- 6-range lighting meter AHKF
- Supply: 15...36 VDC (24 VAC for AHKF-U too)
- Sensor: Photodiode in glass casing
- Ranges: 0...500 Lux / 1 kLux / 2 kLux / 5 kLux / 20 kLux / 60 kLux
- Output: 4...20 mA / 0...10 V
- Ambient temperature: -35...70 °C
- Accuracy: < ±10 %
- Temperature accuracy: < ±5 %
- Size: 72 x 64 x 37,8 mm
- Protection type: III (EN 60730)
- Protection class: IP 65 (EN 60529)
- Incremental encoder output: A, B / A, B, Z / A, /A, B, /B / A, B, Z, /A, /B, /Z
- Resolution: 5 / 10 / 25 / 50 μm
- Magnetic measurement (contactless, non-friction system)
- Vibration-resistant
- Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
- Supply: 10...30 VDC / 5 VDC
- Operating temperature: -25...+85 °C
- Protection class: IP67
- Incremental encoder output: A, B / A, B, Z / A, /A, B, /B / A, B, Z, /A, /B, /Z
- Resolution: 5 / 10 / 25 / 50 μm
- Portable reference point
- Stroke values up to 2000 mm
- Vibration-resistant
- Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
- Supply: 10...30 VDC / 5 VDC
- Operating temperature: -25...+85 °C
- Protection class: IP65
Linear encoder MLS110. With cable connection.
Technical specifications
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS110. With spiral connection.
Technical specifications
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS120.
Technical specifications
- Casing integrated into slider
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS130. Very small size.
Technical specifications
- Very small measuring head (in metal enclosure)
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS210. With spiral connection and slider joints.
Technical specifications
- Protection class IP67
- Twin sliders
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS210. With spiral connection.
Technical specifications
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
SpotScan is a linear scanning add-on for RAYTEK, IRCON noncontact IR thermometers ENDURANCE, Marathon MM, Modline 5 and Modline 7
SpotScan is designed to broaden the capabilities of noncontact IR thermometers while scanning measured surface linearly thus measuring wider than one dot target area
The enLink IAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (0.1, 0.3, 0.5, 1.0, 2.5, 5.0 & 10), Barometric pressure, Sound*, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
- Distinguishes between vaping and smoke and counts the number of detections
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours or adaptive (triggered by vape or smoke)
- Power suplly: 12…24V V DC, 0.15 Amp (max)
- Configuration via USB cable / downlink
- Operating Temp. / Humidity: 0…40 °C / 0…95 % RH
- Long-lasting stainless steel screw electrodes
- Measurement range: 7...20 % (-40...+125 °C)
- Resolution: 0,1 %
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Electrode cable: FEP, -50...+200 °C, 5/10/15 m
- Timber temperature compensation
- Electrode length: 15 / 25 mm
- Supply: 11...30 VDC
- Protection class: IP68
The device is designed to measure ambient air pollution by detecting concentration and distribution of particles.
- Inputs: Pt100, Pt1000, 0…4000 Ω, TC (E, J, K, N, R, S), -75…310 mV, -10…10 V, -24…24 mA, potentiometer
- Relay output: 1 x NO contact, load-carrying capacity 6A / 250 V AC.; 6A / 30V DC
- Digital output: RS-485 / MODBUS RTU
- Auxiliary supply: 24 V DC / 24 mA
- Mathematical functions for converting the measured value
- Two-line LCD display (1-row 6 digits, 2-row 5 digits)
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -20...23...60 °C
- Power supply: 40… 253 VAC / 20…300 V D
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL (0...5 % vol) CH4
- Resolution 0,1 % LEL (50 ppm) CH4
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 20 / 50 % LEL CH4
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL CH4
- Resolution 0,1 % LEL CH4
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 20 / 50 % LEL CH4
- Visual and acoustic alarms
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL (0...5 % vol) CH4
- Resolution 0,1 % LEL (50 ppm) CH4
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor options
- Metal-oxide gas sensor
- Range: 0...100% LEL (0...5 %) CH4
- Resolution: 0,1 % LEL (50 ppm) CH4
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+70 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Range: -250...2550 Pa
- Maximal overpressure: 30 kPa
- Accuracy: ±1,4 %
- Pressure and air flow measurements from air diffusers and valves
- Data can be uploaded on your computer for visualization and further analysis
- Over 700 programmed valve types
- Mediums: air and non-aggressive gases
- Operating temperature: -10... +50 °C
- Connection: ø 5 mm pressure hoses
- Can be used with Pitot tube
- 5 year warranty
- Included: calibration certificate, 2 x 2 m PVC hoses
The JX-30 features the Delmhorst EDGE™ App with expanded wood species, customizable settings, and the ability to share data from any location.
