameters.
- Compact air flow meter with switching output (1 NO)
- Robust sensor design, protection class IP67 and compact dimensions
- Switching point continuously adjustable between 0.1...15 m/s (extended measuring range available with RLSW5)
- Exemplary areas of application: monitoring of fans, heating registers, extraction, soldering and air curtain systems
- Compact air flow meter with switching output (1 NO / 1 NC) with TÜV type examination (according to DIN EN 61010-1: 2011-07)
- Robust sensor design, protection class IP67 and compact dimensions, sensitive and fast air flow detection
- Media temperature up to 60 °C
- Switching point continuously adjustable between 0.1...30 m/s
- Exemplary areas of application: Visualization and control of air flows in building automation, filter and fan monitoring as well as in industrial applications such as catalytic converters
- Compact air flow meter with analogue output (0…10 V & 4…20 mA)
- Robust sensor design, protection class IP67 and compact dimensions
- Media temperature up to 70 °C
- Switching point continuously adjustable between 0.1...30 m/s
- Exemplary areas of application: Visualization and control of air flows in building automation, filter and fan monitoring as well as in industrial applications such as catalytic converters
Compact sensor VA 525 for measuring compressed air or nitrogen inline.
- 4...20 mA and pulse or a Modbus RTU (RS 485) interface as standard
- Optional interfaces such as Modbus TCP (Ethernet), PoE, M-Bus available
- Pressure range up to 16 bar
- Temperature range up to 60°C
- For speeds up to 224 Nm/s
- Integrated display to show the measured values
- Available from 1/4" to 2''
- Settings adjustable via the keys of the display
- Main counter can be reset via the display
- Data logger for level measurement up to 100 m
- Measuring interval: from 0,5 s to 24 hours
- Data capacity: up to 500 000 values
- Interface: RS-485
- Ambient temperature: -5...50 °C
- Protection class: IP67
- Sensor material: stainless steel 1.4435 (316L)
- Supply: 3,6 V lithium battery
- Included: 110 m PE cable, RS-485 converter, software
Без НДС: 637.00 €
- Range: from 0....60 to 0...5 kPa
- Accuracy: ±2% (FS 20°C)
- Allowed overpressure: 20 kPa
- Operating temperature: -5...+60°C
Differential manometer DPG/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.
- Range: 0…1500 Pa
- Switch activation range: 20…1500 Pa
- Operating temperature: -5… +60°C
Differential manometer MM/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.
- Range: 0…1500 Pa
- Switch activation range: 40…1500 Pa
- Operating temperature: -20… +60°C
- Digital pulse counter - tachometer ECH4400
- Count inputs: 2 channels (max 50 kHz, 5…30 V pulses), can be selected as PNP or NPN input
- Counting frequency: (20, 50, 100, 500, 1000, 5000) Hz, (10, 20, 30, 40) kHz
- Control outputs: 2 relay NO / NC 250 V, 2 A
- SSR outputs: Open collector output (Max.: 30 VDC, 50 mA)
- RS485 Modbus communication interface (custom ordered)
- Power supply: 90…250 V AC; 10…30 V DC; 8…24 V AC (custom ordered)
- Auxiliary supply output: 12 VDC, max 50 mA
- Ambient temperature: 0…+50 °C
- Case protection: front panel IP65, rear panel IP20
- Temperature range: -30...70 °C
- Accuracy: ±0,5 °C (-10 °C...40 °C) / ± 1 °C
- Display: LCD
- Battery work time: 2 years
- Battery type: 1/2 AA (3,6 V)
- Dimensions: 45x100x19 mm
- Protection class: IP65
- Weight: 85 g
- Holder is ordered separately
- Measurement of 85 power network parameters, including current and voltage harmonics up to 31st in 1-phase 2-wire or 3-phase 3 or 4-wire.
- Accuracy of active energy measurement 0.5S or 0.2S
- RS-485 (Modbus RTU) interface for remote monitoring of measured parameters
- The dual-tariff function for energy billing applications
- 2 relay outputs
- Pulse output: SO output as pulse or alarm
- 2 digital inputs as energy consumption, pulse counting and contact status
- Measured values displayed in 10 configurable screens
- Possibility programming of current and voltage ratio without restrictions as in MID-certified products
- Measurement inputs dedicated for x/1A and x/5A current transformers
- Power supply: 100…550 V a.c. / d.c.
