This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Поиск

Критерии поиска

Товары, соответствующие критериям поиска

Показать:
Сортировка:
  • Прибор предназначен для преобразования и галванического разделения стандартных сигналов постоянного тока и напряжения и установления индивидуальной характерисики выходного сигнала.
  • Вход гальванически изолирован от выхода и источника питания.
  • Программирование прибора выполняется с помощью программатора PD14 и бесплатной программой LPConfig.

TSV202-60 ideal for monitoring battery banks, solar panels, industrial control circuits, and other high-voltage applications.

  • Dual channel input: 0…60 V
  • Communication interface: 1-Wire protocol
  • Accuracy: ±1%
  • Resolution: 0.001V
  • Galvanic isolation between the voltage circuit and 1-Wire bus
  • Operating environment: -20…+60 °C / 10…90 %RH
  • Warranty: 3 years
  • Dual channel input: 0…24 mA or 0…10 V
  • Communication interface: 1-Wire protocol
  • Accuracy: ±1 %
  • Resolution: 0.001mA / 0.001 V
  • Galvanic isolation between the current circuit and 1-Wire bus
  • Detection of special states such as sensor errors or calibration values
  • Operating environment: -20…+60 °C / 10…90 %RH
  • Warranty: 3 years
  • 1-Wire protocol current transmitter
  • Current measurement range: 0,3...15 A (AC / DC, set by jumper)
  • Resolution: 10 bits
  • Galvanic isolation between the current circuit and 1-Wire bus
  • Excellent long-term stability
  • Warranty: 3 years
  • Connection: RJ-11
  • Input: Pt100 (2-, 3-, 4-wire)
  • Measurement range: -200...+850 °C
  • Resolution: 24 bits
  • Very low current consumption
  • No external power supply needed
  • Warranty: 3 years
  • Connection: RJ-11
  • Input: 2x thermocouples - J, K, T, N, E, B, R, and S
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…30 Vdc
  • Warranty: 3 years
  • Input voltage range: 0…264 Vac or 0…370 Vdc
  • Input frequency: 0…60 Hz
  • Input resistance: >2.4 MOhm
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • True RMS measurement
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…28 Vdc
  • Warranty: 3 years
  • Temperature measurement range: -30...+80 °C
  • Humidity measurement range: 0...100 %
  • Output: RS-485 Modbus RTU
  • Calculates absolute humidity and dew-point temperature
  • Cable length: 2 m / 2 m with M8 connector / 5 m / 10 m
  • Operating temperature: -20...+60 °C
  • Supply: 9...28 VAC/VDC

Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.

  • Carbon dioxide (CO2) range: 400...2000 ppm
  • Humidity range: 0...100 % 
  • Temperature range: 0...50 °C

Temperature transducers P4141, P4121, P4151, P4131, P4161, P4171, P4191 with 4...20 mA output and Pt1000 input.

P4121 – P4171 class transducers are designed to convert RTD Pt1000 (3850ppm/°C) signal to current. These transducers have 4...20 mA output. RTD sensor Pt1000 is not included.

  • Pressure range: from 0...1 to 0...16 bar
  • Output signal: 4 ... 20 mA (P1–P2)
  • Process temperature: -25...+125 °C
  • Process connection: G1/4" f
  • Protection class: min. IP65

Duct temperature transducer with 4...20 mA output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Calibration certificate is included.

Duct temperature transducer with 0...10 V output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Output temperature range is user adjustable. Calibration certificate is included.