- Moister measurement range: 6…60% Wood (Douglas Fir)
- Large, custom display with auto backlight – easy to read under all conditions
- Species: 74 plus 123 additional available through EDGE™ App
- Wood temperature correction (°F/°C)
- Pins/electrode correction (insulated or non-insulated)
- Alarm set point: alerts to user-selected moister level
- On-screen statistics: High, Low, Average, Standard Deviation, View all readings
- Internal calibration check
- “Low Batt” warning with audio
- Auto off timer. Set to 1 min, 4 min or 10 min
- Integral contact pins max 5/16” penetration (use 2498/A-100)
- Compatible with any Delmhorst external electrode
- Color-coded LED’s: adjustable through EDGE ™app
- Power: 2x AA batteries – Alkaline Energizer (included)
- QR code on meter for easy access to support materials
- Size: meter only: 220 mm x 72mm x 39mm; in carry case - 241mm x 165mm x 64mm
- Weight with case: 510 g
- Moisture reading range:
- 4,3…18 % moisture for paper (kraft paper calibration)
- 5…40 % for baled scrap paper (PX-30)
- 0…100 reference scale for obtaining relative moisture levels on other materials without calibration (PX-30)
- Large, custom display with auto backlight and modern light case for comfort use
- On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
- Bluetooth® connectivity to EDGE® app (PX-30). timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
- Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app PX-30)
- Internal calibration check
- “Low Batt” warning with audio
- Auto off timer. Set to 1m, 4m, or 10m
- Compatible with existing Delmhorst prods and electrodes
- Power: 2x AA Alkaline battery (Working hours: 125…150)
- Temperature Correction Range: -18…+124 °C
- QR code on meter for easy access to support materials and meter registration
- Size: meter only 21.97 x 7.24 x 4.06 cm
- Weight: meter only: 218 / 244 gm
- 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration
The Triton ULTRA is a multifunctional vape sensor capable of detecting e-cigarette vapor, marijuana smoke (THC), smoking, loitering, the number of people, gunshots, loud noise, and glass breakage.
- Measured parameters: Temperature, humidity, PM1.0, PM2.5, PM10, TVOC, CO2, NO2, CO, HCHO, sound level
- Customizable instant alarms based on the situation: Email notification, loud alarm, lights, *integration
- Tamper protection: device vandalism, masking and covering
- Real-time monitoring of student loitering via live video streaming
- No license subscription required for use
- The sensor independently performs all measurements and detections and sends alarms itself
- *Integration capability with many third-party systems: TCP, HTTP, MQTT, RTSP
- Event logging of alarms in the device
- Communication: LAN, WiFi
- Operating environment temperature / humidity: 0...44 °C / 0...90% RH (non-condensing)
- Power supply: PoE+ (IEEE 802.3at Class 3 compliance). Ability to connect up to 4 devices in series
Multifunction astronomical digital clocks RDT-TPA2 are applied for switching on and off the lightning or other electrical receivers in accordance to sunset and sunrise.
- 80 programs (astronomical and annual), holiday mode, random mode
- Automatic summer/winter digital clockover
- Automatic transfer of weekdays
- Sealable cover of the front panel, easy setting by 4 buttons
- Backlighted LCD display (can be turned off)
- 10-year power reserve (internal lithium battery which can protect real time clock and all the settings when the electric power supply is off)
- Number and type of contacts: 2 CO (each channel can be assigned an individual program)
- Rated load: 16 A / 250 V AC
- Direct mounting on 35 mm rail mount acc. to EN 60715
- Compliance with standards EN 60730-1, EN 60730-2-7, Directive RoHS
SIRO is an indoor air quality transmitter with a modern design. The transmitter is available with several optional air quality sensors. The modular device can be equipped with CO2 concentration and VOC (Volatile Organic Compounds) measurements or alternatively PM (Particulate Matter) measurement, and in addition, temperature and humidity measurements. SIRO-MOD series models use Modbus serial communication protocol.
