- Temperature sensor AUREGIS TJ-4 is inextricably connected to the cable. It is designed for temperature measurement from -50°C to 400°C
- Various sizes are available depending on customer requirements and drawings
- Sensor type: PT100, PT1000, K, J, Ni120, Ni1000 and others
- Sensor type: RTD (Pt100, Pt1000), TC (K, J)
- Output: RTD (Pt100, Pt1000), TC (K, J), 4...20 mA, 4...20 mA +HART, 0...10 V, RS-485, IO-LINK
- Measuring range: -30 °C ... 250 °C, 550 °C
- Accuracy: Class A or B /cl.2
- Sensor tube:
- Material: Stainless steel AISI304 (1.4301)
- Diameter: Ø6/8/10mm
- Length: 100, 200, 500, 700, 1000mm or on request
- Connection head type: B
- Protection class: IP65
- Electrical connection: 2-wire, 3-wire or on request
- Process connection: G¼”; M20x1,5; G½” or on request
- Various sizes are available depending on customer requirements and drawings
- Temperature sensor AUREGIS TJ-1 is inextricably connected to the cable
- It is designed for temperature measurement from -50°C to 400°C
- Various sizes are available depending on customer requirements and drawings
- Sensor type: PT100, PT1000, K, J, PTC, NTC, Ni120, Ni1000
- The temperature sensor TJ-M is designed for measuring the temperature in the capacity ranging from -30°C to 550°C
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, K, J
- Connection head type: M
- Protection class: IP65
- Universal air and environment quality sensor E2-CO2-series measures CO2 (carbon dioxide) level, temperature, humidity, pressure, sound level, ambient light (LUX). Transmits instant values, average hourly values, and average 24-hour values
- Communication: wM-BUS EN13757-3/4:2013, complies OMS 4.0.2
- Modes: C1-A/B, T1 or S1 (selectable on order)
- Measurement ranges
- Temperature: -40…85 °C
- Humidity: 0…100 % RH (non-condensing)
- CO2: 0…5000 ppm (0…55 °C)
- LUX: 0,01…83000 LUX at same frequency as the human eye
- Absolute pressure: 20…100 kPa
- Sound level: 20…90 dBa at 850 Hz
- Measurement accuracy
- Temperature: ± 0,2 at +5…+60 °C; ± 0,5 at -20…+85 °C
- Humidity: ± 2 % RH at 20…80 % RH; ± 3 % RH at 10…90 % RH; ± 3,5 % RH at 0…100 % RH
- CO2: ± (50 ppm + 3%)
- LUX: 4 %
- Pressure: 0,4 kPa
- CO2 sensor calibrates every 20 days
- Warnings about low battery, CO2 sensor malfunction, calibration not performed yet
- Transmission interval: every 90 seconds
- Measured values sample interval: every 6 minutes
- LED and sound indication about CO2 exceeded limit
- Device has 2 antennas for maximum range in both vertical and horizontal directions
- Power supply: 2 x ER18505 3.6 V Li-SOCI2 battery pack (8200 mAh)
- Up to 14 years battery lifetime, standard configuration and operating temperature
- 1-Wire protocol ambient light sensor
- Light measurement range: 0...83000 lux
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
- 1-Wire protocol ambient pressure sensor TSP200
- Pressure measurement range: 300...1100 hPa
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
TSM400-1-CP is a multi-parameters sensor that supports the 1-Wire protocol. The sensor measures the concentration of carbon dioxide and atmospheric pressure.
- CO2 measurements range: 400…5000 ppm
- Accuracy: ± (40 ppm + 5 %)
- Resolution: 1 ppm
- Calibration: manual
- Pressure measurements range: 10…1200 hPa
- Accuracy (min): ±1.5 (25°C, 750 hPa)
- Accuracy (max): ±2.5 (-20 °C to + 85 °C, 300…1100 hPa)
- Resolution: 1 hPa
- Operating temperature range: -20…+60°C
- Operating relative humidity range: 5…95% (non-condensing)
- Ingress protection: IP20
- Operating voltage range: 4,5…26 VDC
TSM400-1-TH is a digital temperature and humidity sensor with a 1-Wire interface. Suitable for monitoring air quality of server rooms, data centers, offices and stores.
