  • Temperature measurement range: -40...+2250 °C (different versions)
  • Advanced signal processing
  • Wide choice of focus distances
  • Durable stainless steel IP64 enclosures designed to withstand ambient temperatures from -20 to 85 °C
  • Integrated laser sighting
  • Galvanic isolated outputs
  • Plastic lens option for food application
  • Analog input for ambient compensation and adjusting emissivity setting
  • USB for easy setup
  • Simple, two-wire or digital installation
  • Backward compatibility to old Raytek and Ircon in class sensors and accessories
  • Real-time thermal line-scanner system for continuous or discrete process measurements
  • Up to 1024 measurement points per line
  • Fast scan rates up to 150 lines per second (real-time 150 Hz thermal imaging)
  • Optical resolution up to 200:1
  • Built-in line laser for rapid alignment
  • On-board Ethernet TCP/IP communication
  • PC independent alarm output
  • PC independent 4...20 mA interfaces (3 outputs)
  • Wide choice of models and spectral responses
  • Rugged, waterproof IP65 enclosure
  • Water cooling for ambient temperature up to 180 °C
  • Measurement range: 32…43 °C
  • Measurement accuracy: ± 0,3 °C
  • Measurement distance: 0…5 cm
  • Measurement duration: 1 s
  • Measurement location: forehead
  • Automatic shut-down: 30 s
  • Measurements: 149 x 38 x 42 mm
  • Operating temperature: 10…40 °C
  • Operating humidity: ≤ 85 %
  • Certificates: ISO13485, CE, CFDA
  • Supply: 2 x AAA batteries
  • Pressure measurement range: 5...25000 μm
  • Operating temperature: -10...+50 °C
  • Overload: 610 bar
  • Two valve system
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases
  • TOR-1 transformer oil tester is designed to detect the mass fraction of dissolved water in insulating mineral oils the viscosity of which does not exceed 70 mm2 / s (cSt) at the temperature of 50 °C
  • Operating range of relative value aw (active water): 0…1
  • Operating range of dissolved water content measurement: 0….500 ppm
  • Precision at 20 °C ± 0.02 aw (0…0.9 aw) ± 0.03 aw (0.9…1 aw)
  • Operating medium temperature: 0…55 °С
  • Measured temperature of oil displayed on screen
  • Measurement results can be printed out using an integrated printer
  • LCD-panels displays the moisture and temperature of tested oil
  • Power supply: 220 V a.c
  • Easy use for oil testing in the field near the transformer
  • Voltmeters for AC voltage measurement EP27, EP29 with a change-over switch
  • Panel electromagnetic devices, designed for effective voltage measurement
  • Change-over switch, when activated, enable the measurement of linear and phase voltage (6 measurement points)
  • Tropical version is available (TIII)
  • Voltmeters for usage with voltage transformers (X/100 V and X/110 V) are also available
  • SF6 gas monitor for high and medium voltage switchgear
  • Measurement range: 0...60 kg SF6/m3
  • Output signal: current pulses onto supply current, current loop
  • Media temperature: -40...+70 °C
  • Protection class: IP65
  • Shock proof, suitable for outdoor usage, compact
  • SF6 gas monitor for high voltage switchgear
  • Four versions: 1 / 2 / 3 / 4 stages (8716 / 8726/ 8736 / 8746)
  • Measurement range: 0...1.1 MPa
  • Output signal: floating change-over contact (SPDT)
  • Switch point: factory calibrated
  • Media temperature: -40...+80 °C
  • Protection class: IP67
  • Independent, galvanically separated circuits
  • Pressure measurement range: -1...60 bar
  • Pressure measurement accuracy: ± 0,5 % of full scale
  • Overload: 65 bar
  • Operating temperature: -20...+50 °C
  • Used with wireless manifold
  • 124 refrigerant gases
  • Sensor: Pt100 (3-wire) / TC: K (with display / without display)
  • Output: HART / sensor output
  • Measurement range: -50...+400 °C
  • Configuration: via HART
  • Operating temperature: -20...+80 °C / -30...+100 °C
  • Various connection options
  • Supply: 12...40 VDC (HART), CR2032 (for screen)
  • Protection class: IP65

Differential manometer MM for air and non-aggressive gasses, designed for pressure measurement in narrow ranges.

  • Range: -100…1500 Pa
  • Operating temperature: -40… +60°C

Digital meters – bargraphs NA3, NA5, NA6,measurement of DC voltage, current, resistance and temperature measurement (with thermal sensors J, K, N, E, R, S, T, Pt100, Pt500, Pt1000).

