- Supports devices: NAT 8252, NAH 8254, NAR 8258, ECL 8439
- Fast and easy operation via Android app “Sensor Master Communicator SMC”
- Read out of sensor data
- Parametrization of switich points on NAx pressure switches
- Measuring range adjustment on submersible pressure transmitter ECL
- Reset pressure measurement instruments to factory settings
- Ambient temperature: 0...40 °C
- Supply: 5 V (USB)
- Communication: Bluetooth Low Energy
- 2 analog outputs (operating simultaneously):
1. Current 4...20 mA or 0...20 mA (active output, cannot be supplied in two-wire current loop);
2. Voltage 0...10 V. - Soft start/stop (ramping) or a triangular wave generator triggered manually or automatically after switching power on
- 7-segment LED display with adjustable brightness
- Optional RS485/RS232 serial interface (galvanically isolated, MODBUS-RTU communication protocol)
- Password protection
- High accuracy and immunity to interference
- Supply: 230 VAC or 24 VAC/VDC
- Panel housing 96 x 48 x 79 mm
- Protection: IP65 (front) / IP20 (back)
- Thermosetting cabinet with double doors. The cabinet dimension: 600 x 500 mm (max 2x 5,5 kW) or 800 x 600 (max 2x 7,5 kW; ... max 2x 22 kW).
- Plinth or foundation for fixing the cabinet.
- PLC controller with a display that changes the backlight depending on operating mode.
- Program saved in the controller and on the SD card, enabling transferring the program to another controller in the event of a failure.
- Router equipped with a 2G / 3G / 4G / LTE modem, 1 LAN 10 / 100 Mb/s port and radio module in the 802.11 b/g/n standard, supporting MIMO 2x2.
- Meter to measurements electric quality parameters in 3 phase systems
- Programmable display pages
- 3 programmable alarm outputs and 1 pulse output
- Digital transmission to the master system through the RS-485 interface
- USB for configuration by using free eCon software
Reactive power controller RMB-10S. The device is designed for reactive power compensation battery control. Version with 6 switch outputs is available.
- For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
- Default calibration R-404a
- Range 0...1000 ppm
- Resolution 1 ppm
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
- Default calibration R-404a
- Long-life MOS sensor
- Range 0...1000 ppm
- Resolution 1 ppm
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- MOS gas sensor
- Detected gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R1234yf, etc.
- Standard calibration: R-404a
- Range: 0...1000 ppm HFC
- Resolution: 1 ppm HFC
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+60 °C
- Supply: 11..30 VDC / 24 VAC arba 90...265 VAC
- Ethernet connection
- Digital inputs: 2
- 1-Wire input (up to 2 sensors)
- Analog inputs: 2 (0...60 VDC)
- Relay outputs: 2 (NO/NC)
- Webserver
- HTTP and XML API commands
- E-mail alarms, SMTP, SNMP
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...14 VDC
- TC Monitor is remote monitoring software that collects data and controls your TCG (GSM) and TCW (Ethernet) Teracom I/O modules
- User-friendly WEB interface for easy configuration and control
- Free version let monitor up to 10 items
- The monitored parameters can be sensors, digital and analog inputs and relay outputs
- Graphical and Data dashboards for better visualization
- TC Monitor allows flexible administration of user accounts
- Easy access to the raw data tables, export in .csv format
- Alarm notifications
- User activities log
- Ethernet connection
- Digital inputs: 2
- Relay outputs: 2 (NO/NC)
- Webserver
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...14 VDC
The PD9W is an industrial RS-232 / RS-485 to WiFi and Ethernet converter.
- Communication interfaces: 1x RS485, 1 x RS232, 1x Ethernet and WiFi (802.11b/g/n)
- Modes: AP, STA, AP + STA, AP + LAN, AP + WAN, Route and Bridge
- Work modes: transparent transmission mode, serial port command mode, HTTP Client mode, Modbus TCP<=>Modbus RTU mode and AT command mode
- Configuration the parameters via the WEB server
- RS232 port for RTS/CTS signals
- Hardware Watchdog, Heartbeat
- Electrostatic protection 15 / 8 kV
- Power supply: 5…36 V dc
PD9-Modbus RS485 to Ethernet converter can realize bidirectional transparent transmission between RS485 and Ethernet. It carries ARM processor, low power, fast speed, high stability. Via web-page or software, Rs-485 to Ethernet Converter can realize serial data and TCP/IP data package transparent transmission.
