  • Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (in range: 0...100 m/s) and flow m3/h
  • Sheathed thermocouple K probe integrated, with connection cable length 1,5 m (option)
  • Introduced perpendicularly in the pipe
  • Particularly adapted for measurement in warm air, charged with particles and for high speed
  • Accuracy: Better than 1 % for an alignment in relation to the flow axis of the fluid of ± 10 °
  • Coefficient: 1,0015 ± 0,01
  • Max static pressure: 2 bar
  • Temperature of use: 0…600 °C (up to 1000 °C in option)
  • Adjustable start time delay: 0...16 s
  • Operating resistance: 0...100 kΩ
  • Mounting on DIN rail
  • Operating temperature: -10...50 °C
  • Supply: 117/230/400 VAC
  • Protection class: IP20
  • Three versions by sensitivity: NS (standard), AS (high), SR (adjustable)
  • Operating resistance: 5,6 kΩ (NS) 70 kΩ (AS) 0...100 kΩ (SR)
  • Mounting on DIN rail
  • Operating temperature: -10...50 °C
  • Supply: 117/230/400 VAC
  • Protection class: IP20

The enLink Status-VC transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • 0…20 mA, 0…10 V or resistance input
  • 12 bit resolution
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours
  • 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
  • Configuration via USB cable / downlink
  • Case IP40 protection (IP 67 on request)
  • Įėjimas: Pt100, Pt1000, 0…4000 Ω, TC (E, J, K, N, R, S), -75…310 mV, -10…10 V, -24…24 mA, potenciometras
  • Relinė išėjimas: 1 x NO kontaktas, apkrovos galia 6 A / 250 V AC; 6 A / 30 V DC
  • Skaitmeninis išėjimas: RS-485 / MODBUS RTU
  • Išorinio įrenginio maitinimas: 24 V DC / 24 mA
  • Matematinės funkcijos matavimo reikšmės konvertavimui
  • Dviejų eilučių LCD ekranas (1 eilutė – 6 skaitmenys, 2 eilutė – 5 skaitmenys)
  • Apsaugos klasė: priekio – IP65 / galo – IP10
  • Darbinė temperatūra: -20...23...60 °C
  • Maitinimas: 40…253 V AC / 20…300 V DC
  • Range: -250...2550 Pa
  • Maximal overpressure: 30 kPa
  • Accuracy: ±1,4 %
  • Pressure and air flow measurements from air diffusers and valves
  • Data can be uploaded on your computer for visualization and further analysis
  • Over 700 programmed valve types
  • Mediums: air and non-aggressive gases
  • Operating temperature: -10... +50 °C
  • Connection: ø 5 mm pressure hoses
  • Can be used with Pitot tube
  • 5 year warranty
  • Included: calibration certificate, 2 x 2 m PVC hoses

The Triton ULTRA is a multifunctional vape sensor capable of detecting e-cigarette vapor, marijuana smoke (THC), smoking, loitering, the number of people, gunshots, loud noise, and glass breakage.

  • Measured parameters: Temperature, humidity, PM1.0, PM2.5, PM10, TVOC, CO2, NO2, CO, HCHO, sound level
  • Customizable instant alarms based on the situation: Email notification, loud alarm, lights, *integration
  • Tamper protection: device vandalism, masking and covering
  • Real-time monitoring of student loitering via live video streaming
  • No license subscription required for use
  • The sensor independently performs all measurements and detections and sends alarms itself
  • *Integration capability with many third-party systems: TCP, HTTP, MQTT, RTSP
  • Event logging of alarms in the device
  • Communication: LAN, WiFi
  • Operating environment temperature / humidity: 0...44 °C / 0...90% RH (non-condensing)
  • Power supply: PoE+ (IEEE 802.3at Class 3 compliance). Ability to connect up to 4 devices in series
  • Measured parameters (with respective sensors):
    a) Temperature (Pt100 or thermocouple)
    b) Humidity
    c) Air quality
    d) Air velocity
    e) Airflow
    f) Tachometry
  • Two inputs for Pt100 temperature sensors (range -200...600 °C)
  • Up to 6 measurements simultaneously
  • Power supply: Lithium-Ion battery (up to 57 hours)
  • Calibration certificate, additional battery, transport case included
  • Operating temperature: 0...50 °C
  • Protection class: IP54

SIRO is an indoor air quality transmitter with a modern design. The transmitter is available with several optional air quality sensors. The modular device can be equipped with CO2 concentration and VOC (Volatile Organic Compounds) measurements or alternatively PM (Particulate Matter) measurement, and in addition, temperature and humidity measurements. SIRO-MOD series models use Modbus serial communication protocol.

