  • Temperature sensor AUREGIS TJ-1 is inextricably connected to the cable
  • It is designed for temperature measurement from -50°C to 400°C
  • Various sizes are available depending on customer requirements and drawings
  • Sensor type: PT100, PT1000, K, J, PTC, NTC, Ni120, Ni1000

2, 3 or 4 axes ADR10 series indicators for digital systems, linear displacement measurements, movement measurements, positioning detection. These indicators are used with optical and magnetic linear encoder scales ALS or MLS. Error compensation.

 

Application:

  • Lathes
  • Milling machines
  • Plate metal processing mills
  • Grinding machines
  • Erosion machines
  • Mechanical processing centers
  • Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
  • THD factor
  • Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
  • Digital output: RS-485 MODBUS (option)
  • Protection class for front side: IP65
  • Supply: 85...253 VDC/VAC
  • Backlit LCD display
  • Dimensions: 96 x 96 x 77 mm
  • T22CT can be used for network analysis, monitoring and measuring of non -sinusoidal and distorted networks AC current
  • Variations of measuring current range (A): 0...50 / 100 / 150 / 200 / 250 / 300 / 400 / 500 / 600 / 750
  • Output: 4…20 mA or 0…20 mA (Proportional change to input current)
  • Frequency range of Measuring current: 50…60 Hz
  • High electric isolation between primary conductor and output
  • Mounting onto 35 mm DIN rail by means of optional supply of snap on mounting
  • Auxiliary power supply: 24 V DC, ± 15%
  • Protection class: IP20
  • Operating temperature and Humidity: 0…+70 °C, 0...95% RH without condensation
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL (0...2,5 % vol.) C2H2
  • Resolution 0,1 % LEL (25 ppm) C2H2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor
  • The Si-83 tank pump is perfect for residential A/C (up to 20 kW) and heating units (up to 40 kW)
  • Max discharge head: 5,4 m
  • Max pressure: 5,7 m
  • Tank volume: 2 L
  • Automatic turn on specific level in tank
  • Overdraft level safety switch
  • Stainless steel motor shaft
  • Protection class: IP44
  • Max condensate temperature: 55 °C
  • Max condensate acidity: pH > 2,5 (Gas condensing boilers)
  • Quick installation with mobile app
  • Portable, small dimension temperature meter with a probe
  • The probe can be 1,5 m, 3 m or of specified length
  • Temperature measurement accuracy: ±1 °C
  • Temperature measurement range: -50...+150 °C
  • LCD screen
  • 2 year warranty
  • Supply: 1x6LF-22 (9 V)

The SV600 Fixed Acoustic Imager enables users to continuously detect, locate and visualize unheard and unseen air and gas leaks or changes in sound signatures before they become costly problems.

  • 64 MEMS digital microphones for image of leaks
  • Powerful processor for onboard real time processing: Sound classification, Frequency filtering, dB values and sound intensity mapping, Event triggering
  • Measuring distance: 3…15 m
  • Integrated visual light camera
  • The SV600 can be mounted on moving applications – including as a Boston Dynamics Spot
  • Can be mounted close to any equipment or asset, to any area of the production line, or where human access is restricted or dangerous
  • Option for IO support through fieldbus coupler
  • Integration: HTTP REST API, Modbus
  • Operating temperature: -20…+50 °C
  • Protection class: IP54
  • Communication and power supply: Ethernet RJ45, POE IEEE 802.3at
  • Air flow monitor with automatic reset function (alternatively available with error memory)
  • Switching point continuously adjustable, switching output 2 NO/ 2 NC
  • Robust sensor design, high sensor protection class IP67, sensitive and fast air flow detection
  • Examples of areas of application: Monitoring of heating registers, humidifiers, air curtain systems, dampers, fans, DDC
  • Operating on the Pitot tube principle
  • Insensitive to airflow direction
  • Accuracy: 2 %
  • Pairs well with HK Instruments DPT-FLOW transducers
  • Connection: 1/4” OD tubing
  • Operating temperature: 5...95 °C
  • Round or rectangular duct
  • Various duct size options (up to 1200 mm)
  • Air velocity measurement range: 0...2 / 0...10 / 0...20 m/s (selectable via jumper)
  • Temperature measurement range: 0...50 °C
  • Output: 0...10 V / 4...20 mA
  • Option: LCD screen
  • Option: relay output
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...+50°C
  • Protection class: IP54
  • Maximal pressure measurement range: 0...7000 Pa
  • Air flow and velocity measurement
  • LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 9 V battery
  • Operating temperature: 10...+50°C
  • Protection class: IP54
  • Maximal pressure measurement range: 0...1000/2000/5000/7000 Pa
  • Air flow and velocity measurement
  • Output: 0...10 V / 2...10 V or 4...20 mA
  • Option: autozero function and LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 10...35 VDC
  • Operating temperature: -40...+50°C (see datasheet)
  • Protection class: IP54
  • Universal airflow monitor with Safety Integrity Level 1 (SIL1) according to IEC 61508/IEC61511 (alternatively device with SIL2 certification available)
  • With switching output suitable for control cabinet installation
  • Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
  • Large measuring range from 0.1 ... 30 m/s, quick and easy commissioning
  • Example areas of application: Monitoring heating registers, air curtain systems, dampers, fans, DDC

