  • Measurement speed: 0,6 s (up to 700 people per hour)
  • Integrated sensors: 5
  • IR thermal array, range: 0...100 °C (± 0,3 °C)
  • Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
  • Relative humidity sensor, range: 0...100 % (± 3 %)
  • Vibration sensor (for sabotage detection), range: 0,25...5 G
  • Distance sensor, resolution: 1 mm
  • Dew point calculation
  • Relay inputs: 2
  • Relay outputs: 2
  • LED indication, buzzer (85 dB)
  • Communication: Ethernet (10/100)
  • Connector (RJ45) for connection of other Kentix devices
  • Webserver
  • Software: remote connection with AlarmManager-PRO
  • E-mail, SNMP alarms, Rest API
  • SD card slot (to save pictures, card up to 128 GB)
  • PoE
  • Optional: RFID reader
  • Optional: wall bracket, cable

Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.

  • Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
  • Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
  • CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
  • Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
  • Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
  • Air quality (VOC) measuring range: 0…100 %
  • Data output:  galvanically separated RS-485 Modbus RTU interface
  • Variants: with / without LCD display
  • One sensor covers about 30 m² of room area
  • Power supply: 24 V ac/dc (200 mA)
  • Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
  • Suitable for ATEX Zones 2 and 22
  • Electrochemical gas sensor
  • Range: 0...100, 0...300, 0...1000, 0...5000 ppm NH3
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life pellistor (catalytic bead) sensor
  • Range: 0...15% vol. (0…100% LEL)
  • Resolution: 0.1% vol. or 1% LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -10...+50 °C
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life photoacoustic or optical NDIR sensor
  • Range: 0...10 000 ppm / 0...40 000 ppm / 0...5 % vol (0...100 % on request)
  • Resolution: 1 ppm / 10 ppm / 0.01 % vol. CO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+60 °C; 0….100 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...300 or 0...1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Detected gases: hydrogen, methane, acetylene, propane, butane
  • Default calibration: methane CH4
  • Stable long-life metal-oxide / pellistor sensor
  • Range: 0...100% LEL
  • Resolution: 0,1 / 1 % LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...10 / 0...200 / 0...1500 ppm
  • Resolution: 0,1 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C; up to 100 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Detectable gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234ze and similar
  • Stable long-life metal-oxide sensor
  • Range: 0…1000 / 0…2500 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+60 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...100 ppm, 0...2000 ppm H2S
  • Resolution: 1 ppm H2S
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C; 15…90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide / pellistor sensor
  • Range: 0...100% LEL CH4
  • Resolution: 0,1 / 1 % LEL CH4
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0…250 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+50 °C; 15…90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life optical NDIR sensor
  • Range: 0…1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...25 % vol O2
  • Resolution: 0,01 % vol O2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+60 °C; 5…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Highly sensitive Photo Ionization Detector (PID) sensor
  • Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
  • Default calibration: Isobutylene
  • Range: 0…40 / 0…200 ppm isobutylene
  • Resolution: 0,01 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide sensor
  • Detectable gases: acetone, ethanol, toluene, xylene etc.
  • Default calibration: toluene
  • Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
  • Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC

Vertical, stainless steel, float level sensor with float protection against mechanical impact, designed for level control.

  • Material of float: stainless steel AISI 316 SS
  • Max. temperature: -30...+105 °C
  • Switch rating: 50 VA
  • Switching voltage: 230 AC / DC
  • Flow monitor for liquid media in the range of 4…400 cm/s with analog (4…20 mA) and status output (PNP, NPN) for monitoring a flow threshold
  • Ten LEDs indicate flow and contact closure
  • Equipped with 2 control buttons for setting the switching point
  • Available with 65 mm and 125 mm mounting depths
  • Rugged design for industrial environments, IP67
  • Calorimetric measuring principle
  • Units freely selectable via keys at the display
  • Display shows 2 values at the same time, twistable by 180 ° degree
  • Integrated Modbus interface enables connection control systems, SCADA
  • M-Bus (optional)
  • Analog output 4...20 mA
  • Pulse output (galvanic isolation)
  • High measuring accuracy (ideal for leakage measurement)
  • Flow sensor suitable for evaluation unit NLSW®45-6 and NLSW®45-6.1
  • Thread: PG7, optional accessories available
  • Material: stainless steel V4A
  • Media temperature: optional up to 400°C
  • Protection class sensor: IP50
  • Insertion depth: 50 mm, 130 mm, 165 mm, 300 mm
  • Compressive strength: 10 bar
  • Applications of flue gas analyzer Si-Ca 130: for commercial and residential boilers and water heaters
  • Detectable gases: O2, CO, CO2, NO, NOx
  • Up to three gas sensors
  • CO measurement up to 8000 ppm
  • Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation)
  • Color display screen with buttons
  • Communication: Bluetooth (mobile App), remote printer
  • Measurement storage: smartphone
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Protection class: IP42
  • Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
  • Operating temperature: -5…+45 °C
  • Sensor protection by pump stopping