  • Temperature measurement range: -35…+80 ºC
  • Humidity measurement range: 0…100 % RH
  • Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
  • Output: Modbus RTU
  • Allowed overpressure/ bellow: ± 50 kPa
  • Operating temperature: 24 VAC / 15…35 VDC
  • Protection class: IP 65
  • Hydrogen pressure transmitter’s measuring principle: Thin-film-on-steel
  • EC79 and ECER-134 certification pending (see product website for current situation)
  • Applications: Fuel cells, fueling stations, hydrogen compressors, hydrogen tanks, vehicles with H drive
  • Measuring range: 0…1050 bar / 0…15000 psi *(see product datasheet)
  • Measuring accuracy at 25 °C typ.: ± 0.3 / 0.5 % FS typ.
  • Output signal: 4...20 mA, 0.5...4.5 VDC, 0...5 VDC, 1...5 VDC, 1...6 VDC, 0...10 VDC, 0.1...10.1 VDC, 0.5...4.5 VDC ratiometric, Switching output: 1 or 2 PNP
  • Pressure connections: G1/4" m, 1/4"NPT m, 7/16"-20UNF SAE4 m
  • Ambient temperature: 40°C…+85°C
  • Industrial pressure transmitter’s measuring principle: Thin-film-on-steel
  • Applications: hydraulics, industrial applications, machine tools
  • 5-fold overpressure resistance
  • Measuring range: 0...2.5 / 0...700 bar // 0...30 / 0...10000 psi
  • Measuring accuracy at 25 °C typ.: ± 0.5 % FS typ. ± 0.3 % FS typ
  • Output signal: 4...20 mA, 0...5 VDC, 0.5...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
  • Ambient temperature: -40°C…+125°C
  • Incremental encoder output: A, B   /   A, B, Z   /   A, /A, B, /B   /   A, B, Z, /A, /B, /Z
  • Resolution: 5 / 10 / 25 / 50 μm
  • Magnetic measurement (contactless, non-friction system)
  • Vibration-resistant
  • Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
  • Supply: 10...30 VDC / 5 VDC
  • Operating temperature: -25...+85 °C
  • Protection class: IP67
  • Incremental encoder output: A, B   /   A, B, Z   /   A, /A, B, /B   /   A, B, Z, /A, /B, /Z
  • Resolution: 5 / 10 / 25 / 50 μm
  • Portable reference point
  • Stroke values up to 2000 mm
  • Vibration-resistant
  • Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
  • Supply: 10...30 VDC / 5 VDC
  • Operating temperature: -25...+85 °C
  • Protection class: IP65
  • Measuring range: -1…100 bar (see datasheet)
  • Basic accuracy 0,5% of range
  • Output: 4…20 mA
  • Process connection: G 1/2“, G 1/2“, G 1/2“ Flush membrane, G 1/4“, G 1/4“, 1/2“ NPT, 1/4“ NPT, Tri-Clamp (Ø 50,5) Flush membrane
  • Operating temperature: -20…+85 / 200 °C (see datasheet)
  • Stainless steel housing and diaphragm material
  • Protection class: IP67 / IP68
  • Pressure range: from 0...0,1 to 0...40 bar
  • Output signal: 4...20 mA / 0...5 VDC / 1...6 VDC / 0...10 VDC / 0,5...4,5 VDC
  • Process temperature: -25...+125 °C
  • Process connection: G1/4" f, G1/4" m, G1/2" m DIN3852-A, G1/2" m DIN3852-E, 1/4"NPT m ANSI B1.20.1, 1/8"NPT m ANSI B1.20.1, 7/16"-20UNF m SAE4, R1/4" m DIN3858, G3/4" frontal membrane
  • Applications: Machine tools, hydraulics, water treatment
  • Protection class: IP65, IP67, IP68
  • Pressure range: from 0...6 to 0...600 bar
  • Output signal: 4...20 mA / 1 x PNP / 2 x PNP
  • Process temperature: -40...+125 °C
  • Accuracy: 0,3 %
  • Dielectric strength: 710 V
  • Measurement principle: thin film on steel
  • Protection class: IP65, IP67
  • Conformity: EN 50155, EN 45545-2, EN 61373, EN 50121-3-2
  • Parametrization by SMI programmer (not included) via Bluetooth connection from smartphone (Android)
  • Measuring function: differential pressure, volume flow
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: switchable 0-10 V/ 4 ... 20 mA (via DIP switches)
  • Allowed overpressure: 50 kPA
  • Supply: 24 VAC
  • Medium: clear air, non-aggressive, non-combustible gases
  • Protection class: IP 54
  • Signal splitter DAT5022
  • Configurable with switches on body
  • 3-way galvanic isolation (2000 VAC)
  • Input: 4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V
  • Output: 2 X (4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V)
  • Power Supply: 18...32 VDC. Reverse polarity protection 60 VDC
  • Current Consumption: Current output 35 mA max. Voltage output 25 mA max.
  • Environment: -20...+70 °C / (non-condensing) 0-90%
  • Housing: Self-extinguishing material
  • EMC
    • Immunity: EN 61000-6-2
    • Emission: EN 61000-6-4
  • Patented quality product (immersion sensor patent)
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: 0 – 10 V or 4...20 mA
  • Sleeve length: 50, 100, 150, 200, 250, 300, 400 mm
  • Supply 24 VAC/ VDC – U var. or 15...36 VDC I var.
  • Medium: in liquid or gaseous media
  • For aggressive media, stainless steel immersion sleeves must be used
  • Ambient temperature: -30…+70 ºC
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…180 °C (depends on probe)
  • Operating temperature (case with transmitter): -40…80 °C
  • The sensor TJ-1 is selected according to the individual order
  • Mounting box:
    • Material: Polystyrene
    • Dimensions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
  • A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
  • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…180 °C (depends on probe)
  • Operating temperature (case with transmitter): -40…80 °C
  • The sensor TJ-4 is selected according to the individual order
  • Mounting box:
  • Material: Polystyrene
  • Dimensions: 64,4x 88,4x 42,2mm
  • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…180 °C (depends on probe)
  • Operating temperature (case with transmitter): -40…80 °C
  • The sensor TJ-S is selected according to the individual order
  • Mounting box:
    • Material: Polystyrene
    • Dimensions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Operates as a temperature switch (thermostat), transducer, data logger
  • Accumulated temperature data is read using a mobile phone with NFC interface
  • Parametrization via NFC interface
  • Display and electrical connection are independently rotatable 335°/343°
  • Temperature measurement range: -50...+150 °C
  • Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
  • Switch output: 2 x PNP
  • Sensor: Pt1000 A
  • Data logger memory: 3518 measurement points
  • Measurement interval: 0,1...999,9 s
  • Operating temperature: -25...+85 °C
  • Supply: 15...30 VDC
  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC

