- Measurement range: -40...+150 °C
- Temperature measurement accuracy: ± 1,3 °C
- Operating temperature: -20...+50 °C
- Used with wireless manifold
- Cable of 2 m length
- 124 refrigerant gases
- Dual channel input: 0…24 mA or 0…10 V
- Communication interface: 1-Wire protocol
- Accuracy: ±1 %
- Resolution: 0.001mA / 0.001 V
- Galvanic isolation between the current circuit and 1-Wire bus
- Detection of special states such as sensor errors or calibration values
- Operating environment: -20…+60 °C / 10…90 %RH
- Warranty: 3 years
- Sturdy
- Hanging hook
- 3 'Y' ¼” 'MFL connectors including one with a Schrader valve
- Digital inputs: 2
- 1-Wire input (up to 8 sensors)
- RS-485 input (up to 8 sensors)
- Analog inputs: 4 (2 x 0...10 VDC, 2 x 0...10 VDC / 4...20 mA, WEB control)
- Relay outputs: 4 (NO/NC)
- Setup via USB or SMS
- Data logger for up to 52 000 records
- Webserver
- Periodical upload of data logger file to a remote HTTP server
- HTTP Post, HTTP API
- Communication: 4G-LTE, 3G-WCDMA
- SMS alarms (up to 5 numbers)
- E-mail alarms (up to 5 recipients), SMT with TLS support
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- 4G LTE supported frequency bands:
- B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/B19/B20/B25/B26/B28/ B66/B34/B38/B39/B40/B41
- 3G supported frequency bands:
- B1/B2/B4/B5/B6/B8/B19
- 2G supported frequency bands:
- B2/B3/B5/B8
- M2M communication protocols: MQTT, HTTP API (XML or JSON)
- Setup via WEB interface through the USB or remote setup with HTTP API or SMS commands
- Digital inputs: 2 “dry contacts”
- 1-Wire input (up to 4 sensors)
- Analog inputs: 2 (0...60 VDC)
- Relay outputs: 2 (NO/NC)
- E-mail alarms (up to 5 recipients), SMTP with TLS support
- SMS alarms (up to 5 recipients)
- GSM Geolocation (optional)
- Firmware update over the air (FOTA)
- Operating temperature: -20...+55 °C
- Supply: 10…28 VDC
- The Si-83 tank pump is perfect for residential A/C (up to 20 kW) and heating units (up to 40 kW)
- Max discharge head: 5,4 m
- Max pressure: 5,7 m
- Tank volume: 2 L
- Automatic turn on specific level in tank
- Overdraft level safety switch
- Stainless steel motor shaft
- Protection class: IP44
- Max condensate temperature: 55 °C
- Max condensate acidity: pH > 2,5 (Gas condensing boilers)
- Quick installation with mobile app
- Ethernet connection
- Analog outputs: 2 (0...20 mA / 4...20 mA / 0...24 mA / 0...5 V / 0...10 V)
- Digital outputs: 4 (PWM / ON/OFF)
- Relay outputs: 2 (NO/NC)
- Modbus TCP/IP support
- Webserver
- XML/JSON, HTTP API commands
- SNMP alarms (up to 5 recipients)
- Operating temperature: -10...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
Antenna radar level meter ARLM-54 designed for reliable level measurement of various liquids and pasty.
- Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
- Intelligent numerical signal processing with false reflection elimination
- Measuring range up to 8 m or up to 20 m
- Current output - 4...20 mA, HART communication
- Measurement independent of temperature and pressure of the atmosphere above the surface
- Possibility to measure even in aggressive vapors
- Operating temperature: -30…+70 °C
- Protection class: IP68
- Antenna radar level meter ARLM-70 "AMANDA" designed for reliable level measurement of various liquids
- Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
- FMCW antenna radar level gauge with a range of up to 20 m
- Teaching function to suppress false reflections
- Display of measured values on matrix OLED or LCD display
- Current output - 4...20 mA, HART communication
- Manual or remote adjustment
- Measurement independent of temperature and pressure of the atmosphere above the surface
- Possibility to measure even in aggressive vapours or vacuum
- Operating temperature: -30…+70 °C
The ATEX LB Series Drum Heater is engineered for safe and efficient heating in explosion-proof environments. Designed for drums in Zones 1, 2, 21, and 22, it delivers reliable performance with self-limiting heating technology. Ideal for maintaining low-temperature processes and frost protection, it features robust, anti-static PVC fabric and a user-friendly ATEX-certified junction box. Perfect for industries handling volatile chemicals or requiring stringent safety standards.