Ambient humidity and temperature logger TERMIOPLUS-S with external sensor is designed for logging of ambient humidity and temperature in its internal memory.

  • Temperature range: -30...+70°C
    • Temperature accuracy: In range -30...+70 °C: ± 0,3 °C
    • Resolution: 0.1
  • Humidity range: 0...100 % RH
    • Humidity accuracy: ±2 %RH at 25 °C (30…70 %RH); ±3 %RH at 25 °C (10…90 %RH); ±4 %RH at 25 °C (0…100 %RH)
  • Memory: 32000 (16000 temperature and 16000 humidity)
  • USB interface for data download
  • Logging interval: 15 s...10000 min
  • Supply: 2xAA battery, 3.6 V
  • Battery lifetime: 1 one year with 30 min. interval recording at +10 °C
  • Size: 45 x 100 x 19 mm
  • Long-life MOS or electrochemical gas sensor
  • Range 0....1000 ppm NH3
  • Resolution 1 ppm NH3
  • Outputs 4...20 mA / 0...10 V, RS-485
  • Stable long-life metal-oxide gas sensor
  • Range 0....1000 ppm NH3
  • Resolution 1 ppm NH3
  • Default alarms at 25 ppm / 35 ppm NH3
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Electrochemical gas sensor
  • Range: 0...100, 0...300, 0...1000, (0...10000 on request) ppm NH3
  • Resolution: 1 / 2 / 5 ppm NH3
  • Sensor lifetime: > 2 years
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -10...+50 °C
  • Supply: 11..30 VDC / 24 VAC or 90...265 VAC
  • Metal-oxide gas sensor
  • Range: 0...1000 ppm NH3
  • Resolution: 1 ppm NH3
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+50 °C / 15...90 %RH
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

Astronomical digital clocks RAT-TPA1B are applied for switching on and off the lightning or other electrical receivers in accordance to sunset and sunrise with an option to program a night break, which means a temporary switching off of the receivers for savings purposes

  • 52 programs, holiday mode
  • Automatic summer/winter digital clockover
  • Automatic transfer of weekdays
  • Sealable cover of the front panel, easy setting by 4 buttons
  • Backlighted LCD display (can be turned off)
  • 10-year power reserve (internal lithium battery which can protect real time clock and all the settings when the electric power supply is off)
  • Number and type of contacts: 1 CO
  • Rated load: 16 A / 250 V AC
  • Direct mounting on 35 mm rail mount acc. to EN 60715
  • Compliance with standards EN 60730-1, EN 60730-2-7, Directive RoHS

The ATEX LB Series Drum Heater is engineered for safe and efficient heating in explosion-proof environments. Designed for drums in Zones 1, 2, 21, and 22, it delivers reliable performance with self-limiting heating technology. Ideal for maintaining low-temperature processes and frost protection, it features robust, anti-static PVC fabric and a user-friendly ATEX-certified junction box. Perfect for industries handling volatile chemicals or requiring stringent safety standards.