  • Measuring elements:
    • CO2: Non-dispersive infrared (NDIR); 0...2000 ppm
    • VOC: Complementary Metal Oxide Semiconductor (CMOS); range: * - see datasheet
    • PM: Laser-based light scattering particle sensing
    • Temperature: Integrated to CMOS
    • Relative humidity: Thermoset polymer capacitive sensing element
  • Field configurable outputs for selected measurements; Configuration possible through MODBUS
  • Proportional output options including voltage (0–10 V, 0–5 V, 2–10 V) and optional current (4–20 mA); MODBUS
  • Offset feature enabling field calibration for each measurement parameter (CO2, VOC, PM, RH, T)
  • Optional LCD-display and buttons
  • Operating temperature: 0…50 °C
  • Protection standard: IP20

Infrared temperature meter KIRAY 100 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.

Infrared temperature meter KIRAY 200 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.

Noncontact infrared thermometer KIRAY 300 is designed to diagnose, inspect and check the surface temperature of measured objects. Up to 100 values can be stored in the internal memory.

The CH52-E four-camera multisensor features four independent sensors, providing expansive coverage from a single install point. Each sensor includes a 1 / 2.8” progressive CMOS image sensor, varifocal lens with 2.08x optical zoom, and 30 meters of IR range to provide clear and consistent image quality in any lighting condition. The CH52-E includes four onboard CV25S Ambarella processors to support advanced analytics like AI-powered search, Occupancy Trends, line crossing, loitering, and Person of Interest (POI) alerts. The CH52-E excels at covering hallway intersections and exterior corners of buildings, providing comprehensive visibility and eliminating blind spots while only requiring a single PoE++ cable.

  • 30 - 365 days (1TB - 8TB) of onboard storage
  • Redundant cloud backup and unlimited cloud-based archiving of footage
  • Sensor Resolution: 4 x 5MP (2688 x 1944)
  • Protection class / Impact rating: IP66 / IK10
  • Operating temperature: -40…+50 °C
  • Warranty: 10 Years
  • Certifications: FCC, ICES, CE, UKCA, RCM, VCCI, KCC, NOM, CB, NTRA, ICASA, UL/cUL/IEC 62368-1, FY2019 NDAA compliant
  • Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
  • Webserver
  • Functional Block programming software
  • LED signaling for Link/Act Ethernet, serial RX-TX, power supply
  • Configurable by the software DEV9K
  • Galvanic isolation on all the ways (1500 VAC)

 

  • Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
  • Webserver
  • Functional Block programming software
  • LED signaling for Link/Act Ethernet, serial RX-TX, power supply, digital inputs and digital outputs state
  • Configurable by the software DEV9K
  • Capable to connect the sensors to the analog inputs
  • Galvanic isolation on all the ways (1500 VAC)

The principle of operation of this instrument is based on a high frequency band, enabling a very accurate detection of the level of media with a small emitting angle.

  • Radar level transmitter TLR designed for accurate level measurement in liquids and solids
  • Reflection removal mode
  • High frequency band: 77-81 GHz
  • Measuring range: 10, 20, 30, 50 m
  • Measuring accuracy: 2 mm
  • Output signal: 4…20 mA, Modbus RS485, Hart protocol
  • Bluetooth app for programming and settings
  • Process temperature: -20…+200 °C*
  • Process connection: Threads G 1 ½, G 1 ½ / 2, G 2 and customized flanges for all models*
  • Process pressure: -1…+16 bar*
  • Protection class: IP67
  • Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (0...85 m/s) and flow m3/h
  • The Pitot tube S is more sensitive to alignment errors than the Pitot tube L.
  • Introduced perpendicularly in the pipe
  • Particularly adapted for measurement in warm air, charged with particles and for high speed
  • With integrated K type thermocouple
  • Accuracy: 1 %
  • Coefficient: 0,84 ± 0,01
  • Static pressure: Atmospheric
  • Temperature of use: 0…1000 °C

Tempmate-S1 data loggers are specially designed for temperature monitoring in any cold chain logistics. The automatically created PDF and CSV report, containing detailed information such as data curve, every single measurement as a table and statistical information.