Technical Specifications
- Certification: CETS 23 ATEX 030 X; CETS 23 ATEX 031 U
- Zones: Suitable for Zones 1, 2, 21, and 22
- T-Class: T6, T5, T4, T3, T2, T1
- IP Rating: IP65 for dust and water resistance
- Operating Temperature: 65°C (energized) / 85°C (de-energized)
- Ambient Temperature: -20°C to +55°C
- Power Output: Self-limiting heating cable, adjustable to drum size
- Materials: Anti-static, water-repellent PVC fabric (B2 Flame Retardant)
- Connection Cable: 5m, 3G1.5mm² with ATEX-certified junction box
- Available Sizes: For 200/220L drums
- Applications: Frost protection, temperature maintenance, chemical processing
The high temperature base drum heater heats metal drums from the bottom, with a diameter of 555mm, compatible with all size metal drums up to 200 liters. It has a built-in thermostat ranging from 50 to 300°C and can be combined with a traditional drum heater for faster heating. It can be used to heat a variety of industrial liquids.
Technical description:
- Tubular heaters.
- 50mm. Rockwool isolation.
- 3-meter power cable.
- Thermostat: 50° to 300ºC.
- Weight: 15kg.
- Can easily be used in conjunction with other drum heaters or insulation jackets for faster heating.
- IP 54.
Ideal for heating up:
- Water.
- Oils and also diesel fuel.
- Resin.
- Vaseline.
- Wax, e.g. lanolin (wool wax or wool grease).
- Fats.
- Glue.
- Adhesives.
Moisture measuring of sand, minerals, clay, grain, foodstuffs, sawdust, ores, sewage sludge. During operation, the sensor requires nothing but a power supply and a display or a controller that can receive the measurement signal. The BMMS sensor is designed for applications in which no multi-part systems are to be used but still the highest precision is required. Due to the in-process calibration, all potential interference from the sensor installation is directly compensated for.
The VA702 is a Volt/mA/TC Calibrator, designed as a source and measurement tool. It measures or outputs a 0 to 24 mA DC current loop, 0 to 20 V DC voltage, and supports thermocouple temperature measurements (model dependent). Note: The calibrator cannot measure and source simultaneously.
- Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
- Storage temperature: -40℃ to 60℃
- Operating temperature: -10℃ to 50℃
- Operating altitude: Up to 2000 meters
- Temperature coefficient: ±0.01% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
- Relative humidity:
- 95% up to 30℃
- 75% up to 40℃
- 45% up to 50℃
- 35% up to 55℃
- Power requirements: 6 x AAA batteries
- Size: 204mm (L) x 99mm (W) x 46mm (H)
- Weight: 460g (including battery)
The VA700 Loop Calibrator is a versatile source and measurement tool. It is designed to measure or output a 0 to 24 mA DC current loop and 0 to 20 V DC voltage. The calibrator cannot measure and source simultaneously.
- Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
- Storage temperature: -40℃ to 60℃
- Operating temperature: -10℃ to 55℃
- Operating altitude: Up to 3000 meters
- Temperature coefficient: ±0.005% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
- Relative humidity:
- 95% up to 30℃
- 75% up to 40℃
- 45% up to 50℃
- 35% up to 55℃
- Shock: Random 2g, 5Hz to 500Hz
- Safety: 1 meter drop test
- Power requirements: 6 x AAA batteries
- Size: 204mm (L) x 99mm (W) x 46mm (H)
- Weight: 460g (including battery)
- The versatile Si 2052 is suitable for replacement of some market standards drain pumps used in cassette type air-conditioning units up to 20 kW
- Max discharge head: 0,9 m (flow rate = 24 l/h)
- The single level detection unit can be used as a safety contact (NC 50 VA resistive – 250 V) to cut off automatically the air conditioning system compressor or solenoid valve
- The centrifugal technology inside this pump is specifically designed for removing condensates continuously, in any kind of environment, with a very low sound level (≤ 30 dBA)
- Protection class: IPX4
- Operating conditions: 100 % - continuous duty
- Applications of flue gas analyzer Si-Ca 130: boilers, burners, water heaters and furnaces
- Detectable gases: O2, CO, CO(H2), CO2, NO, Low NO, NOx, Low NOx
- Up to three gas sensors
- CO measurement up to 8000 ppm
- Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation), stack gas velocity
- Color graphical touchscreen for control
- Communication: USB, Bluetooth (mobile App), remote printer
- Measurement storage: 2000 data points + smartphone and PC
- Predictive maintenance with estimated sensor life and calibration reminders
- Protection class: IP42
- Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
- Operating temperature: -5…+45 °C
- Sensor protection by pump stopping
- Range: from 0....60 to 0...5 kPa
- Accuracy: ±2% (FS 20°C)
- Allowed overpressure: 20 kPa
- Operating temperature: -5...+60°C
Differential manometer DPG/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.
- Range: 0…1500 Pa
- Switch activation range: 20…1500 Pa
- Operating temperature: -5… +60°C
Differential manometer MM/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.
- Range: 0…1500 Pa
- Switch activation range: 40…1500 Pa
- Operating temperature: -20… +60°C
- To measure air and neutral gases pressure in range -100...100 Pa
- Solenoid valve for auto-calibration: frequency 1…60 min
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -100...100 Pa
- Accuracy: ± 1 % of reading ± 2 Pa
- Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
- Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
- Response time: 0.3 s
- Output: 0-10 V and 4-20 mA
- Overpressure tolerated: 21 000 Pa
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply: 24 V AC / V DC
- To measure air and neutral gases pressure in range -1000...1000 Pa
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -1000...1000 Pa
- Accuracy: ± 1.5 % of reading ± 3 Pa
- Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
- Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
- Response time: 0.3 s
- Output (Optional): 0-10 V ir 4-20 mA: 4-20 mA
- Overpressure tolerated: 21 000 Pa
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
- To measure air and neutral gases pressure in range -2000...2000 mbar
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -2000...2000 mbar
- Accuracy: ± 1.5 % of reading ± 3 mbar
- Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
- Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
- Response time: 0.3 s
- Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
- Overpressure tolerated: 4100 mbar
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
- To measure air and neutral gases pressure in range -500...500 mbar
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -500...500 mbar
- Accuracy: ± 1.5 % of reading ± 3 mbar
- Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
- Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
- Response time: 0.3 s
- Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
- Overpressure tolerated: 1400 mbar
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
Duct temperature transducer with 4...20 mA output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Calibration certificate is included.
Gas cylinder heating jacket prevents frosting and ensures a constant flow rate for laboratory and industrial processes. Equipped with a digital thermostat, it is suitable for various gases and has a durable, lightweight design with quick-release buckles for easy attachment and transport.
- Digital thermostat with a heating range from 0 – 90ºC
- Durable, lightweight design with quick-release buckles
- Suitable for various gases, including SF6, Propane, Nitrogen, Oxygen, BCl3, WF6, and HF
- Silicone impregnated fabric
- Fiberglass insulation
- Teflon heating wire
- 3 meter power cable (no plug)
- Safety Thermostat
- IP40 Protection
The ATEX Gas Bottle Heater series is a safe, efficient, and customizable heating solution for gas bottles located in hazardous areas.
- Nominal voltage: 230 VAC*
- Nominal power: 380W, 850W, 850W (10L, 50L, 79L) or application-specific
- Max. operating temperature: +50/60°C (jacket max. 200°C)
- Temperature class: T6, T5, T4, T3 (depending on temperature setting limiter)
- Electrical connection terminal boxes for network (EX-e) / sensor (EX-i)
- Protection class: IP65/I
- Zones 1/2 (gas); 21/22 (dust)
- Sensors: 2xPt100 (EX-i, EX-e)
- Weight: 6kg, 9.5kg, 10kg (10L, 50L, 79L)
The silicone heater increases flow from LPG cylinders. By adding heat directly to the cylinder, the silicone heater maximizes LPG vaporization, ensuring that your supply lasts longer and works better, even under high demand.