Fluid level alarm Elcluwo 111S, designed for usage with conductometric probes for fluid level alarm and control.

 

Technical specifications

  • One or more level control
  • Switch output 2A, 250 VAC
  • Probe supply from isolated ~12 V source
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)

Fluid level alarm Elcluwo 112S, designed for usage with conductometric probes for fluid level alarm and control, depth pump protection.

 

Technical specifications

  • One or more level control
  • Switch outputs: switching + NO 2 A / 250 VAC
  • Probe supply from isolated ~12 V source
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)
  • One or more level control
  • Switch outputs: switching + 3 x NO 2 A / 250 VAC
  • Probes: galvanically isolated, max. 2mA, 5V~ 100 Hz
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)
  • Supply: 230 VAC / 24 VAC
  • One or two level control
  • Switch outputs – switching + 5 x NO, 2A / 250 VAC
  • Probes: galvanically isolated, max. 2uA, 5V~ 100 Hz
  • Adjustable sensitivity
  • Available modes – filling, draining, dry flow, overflow, two/three pump control and others
  • Valve or gate control
  • Adapted for work with various probes – SKS 401, 201, 101, SW-01 and others
  • Mounted on standard rail (35 mm)
  • Supply: 230 VAC / 24 VAC

The FPI 8237 IO-Link Flush Membrane pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel 1.4462. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.

  • Measuring range: -0,5...0,5 to 0...100 bar
  • Output signal: IO-Link 1.1, COM3, min. process cycle time 1 ms, Smart Sensor Profile ED2, 2 Switching outputs PNP / NPN / Push-Pull configurable
  • Accuracy at 25°C typically: ± 0.5 % FS typ.
  • Measuring principle: Thin-film-on-steel
  • Media temperature –10... +125 °C
  • Ambient temperature: –10...+125 °C
  • Protection class: IP65, IP67
  • Applications: Hydraulics, Machine tools, Process technology, Food industry, Water treatment

The FPT 8236 pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.

  • Measuring range: 0.5...0.5 to 0...100 bar (-5...10 to 0...1500 psi)
  • Output signal: 4...20 mA, 0...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
  • Accuracy at 25°C typically: ± 0.5 % FS typ.
  • Membrane in Duplex steel 1.4462
  • Pressure connection: G1/2” male, flush membrane
  • Media temperature –10... +125 °C
  • Ambient temperature: –10...+125 °C
  • Applications: Machine tools, Food Industry, Process technology, Water treatment, Hydraulics

The frame light barriers of FLB Series are used for the measurement of smallest unguided parts.