29.89 €
Без НДС: 24.70 €

Single-use data logger for real-time measurement of temperature, humidity and light. GSM tracking and LTE 4G connectivity for smart logistics worldwide. Free usability of tempmate.®-Cloud for information viewing, reports generation and devices setup. Tempmate-GS2 have 3 models: T, TH and TE, for more information see datasheet.

  • Temperature measurement range*: -200…+100 °C
  • Relative humidity measurement range*: 0…100 %
  • Ambient light measurement range*: 0…10000 lx
  • Local storage capacity*: 24200 values for Temperature, Humidity and Light
  • Shelf-Life:
    • Lithium Battery devices: 12 months (possibility to charge)
    • Non-Lithium Battery devices: 6 months (possibility to charge)
  • External sensor*: PT100 (cable length: 1m, length of probe is 6cm length, 4 mm in diameter, sensor tip: stainless steel)
  • Log interval: User defined: 1 min. to 60 min. (10 min. as standard setting preconfigured)
  • Transmission Interval: User defined: 10 min. to 1440 min. (60 min. as standard setting preconfigured)
  • Recording Duration:
    • Lithium Battery: 90 days (with standard log interval of 10 min. and transmission interval of 240 min.)
    • Non Lithium Battery: 60 days (with standard log interval of 10 min. and transmission interval of 240 min.)
  • Certifications: CE, EN12830, EMC, RoHS, FCC
  • Connectivity: LTE 4G cat 1 with 2G Fallback
  • Report Generation: Readable in the Cloud and locally in the device through the USB 2.0 interface
  • Location: LBS - GSM Localization
  • Recommended Storage Temperature: -15…+25 °C
  • Temperature sensor AUREGIS TJ-H with hygienic – food process connection and M12x1 4 pin connector
  • Sensor type: RTD (Pt100, Pt1000), TC (K, J)
  • Accuracy: A or B
  • Measuring range: from -50°C to 400°C
  • Sensor tube:
    • Length: 100, 180, 200 mm
    • Diameter: Ø6/8/10 mm
    • Material: stainless steel
  • Process connection tread: G1/2
  • Transmitter output type: 4...20 mA, 4...20 +HART, 0-10 V, RS-485 other parameters acc. to requirement
  • Cable connector: M12x1 4 pin
  • Various sizes are available depending on customer requirements and drawings

Thermal printer C-56 (Hengstler, Germany).

  • Air velocity, airflow and temperature measurement
  • Air flow measurement with a cone
  • Automatic average
  • Display of minimum and maximum values, hold function
  • Adjustable auto shut-off
  • Detection of flow direction
  • Selection of units
  • Supplied with calibration certificate
  • Display of minimum and maximum values, hold function
  • Adjustable auto shut-off
  • Automatic average
  • Selection of units
  • Detection of flow direction (LV 110/LV 117)
  • Supplied with calibration certificate
  • Air flow measurement with a cone (LV 110/LV 117)
  • Input: infrared sensor (850 nm)
  • Output: 4...20 mA current loop with HART interface, 2x PNP or NPN
  • Measurement range: 0...10 kNTU
  • Measurement rate: 10 measurements per second
  • Display, LED indication
  • Operating temperature: -40...+75 °C
  • Protection class: IP65
  • Supply: 24...30 VDC

Traditional U-shaped with easily controlled zero point. For air and non-aggressive gasses.

  • Range: -500...500 Pa

Fluid manometer for air and non-aggressive gasses – high quality pressure meter for narrow temperature ranges.