Dimensions: 890mm x 120mm
Voltage: 230V
Wattage: 500W
Compatible with 22kg and 33kg standard size gas bottles
Spring mounted for perfect cylinder fit
Features a 40°C limiter and a 55°C safety fuse with manual reset
Utilizing unique dual-sensing technology, the device combines electromagnetic induction with an integrated ultrasonic sensor to provide highly accurate detection of both liquid level and flow velocity. Specifically optimized for partially filled pipes, open channels, and gravity-fed systems, the unit achieves an outstanding accuracy of ±1–2% of the actual flow rate.
- Internal pipe diameter: DN80…DN600
- Flow velocity (min. / max.): 0,46…7,5 m/s
- Accuracy: ± 1…2 % of actual flow (depends on flow profile and level detection)
- Process Temperature: 0…+70 °C
- Coating materials: hard rubber
- Maximum working pressure: No pressure (gravity flow) or 10 bar if pipe is full
- Output signal: 2× pulse / flow switch (max. 400 Hz), 4 ... 20 mA, 1× RS485 interface (Modbus / M-Bus protocol), M-Bus, HART, Ethernet module (TCP/IP, integrated web server)
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Data archiving on a micro-SD card
- Process connections: flange
- Maximum ambient temperature: 55 °C
- Power supply: 24 V AC / DC, 230 V AC
- Protection class: IP68 for sensor, IP65-IP68 for transmitter
FLOW 38 MID version with certification, allowing the flow meter to be used for utility metering. FLOW 38 MID is certified for use with drinking water. The FLOW 38 MID electromagnetic flow rate meter is a precise measuring device designed to measure the flow of electrically conductive liquids. The electronic unit (display) can be connected directly to the body (rotatable up to 350° for convenient viewing). Various process connection versions are available. A wide selection of materials for the internal surfaces in contact with the process medium allows the device to be adapted to various liquids.
- Internal pipe diameter: DN10…DN400
- Flow velocity (min./max.): 0,1…12 m/s (R40, R50)
- Accuracy: 0.2% in the 1:100 range, 0.5% in the 1:200 range
- Maximum medium temperature depending on the inner coating: 150 ℃
- Coating materials: rubber, teflon, ceramic
- Maximum working pressure: up to 16 bar
- Output signal: pulse, 4-20 mA, RS485 (Modbus RTU/ M-bus)
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Process connections: Flange, Thread
- Maximum ambient temperature: 50 °C
- Power supply: 24 VAC/VDC, 110... 230 VAC
- Protection class: IP65, IP67, IP68
The FLOW 38 electromagnetic, bidirectional flow and flow rate meter is a precise measuring device designed to measure the flow of electrically conductive liquids. Due to the wide range of configurations available, this device is used in many industries. The electronic unit (display) can be connected directly to the body (rotatable up to 350° for convenient viewing) or connected via a cable up to 30 meters long. Various process connection versions are available. A wide selection of materials for the internal surfaces in contact with the process medium allows the device to be adapted to various liquids. FLOW 38 is certified for use with drinking water. There is also a version of the Flow38 with MID certification, allowing the flow meter to be used for utility metering.
- Internal pipe diameter: DN4-DN600
- Flow velocity - bidirectional (min./max.): 0.2…12 m/s
- Accuracy: 0.2% in the 1:100 range, 0.5% in the 1:200 range
- Maximum medium temperature depending on the inner coating: 150 ℃
- Coating materials: rubber, Rilsan, Teflon, ceramic
- Maximum working pressure: up to 100 bar
- Output signal: pulse, 4-20 mA, RS485 (Modbus RTU/ M-bus), Modbus TCP/ IP, HART
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Process connections: Flange, Sandwich, Food grade fittings (clamp), Thread
- Maximum ambient temperature: 55 °C
- Power supply: 24 VAC/VDC, 110... 230 VAC
- Protection class: IP65, IP67, IP68
The FLOW45 electromagnetic flowmeter is equipped with a lithium battery, so it does not require an external power supply. The device has high accuracy in terms of full flow rate. Before each measurement, automatic diagnostics of all functions and parts necessary for proper measurement are performed. The device has a built-in empty pipe test and if there is no full flow, it will invalidate the entire measurement, as well as assess the flow direction and record the appropriate data.