- Temperature measurement range: -20…+60°C
- Accuracy (min): ± 0,4 °C (in -10…+60°C range)
- Accuracy (max): ± 0,6 °C (in -20…+60°C range)
- Resolution: 0,1 °C
- Relative humidity measurement range: 10 to 90% (non-condensing)
- Accuracy (min): ± 3.0 % RH (in 20…80 % RH range)
- Accuracy (max): ± 5.0 % RH (in 10…90 % RH range)
- Resolution: 0,1 %RH
- Excellent long-term stability
- The unique 64-Bit serial number for multi-sensors support
- Ingress protection: IP20
- Operating voltage range: 4,5…26 VDC
SPECTRO-2 has 2 contrast sensors, allowing it to calculate other parameters.
- Air flow monitor with automatic reset function (alternatively available with error memory)
- Switching point continuously adjustable, switching output 2 NO/ 2 NC
- Robust sensor design, high sensor protection class IP67, sensitive and fast air flow detection
- Examples of areas of application: Monitoring of heating registers, humidifiers, air curtain systems, dampers, fans, DDC
- Operating on the Pitot tube principle
- Insensitive to airflow direction
- Accuracy: 2 %
- Pairs well with HK Instruments DPT-FLOW transducers
- Connection: 1/4” OD tubing
- Operating temperature: 5...95 °C
- Round or rectangular duct
- Various duct size options (up to 1200 mm)
- Analog gas detector MC for connection to DGC, MSC, WSB or any compatible gas detector
- Reliable self-monitoring: Integrated watchdog
- Precise signal: 4–20 mA (2–10 V) output for easy system integration
Moisture measuring of sand, minerals, clay, grain, foodstuffs, sawdust, ores, sewage sludge. During operation, the sensor requires nothing but a power supply and a display or a controller that can receive the measurement signal. The BMMS sensor is designed for applications in which no multi-part systems are to be used but still the highest precision is required. Due to the in-process calibration, all potential interference from the sensor installation is directly compensated for.
- Capacitive moisture measurement
- Temperature range of measuring material: 4...50 °C
- Direct measured values transfer from the sensor
- Calibration is made directly at sensor, beyond the process
- Capacitive moisture measurement
- Up to 16 sensors per signal processing unit
- Temperature range of measuring material: 4...80 °C
- Measured value transfer: Profibus DP or analogue standard signal (e.g. 4...20 mA) optional
- Continuous measurement or batch operation
- For continuous level measurement of diesel in trucks, building machines, locomotives, etc.
- Output: 4...20 mA / 0...10 V / CAN
- Direct mounting into a tank through the 5-hole flange or G1” thread
- Arbitrary electrode length (up to 1 m)
- Setting by means of magnetic pen
- Ambient temperature: 9...30 VDC / 12...30 VDC / 9...30 VDC
- Protection class: IP68
- CLM-70 for continuous level measurement of liquids, bulk solids in all industrial branches
- Stainless steel design suitable for the food and pharmaceutical industries
- Output: 4...20 mA with two-way HART
- Process connection: G1”, G1 ½”, NPT 1" threads and Tri-Clamp (Ø 50.5 or 64 mm)
- Arbitrary electrode length (up to 20 m)
- Display of measured values on matrix OLED or LCD display
- Power supply: 18…36 V DC
- Protection class: IP67
- For continuous level measurement of liquid and bulk-solid materials
- Output: 4...20 mA / 0...10 V
- Universal usage, direct mounting into tanks, vessels, sumps or silos and hoppers
- Setting using a magnetic pen
- Possibility of linear measurement even in non-conductive or variously shaped vessels
- LED indication
- Versions with coated electrodes for aggressive or electrically conductive media
- Versions for explosive areas
- Ambient temperature: -40...85 °C
- Supply: 9...34 VDC / 12...34 VDC
- Protection class: IP67 / IP68
CLM-36 are designed for continuous level measurement of liquids and bulk-solid materials. Mounted directly in containers, tanks, etc. Indicator LDU-401 can be mounted on head. Can be used in high temperature and explosive atmospheres. Current (4...20 mA) or voltage (0...10 V) output.
- Detection of various types electrical conductive or non-conductive liquids (water, water solution, cooling liquids, oil, ets.)