- Communication interfaces: 1x RS485, 1x Ethernet WAN/LAN
- Easy configuration the parameters via the webpage or set-up software
- Compact size, DIN rail mount
- Working mode: TCP server, TCP client, UDP server, UDP client
- Modbus RTU to TCP conversion, Modbus Polling
- DHCP support, IP dynamic or static
- Watchdog function
- Working temperature: -40…85°C
- Power supply: 5…36 V dc
- Digital input: 4 ch. pulse
- Independent modes: OPEN / CLOSED (“Dry contact”) and COUNTER (S0 standard)
- Output: RS-485 MODBUS RTU interface
- Non-volatile memory for counters storage and settings
- Galvanically isolated inputs
- DIN rail mounting
- Protection class: IP40 (connections IP20)
- Operating temperature range: -20…+60 °C
- Power supply: 5…28 VDC
- Modern SCADA system
- Free license allows to work with up to 50 objects (each having 10 variables / tags / atoms)
- Free license supports only one chosen driver (i.e. Modbus)
- Hardware-independent, communicates with all major industry-standard
- Mobile application (in full version)
- 25 year experience in the marketplace - developed by 7-Technologies which belongs to Schneider Electric
Single-use data logger for real-time measurement of temperature, humidity and light. GSM tracking and LTE 4G connectivity for smart logistics worldwide. Free usability of tempmate.®-Cloud for information viewing, reports generation and devices setup. Tempmate-GS2 have 3 models: T, TH and TE, for more information see datasheet.
- Temperature measurement range*: -200…+100 °C
- Relative humidity measurement range*: 0…100 %
- Ambient light measurement range*: 0…10000 lx
- Local storage capacity*: 24200 values for Temperature, Humidity and Light
- Shelf-Life:
- Lithium Battery devices: 12 months (possibility to charge)
- Non-Lithium Battery devices: 6 months (possibility to charge)
- External sensor*: PT100 (cable length: 1m, length of probe is 6cm length, 4 mm in diameter, sensor tip: stainless steel)
- Log interval: User defined: 1 min. to 60 min. (10 min. as standard setting preconfigured)
- Transmission Interval: User defined: 10 min. to 1440 min. (60 min. as standard setting preconfigured)
- Recording Duration:
- Lithium Battery: 90 days (with standard log interval of 10 min. and transmission interval of 240 min.)
- Non Lithium Battery: 60 days (with standard log interval of 10 min. and transmission interval of 240 min.)
- Certifications: CE, EN12830, EMC, RoHS, FCC
- Connectivity: LTE 4G cat 1 with 2G Fallback
- Report Generation: Readable in the Cloud and locally in the device through the USB 2.0 interface
- Location: LBS - GSM Localization
- Recommended Storage Temperature: -15…+25 °C
- Software to work with Comet devices Sxxxx, Rxxxx, UxxxxM, Dxxxx and Mxxxx
- Device settings
- Data download
- Analysis of critical situations
- Presentation of measured data
- Reports
- Database import/export
- Free license
- Flexible spears for grain temperature measurement
- Rigid construction
- Diameter: Ø8 mm
- Penetration depth: up to 12 m
- Digital temperature sensor
- Measurements are done using PC software or handheld reader GW-200
- Temperature spears and cables can be integrated into single system
By means of three light barriers the SI-JET spray jet control systems check the density, symmetry, and cone angle of the spray jet. Choked or incorrectly set nozzles can thus be detected in time. Due to the integrated pressed air facility (at transmitter and receiver side of the fork) these systems are insensitive to dirt accumulation.
- Stable long-life electrochemical cell
- Range 0...50 / 0...2000 ppm SO2
- Resolution < 0,1 / 1,5 ppm SO2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 2 / 5 ppm SO2
- Attached or remote sensor
- Stable long-life electrochemical cell
- Range 0...50 / 0...2000 ppm SO2
- Resolution 0,1 / 1,5 ppm SO2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...50 ppm SO2 / 0...2000 ppm SO2
- Resolution: 0,1 ppm SO2 / 1,5 ppm SO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 11..30 VDC / 24 VAC or 90...265
- Universal datalogger with 3 hardware MiniDIN inputs for connecting temperature and humidity probes and 1 for external CO2 sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- External CO2 sensor, 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures carbon dioxide (CO2) using the integrated sensor.
- Measures barometric pressure using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures carbon dioxide (CO2) using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Measures ambient air temperature and humidity
- Integrates seamlessly into GrainWatch PC Software and displays the ambient weather conditions in real-time
- Selectable double set point
- Selectable TC / Pt100 input (order option)
- Output: relay (control or alarm) and SSR (control)
- PID control
- Self-tuning feature
- Soft-start function
- Offset feature for input
- Heating/cooling control
- Manual control feature
- Two set points
- Input: TC (J, K, T, R, S) / RTD (Pt100)
- Control output: relay or SSR
- Auxiliary output: relay
- PID / ON-OFF control
- Auto-Tuning / Self-Tuning
- Alarm modes: deviation, absolute
- Heating / cooling control
- 4+4 digits high contrast LED display
- Supply: 85…270V AC / DC
- Ambient temperature: 0…50 °C
- Indoor temperature controller of TR series (S+S Regeltechnik, Germany)
- TR-040 (external setting): 0...40 °C
- TR-040U (internal setting): 0...40 °C
- TR-060 (external setting): 0...60 °C
- TR-060U (internal setting): 0...60 °C
- Output: Relay
- Switching capacity: 24...250 VAC (16 A)
- Ambient temperature: -35...65 °C
- Protection class: IP65
- Patented quality product (immersion sensor patent)
- Measuring ranges: multi-range switching with 8 switchable measuring ranges
- Output: 0 – 10 V or 4...20 mA
- Sleeve length: 50, 100, 150, 200, 250, 300, 400 mm
- Supply 24 VAC/ VDC – U var. or 15...36 VDC I var.