- Measuring elements:
- CO2: Non-dispersive infrared (NDIR); 0...2000 ppm
- VOC: Complementary Metal Oxide Semiconductor (CMOS); range: * - see datasheet
- PM: Laser-based light scattering particle sensing
- Temperature: Integrated to CMOS
- Relative humidity: Thermoset polymer capacitive sensing element
- Field configurable outputs for selected measurements; Configuration possible through MODBUS
- Proportional output options including voltage (0–10 V, 0–5 V, 2–10 V) and optional current (4–20 mA); MODBUS
- Offset feature enabling field calibration for each measurement parameter (CO2, VOC, PM, RH, T)
- Optional LCD-display and buttons
- Operating temperature: 0…50 °C
- Protection standard: IP20
- Electrochemical gas sensor
- Range: 0...250 ppm NO
- Resolution: 1 ppm NO
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Stable long-life electrochemical gas sensor
- Range 0...20 / 0...200 ppm NO2
- Resolution 0,02 / 0,1 ppm NO2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 3 / 6 ppm NO2
- Stable long-life electrochemical gas sensor
- Range 0...20 / 0...200 ppm NO2
- Resolution 0,02 / 0,1 ppm NO2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Electrochemical gas sensor
- Range:
- -- 0...20 ppm NO2
- -- 0...200 ppm NO2
- Resolution:
- -- 0,1 ppm NO2 for 20 ppm range
- -- 1 ppm NO2 for 200 ppm range
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- The innovative multiple sensing head interface, which can support up to 8 individually addressable heads per communication box
- reduces sensor cost, simplifies sensor installation and applications troubleshooting, and provides the lowest cost per measurement point
- Real-time thermal line-scanner system for continuous or discrete process measurements
- Up to 1024 measurement points per line
- Fast scan rates up to 150 lines per second (real-time 150 Hz thermal imaging)
- Optical resolution up to 200:1
- Built-in line laser for rapid alignment
- On-board Ethernet TCP/IP communication
- PC independent alarm output
- PC independent 4...20 mA interfaces (3 outputs)
- Wide choice of models and spectral responses
- Rugged, waterproof IP65 enclosure
- Water cooling for ambient temperature up to 180 °C
- Noncontact infrared temperature meter 3i Plus (pyrometer), designed for metalworking industry where casting, hardening, heating take place. Also suitable for ceramics, semiconductor, chemical furnace temperature measurement
- It is a new generation, small size IR device for high temperature measurement
- Precise high-resolution optics guarantee high accuracy, resistant casing let the device survive falls from up to 1 meter height
- That said, measurements can be done in various environments and from various distances
- Noncontact stationary infrared temperature meter CM for temperature measurement
- Range: -20...500 °C
- Outputs: 0...5V, or TC K / J type (chosen while ordering)
- Software “DataTemp Multidrop” for remote monitoring and configuration
- Noncontact infrared thermal meter (pyrometer) ENDURANCE
- for temperature measurement up to 3200 ºC with the resolution of 0,1 ºC
- Outputs: Ethernet, profinet, 0/4...20mA (isolated), RS485, relay 48V and 300mA
- Web server
- Wider area can be measured when used with SpotScan
- Noncontact infrared thermal meter Marathon MM, wide range of accessories for various applications
- Range: -40...3000°C (in fixed ranges)
- Outputs: 0/4...20mA, RS485, mechanical switch
- Temperature measurement range: -40...+2250 °C (different versions)
- Advanced signal processing
- Wide choice of focus distances
- Durable stainless steel IP64 enclosures designed to withstand ambient temperatures from -20 to 85 °C
- Integrated laser sighting
- Galvanic isolated outputs
- Plastic lens option for food application
- Analog input for ambient compensation and adjusting emissivity setting
- USB for easy setup
- Simple, two-wire or digital installation
- Backward compatibility to old Raytek and Ircon in class sensors and accessories
- Noncontact infrared thermal meter Thermalert TX, additional accessories for various applications
- Can be used in an explosive area
- Range: -18...2000 °C (in fixed ranges)
- Outputs: 4...20mA, HART į RS232, mechanical switch (depends on version)
- OilSET-1000 is designed for oil detection in separators, basins and tanks
- Easy to install, does not need calibration
- 2 switch outputs
- Ultrasonic sensor SET/S, 5 meter cable
- ATEX certified
- Wall-mounted, IP67
- Supply: 230 VAC, 50/60 Hz
ORP electrode sensors (glass, epoxy body and submersible)
The CH52-E four-camera multisensor features four independent sensors, providing expansive coverage from a single install point. Each sensor includes a 1 / 2.8” progressive CMOS image sensor, varifocal lens with 2.08x optical zoom, and 30 meters of IR range to provide clear and consistent image quality in any lighting condition. The CH52-E includes four onboard CV25S Ambarella processors to support advanced analytics like AI-powered search, Occupancy Trends, line crossing, loitering, and Person of Interest (POI) alerts. The CH52-E excels at covering hallway intersections and exterior corners of buildings, providing comprehensive visibility and eliminating blind spots while only requiring a single PoE++ cable.