- DIN rail mounted
- Fuel sawdust moisture meter WTR-2A is designed to measure moisture of sawdust, scobs, wood shavings, slivers and other finely crumbled wood waste used as fuel
- Range: 35...85 %
- Sample volume: 120 cm2
- Measuring sample: 0,2 MPa
- Portable, small dimension grain moisture meter
- The sample is ground, increasing the measurement accuracy
- External probes can be connected
- Temperature measurement accuracy: ±0,5 °C
- Moisture measurement accuracy: ±0,5 %
- Automatic temperature compensation
- Calibrated for more than 400 grain species
- 2” LCD screen
- USB connection for software updates and data transfer
- Supply: 4xAA (1,5 V), 1xCR2032 (3 V)
- Portable, small dimension grain moisture meter
- Temperature measurement accuracy: ±0,5 °C
- Moisture measurement accuracy: ±1 % (in range up to 10 %)
- Calibrated for more than a hundred grain types (the list can be extended)
- Automatic temperature compensation
- 2” LCD screen
- USB connection for software updates
- Supply: 2xAA (1,5 V, LR6)
- Portable, small dimension grain moisture meter
- The sample is ground, increasing the measurement accuracy
- Temperature measurement accuracy: ±0,5 °C
- Moisture measurement accuracy: ±0,5 %
- Calibrated for more than 400 grain types
- Automatic temperature compensation
- 2” LCD screen
- USB connection for software updates
- Supply: 1x6LF-22 (9 V)
- Portable, small dimension grain moisture meter
- The sample is ground, increasing the measurement accuracy
- Temperature measurement accuracy: ±1 °C
- Moisture measurement accuracy: ±0,5 %
- Automatic temperature compensation
- LCD screen
- Supply: 4xAA (1,5 V), 1xCR2032 (3 V)
Automatic portable solid state particle (dust) meter EMIOTEST 3114 is designed for periodic solid state particle concentration measurement in closed channels, i.e. flue gas, and perform other functions:
- Periodic measurement of solid state particle concentration in stationary sources of emission
- Solid state particle concentration measurement in gasses
- Testing of dust removal equipment
- Gas flow rate measurement
- Calibration and periodic control of automatic systems (AMS) by measuring the emission and mass stream of dust
- Dioxins, furans, PAH, mercury concentration measurement
- Heavy meal, HCL, HF concentration measurement
- Designed to measure the moisture of hay and straw
- Moisture measurement method: resistive
- Moisture range: 8...50 %
- Universal input for measuring temperature, resistance and standard signal
- 4 alarm outputs with signaling on LED diodes
- Digital output: RS-485 modbus (can be programmed through RS-485)
- Analog signal output: 0/4...20 mA or 0...10 V
- Two-line LCD display
- Mathematical functions for converting the measured value
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -25...23...55 °C
- Measurement of parameters: voltage, current, active, reactive and apparent power, cosφ, tgφ, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
- Current and voltage harmonics analysis up to 51st (measurements available via RS-485)
- Programmable input:
- Current: 0…1 / 0…5A
- Voltage: 0…100V / 0…230V / 0…400V
- Output:
- Analog: 0/4...20 mA or 0...10 V
- Relays: 1 or 4
- Binary (OC)
- Digital output: RS-485 modbus (can be programmed through RS-485)
- Two-line LCD display
- Pulse output to measure energy consumption
- 4 alarm outputs with signaling on LED diodes, working in 7 different modes
- Conversion of any measured value into an analog signal 0/4...20 mA or 0...10V
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -25...23...55 °C
N19Z meter measures AC voltage and current. The meter is designed to work in 3-phase networks or 1-phase networks.
- Nominal input voltage: 300 or 600 V 1 phase / 100…500 V 3 phase
- Nominal input current: 1A or 5A
- True RMS measurement (up to 15th Harmonic)
- On site programmable PT/CT ratios
- User selectable 3ph3wire or 3ph4wire Network (for 3ph)
- Onsite selection of Auto scroll / Fixed Screen (for 3ph)
- 4 Digits 14mm ultra bright LED Display
- Protection: IP54 front / IP20 back
- Parameter Screen recall: In case of power failure, the instrument memorizes the last displayed screen
- Accuracy: ±0.5% of nominal value
Indoor temperature meter / transducer Txx18, designed for temperature, humidity and barometric pressure measurement.
SpotScan is a linear scanning add-on for RAYTEK, IRCON noncontact IR thermometers ENDURANCE, Marathon MM, Modline 5 and Modline 7
SpotScan is designed to broaden the capabilities of noncontact IR thermometers while scanning measured surface linearly thus measuring wider than one dot target area
The device is designed to measure ambient air pollution by detecting concentration and distribution of particles.
- Range: -250...2550 Pa
- Maximal overpressure: 30 kPa
- Accuracy: ±1,4 %
- Pressure and air flow measurements from air diffusers and valves
- Data can be uploaded on your computer for visualization and further analysis
- Over 700 programmed valve types
- Mediums: air and non-aggressive gases
- Operating temperature: -10... +50 °C
- Connection: ø 5 mm pressure hoses
- Can be used with Pitot tube
- 5 year warranty
- Included: calibration certificate, 2 x 2 m PVC hoses
The JX-30 features the Delmhorst EDGE™ App with expanded wood species, customizable settings, and the ability to share data from any location.
- Moister measurement range: 6…60% Wood (Douglas Fir)
- Large, custom display with auto backlight – easy to read under all conditions
- Species: 74 plus 123 additional available through EDGE™ App
- Wood temperature correction (°F/°C)
- Pins/electrode correction (insulated or non-insulated)
- Alarm set point: alerts to user-selected moister level
- On-screen statistics: High, Low, Average, Standard Deviation, View all readings
- Internal calibration check
- “Low Batt” warning with audio
- Auto off timer. Set to 1 min, 4 min or 10 min
- Integral contact pins max 5/16” penetration (use 2498/A-100)
- Compatible with any Delmhorst external electrode
- Color-coded LED’s: adjustable through EDGE ™app
- Power: 2x AA batteries – Alkaline Energizer (included)
- QR code on meter for easy access to support materials
- Size: meter only: 220 mm x 72mm x 39mm; in carry case - 241mm x 165mm x 64mm
- Weight with case: 510 g
- Paper moisture and temperature meter WCPT-100P, made by Tanel (Poland)
- Moisture range: 20...95 %RH; Ambient temperature: -5...+60 ºC
- Measured parameters (with respective sensors):
a) Temperature (Pt100 or thermocouple)
b) Humidity
c) Air quality
d) Air velocity
e) Airflow
f) Tachometry - Two inputs for Pt100 temperature sensors (range -200...600 °C)
- Up to 6 measurements simultaneously
- Power supply: Lithium-Ion battery (up to 57 hours)
- Calibration certificate, additional battery, transport case included
- Operating temperature: 0...50 °C
- Protection class: IP54
Infrared temperature meter KIRAY 100 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.
Infrared temperature meter KIRAY 200 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.
Noncontact infrared thermometer KIRAY 300 is designed to diagnose, inspect and check the surface temperature of measured objects. Up to 100 values can be stored in the internal memory.