- Direct mounting into various containers, vessels, tanks, ets.
- Output: S, PNP, NAMUR (for explosive areas)
- Sensitivity setting by means of magnetic pen
- High temperature performance, pressure resistance up to 7 MPa
- Process coupling: thread M18, M20, G3/8“ or 1/2–14 NPT
- Versions for usage in explosive areas
- Supply: 6…30 VDC
- Protection class: IP68
- Universal use for limit level sensing of liquids and bulk solids
- Direct mounting into tanks, vessels, sumps and tubes or silos and hoppers
- Output: NPN, PNP, NAMUR (for explosive areas)
- Sensitivity and hysteresis fluently adjustable
- Process coupling: thread M27x2; M30x1.5; G3/4“ or Triclamp
- Indication by LED
- Versions for explosive and flammable areas
- Supply: 7…36 VDC
- Protection class: IP67
- Universal use for limit level sensing of liquids and bulk solids.
- Direct mounting into tanks, vessels, sumps and tubes or silos and hoppers
- Output: NPN, PNP
- Setting using a magnetic pen
- High stability upon high sensitivity (possible to use for materials with εr ≥ 1.3)
- Indication by two LEDs
- Versions for explosive areas
- Supply: 8…9 VDC
- Protection class: IP67 / IP68
Capacitive level sensor Reka 2000 is designed to be submerged into liquids, made out of non-toxic polypropylene (PP)
Capacitive oil level sensor PWP-420.60, designed for oil, liquid fuel, food oil and other fluid level control in metal and nonmetal tanks. Special sensor versions are suited for work in aggressive fluid mediums (acids, alkalis).
- SET-1000 + SET/OSK2 is designed for oil detection on water surface
- Can be used in tanks where water level is alternating
- Control device SET-1000 is a one-channel level switch
- SET/OSK2 sensor detects more than 15 mm width hydrocarbon layer on water surface
- Polypropylene floats
- ATEX certified
- Wall-mounted, IP67
- Supply: 230 VAC, 50/60 Hz
- Addressable digital gas detection system (Sensor-Board SB) for combustible, toxic and refrigerant gases.
- Communication: RS-485 interface for stable and secure system networking
- Precise Detection: High accuracy thanks to digital signal processing
- Easy maintenance with X-Change: Plug & Play systems for fast, convenient service
- Robust Design: Reliable with IP65 even under extreme conditions
- Lokaset 20 is designed for high wastewater level detection in septic tanks
- Easy to install, does not need calibration
- Switch output
- Visual and acoustic alarms
- Wall-mounted
- Supply: 230 VAC, 50/60 Hz
Devices of SPECTRO-3 series are designed to detect “true-color” (human color reception). Sensors can be used in AC or DC modes, with internal or external light source.
The sensors of the COAST Series (COlor And STructure) are hybrid sensors that comprises two sensors that only are synchronized by the LED ring light but otherwise operate independently of each other. Both sensors can be connected to a PLC or to a PC.
- Warning- and Sensor-Board WSB for digital and analog sensor technology for the precise detection of combustible, toxic and refrigerant gases.
- Versatile alarm function: Alarm and fault relays (30 V)
- Intelligent interfaces: RS-485 interface with DGC or Modbus protocol
- Precise signal transmission: 4–20 mA input and output for reliable communication
- Flexible: Connection of up to 3 sensors (2 digital)
Compact sensor VA 525 for measuring compressed air or nitrogen inline.
- 4...20 mA and pulse or a Modbus RTU (RS 485) interface as standard
- Optional interfaces such as Modbus TCP (Ethernet), PoE, M-Bus available
- Pressure range up to 16 bar
- Temperature range up to 60°C
- For speeds up to 224 Nm/s
- Integrated display to show the measured values
- Available from 1/4" to 2''
- Settings adjustable via the keys of the display
- Main counter can be reset via the display
- RS-485 (Modbus) protocol temperature and humidity sensor
- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 5...95 %RH
- Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (5...95 %RH) / ±0,4 °C (-10...+60 °C) / ±0,6 °C (-20...+60 °C)
- Resolution: 12 bits for temperature and humidity
- Long-term stability
- Warranty: 3 years
SI-COLO 15 color digital sensor works according to 3-color principle using LED diode as light source. Color sensor parameters can be set using a PC via RS232 interface.