- Medium: in liquid or gaseous media
- For aggressive media, stainless steel immersion sleeves must be used
- Ambient temperature: -30…+70 ºC
- Penetration temperature sensor TJ-ST
- Sensor type: Pt100, Pt1000
- Accuracy: A or B
- Measuring range: -30 °C...+180 °C
- Measuring part diameter: Ø 4 mm
- Measuring part length: 100 mm
- Material: stainless steel
- Various sizes are available depending on customer requirements and drawings
- Temperature sensor with penetration probe, “T” type handle and cable connection head
- Various sizes are available depending on customer requirements and drawings
- Sensor type: Pt100, Pt1000, K, J
- Accuracy class: A or B / cl. 1 or 2
- Measuring range: -30...180 °C or -30...260 °C on request
- Sensor’s tube:
- Material: Stainless steel AISI304 (1.4301)
- Diameter: Ø 6 / 8 / 10 mm
- Length: 100, 200, 500, 700, 1000 mm on request
- The total length of the sensor handle is 220 mm
- Connection head:
- Type: M, B (transducer on request)
- Protection class: IP65
The TJ-S temperature sensor is permanently connected to a cable and designed for measuring temperatures from -50°C to 400°C.
Various cable lengths are available.
- Sensor type: PT100, PT1000, NTC, Thermocouples K, J
- Measuring range: -50…+400 °C
- Operating temperature:
- -30...+70 °C (PVC isolation)
- -50...+180 °C (Silicone isolation)
- -50...+400 °C, kabelio -50...+250 °C (Teflon isolation)
- -50...+400 °C, kabelio -50...+400 °C (Fiberglass isolation)
- Cable and connection: 2, 3, 4 wire
- Sensor tube:
- Material: Stainless steel 316 (1.4401)
- Diameter: Ø4 mm
- Length: 120 mm
- Temperature transmitter 5331A with 4...20 mA output, designed for TC, RTD, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5333A with 4...20 mA output, designed for RTD signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5334A with 4...20 mA output, designed for TC, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5334B for explosive Ex atmosphere with 4...20 mA output, designed for TC, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5335A with 4...20 mA HART protocol output, designed for TC, RTD, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5350A with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
- To be mounted into B-type electric head
- Temperature transmitter 5350B for explosive Ex atmosphere with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
- To be mounted into B-type electric head
- Wide temperature range: -10...+1200 °C
- 320 x 240 and 640 x 480 infrared resolution
- 9 or 60 Hz models available
- Sighting: IR-Fusion technology (thermal and visible sighting) for easy alignment and added detail on blended images
- Remote motorized focus
- Multiple field interchangeable lens options available
- GigE Vision interface
- LAN/Ethernet with PoE for communication with the thermal imager provides access to Ethernet, Web server and ThermoView Software
- I/O alarming capabilities
- ThermoView software for industrial automation applications
- Ambient temperatures to 200 °C with high temperature enclosure
- Air purge and accessories available
- Rugged housing, IP67 rated
- Designed to measure the thickness of non-magnetic layers
- Can be used for construction, ships, tanks, piping, boilers, vehicles protective layer quality control
- High accuracy in wide temperature (with compensation) range using the same probe
- Fit for work outside
- Certificate of calibration included
- PD51-A transducer/repeater, designed for conversion of RS232 interface to industrial RS485
- This enables to increase device number in the system and extend its range
Trigger light barriers are mainly used in the field of metal stamping. The TLB series comprises light barriers with infrared light beam (IR) or visible light beam (VIS), in split shape as well as in fork shape (with or without compressed air supply). Characteristic for all light barriers of TLB Series is the external electronics: Pulsating light or constant light amplifier with digital output or analog output (voltage output and current output).
- Simultaneous detection of two gases (please ask for available gas combinations and possible limitations)
- Switch output: 4 x SPDT (2 for each sensor)
- Alarms: LED indicators and buzzers (85 dB)
- Supply: 24 VDC/VAC / 90...265 VAC
- Protection class: IP65
Ultrasonic level meter ULM-53 is designed for continuous liquid (even if polluted), mash and paste materials level measurements in closed and open tanks, sumps, open channels, etc. Adjustments are made with two buttons. State indication by two LEDs. Current (4...20 mA, 20...4 mA) or voltage (0...10 V, 10...0 V) outputs. Xi version is for usage in explosive areas.