- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
- Boasts for great reliability and small size
- Weight: 111 g; Buoy volume: 225 cm3; Maximum pressure: < 2 bar / < 5 bar
- Exd fire-resistant RTD temperature sensors are designed for temperature sensing in explosive atmospheres
- Ranges: -200...+150°C; -200...+550°C; -200...+600°C
- Outputs: RTD, 4..20 mA
- Exd fire-resistant thermocouple temperature sensors are designed for temperature sensing in explosive atmospheres.
- Ranges: -40...+800°C; -40...+1200°C; -40...+700°C
- Outputs: TC, 4...20 mA
- Exi RTD sensors for explosive atmospheres with cable
- Range: -50 .. +400°C
- Cable insulation: PVC, silicone, teflon, glass fiber
- Exi thermocouple sensors for explosive atmospheres
- Range: -40...+1200°C
- Exi thermocouple sensors for explosive atmospheres with cable
- Range: -40...+400°C
- Exi thermocouple sensors for explosive atmospheres with connection head
- Outputs: TC, 4..20 mA
Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.
- Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
- Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
- CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
- Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
- Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
- Air quality (VOC) measuring range: 0…100 %
- Data output: galvanically separated RS-485 Modbus RTU interface
- Variants: with / without LCD display
- One sensor covers about 30 m² of room area
- Power supply: 24 V ac/dc (200 mA)
- Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
You can use it for limit sensing of liquid levels in non-conductive tanks (through the non-conductive wall of a vessel or pipeline).
The sensor is equipped with a high-frequency technology, enabling reliable function even in case of adhering conductive media.
Miniature performance in a flexible housing, optional installation on slightly curving surfaces.
Attached using self-adhesive a layer or special fastening bands.
Configuration and setup using "programming" cable or magnetic pen.
LED status indication.
Vertical, stainless steel, float level sensor with float protection against mechanical impact, designed for level control.
- Material of float: stainless steel AISI 316 SS
- Max. temperature: -30...+105 °C
- Switch rating: 50 VA
- Switching voltage: 230 AC / DC
- Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Float level switches AUREGIS LJ-V with an extension for level control
- Operating temperature: -30...+130°C
- Protection class: IP65
Thermal mass flow sensor for compressed air and gases VA 500
- 4...20 mA, pulse and a Modbus RTU (RS 485) interface as standard
- Optional: Interfaces such as Modbus TCP (Ethernet), PoE, M-Bus
- Optional: Bi-directional measurement
- Pressure tight up to 50 bar
- Temperature range up to 110 °C
- Protection class IP65
- Suitable for gas velocities up to 224 Nm/s
- Integrated display for showing the measured values
- Can be used from 1/2" up to 40", larger diameters on request
- Easy installation under pressure
- Settings can be changed via the display
- Main counter reading can be reset via the display
- Calorimetric measuring principle
- Units freely selectable via keys at the display
- Display shows 2 values at the same time, twistable by 180 ° degree
- Integrated Modbus interface enables connection control systems, SCADA
- M-Bus (optional)
- Analog output 4...20 mA
- Pulse output (galvanic isolation)
- High measuring accuracy (ideal for leakage measurement)
- Flow sensor suitable for evaluation unit NLSW®45-6 and NLSW®45-6.1
- Thread: PG7, optional accessories available
- Material: stainless steel V4A
- Media temperature: optional up to 400°C
- Protection class sensor: IP50
- Insertion depth: 50 mm, 130 mm, 165 mm, 300 mm
- Compressive strength: 10 bar
The frame light barriers of FLB Series are used for the measurement of smallest unguided parts.