- Internal pipe diameter: DN10…DN200
- Flow velocity (min. / max.), bidirectional: 0,2…12 m/s (1/60)
- Accuracy: 1 % for 1…10 m/s
- Maximum medium temperature depending on the inner coating: 150 ℃
- Coating materials: rubber (hard, soft, drinking water certified), Teflon, ceramic, Rilsan
- Maximum working pressure: up to 100 bar
- Output signal: pulse, RS485
- GSM data transmission module
- Data archiving on a micro SD card
- Process connections: flange, thread, sandwich, food grade
- Maximum ambient temperature: 5…55 °C
- Power supply: replaceable lithium battery (last up to 5 years) / external (12 V DC, max. 500 mA)
- Protection class: IP65, IP67, IP68
- Analog inputs: 6 (0...10 VDC / 4...20 mA, configurable, isolated)
- Digital inputs: 4 (isolated)
- RS-485 input (up to 24 Modbus RTU registers)
- Memory: 70 000 values
- Ethernet connection
- Modbus RTU to Modbus TCP conversion
- Webserver
- Periodical upload of data logger file to a remote HTTP server
- HTTP Post, HTTP API
- SNMP alarms (up to 5 recipients)
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.
- Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
- Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
- CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
- Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
- Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
- Air quality (VOC) measuring range: 0…100 %
- Data output: galvanically separated RS-485 Modbus RTU interface
- Variants: with / without LCD display
- One sensor covers about 30 m² of room area
- Power supply: 24 V ac/dc (200 mA)
- Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
- Flow monitor for liquid media in the range of 4…400 cm/s with analog (4…20 mA) and status output (PNP, NPN) for monitoring a flow threshold
- Ten LEDs indicate flow and contact closure
- Equipped with 2 control buttons for setting the switching point
- Available with 65 mm and 125 mm mounting depths
- Rugged design for industrial environments, IP67
- Applications of flue gas analyzer Si-Ca 130: for commercial and residential boilers and water heaters
- Detectable gases: O2, CO, CO2, NO, NOx
- Up to three gas sensors
- CO measurement up to 8000 ppm
- Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation)
- Color display screen with buttons
- Communication: Bluetooth (mobile App), remote printer
- Measurement storage: smartphone
- Predictive maintenance with estimated sensor life and calibration reminders
- Protection class: IP42
- Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
- Operating temperature: -5…+45 °C
- Sensor protection by pump stopping
Kuhlmann Ground Thawing Blankets are durable and weatherproof, designed to thaw frozen ground and soil, pipes, and protect equipment from freezing. They also work as curing blankets for various construction purposes.
Technical specifications:
- Durable PVC materials.
- Fixed temperature (70°C).
- 2-meter power cable.
- Special sizes produced upon request.
- IP67 Class.
- In normal conditions the mat thaws up to 30 cm of soil in 24 hours - or up to 60 cm in more sandy soil/ground.
- Digital inputs: 2
- 1-Wire input (up to 8 sensors)
- RS-485 input (up to 8 sensors)
- Analog inputs: 4 (2 x 0...10 VDC, 2 x 0...10 VDC / 4...20 mA, WEB control)
- Relay outputs: 4 (NO/NC)
- Setup via USB or SMS
- Data logger for up to 52 000 records
- Webserver
- Periodical upload of data logger file to a remote HTTP server
- HTTP Post, HTTP API
- SMS alarms (up to 5 numbers)
- E-mail alarms (up to 5 recipients), SMT with TLS support
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...24 VDC
- Enables the PC to be connected to HART interface, i.e. to configure a device
- Active operation: current loop is supplied
- Passive operation: used in an existing current loop
- Included HART-Tool software
- Supply: from USB
- Galvanic isolation between USB and HART
RFLS-53 can be used in demanding applications to indicate powder, dust and hygroscopic materials and can replace mechanical rotary level switches or standard capacitive level switches.
