- Прибор предназначен для преобразования и галванического разделения стандартных сигналов постоянного тока и напряжения и установления индивидуальной характерисики выходного сигнала.
- Вход гальванически изолирован от выхода и источника питания.
- Программирование прибора выполняется с помощью программатора PD14 и бесплатной программой LPConfig.
TSV202-60 ideal for monitoring battery banks, solar panels, industrial control circuits, and other high-voltage applications.
- Dual channel input: 0…60 V
- Communication interface: 1-Wire protocol
- Accuracy: ±1%
- Resolution: 0.001V
- Galvanic isolation between the voltage circuit and 1-Wire bus
- Operating environment: -20…+60 °C / 10…90 %RH
- Warranty: 3 years
- Dual channel input: 0…24 mA or 0…10 V
- Communication interface: 1-Wire protocol
- Accuracy: ±1 %
- Resolution: 0.001mA / 0.001 V
- Galvanic isolation between the current circuit and 1-Wire bus
- Detection of special states such as sensor errors or calibration values
- Operating environment: -20…+60 °C / 10…90 %RH
- Warranty: 3 years
- 1-Wire protocol current transmitter
- Current measurement range: 0,3...15 A (AC / DC, set by jumper)
- Resolution: 10 bits
- Galvanic isolation between the current circuit and 1-Wire bus
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
- Input: Pt100 (2-, 3-, 4-wire)
- Measurement range: -200...+850 °C
- Resolution: 24 bits
- Very low current consumption
- No external power supply needed
- Warranty: 3 years
- Connection: RJ-11
- Input: 2x thermocouples - J, K, T, N, E, B, R, and S
- Output: Modbus RTU – RS-485
- Resolution: 24 bits with DSP processing
- Working isolation voltage: 1500 Vrms
- Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
- DIN rail mounting
- Power supply: 5…30 Vdc
- Warranty: 3 years
- Input voltage range: 0…264 Vac or 0…370 Vdc
- Input frequency: 0…60 Hz
- Input resistance: >2.4 MOhm
- Output: Modbus RTU – RS-485
- Resolution: 24 bits with DSP processing
- True RMS measurement
- Working isolation voltage: 1500 Vrms
- Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
- DIN rail mounting
- Power supply: 5…28 Vdc
- Warranty: 3 years
- Temperature measurement range: -30...+80 °C
- Humidity measurement range: 0...100 %
- Output: RS-485 Modbus RTU
- Calculates absolute humidity and dew-point temperature
- Cable length: 2 m / 2 m with M8 connector / 5 m / 10 m
- Operating temperature: -20...+60 °C
- Supply: 9...28 VAC/VDC
Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.
- Carbon dioxide (CO2) range: 400...2000 ppm
- Humidity range: 0...100 %
- Temperature range: 0...50 °C
Temperature transducers P4141, P4121, P4151, P4131, P4161, P4171, P4191 with 4...20 mA output and Pt1000 input.
P4121 – P4171 class transducers are designed to convert RTD Pt1000 (3850ppm/°C) signal to current. These transducers have 4...20 mA output. RTD sensor Pt1000 is not included.
- Pressure range: from 0...1 to 0...16 bar
- Output signal: 4 ... 20 mA (P1–P2)
- Process temperature: -25...+125 °C
- Process connection: G1/4" f
- Protection class: min. IP65
Duct temperature transducer with 4...20 mA output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Calibration certificate is included.
Duct temperature transducer with 0...10 V output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Output temperature range is user adjustable. Calibration certificate is included.
- Temperature measurement range: -35…+80 ºC
- Humidity measurement range: 0…100 % RH
- Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
- Output: Modbus RTU
- Allowed overpressure/ bellow: ± 50 kPa
- Operating temperature: 24 VAC / 15…35 VDC
- Protection class: IP 65
- Hydrogen pressure transmitter’s measuring principle: Thin-film-on-steel
- EC79 and ECER-134 certification pending (see product website for current situation)
- Applications: Fuel cells, fueling stations, hydrogen compressors, hydrogen tanks, vehicles with H drive
- Measuring range: 0…1050 bar / 0…15000 psi *(see product datasheet)
- Measuring accuracy at 25 °C typ.: ± 0.3 / 0.5 % FS typ.