- Gas measuring, monitoring and warning controller (Multi-Sensor-Controller MSC) for reliable detection of combustible, toxic and refrigerant gases
- Flexible control: 3 relays (SPDT, potential-free, 250 V)
- Intelligent Communication: RS-485 interface with DGC and Modbus protocol
- Precise signal transmission: 4–20 mA input and output for seamless system integration, up to 3 sensors including remote
- Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
- Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
- Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
- Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
SKU: 5905309602212
- Efento Gateway automatically transfers gathered data from Efento BLE (Bluetooth Low Energy) sensors to Efento Cloud or any other IoT platform over 4G LTE
- Gateway stores 500,000 measurements in its buffer memory in case the connection to Efento Cloud is lost, it will send the measurements right after connection is restored
- If Gateway used without Efento cloud it can store sensors data in its memory
- In local mode you can check the current and historical measurements (table/chart) and export the data in a form of CSV report
- Gateway communicates with sensors wirelessly over BLE. The maximum distance between Gateway and sensor is 100 m in the open space and 20 – 30 m in the buildings
- One gateway supports up to 128 Efento sensors
- Gateway can be integrated with any cloud platform or software that supports HTTP protocol (REST API)
- Setup takes under 5 minutes and can be completed using a smartphone with a free mobile app
- SIM card slot for LTE Cat 1 connection
- Power supply: 5 V, 1 A (USB-C)
- Backup battery: LI-Po, 1900 mAh (up to 12 hours backup power)
- Operating temperature: 0…+40 °C
SKU: 5906660327066
- Efento Gateway automatically transfers gathered data from Efento BLE (Bluetooth Low Energy) sensors to Efento Cloud or any other IoT platform
- Gateway stores 500,000 measurements in its buffer memory in case the connection to Efento Cloud is lost, it will send the measurements right after connection is restored
- If Gateway used without Efento cloud it can store sensors data in its memory
- In local mode you can check the current and historical measurements (table/chart) and export the data in a form of CSV report
- Gateway communicates with sensors wirelessly over BLE. The maximum distance between Gateway and sensor is 100 m in the open space and 20 – 30 m in the buildings
- One gateway supports up to 128 Efento sensors
- Gateway can be integrated with any cloud platform or software that supports HTTP protocol (REST API)
- Configuration of Efento Gateway using any internet browser over LAN
- Ethernet connection for data transfer
- Power supply: 5 V, 1 A (mini USB)
- Operating temperature: 0…+40 °C
Inline sensors of the GLAST series primarily are used for the inspection of highly reflecting surfaces (e.g. stainless steel panels, aluminum sheets, painted surfaces, plastic films) and transparent objects (films, glass plates, plexiglass plates).
GLOSS sensors prioritize narrower detection range, thus making it faster than similar devices.
Gloss sensors RLS-GD-15, R-LAS-GD-15-HP. The sensors are designed for plastic plate and ceramic parts gloss degree measurement. Two measurements are done at the same time – direct reflection direction and diffusion reflection direction.
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø9,8 mm
- Length: 1...35 m
- Tensile strength: ≤ 2,5 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø17 mm
- Length: 1...100 m
- Tensile strength: ≤ 8 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
- GA-1 is designed for grease detection in separators, basins and tanks
- Easy to install, does not need calibration
- Switch output
- Remote monitoring capability
- Wall-mounted
- Supply: 230 VAC, 50/60 Hz
- GA-2 is designed for grease detection in separators, basins and tanks
- Two sensors – one is for grease detection, other – for blockage control
- Easy to install, does not need calibration
- 2 switch outputs
- Remote monitoring capability
- Wall-mounted
- Supply: 230 VAC, 50/60 Hz
- Used with grain temperature sensor cables GWSL 1100, GWSL 2100 and spear sensors GWTL-R
- Cable length up to 200 m (including the temperature cables)
- Up to 32 values of temperatures are shown in cycle
- Weight: 240 g (with batteries)
- Case material: ABS
- Supply: 2 x AA (battery life circa 1 year)
- Operating temperature: -20...+40 °C
High frequency limit level sensors with elimination of deposits and foam on the electrode for vertical mounting
- High frequency limit level sensors with elimination of deposits and foam on the electrode for vertical mounting,
- Resistant to adhesion of viscous and sticky media (ketchup, yoghurt, spreads, syrups, creams, pastes, cleaning agents, alkalis, etc.)