  • Gas measuring, monitoring and warning controller (Multi-Sensor-Controller MSC) for reliable detection of combustible, toxic and refrigerant gases
  • Flexible control: 3 relays (SPDT, potential-free, 250 V)
  • Intelligent Communication: RS-485 interface with DGC and Modbus protocol
  • Precise signal transmission: 4–20 mA input and output for seamless system integration, up to 3 sensors including remote
  • Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
  • Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
  • Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
  • Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
  • Data converter which connects reader in safe zone with network switches and temperature cables/spears in dangerous zone
  • Input: 4 x temperature cables (from switches GWNET11 and cables GWSL 1100 or GWSL 2100)
  • Output: Modbus RTU, RS-485
  • Reads data from 68 individual temperature cables and spears
  • Supply: 230 VAC / 115 VAC
  • Protection class: IP66
  • Certificates: IECEx, ATEX
  • Works as a multiplexer, enabling 4 additional temperature cables or spears to be connected to GWAB11 converter
  • Another GWNET11 can be connected in parallel, further expanding inputs of GWAB11 by 4
  • Operating temperature: -20...+50 °C
  • Protection class: IP66
  • Certificates: IECEx, ATEX
  • Grain temperature monitoring system for steel and concrete bins
  • Digital sensors with 2-wire bus
  • Sensor spacing: 2 or 3 m
  • Diameter: Ø9,8 mm
  • Length: 1...35 m
  • Tensile strength: ≤ 2,5 t
  • Operating temperature -20...50 °C
  • Maximal surface temperature 85 °C
  • System is ATEX-, IECEx- and GOST-R approved
  • ATEX approval code: Ex II 1D Ex ia IIIC T85°C
  • Grain temperature monitoring system for steel and concrete bins
  • Digital sensors with 2-wire bus
  • Sensor spacing: 2 or 3 m
  • Diameter: Ø17 mm
  • Length: 1...100 m
  • Tensile strength: ≤ 8 t
  • Operating temperature -20...50 °C
  • Maximal surface temperature 85 °C
  • System is ATEX-, IECEx- and GOST-R approved
  • ATEX approval code: Ex II 1D Ex ia IIIC T85°C

Automatic portable solid state particle (dust) meter EMIOTEST 3114 is designed for periodic solid state particle concentration measurement in closed channels, i.e. flue gas, and perform other functions:

  • Periodic measurement of solid state particle concentration in stationary sources of emission
  • Solid state particle concentration measurement in gasses
  • Testing of dust removal equipment
  • Gas flow rate measurement
  • Calibration and periodic control of automatic systems (AMS) by measuring the emission and mass stream of dust
  • Dioxins, furans, PAH, mercury concentration measurement
  • Heavy meal, HCL, HF concentration measurement

Kuhlmann Ground Thawing Blankets are durable and weatherproof, designed to thaw frozen ground and soil, pipes, and protect equipment from freezing. They also work as curing blankets for various construction purposes.

Technical specifications:

  • Durable PVC materials.
  • Fixed temperature (70°C).
  • 2-meter power cable.
  • Special sizes produced upon request.
  • IP67 Class.
  • In normal conditions the mat thaws up to 30 cm of soil in 24 hours - or up to 60 cm in more sandy soil/ground.
  • CO2 concentration measurement range: 0...5000 ppm
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Internal sensor
  • GSM modem (GPRS)
  • SMS and JSON messages can be sent via GPRS data connection
  • Messages can be sent on alarms and periodically
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate of manufacturer included
  • Ambient temperature: -20...+60 °C
  • Supply: 5200 mAh LiIon battery
  • Protection class: IP20
  • Warranty: 3 years
  • Digital inputs: 2
  • 1-Wire input (up to 8 sensors)
  • RS-485 input (up to 8 sensors)
  • Analog inputs: 4 (2 x 0...10 VDC, 2 x 0...10 VDC / 4...20 mA, WEB control)
  • Relay outputs: 4 (NO/NC)
  • Setup via USB or SMS
  • Data logger for up to 52 000 records
  • Webserver
  • Periodical upload of data logger file to a remote HTTP server
  • HTTP Post, HTTP API
  • SMS alarms (up to 5 numbers)
  • E-mail alarms (up to 5 recipients), SMT with TLS support
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...24 VDC
  • Digital inputs: 2
  • 1-Wire input (up to 4 sensors)
  • Analog inputs: 2 (0...60 VDC)
  • Relay outputs: 2 (NO/NC)
  • Setup via USB or SMS
  • Webserver
  • HTTP Post, HTTP API
  • SMS alarms (up to 5 numbers)
  • E-mail alarms (up to 5 recipients), SMTP with TLS support
  • Operating temperature: 0...40 °C
  • Warranty: 3 years
  • Supply: 10...28 VDC
  • Used with grain temperature sensor cables GWSL 1100, GWSL 2100 and spear sensors GWTL-R
  • Cable length up to 200 m (including the temperature cables)
  • Up to 32 values of temperatures are shown in cycle
  • Weight: 240 g (with batteries)
  • Case material: ABS
  • Supply: 2 x AA (battery life circa 1 year)
  • Operating temperature: -20...+40 °C
  • Enables the PC to be connected to HART interface, i.e. to configure a device
  • Active operation: current loop is supplied
  • Passive operation: used in an existing current loop
  • Included HART-Tool software
  • Supply: from USB
  • Galvanic isolation between USB and HART
  • Communicates with devices supporting HART and LHP interfaces
  • Supports universal, common commands
  • HART connector: BNC
  • Supply: 9 V accumulator (charged via USB)
  • Operating temperature: -20...+50 °C
  • Operating humidity: 0...80 % RH
  • Protection class: IP40