- Output signal: 4...20 mA, 0.5...4.5 VDC, 0...5 VDC, 1...5 VDC, 1...6 VDC, 0...10 VDC, 0.1...10.1 VDC, 0.5...4.5 VDC ratiometric, Switching output: 1 or 2 PNP
- Pressure connections: G1/4" m, 1/4"NPT m, 7/16"-20UNF SAE4 m
- Ambient temperature: 40°C…+85°C
- Industrial pressure transmitter’s measuring principle: Thin-film-on-steel
- Applications: hydraulics, industrial applications, machine tools
- 5-fold overpressure resistance
- Measuring range: 0...2.5 / 0...700 bar // 0...30 / 0...10000 psi
- Measuring accuracy at 25 °C typ.: ± 0.5 % FS typ. ± 0.3 % FS typ
- Output signal: 4...20 mA, 0...5 VDC, 0.5...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
- Ambient temperature: -40°C…+125°C
- Incremental encoder output: A, B / A, B, Z / A, /A, B, /B / A, B, Z, /A, /B, /Z
- Resolution: 5 / 10 / 25 / 50 μm
- Magnetic measurement (contactless, non-friction system)
- Vibration-resistant
- Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
- Supply: 10...30 VDC / 5 VDC
- Operating temperature: -25...+85 °C
- Protection class: IP67
- Incremental encoder output: A, B / A, B, Z / A, /A, B, /B / A, B, Z, /A, /B, /Z
- Resolution: 5 / 10 / 25 / 50 μm
- Portable reference point
- Stroke values up to 2000 mm
- Vibration-resistant
- Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
- Supply: 10...30 VDC / 5 VDC
- Operating temperature: -25...+85 °C
- Protection class: IP65
- Measuring range: -1…100 bar (see datasheet)
- Basic accuracy 0,5% of range
- Output: 4…20 mA
- Process connection: G 1/2“, G 1/2“, G 1/2“ Flush membrane, G 1/4“, G 1/4“, 1/2“ NPT, 1/4“ NPT, Tri-Clamp (Ø 50,5) Flush membrane
- Operating temperature: -20…+85 / 200 °C (see datasheet)
- Stainless steel housing and diaphragm material
- Protection class: IP67 / IP68
- Pressure range: from 0...0,1 to 0...40 bar
- Output signal: 4...20 mA / 0...5 VDC / 1...6 VDC / 0...10 VDC / 0,5...4,5 VDC
- Process temperature: -25...+125 °C
- Process connection: G1/4" f, G1/4" m, G1/2" m DIN3852-A, G1/2" m DIN3852-E, 1/4"NPT m ANSI B1.20.1, 1/8"NPT m ANSI B1.20.1, 7/16"-20UNF m SAE4, R1/4" m DIN3858, G3/4" frontal membrane
- Applications: Machine tools, hydraulics, water treatment
- Protection class: IP65, IP67, IP68
- Pressure range: from 0...6 to 0...600 bar
- Output signal: 4...20 mA / 1 x PNP / 2 x PNP
- Process temperature: -40...+125 °C
- Accuracy: 0,3 %
- Dielectric strength: 710 V
- Measurement principle: thin film on steel
- Protection class: IP65, IP67
- Conformity: EN 50155, EN 45545-2, EN 61373, EN 50121-3-2
- Parametrization by SMI programmer (not included) via Bluetooth connection from smartphone (Android)
- Measuring function: differential pressure, volume flow
- Measuring ranges: multi-range switching with 8 switchable measuring ranges
- Output: switchable 0-10 V/ 4 ... 20 mA (via DIP switches)
- Allowed overpressure: 50 kPA
- Supply: 24 VAC
- Medium: clear air, non-aggressive, non-combustible gases
- Protection class: IP 54
- Signal splitter DAT5022
- Configurable with switches on body
- 3-way galvanic isolation (2000 VAC)
- Input: 4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V
- Output: 2 X (4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V)
- Power Supply: 18...32 VDC. Reverse polarity protection 60 VDC
- Current Consumption: Current output 35 mA max. Voltage output 25 mA max.
- Environment: -20...+70 °C / (non-condensing) 0-90%
- Housing: Self-extinguishing material
- EMC
- Immunity: EN 61000-6-2
- Emission: EN 61000-6-4
- Patented quality product (immersion sensor patent)
- Measuring ranges: multi-range switching with 8 switchable measuring ranges
- Output: 0 – 10 V or 4...20 mA
- Sleeve length: 50, 100, 150, 200, 250, 300, 400 mm
- Supply 24 VAC/ VDC – U var. or 15...36 VDC I var.