  • Hammer wood moisture meter HIT-1 (needle), designed for moisture measurement from 6 to 50 %
  • Moisture measurement method: resistive
  • Range: 6...50 %
  • Range: 6...60 %
  • Step value: 0,1 %
  • Temperature compensation (-10...+60 °C)
  • Many wood types (12 common and 270 exotic)
  • Replaceable needles made of high quality steel
  • Display: LCD
  • Chromium plated steel body
  • Supply: 12 V battery (approx. 5000 measurements)
  • Wood moisture meter MICRO+, designed for moisture measurement from 6 to 60 %
  • Automatic turn-off
  • Battery low warning
  • Water-resistant

The oxygen concentration meter MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 °C.

  • Panel electromagnetic devices are designed to measure the angle between phase voltage and current in one-phase and three-phase circuits
  • Measured value is represented in cosine (cos φ)

Power meters PA39. Panel power meters are designed to measure active and reactive power. Transducer signal is measured using magnetoelectricity. Can be used for 1 or 3-phase measurement. Special version available for two-way energy flow measurement. Tropical version is also available (TIII).

  • Voltage range: 100 √3...690 V
  • Current range: 1A (X/1A) or 5A (X/5A)
  • Accuracy class: 1,5
  • Consumed power: = <3,25 VA
  • Protection class: Frnt panel IP52, terminal IP00
  • Devices comform with EN61000-6-2, EN-61000-6-4 standards
  • Temperature range: -10...23...+55 °C
  • Power network parameter meter N14 is designed for measuring of three-phase network parameters and accounting of internal energy consumption. Can be used in 3- or 4-wire systems
  • Can be used in energetic monitoring systems (RS-485 port)
  • Active and reactive power measurement, active and reactive power counters, average power measurement
  • Phase, current and voltage effective value measurement
  • Network frequency measurement
  • Average active power (over set time) measurement
  • Changeable current and voltage transformer transfer coefficient values
  • Operating temperature: -30...+50 °C
  • Programmable switch output and RS-485 (MODBUS) port
  • Pulse output for remote energy accounting
  • Accuracy class: current, voltage 0,5/1,0; frequency 1,0; power 2,0; energy 1,0/2,0; tg φ 1,5
  • Designed for direct or indirect measurement of 1-phase network parameters
  • Measured values: U, I, f, P, Q, S, PF, tg fi, fi, Ep, Eq
  • Direct measurements up to 63 A
  • Universal input: 1/5 A 100/400 VAC or 32/63 A, 100/400 VAC
  • Outputs: RS-485 (MODBUS interface), 1x relay + 1x analog or 2x relay
  • OLED display
  • Programmable current and voltage transformer ratios
  • Programmable via buttons or free eCon software (through USB)
  • Size: 53 x 110 x 60 mm
  • Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
  • THD factor
  • Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
  • Digital output: RS-485 MODBUS (option)
  • Protection class for front side: IP65
  • Supply: 85...253 VDC/VAC
  • Backlit LCD display
  • Dimensions: 96 x 96 x 77 mm
  • Power network meter ND20 is designed to measure 3-phase network parameters and to account internal energy consumption
  • Usable in 3- and 4-wire systems
  • Can be used in energetic monitoring systems (RS-485 port)
  • Front panel protection class IP65
  • Harmonic, THD, watthour measurement
  • 3,5” LCD indicator
  • Analog output of 0/4...20 mA (additionally ordered)
  • Measurement of power network parameters in 1-phase and 3-phase (3 or 4-wire) systems
  • Current inputs 0,1 A and 0,25 A (for dedicated transformers)
  • Quick and convenient ways to connect current transformers via RJ12 connector or screw terminals
  • Designed for usage with following transformers: LJ12, LJ25, LJ35, LJ45, LJ306, LJ307, LJ308
  • RS-485 (MODBUS RTU) interface
  • THD factor measurement
  • Backlighted LCD 3,5”
  • Protection grade from the frontal side: IP65
  • Power network parameter measurement in 1- and 3-phase network
  • THD factor calculation
  • High accuracy class
  • Backlit LCD 3,5” display
  • RS-485 Modbus slave interface
  • Frontal protection class: IP65
  • Measures 54 power network parameters (up to 63-rd harmonic, in 1- and 3-phase network)
  • Color LCD TFT 3,5” display
  • Display pages are fully configurable by user (10 pages. 8 parameters in each)
  • 2 configurable alarm outputs
  • Digital RS-485 Modbus output
  • Optional: 0/4...20 mA output and 2xPt100 inputs
  • Option: logging of 32 parameters into internal 8 GB memory
  • Modbus TCP/IP, HTTP, FTP server, WWW server, DHCP client
  • SF6 gas density monitor for high voltage switchgear
  • Three versions: 1 / 2 / 3 stages (8781 / 8782 / 8783)
  • Measurement range: 0...1,1 MPa (mechanical), 0...0,85 MPa (electronic)
  • Output signal: floating change-over contact (SPDT) / 6.5...20 mA current loop
  • Switch point: factory calibrated
  • Media temperature: -40...+80 °C
  • Ambient temperature: -40...+80 °C
  • Protection class: IP65
  • Measurement range of external sensor: -200...+600 °C
  • Operating temperature: -30...+80 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Communication protocol: WWW, ModbusTCP, SNMPv1, SOAP, XML
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measurement range: -40...+150 °C, -1...60 bar
  • Temperature measurement accuracy: ± 1,3 °C
  • Pressure measurement accuracy: ±0,5 % of full scale
  • Operating temperature: -20...+50 °C
  • Overload: 65 bar
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases
  • Measurement range: -40...+150 °C, -1...60 bar
  • Temperature measurement accuracy: ± 1,3 °C
  • Pressure measurement accuracy: ±0,5 % of full scale
  • Operating temperature: -20...+50 °C
  • Overload: 65 bar
  • Two valve system
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases
  • Meter N27D is designed to measure parameters of the single-phase power network
  • Direct measurements up to 63 A
  • The device measures voltage, current, frequency and active power
  • Measurements are represented in 4-digit display
  • Button enables the scrolling through available measurements
  • Mounted on standard 35 mm rail (LST-EN 62208)