- The RFLS-53 uses the principle of high-frequency capacitive measurement
- It responds to the mass of the material and ignores deposits and material residues on the measuring part
- For demanding applications to indicate powder, dust and hygroscopic materials
- The sensor is available in several versions with different types of outputs and electrical connections
- The RFLS-53 fully replaces the older CLS-53, its electrical connection is different for the 230 VAC version (3 wires)
- Temperature measurement range:
a) Ambient model: -20...+80 °C
b) Remote model with polycarbonate probe: -20...+80 °C
c) Remote model with stainless steel probe: -40...180 °C - Relative humidity measurement range: 0...100 %
- Calculates dew point, absolute humidity, enthalpy and combination ratio
- 4-wire analog output: 0...5/10 V or 0/4...20 mA
- 2 relay outputs
- Versions with or without display
- Protection class: IP65 (ABS V0 housing)
HST comes in three models, HST-M – standard model (IP20), HST-D – remote sensor (IP65) and HST-A – channel model (IP65).
The Kuhlmann Electro-Heat IBC Immersion Heater is an efficient solution for heating liquids in Intermediate Bulk Containers (IBCs), addressing viscosity challenges to enhance industrial productivity. Suitable for a variety of substances, it ensures consistent heating and easy liquid management. Its applications span multiple industries, including chemical processing, pharmaceuticals, food and beverage, and oil and gas. Constructed with durable stainless steel and featuring precise temperature control, this immersion heater combines performance with longevity.
Technical Specifications:
- Surface load: 2.2 W/cm²
- Power: 2000W
- Supply: 230V 1-phase
- Stainless steel tube element AISI 316L (1.4404)
- Length of element: 950mm
- Diameter of element: ø100mm
- Heated zone: 300mm
- Integrated PT100 sensor
- Minimum level of liquid during heating: 500mm (half full)
- Cable between heater and control unit: ~2800mm
- Digital controller: 0-90°C
An IBC silicone base heater efficiently heats up contents in an IBC container, making it easy to discharge viscous or semi-solid products with minimal waste. The 2700W heater can heat water from 15°C to 70°C in less than 40 hours. Kuhlmann’s durable silicone base heater fits various IBC containers and is easy to install and use. It can also be mounted with a digital temperature controller for precise temperature control.
Technical Specifications:
- Dimensions: 1035 - 851mm.
- Materials: 100% silicone.
- 1,5 meter power cord with no plugs.
- 0-150°C PT100 Sensor System temperature controller (additional product).
- Heats water from 15°C - 70°C in less than 40 hours in a fully loaded IBC Container.
- Universal input for measuring temperature, resistance and standard signal
- 4 alarm outputs with signaling on LED diodes
- Digital output: RS-485 modbus (can be programmed through RS-485)
- Analog signal output: 0/4...20 mA or 0...10 V
- Two-line LCD display
- Mathematical functions for converting the measured value
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -25...23...55 °C
- Measurement of parameters: voltage, current, active, reactive and apparent power, cosφ, tgφ, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
- Current and voltage harmonics analysis up to 51st (measurements available via RS-485)
- Programmable input:
- Current: 0…1 / 0…5A
- Voltage: 0…100V / 0…230V / 0…400V
- Output:
- Analog: 0/4...20 mA or 0...10 V
- Relays: 1 or 4
- Binary (OC)
- Digital output: RS-485 modbus (can be programmed through RS-485)
- Two-line LCD display
- Pulse output to measure energy consumption
- 4 alarm outputs with signaling on LED diodes, working in 7 different modes
- Conversion of any measured value into an analog signal 0/4...20 mA or 0...10V
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -25...23...55 °C
- Voltage measurement ± 600 V, current measurement via shunt, power, energy and capacity measurement of d.c. circuits
- 4 alarm outputs with signaling on led diodes, working in 7 different modes
- Analog outputs: 0/4...20 mA or 0...10 V
- Digital output: RS-485 / MODBUS RTU
- Two-line LCD display
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -25...23...55 °C
The CM22 provides essential video security features in a compact form. It is a 3MP (2048x1536) camera with 10 meters of IR light range, and includes people and vehicle detection for motion search and trajectory analysis. The CM22 camera, combined with the SV23 vape detector and air quality sensor, and powered by the Verkada Command cloud computing platform, creates a powerful vape prevention and logging system.