SI-COLO4 31 color digital sensor works according to 3-color principle using LED diode as light source. Color sensor parameters can be set using a PC via RS232 interface.
- 1-Wire protocol temperature and humidity sensor
- Temperature measurement range: -20...+60 °C
- Humidity temperature range: 10...90 %RH
- Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (10...90 %RH) / ±0,4 °C (-10...+60 °C) / ±1 °C (-20...+60 °C)
- Resolution: 14 bits for temperature, 12 bits for humidity
- Long-term stability
- Warranty: 3 years
- 1-Wire protocol temperature and humidity sensor
- Temperature measurement range: -20...+60 °C
- Humidity temperature range: 10...90 %RH
- Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (10...90 %RH) / ±0,4 °C (-10...+60 °C) / ±1 °C (-20...+60 °C)
- Resolution: 14 bits for temperature, 12 bits for humidity
- Long-term stability
- Warranty: 3 years
- Connection: RJ-11
- RS-485 protocol temperature and humidity sensor
- Temperature measurement range: -20...+60 °C
- Humidity temperature range: 5...95 %RH
- Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (5...95 %RH) / ±0,4 °C (-10...+60 °C) / ±0,6 °C (-20...+60 °C)
- Resolution: 14 bits for temperature, 12 bits for humidity
- Long-term stability
- Warranty: 3 years
- Connection: RJ-45
- 1-Wire protocol temperature sensor
- Temperature measurement range: -40...+85 °C
- Accuracy: ±0,5 °C (-10...+85 °C) / ±2 °C (-40...+85 °C)
- Resolution: 12 bits
- Very low current consumption
- Warranty: 3 years
- Protection class: IP65
- 1-Wire protocol temperature sensor
- Temperature measurement range: -40...+85 °C
- Accuracy: ±0,5 °C (-10...+85 °C) / ±2 °C (-20...+85 °C)
- Resolution: 12 bits
- Very low current consumption
- Warranty: 3 years
- Connection: RJ-11
- Electrode level sensor AUREGIS LJ-B for level measurement
- Process temperature: From -30 to 180°C
- Electrode level sensor AUREGIS LJ-DSH-2R, LJ-DSH-3R for level measurement
- LJ-DSH-2R - 2 electrode level sensor; LJ-DSH-3R - 3 electrode level sensor
- Process temperature: -20...+80 °C
Electrode level sensor AUREGIS LJ-E3 with 3 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.
Electrode level sensor AUREGIS LJ-E5 with 5 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.
Electrode level sensor AUREGIS LJ-EB for liquids level measurement. By request sensor can be made with 2 to 5 electrodes with different lengths.
- Electrodes: Stainless steel DIN 1.4301 (AISI 304)
- Insulator: Teflon
- Electrode extension: Stainless steel DIN 1.4301 (AISI 304)
- Process connection: Stainless steel DIN 1.4301 (AISI 304)
- Connection head: Aluminum alloy
- Electrode length: Standard – 1000 mm or by request
- Process connection: R1 1/2“
- Process temperature: -30...+180 °C
Fluid level electrode probes SKC-201, designed to control conductive fluid level in open and pressure tanks. Electrodes – rod or flexible (rope with plastic coating). Probe head is made of acid-resistant steel. Maximal electrode count – 3. Insulation is made out of high quality plastic, enabling the probe to be used in food industry. Standard version probes are coated with plastic (FEP, PU, PVDF), lowering the residue collection (slime, carbonate, foam, etc.). Two modifications are available – with connection cable (P) and connector (G).
Fluid level electrode probes SKC-101, designed to control conductive fluid level in high temperature and high pressure medium. Modifications differ by permissible operating temperature. Recommended to use with Elcluwo 112...114 level alarms.
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached.
- Weight: 163 g; Buoy volume: 280 cm3: Maximum pressure:< 1 bar
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
- Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
- Double water- and air-resistant sealant increases protection against infiltration even more
- Weight: 250 g; Buoy volume: 430 cm3; Maximum pressure: < 1 bar
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
- Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
- Double water- and air-resistant sealant increases protection against infiltration even more
- Weight: 1050 g; Buoy volume: 990 cm3; Maximum pressure: < 2 bar