♦ Positive, negative and differential pressure measurement
♦ Air speed measurement
♦ Automatic zero find function
♦ Measured value hold
♦ Minimal and maximal value detection
♦ Measurement unit option

  • Portable analyzer NP40 is designed for power network quality parameter analysis
  • Analyses voltage and current harmonics up to 51-st, THD
  • Real-time waveform display (4 voltage / 4 current)
  • Measurement of TRMS currents up to 3000 A (with standard sensor)
  • Half cycle RMS measurement (voltage and current)
  • Measurement in 1-phase and 3-phase systems (3- and 4-wire)
  • Voltage, current, harmonics, power, energy and other parameter measurement
  • Graphical representation of data in a waveform and vector diagram
  • Record of events: dips, swells, overvoltages
  • Built-in 8 GB memory card
  • Ethernet interface for remote monitoring
  • USB interface for data transfer
  • Color 5,6” TFT display, 320 x 240 px
  • Measurement distance: 0,5…2 m
  • Accuracy: ± 0,5 °C
  • Measurement speed: 0,7…2 m
  • Software: DERMALOG Fever Detection (PC required)
  • Interface: USB 3.0
  • SDK: .Net / C / C++ / (Java coming soon)
  • Measurement speed: 0,6 s (up to 700 people per hour)
  • Integrated sensors: 5
  • IR thermal array, range: 0...100 °C (± 0,3 °C)
  • Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
  • Relative humidity sensor, range: 0...100 % (± 3 %)
  • Vibration sensor (for sabotage detection), range: 0,25...5 G
  • Distance sensor, resolution: 1 mm
  • Dew point calculation
  • Relay inputs: 2
  • Relay outputs: 2
  • LED indication, buzzer (85 dB)
  • Communication: Ethernet (10/100)
  • Connector (RJ45) for connection of other Kentix devices
  • Webserver
  • Software: remote connection with AlarmManager-PRO
  • E-mail, SNMP alarms, Rest API
  • SD card slot (to save pictures, card up to 128 GB)
  • PoE
  • Optional: RFID reader
  • Optional: wall bracket, cable
  • Wide temperature range: -10...+1200 °C
  • 320 x 240 and 640 x 480 infrared resolution
  • 9 or 60 Hz models available
  • Sighting: IR-Fusion technology (thermal and visible sighting) for easy alignment and added detail on blended images
  • Remote motorized focus
  • Multiple field interchangeable lens options available
  • GigE Vision interface
  • LAN/Ethernet with PoE for communication with the thermal imager provides access to Ethernet, Web server and ThermoView Software
  • I/O alarming capabilities
  • ThermoView software for industrial automation applications
  • Ambient temperatures to 200 °C with high temperature enclosure
  • Air purge and accessories available
  • Rugged housing, IP67 rated
  • Multimeter with backlit LCD screen (two shown values)
  • Four versions: NP10-2, NP10-3, NP10-5, NP10-6 TRMS (see datasheet below)
  • Capacity measurement from 1 pF to 40 mF
  • AC and DC voltage measurement from 100 μV to 1000 V
  • AC and DC current measurement from 10 μA to 10 A
  • Resistance measurement from 100 mΩ to 60 MΩ
  • Frequency measurement from 10 Hz to 10 MHz
  • Diode measurement and continuity testing
  • Hold function
  • Relative measurement
  • Duty cycle (%) measurement
  • Temperature measurement (K type thermocouple) from 0 to 1300 °C
  • Peak value measurement
  • Digital multimeter with data logging view function (up to 32000 readings) 
  • Four versions: NP15-2, NP15-3, NP15-5, NP15-6 TRMS (see datasheet below)
  • TRMS measurement
  • Low input impedance
  • Capacity measurement from 1 pF to 40 mF
  • AC and DC voltage measurement up to 1000 V
  • AC and DC current measurement up to 10 A
  • Resistance measurement
  • Frequency measurement
  • Diode measurement and continuity testing
  • Filtering
  • Square wave signal generator
  • Hold function, backlight, maximal and minimal value presentation
  • External supply
  • Duty cycle (%) measurement
  • Temperature measurement (K, J type thermocouples, Pt100 and Pt1000)
  • Automatic / manual range selection
  • USB connectivity (optional)
  • Digital multimeter for insulation resistance measurement
  • Multimeter with backlit LCD screen
  • AC and DC voltage measurement up to 1000 V
  • AC and DC current measurement up to 300 mA
  • Resistance measurement up to 30 mΩ
  • Insulation resistance measurement up to 3 GΩ
  • Capacitance measurement up to 30 μF
  • Frequency measurement up to 100 kHz
  • Fill factor measurement (%)
  • Hold function
  • Temperature measurement (Pt100 and Pt1000)
  • Diode check
  • Analog scale on screen