- 30, 60 and 90 days of data retention (256…768 GB) on hardware and cloud back-up. If the connection to the Command cloud is lost, data is saved onboard and synced once the internet connection is restored
- Easy to install: no NVR, DVR, servers or port forwarding, just PoE connection
- Alerts: Camera status (offline), motion detection, people detection, vehicle detection, crowd detection, line-crossing detection, loitering detection
- Privacy: live face blur, privacy regions and audit log
- Field of view: Horizontal: 95°; Vertical: 69°; Diagonal: 130°
- Operating temperature / humidity: -10…50 °C / 0…90 %
- Connection and power input: RJ-45, PoE (IEEE 802.3af type 1)
- Certifications: FCC, ICES, RCM, VCCI, CE, UKCA, EN 50155 railway compliance, UL/cUL/IEC 62368-1, NOM
- Warranty: 5 years
- Applications of flue gas analyzer Si-Ca 230: boilers, burners, water heaters, gas and diesel engines, furnaces, industrial kilns, industrial heating systems, incinerators
- Detectable gases: O2, CO (H2 comp.), CO2, NO, Low NO, NO2, Low NO2, NOx, Low NOx, SO2, Low SO2, CxHy (HC), H2S
- Up to six gas sensors
- CO measurement up to 50 000 ppm
- Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation), stack gas velocity
- Color graphical touchscreen for control
- Communication: USB, Bluetooth (mobile App), remote printer
- Measurement storage: 2000 data points + smartphone and PC
- Predictive maintenance with estimated sensor life and calibration reminders
- Protection class: IP42
- Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
- Operating temperature: -5…+45 °C
- Sensor protection by pump stopping
Industrial IoT module TCW242 for remote real-time monitoring and control of industrial equipment, facilities, production lines, renewable energy systems, greenhouses and water stations
- Web-based configuration and control with password protection
- 4 digital inputs for dry contacts
- 4 analog inputs with 0-10V and 0-20mA options
- 4 relays with normally open/normally closed contacts
- RS-485 interface for MODBUS RTU sensors. Up to 24 sensors (registers)
- Monitor up to 24 channels
- Set up to 24 independent alarms
- SNMPv3 protocol support
- Alarm notifications via SNMP traps
- NTP protocol support
- HTTP API commands
- 4 schedules for real-time control of relay outputs
- Custom logical functions
- Secured email transfer with TLS 1.0, TLS 1.1, and TLS 1.2 support
- Data logging capacity for up to 70,000 records
- Dynamic DNS support for DynDNS, No-IP, and DNS-O-Matic providers
- Periodical HTTP / HTTPS Post of XML / JSON status files for client-server systems
- MODBUS TCP / IP protocol support
- MQTT 3.1.1 protocol support
- Rugged DIN-Rail / wall-mountable enclosure
- Operating temperature range: -20…+55 °C
The Internal IBC Heater is a unique approach to heating viscous foodstuffs and chemicals within IBC Containers. It is designed to protect sensitive products, such as syrups, honey, treacle, molasses, fats and other viscous products that are difficult to process. Most products can be batched within a relatively short time, increasing efficiency and reducing down time.
Technical specifications:
- Designed for insertion into 1000 litre cubic IBC but will also fit inside most IBC configurations.
- Adjustable temperature range from 0°C to 70°C using an easy to use controller on the top of the heater.
- 230/240 Volts - up to 2.4kW power output.
- Finned, food safe heating element that is inserted into the IBC, thereby heating the contents directly.
- Fast batching ability. Unique thermodynamic core that gives even temperature distribution along the heating extrusion,
- Preventing thermal damage to the liquid contents of the IBC.
- Non-stick industrial strength Xylon coating for easy washdown.
- Carefully designed low Watt density to protect sensitive products.
- Lightweight with stainless steel handles for easy insertion and extraction.
- Even temperature distribution along the length of the heating extrusion.
- Colored LED for power cycle and status indication.
- 16 Amp blue industrial power plug.
- Protective sleeve between the base of the control unit and the neck of the IBC to prevent ingress of contaminants.
- Robust Construction:
- IP67-rated body with potentiometer control mounted under protective see-through cover.
- The product is sealed to ensure that all the connections and components are waterproof.
- Robust IP67-rated aluminum case.
- Long life heating elements.