  • Range: 0…10 kPa
  • Volumetric flow and air velocity meter with linear analogue output in control quality (0...10 V & 4...20 mA) and switch
  • Suitable for media temperatures up to 350°C
  • Measured value display by means of LCD and LED
  • Freely scalable measuring range m/s, m³/h, l/min
  • Sensitive and fast airflow detection up to 30 m/s
  • Exemplary areas of application: Measurement and control of air flows, building services, PLC, filter monitoring, extraction and extrusion systems, exhaust gases and test benches

Sensor SKU: 5905309601192 (IP30)

Sensor SKU: 5905309601482 (IP67)

Wireless 4…20 mA / 0…10 V analog signal data logger, sensor interface, BLE allows users to connect analog sensors to the cloud**. Device can be equipped with up to four analog interfaces / transducers (2 x 4…20 mA and 2 x 0…10 V). Transducer can be powered* either from the device’s battery or by an external power source.

You can use a free mobile application to configure the device and read the data from its memory. If you add Efento Gateway, you can build a remote monitoring system.

  • Communication: BLE (Bluetooth Low Energy)
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery (on request 1000 mAh rechargeable battery (USB 5V))
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • External transducers can be powered by the device's battery (max. 16V, 30 mA)
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -15…+70 °C / 0…99 %
  • Case IP30 protection (IP 67 on request)

Sensor SKU: 5905309600072 (IP30)

Sensor SKU: 5905309600607 (IP67)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud** platform or any other third party systems.

  • Wireless 4…20 mA / 0…10 V analog signal sensor interface, data logger, NB-IoT measures analog readings and can send data over NB-IoT
  • Device can be equipped with up to four analog interfaces / transducers (2 x 4…20 mA and 2 x 0…10 V)
  • Transducer can be powered* either from the device’s battery or by an external power source
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -35…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection (IP67 on request)

Wireless Aranet radation sensor is portable device for measuring levels of ionizing radiation (γ, β) and x-rays. This sensor ensures comprehensive ionizing radiation monitoring by measuring both the total dose and dose rate. Perfect for home use to ensure the safety of your family and yourself! Ideal for travelers, explorers, and individuals who are frequently near radiation sources.

  • Detected types of radiation: γ, β, x-rays
  • Ionizing radiation dose measurement range: 0…1000 µSv/h or 0…100 mrem/h
  • Measures radiation dose rate (µSv/h / mrem/h) and total dose (mSv / rem)
  • Dose accumulation time limit: 2 years
  • Bluetooth Low Energy connection with smartphone (Android or iOS) using Aranet Home mobile app
  • Supply: 2 x AA batteries
  • Battery lifetime (20 °C): up to 4 years (see datasheet)
  • Measuring intervals: 1, 2, 5, 10 min. (If the radiation threshold is surpassed, the device automatically switches to a 1-minute interval)
  • Audial ionizing radiation detection feature (pulse counter buzzer)
  • E-Ink display for longer battery life
  • Operating temperature: 0...+50 °C
  • Protection class: IP20
Wireless current sensor 4…20mA with PSU, TDSCT102, TDSCT202 Hовый

Measures analog signal of a 3rd party sensor. Provides 24 or 12 VDC power for a 3rd party sensor using the built-in power supply unit (PSU).

  • Sensor compatible with base stations: PRO, PRO Plus ir PRO Plus LTE
  • Current measurement range: 0...30 mA
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Operating temperature: -30...+80 °C
  • Power supply: 85…265 VAC
    • 1 x AA battery is for to notify user in case of external
  • Protection class: IP67

Measure the difference in air pressure between two points as needed in HVAC (air filter condition), building automation and Pharma. This device, belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • Pressure range: ± 500 Pa
  • Resolution: 0,02 Pa
  • Accuracy: ± (0.10 Pa + 3 % of reading)
  • Long term drift: 0,05 Pa / year
  • Response time: (99 %) <1 s
  • Calibrated for Air, N2
  • Gas compatibility: Air, N2, O2
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply: 1 x AA battery
  • Battery lifetime (20 °C): up to 10 years
  • Operating temperature: -40…60 °C
  • Protection class: IP65

LoRa-Log-Meter is a wireless data logging system based on LoRaWAN communication technology. It is designed to collect data from LoRaWAN devices such as sensors, interfaces, and meters that monitor environmental, technological and industrial process parameters and transmit data packets to a LoRaWAN gateway.

Collected data is processed and stored in the gateway, and can be accessed via a web browser.