High-frequency contrast sensors for UV, VIS and IR range.

SM400-4-TH humidity and temperature sensor supports MODBUS RTU protocol over the RS-485 interface. Suitable for environmental quality monitoring offices, server room, data center and indoor air

  • Changeable communication parameters
  • Non-volatile memory for all settings
  • Operating temperature range: -20…60°C
    • Accuracy (min): ± 0.4 °C (in -10…+ 60 °C range)
    • Accuracy (max): ± 0.6 °C (in -20…+ 60 °C range)
    • Resolution: 0.1 °C
  • Operating relative humidity range: 10…90% (non-condensing)
    • Accuracy (min): ± 3.0 % RH (in 20…80 % RH range)
    • Accuracy (max): ± 5.0 % RH (in 10…90 % RH range)
    • Resolution: 0.1 % RH
  • Ingress protection: IP20
  • Operating voltage range: 4.5…26 VDC
  • Long-life metal-oxide gas sensor
  • Range 0...100 % LEL H2
  • Resolution 0,1 % LEL H2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor options
  • Stable long-life electrochemical gas sensor
  • Range 0...100 / 0...1000 ppm H2S
  • Resolution 0,1 / 1 ppm H2S
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 10 / 20 ppm H2S
  • Stable long-life electrochemical gas sensor
  • Range 0...100 / 0...1000 ppm H2S
  • Resolution 0,1 / 1 ppm H2S
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor option
  • Electrochemical gas sensor
  • Range: 0...100 / 0...2000 ppm H2S
  • Resolution: 0,1 / 1 ppm H2S
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

The Kuhlmann Electro-Heat IBC Immersion Heater is an efficient solution for heating liquids in Intermediate Bulk Containers (IBCs), addressing viscosity challenges to enhance industrial productivity. Suitable for a variety of substances, it ensures consistent heating and easy liquid management. Its applications span multiple industries, including chemical processing, pharmaceuticals, food and beverage, and oil and gas. Constructed with durable stainless steel and featuring precise temperature control, this immersion heater combines performance with longevity.

Technical Specifications:

  • Surface load: 2.2 W/cm²
  • Power: 2000W
  • Supply: 230V 1-phase
  • Stainless steel tube element AISI 316L (1.4404)
  • Length of element: 950mm
  • Diameter of element: ø100mm
  • Heated zone: 300mm
  • Integrated PT100 sensor
  • Minimum level of liquid during heating: 500mm (half full)
  • Cable between heater and control unit: ~2800mm
  • Digital controller: 0-90°C

An IBC silicone base heater efficiently heats up contents in an IBC container, making it easy to discharge viscous or semi-solid products with minimal waste. The 2700W heater can heat water from 15°C to 70°C in less than 40 hours. Kuhlmann’s durable silicone base heater fits various IBC containers and is easy to install and use. It can also be mounted with a digital temperature controller for precise temperature control.

Technical Specifications:

  • Dimensions: 1035 - 851mm.
  • Materials: 100% silicone.
  • 1,5 meter power cord with no plugs.
  • 0-150°C PT100 Sensor System temperature controller (additional product).
  • Heats water from 15°C - 70°C in less than 40 hours in a fully loaded IBC Container.