Technical Specifications

  • Certification: CETS 23 ATEX 030 X; CETS 23 ATEX 031 U
  • Zones: Suitable for Zones 1, 2, 21, and 22
  • T-Class: T6, T5, T4, T3, T2, T1
  • IP Rating: IP65 for dust and water resistance
  • Operating Temperature: 65°C (energized) / 85°C (de-energized)
  • Ambient Temperature: -20°C to +55°C
  • Power Output: Self-limiting heating cable, adjustable to drum size
  • Materials: Anti-static, water-repellent PVC fabric (B2 Flame Retardant)
  • Connection Cable: 5m, 3G1.5mm² with ATEX-certified junction box
  • Available Sizes: For 200/220L drums
  • Applications: Frost protection, temperature maintenance, chemical processing

Solid drilled threaded thermowells, protective cases:

  • Protect and extend the lifetime of temperature sensors and thermometers in processing applications
  • Facilitate the replacement of sensors
  • Allow sensor maintenance without process interruption

The barrel heater is designed to be used for heating the fluids and oil products stored in barrels. Heater is typically used with thermostat (30-110 °C), thermal cut-off (160 °C), cable (3 m) and plug for connection to an earth contact.

The high temperature base drum heater heats metal drums from the bottom, with a diameter of 555mm, compatible with all size metal drums up to 200 liters. It has a built-in thermostat ranging from 50 to 300°C and can be combined with a traditional drum heater for faster heating. It can be used to heat a variety of industrial liquids.

Technical description:

  • Tubular heaters.
  • 50mm. Rockwool isolation.
  • 3-meter power cable.
  • Thermostat: 50° to 300ºC.
  • Weight: 15kg.
  • Can easily be used in conjunction with other drum heaters or insulation jackets for faster heating.
  • IP 54.

Ideal for heating up:

  • Water.
  • Oils and also diesel fuel.
  • Resin.
  • Vaseline.
  • Wax, e.g. lanolin (wool wax or wool grease).
  • Fats.
  • Glue.
  • Adhesives.
  • TOR-80 is designed to measure the dielectric strength of transformer oil and other dielectric fluids according to IEC 60156, ASTM D877 and ASTM D1816
  • Can work autonomously or transfer results to a PC, create a local database, generate reports, plot graphs and print results
  • There is software for the implementation of standard and custom measurement procedures
  • Max output voltage: up to 80 kV, sinusoidal
    • Output voltage measurement accuracy ± 2 %
    • Voltage increase rate: 0,1 to 5 kV/sec (adjustable)
    • Resolution of output voltage indication: 100 V
    • High voltage timeout after breakthrough: 4 ms typical (10 ms max)
  • Operating voltage:  85 – 264 V a.c. (48…63 Hz)
    • Power requirement: 250 VA max
  • Measuring cell volume for oil: 500 cm3
    • Temperature range of testing oil: 0…100 °C
  • Unit operating conditions:
    • Temperature: 0…50 °С
    • Storage temperature: -20… 60 °С
    • Relative humidity: Up to 90 % (without condensation)

Capacitive oil level sensor PWP-420.60, designed for oil, liquid fuel, food oil and other fluid level control in metal and nonmetal tanks. Special sensor versions are suited for work in aggressive fluid mediums (acids, alkalis).

  • SET-1000 + SET/OSK2 is designed for oil detection on water surface
  • Can be used in tanks where water level is alternating
  • Control device SET-1000 is a one-channel level switch
  • SET/OSK2 sensor detects more than 15 mm width hydrocarbon layer on water surface
  • Polypropylene floats
  • ATEX certified
  • Wall-mounted, IP67
  • Supply: 230 VAC, 50/60 Hz

Carbon dioxide (CO2) and temperature transmitter with a display CDT2000 Duct. The device is designed for measurement of air parameters in ventilation channels.

  • CO2 range 400...2000 ppm
  • Temperature range 0...50 °C
  • Carbon dioxide (CO2) range: 0… 2000 ppm or 0…4000 ppm (selectable)
  • Stable long-life optical NDIR sensor
  • Response time: < 2 min
  • Output: 0...10 V arba 4...20 mA
  • Ambient temperature: 0...+ 50 ºC
  • Supply: 24 VAC/ VDC
  • Protection class: IP 30
  • Dimensions: 98 x 98 x 33 mm
  • Application: offices, hotels, convention centers, apartments, shops, etc.

Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.