Digital thermometer SDT8 for temperature measurement from -50 to +150 °C.

Frequency meters CA32, CA36, CA37, CA39, CA39L are designed for frequency measurement in electrical grid. Transducer signal is measured using magnetoelectric effect. Tropical version available.

  • Frequency range: 45...55, 45...65, 48...52, 55...65, 360...440, 380...420 Hz
  • Voltage range: 60,100, 110, 230, 240, 400, 415, 440, 500 ± 20%
  • Accuracy class: 0,5
  • Consumed power: =< 7 VA
  • Protection class: IP52 or IP65
  • Standards conformed: EN61000-6-2, EN-61000-6-4, EN-61010-1
  • Temperature range: 5...23...40 °C
  • Temperature range: -50...250 °C or -50...500 °C
  • Accuracy: ±0,03 °C
  • Resolution: 0,01 °C (switchable to 0,1 °C)
  • Display: LCD, 6 digits, backlight
  • MIN, MAX, hold functions
  • Sensor: Pt100
  • Protection class: IP65
  • Suitcase is ordered separately
  • Thermometer DT20 for temperature measurement in smokehouses, butcheries, etc.
  • Measuring range -50...20 °C, accuracy 0,1 °C
  • Sharp-tipped probe ST-03 (4x120 mm) made of stainless, acid-resistant steel (1H18N9T)
  • Cable length 3 m
  • Operating temperature 0...40 °C
  • Supply 230 V
  • Size 130x94x81 mm
  • Ergonomic ABS casing with indicator, IP65

Digital thermometer DT-34 is designed for fluid, gas and solid body temperature measurement in range of -50°C to 270°C. Casing is made out of mechanically resistant plastic (ABS) and contains special collars for dust, dirt and water protection.

The measurements are done with a Pt1000 sensor. Special sensor construction and small size ensure little thermal inertia and fast measurement. The results are shown in a 4-digit LCD display, of which the fourth digit shows the decimal part. Negative temperatures are shown with a minus sign. The device can be used in laboratories and manufacturing for technological measurements in various conditions.

Thermometer DT-34 can be shipped with a fitting temperature sensor made according to Your requirements.

Digital thermometer ST-90 for temperature measurement from -200 to 1200 °C.

ST-90 is designed for usage with various construction K-type thermocouple sensors. The sensor is connected via MiniTherm port on the top of ST-90. The device is supplied by 9V 6F22 battery (work time up to 500 h). Indication on LCD screen (3 1/2). Special collars protect the electronics from moisture, grease and dust.

Thermometer ST-90 can be shipped with a fitting temperature sensor made according to Your requirements.

  • Temperature range: -30...+70 °C
  • Humidity range: 0...100% RH
  • Resolution in range: 0.1 °C
  • Temperature accuracy: In range -20...+40 °C: ±0,5 °C; outside of range: ±1,0 °C
  • Humidity accuracy: ± 2 %RH
  • Supply: 3.6 V (Lithium battery)
  • Battery lifetime: up to 2 years
  • Protection class: IP65
  • Size: 45 x 100 x 19 mm

Digital thermometer DT-1 is designed to be used for temperature measurements in liquids, gasses and solids in range of -50...+200 °C. The casing is made out of mechanically resistant plastic (ABS) and has special collars, protecting the device from dust, dirt and water. The measurements are conducted using a Pt1000 sensor. Special sensor construction and small size guarantee little delay and fast measurement. The results are shown in 4-digit LCD (last digit represents the decimal part). The device can be used in laboratories and industry in any conditions.