- Medium: in liquid or gaseous media
- For aggressive media, stainless steel immersion sleeves must be used
- Ambient temperature: -30…+70 ºC
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-1 is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-4 is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-S is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Operates as a temperature switch (thermostat), transducer, data logger
- Accumulated temperature data is read using a mobile phone with NFC interface
- Parametrization via NFC interface
- Display and electrical connection are independently rotatable 335°/343°
- Temperature measurement range: -50...+150 °C
- Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
- Switch output: 2 x PNP
- Sensor: Pt1000 A
- Data logger memory: 3518 measurement points
- Measurement interval: 0,1...999,9 s
- Operating temperature: -25...+85 °C
- Supply: 15...30 VDC
- Input: RTD: Pt100 (3-wire), TC: J, K N
- Output: IO-Link
- Configuration: via IO-Link
- Operating temperature: -20...+80 °C
- Supply 24 VDC
Temperature transducer with 0...10 V output is built in a durable watertight case. Built-in precise temperature sensor. Output temperature range is user adjustable. Calibration certificate is included.
Temperature transducer with 0...10 V output is built in a durable watertight case. To be used with an external Pt1000 temperature probe. Output temperature range is user adjustable. Calibration certificate is included.
- Input: RTD: Pt100 (3-wire), TC: J, K N
- Output: IO-Link
- Configuration: via IO-Link
- Operating temperature: -20...+80 °C
- Supply 24 VDC
Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.
- Transducer for DC current and voltage into other DC signal (1 output)
- Input, output and supply of the transducer are galvanic insolated
- Solves grounding problem in meshed signal networks
- User selectable type and range of input
- Up to 10 / 15 m level measurement with automatic temperature compensation
- Calculation of filling in the tank or flow in open channels
- Galvanically isolated 0/4...20 mA analog output
- Digital RS-485 Modbus RTU interface
- 2 alarm outputs
- Internal data and setup memory
- Two 32-points individual characteristics (for recalculation)
- LCD screen
- Housing protection grade: IP66
- Sensor protection grade: IP66 / IP 68
- Supply: 12...25...40 VDC
- Operating temperature: -20...23...55 °C
- Up to 10 / 15 m level measurement
- Analog output: 4…20 mA
- Digital output: RS-485 Modbus RTU
- Resolution: 3 mm
- Supply: 24 VDC / 300 mA
- Operating temperature: -20...60 °C
- Cable length: 1 m
- CO2 concentration measurement range: 0...10 000 ppm
- Output: 4...20 mA
- Programmable
- External probe cable length: 1 / 2 / 4 m
- LCD display
- Calibration certificate included
- Ambient temperature: -30...+80 °C
- Supply: 9...30 VDC
- Protection class: IP65
- Warranty: 3 years
Temperature and air humidity transducer P19 with RS-485 output, designed for room humidity ant temperature contro. Can be used in various control and monitoring systems. Output signal is digital (RS-485, MODBUS). Transducer parameters are programmed via PC. Wall-mounted. Can work in condensation-free environment.
- Integrated temperature and humidity sensor
- Calculated values – dew point temperature, absolute humidity
- Minimal and maximal value memory
- Isolated RS-485 port
Relative humidity and temperature transducer P18D with display and RS-485 output, designed for temperature and humidity measurement.
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitters with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…80 °C
- Operating temperature: -40…80 °C
- The sensor can be distanced, meaning the TJ-O can be equipped with the following external temperature sensors: TJ-1, TJ-2, TJ-4, TJ-S
- Sensor tube:
- Material: Stainless steel AISI304 (1.4301)
- Diameter: Ø6 mm
- Length: 25 mm
- Mounting box:
- Material: Polystyrene
- Dimentions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
Linear encoder MLS210. With spiral connection.
Technical specifications
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS110. With cable connection.
Technical specifications
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS110. With spiral connection.
Technical specifications
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS120.
Technical specifications
- Casing integrated into slider
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS130. Very small size.
Technical specifications
- Very small measuring head (in metal enclosure)
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS210. With spiral connection and slider joints.
Technical specifications
- Protection class IP67
- Twin sliders
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
- 4 analog inputs (standard signals, RTD, thermocouple)
- RS-485 Modbus output (Slave mode)
- 2 alarm outputs
- Galvanic isolation of inputs (2 from other 2)
- Programmable individual characteristics, mathematical functions
- Programmable time counters
- Rail-mounted
- Ambient temperature and humidity transducer with 4...20 mA output
- Stem length 700 mm
- Calculated values: dew point temperature, absolute humidity, specific humidity, mixing ration, specific enthalpy
- Display with two periodically changed shown values (can be switched off)
- Integrated sensors
- Calibration certificate is included
- Programmable output
- Low temperature inertia
- For use in non-aggressive environment
- 3 year warranty
LTC potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.
The main difference from LTM transducers is that LTC has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.
Application:
- Press Brake Machines
- Marble Machines
- Tension Control
- Horizontal Band Saw Machines
- Transfer Machines
- Hydraulic Machines
- Sheet Metal Working Machines
- Bending Presses
- Textile Machines