 

  • Compatible with Synetica and others LoRaWAN devices: analog inputs (4–20 mA, 0–20 mA, 0–10 V), temperature sensors, pulse inputs (SO, NC/NO contacts) and others
  • Individual alarm notifications based on specific sensors or contacts
  • Alarm notifications via email and SMS
  • Logging and review of errors and communication issues
  • Remote access to the LoRa-Log-Meter system via 4G LTE, Wi-Fi, or LAN (Ethernet)
  • Dynamic data visualization in graph (curve) format via a web browser
  • Data export in CSV and PNG formats
  • Password-protected user interface
  • No subscription required for the gateway or sensors
  • Remote configuration of data transmission intervals for devices via a web browser
  • Communication range from sensor to gateway:
    • 15 km Outdoors (in plain sight)
    • 50–200 meters indoors or up to 7–8 walls*
  • LoRaWAN devices powered by: 2 × AA 3.6 V lithium batteries or 5 V USB power
  • Measurement object: concentration of particulate matter (PM) in the air PM1.0, PM2.5 or PM10
  • Measurement range: 0…1000 µg/m3
  • Resolution: 1 µg/m3
  • Accuracy: ± 10 %
  • Measured data is sent wirelessly to Aranet Pro base station* and if needed to Aranet cloud*
  • Signal line of sight range: up to 3 km
  • Data transmission interval: 1, 2, 5 or 10 minutes
  • Protection: IP42
  • Operating temperature and humidity: -10…+60 °C; 0…95 % RH
  • Power supply: 12…24 VDC
  • Pressure measurement range: 5...25000 μm
  • Operating temperature: -10...+50 °C
  • Overload: 610 bar
  • Two valve system
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases
  • CO2 concentration measurement range: 0...10 000 ppm
  • Output: 4...20 mA
  • Programmable
  • External probe cable length: 1 / 2 / 4 m
  • LCD display
  • Calibration certificate included
  • Ambient temperature: -30...+80 °C
  • Supply: 9...30 VDC
  • Protection class: IP65
  • Warranty: 3 years
  • Pressure measurement range: -1...60 bar
  • Pressure measurement accuracy: ± 0,5 % of full scale
  • Overload: 65 bar
  • Operating temperature: -20...+50 °C
  • Used with wireless manifold
  • 124 refrigerant gases
  • Sensor: Pt100 (3-wire) / TC: K (with display / without display)
  • Output: HART / sensor output
  • Measurement range: -50...+400 °C
  • Configuration: via HART
  • Operating temperature: -20...+80 °C / -30...+100 °C
  • Various connection options
  • Supply: 12...40 VDC (HART), CR2032 (for screen)
  • Protection class: IP65

Differential manometer MM for air and non-aggressive gasses, designed for pressure measurement in narrow ranges.

  • Range: -100…1500 Pa
  • Operating temperature: -40… +60°C

Capacitive level sensor Reka 2000 is designed to be submerged into liquids, made out of non-toxic polypropylene (PP)

  • Input (single option): Pt100, J, K, 0...20 mA, 4...20 mA, ±20 mA, 0...75 mV, 0...10 V, ±10 V, 0...150 mV, ±75 mV, V150 mV
  • Voltage measurement range: 0...75 mV; 0...150 mV; 0...10 V (DC)
  • Current measurement range: 0/4...20 mA; ±20 mA (DC)
  • Temperature measurement range: -50...400 °C (Pt100); -50...1200 °C (J) / -50...1370 °C (K)
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Auxiliary 24 VDC output to supply transducers
  • Display: 3-color LED, 5-digit
  • Temperature compensation
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
  • Protection class: IP65
  • Measurement range: -40...+150 °C, -1...60 bar
  • Temperature measurement accuracy: ± 1,3 °C
  • Pressure measurement accuracy: ±0,5 % of full scale
  • Operating temperature: -20...+50 °C
  • Overload: 65 bar
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases
  • Measurement range: -40...+150 °C, -1...60 bar
  • Temperature measurement accuracy: ± 1,3 °C
  • Pressure measurement accuracy: ±0,5 % of full scale
  • Operating temperature: -20...+50 °C
  • Overload: 65 bar
  • Two valve system
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases

♦ Positive, negative and differential pressure measurement
♦ Air speed measurement
♦ Automatic zero find function
♦ Measured value hold
♦ Minimal and maximal value detection
♦ Measurement unit option

Loading...