Temperature transducer with 0...10 V output is built in a durable watertight case. Built-in precise temperature sensor. Output temperature range is user adjustable. Calibration certificate is included.

Temperature transducer with 0...10 V output is built in a durable watertight case. To be used with an external Pt1000 temperature probe. Output temperature range is user adjustable. Calibration certificate is included.

  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC

Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.

  • Transducer for DC current and voltage into other DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • Solves grounding problem in meshed signal networks
  • User selectable type and range of input
  • Up to 10 / 15 m level measurement with automatic temperature compensation
  • Calculation of filling in the tank or flow in open channels
  • Galvanically isolated 0/4...20 mA analog output
  • Digital RS-485 Modbus RTU interface
  • 2 alarm outputs
  • Internal data and setup memory
  • Two 32-points individual characteristics (for recalculation)
  • LCD screen
  • Housing protection grade: IP66
  • Sensor protection grade: IP66 / IP 68
  • Supply: 12...25...40 VDC
  • Operating temperature: -20...23...55 °C
  • Up to 10 / 15 m level measurement
  • Analog output: 4…20 mA
  • Digital output: RS-485 Modbus RTU
  • Resolution: 3 mm
  • Supply: 24 VDC / 300 mA
  • Operating temperature: -20...60 °C
  • Cable length: 1 m
  • CO2 concentration measurement range: 0...10 000 ppm
  • Output: 4...20 mA
  • Programmable
  • External probe cable length: 1 / 2 / 4 m
  • LCD display
  • Calibration certificate included
  • Ambient temperature: -30...+80 °C
  • Supply: 9...30 VDC
  • Protection class: IP65
  • Warranty: 3 years

Temperature and air humidity transducer P19 with RS-485 output, designed for room humidity ant temperature contro. Can be used in various control and monitoring systems. Output signal is digital (RS-485, MODBUS). Transducer parameters are programmed via PC. Wall-mounted. Can work in condensation-free environment.

 

  • Integrated temperature and humidity sensor
  • Calculated values – dew point temperature, absolute humidity
  • Minimal and maximal value memory
  • Isolated RS-485 port

Relative humidity and temperature transducer P18D with display and RS-485 output, designed for temperature and humidity measurement.

  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitters with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…80 °C
  • Operating temperature: -40…80 °C
  • The sensor can be distanced, meaning the TJ-O can be equipped with the following external temperature sensors: TJ-1, TJ-2, TJ-4, TJ-S
  • Sensor tube:
    • Material: Stainless steel AISI304 (1.4301)
    • Diameter: Ø6 mm
    • Length: 25 mm
  • Mounting box:
    • Material: Polystyrene
    • Dimentions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer

Linear encoder MLS210. With spiral connection.

 

Technical specifications

  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS110. With cable connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS110. With spiral connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS120.

Technical specifications

  • Casing integrated into slider
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS130. Very small size.

 

Technical specifications

  • Very small measuring head (in metal enclosure)
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS210. With spiral connection and slider joints.

 

Technical specifications

  • Protection class IP67
  • Twin sliders
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC
  • 4 analog inputs (standard signals, RTD, thermocouple)
  • RS-485 Modbus output (Slave mode)
  • 2 alarm outputs
  • Galvanic isolation of inputs (2 from other 2)
  • Programmable individual characteristics, mathematical functions
  • Programmable time counters
  • Rail-mounted
  • Ambient temperature and humidity transducer with 4...20 mA output
  • Stem length 700 mm
  • Calculated values: dew point temperature, absolute humidity, specific humidity, mixing ration, specific enthalpy
  • Display with two periodically changed shown values (can be switched off)
  • Integrated sensors
  • Calibration certificate is included
  • Programmable output
  • Low temperature inertia
  • For use in non-aggressive environment
  • 3 year warranty

LTC potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

The main difference from LTM transducers is that LTC has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines
Loading...