- 30 - 365 days (1TB - 8TB) of onboard storage
- Redundant cloud backup and unlimited cloud-based archiving of footage
- Sensor Resolution: 4 x 5MP (2688 x 1944)
- Protection class / Impact rating: IP66 / IK10
- Operating temperature: -40…+50 °C
- Warranty: 10 Years
- Certifications: FCC, ICES, CE, UKCA, RCM, VCCI, KCC, NOM, CB, NTRA, ICASA, UL/cUL/IEC 62368-1, FY2019 NDAA compliant
- System consists of alarm device SET-1000 and fixed level vibration sensor SET/V
- For usage separators, basins and tanks
- Alarm device SET-1000 is a single-channel level switch
- When used with SET/V, SET-1000 alarms when set high level in tank is exceeded
- ATEX certified
- Wall-mounted
- Supply: 230 VAC, 50/60 Hz
- Stable long-life electrochemical gas sensor
- Range 0...20 % vol O2
- Resolution 0,01 % vol O2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 19,5 / 18 % vol O2
- Stable long-life electrochemical gas sensor
- Range 0...20 % vol O2
- Resolution 0,01 % vol O2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor options
- Electrochemical gas sensor
- Range: 0...25 % O2
- Resolution: 0,01 % O2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 12...36 VDC, 24 VAC or 230 VAC
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 0,3 / 1 ppm O3
- Attached or remote sensor
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...5 ppm O3
- Resolution: 0,01 ppm O3
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
The instrument uses a pH/ORP sensor and RTD Pt100 temperature sensors. If the Pt100 is connected the transmitter makes automatic temperature compensation (pH only).
- pH range: 0 ÷ 14.00 pH
- ORP range: 0 ÷ 1000 / 0 ÷ -1000 / -1000 ÷1000 / 0 ÷ 2000 / 0 ÷ -2000 mV
- Temperature range: -10.0 ÷ 110.0 °C / 14.0 ÷ 230.0 °F
- Resolution: 0.01 pH, 1 mV, 0.1 °C
- Digital output: RS-485 isolated
- Analog output: 4-20 mA galvanically isolated, "current loop" two wires
- Power supply: 9 / 36 Vdc
- Dimensions: 71x95x58 mm. Rail Din (4 modules)
- Operating temperature: 0…+50 °
- EMC/RFI conformity: EN 61326
pH electrode sensors (glass, epoxy body and submersible)
Phase voltage controller PKF-302. The device is designed for electric motor protection from asymmetric supply and grid voltage drop. The controller has two switch outputs of which one is used for protective shutdown and another for alarm. Simplified type 333 variant.
- Channels: Shutdown and alarm
- Supply: 3x (50...230...265)V. Max 2,5W
- Frequency: 40...50...60 Hz
- Indicator: 3 x LED 3 digits
- Measuring mode: True RMS
- Activation voltage: 185 V
- Reset voltage: 195 V
- Activation time: about 1s
- Reset time: 1...999 s (optional 4 or 6 s)
- Switch outputs: 2 x switching 2A, 250V AC
- Ambient temperature: -15°C...55°C
- Mounting: 35 mm rail
- Protection class: panel IP40; connections IP20