This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Поиск

Критерии поиска

Товары, соответствующие критериям поиска

Показать:
Сортировка:

LTM potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

Movement of up to 1000 mm. High resolution (0,01 mm). No additional parts such as gears are needed, because transducer construction enables the direct connection into mechanical system.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines

LTP potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

The main difference from LTM transducers is that LTP has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines
  • Transducer for AC current and voltage into DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • Transducer for DC current and voltage into other DC signal (2 outputs)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • Signal transducer P20Z is designed to convert AC current and voltage (without direct component) into DC voltage or current signal
  • Input is isolated from input and supply
  • Has fixed inputs and outputs – non-programmable
  • Suitable for thick and viscous media
  • Different materials for optimum media compatibility
  • EMC protection class is IEC 61000 (lightning, electrical discharge)
  • Range: 0...0,1 bar to 0...6 bar
  • Accuracy: +/- 0.3 %
  • Output: 4...20 mA
  • Ambient temperature: -25°C...+70 °C
  • Process temperature: -25°C...+70 °C
  • Supply: 9...32 VDC
  • Protection class: IP68
  • Material: Stainless steel (1.4404 (316L) / 1.4462 (318LN))
  • Sensor technology: Thick film on ceramic
  • Sensor material: Ceramics, Al2O3 96%
  • Cable insulation: PUR / Radox / PE
  • Pressure transmitter for shipbuilding, engine manufacturing
  • Measured pressure from 0...1 bar to 0...250 bar
  • Technology: thick film on ceramic
  • Output signal: 4...20 mA
  • Accuracy: 0,5 %
  • Operating temperature: -25...+125 °C
  • Ambient temperature: -25...+125 °C
  • Conformity: DNV, GL, KRS, RINA
  • Protection class: min. IP68
  • Pressure transmitter for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measured pressure from 0...2,5 bar to 0...250 bar
  • Technology: thick film on steel
  • Output signal: 4...20 mA
  • Accuracy: 0,5 %, 0,3 %
  • Operating temperature: -40...+100 °C
  • Ambient temperature: -40...+100 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS

Power network transducer P41 is designed to convert 1-phase power network parameters into analog or digital signal. Measured parameters: voltage (U), current (I), frequency (f), active power (P), reactive power (Q), apparent power (S), power factor (PF), reactive power coefficient (tgφ), phase angle difference (φ), active energy (Ep), reactive energy (Eq).

  • universal inputs (1 A or 5 A, 100 V or 400 V)
  • programmable analog output ( -20 mA...+20 mA)
  • parameter transfer via RS-485 interface (Modbus RTU protocol)
  • chosen values memory (9000 records)
  • programmable current and voltage transformer coefficients
  • transducer settings are changed via „LPConfig“ software (USB)

Power network transducer P43 is designed to measure 3-phase (three or four-wire systems) power network parameters. Two parameter values are converted into analog output signal -20...+20 mA. Other parameter values are sent over RS-485 or USB ports. All parameter min and max values are measured. Data refresh interval is less than 1 s. Output signals are isolated from input and supply. Two programmable alarm outputs. Pulse (passive) output OC can be used for energy accounting. Mounted on 35 mm rail.

  • Measuring ranges:
    • current 1/5 A L1...L3: 0,02...6 A
    • voltage L-N/L-L: 2,9...276/ 10...480 V
    • frequency: 45,00...66 Hz
    • active power: -1,65 kW...1,4 W...1,65 kW
    • reactive power: -1,65 kvar...1,4 var...1,65 kvar
    • apparent power: 1,4 VA...1,65 kVA
    • power factor: -1...0...1
    • active energy: 0...99 999 999,9 kWh
    • sum energy: 0...99 999 999,9 kvarh
  • Consumed power: ≤ 6 VA
  • Transformation coefficients: Ku = 1...4000, Ki = 1...10000
  • Supply: 85...253 VDC or AC 40...400 Hz
  • Ambient temperature: -10...23...+55 °C

Temperature and standard signal transducer P30U.

 

  • Programmable input
  • Mathematical functions
  • Individual channel characteristic
  • 1 or 2 outputs
  • Variant with internal transducer 24 VDC power supply
  • RS-485 interface
  • Adjustable dimension
  • Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
  • Transducer programming with buttons or via PC (“LPConfig” software)
  • Temperature transducer TJ-DIN AV, designed to convert temperature measurement signal into 4...20 mA, 0...10 V
  • Mounted on 35 mm DIN rail
  • Measures air temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...+80 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...105 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • External sensor cable length: 1 / 2 / 4 m
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...125 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Current (AC / DC) transducer T23CT with 4...20 mA output
  • AC/DC current input (single option): up to 50 / 100 / 150 / 200 / 300 A
  • Optional mounting on DIN rail
  • Galvanic isolation
  • Supply: 24 VDC
  • Ambient temperature: -25...+55 °C
  • Protection class: IP65, IP40 for terminals

DPC 8380 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.

DPS 8381 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.

  • Range: 0...2,5 iki 0...600 bar / 0...30 iki 0...7500 psi
  • Sensor type: Thick film on steel
  • Accuracy:  ±0,5 %
  • Output (chosen): 4...20 mA / 0...5 VDC / 0...10 VDC / 1...6 VDC
  • Switching outputs: 2 x PNP
  • Shown measuring units: bar, psi, MPa, kPa, m WC, mm WC
  • Ambient temperature: -25...+85 °C
  • Media temperature: -25...+85 °C
  • Protection class: IP65
  • Process connection: G1/4" m, R1/4" m, 1/4"NPT m, 1/2"NPT m
  • Data logger memory: 3518 points