  • Carbon dioxide (CO2) range: 400...2000 ppm
  • Humidity range: 0...100 % 
  • Temperature range: 0...50 °C
  • Stable long-life optical NDIR gas sensor
  • Range 400...5 000/10 000/50 000 ppm CO2
  • Resolution 10 ppm CO2
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • Stable long-life optical NDIR gas sensor
  • Range 400...5 000/10 000/50 000 ppm CO2
  • Resolution 10 ppm CO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • NDIR gas sensor
  • Range: 0...10 000 ppm CO2
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: 0...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC as options
  • NDIR gas sensor
  • Range: 0...50 000 ppm CO2 (up to 100 % CO2 on request)
  • Resolution: 0.01 % vol.
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -25…+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

Carbon dioxide transmitter CMT is designed for CO concentration measurement. The transmitter is used to control interior ventilation systems.

  • CO range 0...300 ppm
  • Electrochemical (CO) and optical NDIR (CO2) gas sensors
  • Range: 0...100 ppm CO, 0...10000 ppm CO2
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Operating temperature: -20...+50 °C
  • Supply: 24 VDC/VAC
  • Protection class: IP65
  • Electrochemical gas sensors
  • Range: 0...100 ppm CO, 0...20 ppm NO2
  • Resolution: 1 ppm CO, 0,1 NO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Operating temperature: -20...+50 °C
  • Supply: 24 VDC/VAC
  • Protection class: IP65
  • Stable long-life electrochemical gas sensor
  • Range 0....1000 ppm CO
  • Resolution 1 ppm CO
  • Default alarms at 25 ppm / 35 ppm CO
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Stable long-life electrochemical gas sensor
  • Range: standard 0....200 ppm CO, maximal 0...1000 ppm CO
  • Resolution 1 ppm CO
  • Default alarms at 25 ppm / 125 ppm CO
  • Outputs 2 x relays with switch-over contacts
  • Visual and acoustic alarms
  • Long-life electrochemical cell
  • Range 0....1000 ppm CO
  • Resolution 1 ppm CO
  • Outputs 4...20 mA / 0...10 V, RS-485
  • Stable long-life electrochemical gas sensor
  • Range: 0...200 or 0...1000 ppm CO
  • Resolution: 1 ppm CO
  • Outputs 2 x relays with switch-over contacts
  • UART digital interface
  • Visual and acoustic alarms
  • Magnetic key switching
  • Electrochemical gas sensor
  • Range:
  • -- 0…300 ppm CO
  • -- 0...1000 ppm CO
  • Resolution: 1 ppm CO
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

Cartridge electric heating elements are designed to emit large amount of heat in a small area. The heaters are made from heat-resistant steel or brass, with kanthal wire embedded in ceramics and supplemented with magnesium oxide (MgO).

  • The versatile Si 2052 is suitable for replacement of some market standards drain pumps used in cassette type air-conditioning units up to 20 kW
  • Max discharge head: 0,9 m (flow rate = 24 l/h)
  • The single level detection unit can be used as a safety contact (NC 50 VA resistive – 250 V) to cut off automatically the air conditioning system compressor or solenoid valve
  • The centrifugal technology inside this pump is specifically designed for removing condensates continuously, in any kind of environment, with a very low sound level (≤ 30 dBA)
  • Protection class: IPX4
  • Operating conditions: 100 % - continuous duty
  • Lokaset 20 is designed for high wastewater level detection in septic tanks
  • Easy to install, does not need calibration
  • Switch output
  • Visual and acoustic alarms
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • Stable long-life electrochemical cell
  • Range 0...20 ppm Cl2
  • Resolution 0,02 ppm Cl2
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 0,5 ppm/1 ppm Cl2
  • Remote probe option
  • Stable long-life electrochemical cell
  • Range 0...20 ppm Cl2
  • Resolution 0,02 ppm Cl2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • Electrochemical gas sensor
  • Range: 0...10 ppm Cl2
  • Resolution: 0,1 ppm Cl2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC (default), 24 VAC or 90...265 VAC
  • For methane, butane, propane and hydrogen
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarms at 20 / 50 % LEL
  • For methane, LPG, hydrogen and acetylene
  • Can be calibrated for metane, propane and butane
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 x relays with switch-over contacts
  • Default alarms at 10 / 25 % LEL