- Unique material type resolution function "Medium window" (the sensor is sensitive only to the set medium and does not react to substances with lower and higher permittivity)
- Can replace vibration level sensors
- Universal design for all types of liquids (electrically conductive or non-conductive)
- For vertical mounting
- Adjustment with a magnetic pen before installation
- High level detection
- Oil on water surface detection
- Designed for usage in separators, basins and tanks
- Easy to install, does not need calibration
- Reliable long-term se in harshest conditions
- Acoustic and visual alarms
- 2 switch outputs
- ATEX certified
- Wall-mounted
- Supply: 230 VAC, 50/60 Hz
High-frequency contrast sensors for UV, VIS and IR range.
Level sensor with elimination of rests or foam on the electrode:
- Designed for reliable limit level sensing of wide-range of fluids (electrically conductive or non-conductive), mashed and paste-like materials
- Resistant to adhesion of viscous and sticky media (ketchup, yoghurt, spreads, syrups, creams, pastes, cleaning agents, alkalis, etc.)
- Replacement of vibration level sensors
- Unique function for media recognition “Medium window” (sensor is sensitive only to set medium and does not react to substances with a lower or higher permittivity)
- Direct mounting into tanks, vessels, sumps, pipes or funnels and containers
- Settings by the magic pen (included)
SM400-4-TH humidity and temperature sensor supports MODBUS RTU protocol over the RS-485 interface. Suitable for environmental quality monitoring offices, server room, data center and indoor air
- Changeable communication parameters
- Non-volatile memory for all settings
- Operating temperature range: -20…60°C
- Accuracy (min): ± 0.4 °C (in -10…+ 60 °C range)
- Accuracy (max): ± 0.6 °C (in -20…+ 60 °C range)
- Resolution: 0.1 °C
- Operating relative humidity range: 10…90% (non-condensing)
- Accuracy (min): ± 3.0 % RH (in 20…80 % RH range)
- Accuracy (max): ± 5.0 % RH (in 10…90 % RH range)
- Resolution: 0.1 % RH
- Ingress protection: IP20
- Operating voltage range: 4.5…26 VDC
- For continuous level measurement in non-pressure tanks, vessels and pipes
- Output: 4...20 mA / 0...10 V
- Measuring range up to 100 m (H2O)
- High long-term stability
- Accuracy: 0,5 % within the total range
- LED indication
- Operating temperature: -20...+70 °C
- Supply: 12...34 VDC
- Protection class: IP67 / IP68
Hydrostatic pressure transmitter HLM-25S is designed for level measurement in non-aggressive fluids in non-pressure tanks, boring holes, wells. Measuring range is up to 100 m in water. Current or voltage output.
idOil sensors are an integral part of the idOil oil separator alarm system and they are to be used with the idOil control units. All idOil sensors are digital and polarity free. Standard cable length is 5 m.
- idOil-LIQ high liquid level sensor
Indicates when the liquid level in the oil separator rises excessively e.g. in an outlet blockage situation. - idOil-OIL oil sensor
Detects oil and indicates when the separator’s oil storage is full. - idOil-SLU sludge sensor
Monitors the sludge layer in the oil separator and indicates when the sludge layer has reached its maximum level.
Interior protection from flooding sensor CZP-103R, designed for protection of various rooms (workshops, servers, communication modules, etc.) against flooding. The sensor activates when there is water between its electrodes. Can be used in drainages and rainfall wells for protection against basement flooding. LED indication.
- Flood protection
- Alarm and control
- Supply 12...24 VDC
- Isolated ~5 V electrode supply
- Low energy consumption
- Size 19 mm x 66 mm
Analog laser light barriers and their electronic control units. Round or rectangular cross-sections are used for measuring, positioning or detection of objects starting from 0,01 mm (i.e. threads) from great distance (up to 100 m, depending on model).
These sensors should be used where high positioning accuracy is required.
C-LAS compact laser light barriers are ideally suited for positioning tasks.