  • Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
  • THD factor
  • Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
  • Digital output: RS-485 MODBUS (option)
  • Protection class for front side: IP65
  • Supply: 85...253 VDC/VAC
  • Backlit LCD display
  • Dimensions: 96 x 96 x 77 mm
  • Measurement of power network parameters in 1-phase and 3-phase (3 or 4-wire) systems
  • Current inputs 0,1 A and 0,25 A (for dedicated transformers)
  • Quick and convenient ways to connect current transformers via RJ12 connector or screw terminals
  • Designed for usage with following transformers: LJ12, LJ25, LJ35, LJ45, LJ306, LJ307, LJ308
  • RS-485 (MODBUS RTU) interface
  • THD factor measurement
  • Backlighted LCD 3,5”
  • Protection grade from the frontal side: IP65

Digital programmable indicator N20 for temperature, DC voltage and current measurement. Measures J, K, Pt100 temperature sensors’ signals.

 

Programmable parameters:

  • LED indicator color, which changes depending on input signal value: green, yellow and red
  • Value limits
  • Measurement unit indication
  • Cold junction compensation (CJC)
  • Compensation for Pt100 sensors
  • Averaging time
  • Individual characteristic
  • 2 OC alarms in 6 modes

Single-phase commutator – controller RP7. The device can be used or circuit commutations. Can be used for resistive and inductive loads and single-phase motor speed control. Possible control with standard analog signal.

 

Other functions:

  • Load current limiting
  • Soft start
  • Isolated inputs
  • Load current control
  • Fuse failure detection
  • Overload indication

Multifunctional professional current cramps NC12 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, frequency, temperature (with Pt100 and Pt1000 sensors), electric resistance and capacitance. Twistable clamp direction enables user to measure current in hard-reachable areas. Two variants are available: NC12-300A (up to 300 A AC) and NC12-1000A (up to 1000 A AC).

Multifunctional professional current cramps NC14 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, active, reactive, apparent power, inrush current, resistance, harmonics (up to 49th), phase angle, THD, power factor, DF, crest factor and power factor. Twistable clamp direction enables user to measure current in hard-reachable areas. Can be used in single- and three-phase (3 or 4 wire systems) networks. Two variants are available: NC14-400A (up to 400 A AC) and NC14-1000A (up to 1000 A AC).

  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures barometric pressure using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures carbon dioxide (CO2) using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Portable analyzer NP40 is designed for power network quality parameter analysis
  • Analyses voltage and current harmonics up to 51-st, THD
  • Real-time waveform display (4 voltage / 4 current)
  • Measurement of TRMS currents up to 3000 A (with standard sensor)
  • Half cycle RMS measurement (voltage and current)
  • Measurement in 1-phase and 3-phase systems (3- and 4-wire)
  • Voltage, current, harmonics, power, energy and other parameter measurement
  • Graphical representation of data in a waveform and vector diagram
  • Record of events: dips, swells, overvoltages
  • Built-in 8 GB memory card
  • Ethernet interface for remote monitoring
  • USB interface for data transfer
  • Color 5,6” TFT display, 320 x 240 px
  • Transducer for AC current and voltage into DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • Transducer for DC current and voltage into other DC signal (2 outputs)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • Signal transducer P20Z is designed to convert AC current and voltage (without direct component) into DC voltage or current signal
  • Input is isolated from input and supply
  • Has fixed inputs and outputs – non-programmable

Temperature and standard signal transducer P30U.

 

  • Programmable input
  • Mathematical functions
  • Individual channel characteristic
  • 1 or 2 outputs
  • Variant with internal transducer 24 VDC power supply
  • RS-485 interface
  • Adjustable dimension
  • Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
  • Transducer programming with buttons or via PC (“LPConfig” software)
  • Current (AC / DC) transducer T23CT with 4...20 mA output
  • AC/DC current input (single option): up to 50 / 100 / 150 / 200 / 300 A
  • Optional mounting on DIN rail
  • Galvanic isolation
  • Supply: 24 VDC
  • Ambient temperature: -25...+55 °C
  • Protection class: IP65, IP40 for terminals
  • Meter to measurements electric quality parameters in 3 phase systems
  • Programmable display pages
  • 3 programmable alarm outputs and 1 pulse output
  • Digital transmission to the master system through the RS-485 interface
  • USB for configuration by using free eCon software
  • Primary current: 100...500 A or 300...800 A
  • Secondary current: 5 A
  • Hole diameter: 27 mm or 37 mm
  • Hole depth: 45 mm
  • Accuracy class: 1
  • Multimeter with backlit LCD screen (two shown values)
  • Four versions: NP10-2, NP10-3, NP10-5, NP10-6 TRMS (see datasheet below)
  • Capacity measurement from 1 pF to 40 mF
  • AC and DC voltage measurement from 100 μV to 1000 V
  • AC and DC current measurement from 10 μA to 10 A
  • Resistance measurement from 100 mΩ to 60 MΩ
  • Frequency measurement from 10 Hz to 10 MHz
  • Diode measurement and continuity testing
  • Hold function
  • Relative measurement
  • Duty cycle (%) measurement
  • Temperature measurement (K type thermocouple) from 0 to 1300 °C
  • Peak value measurement
  • Digital multimeter with data logging view function (up to 32000 readings) 
  • Four versions: NP15-2, NP15-3, NP15-5, NP15-6 TRMS (see datasheet below)
  • TRMS measurement
  • Low input impedance
  • Capacity measurement from 1 pF to 40 mF
  • AC and DC voltage measurement up to 1000 V
  • AC and DC current measurement up to 10 A
  • Resistance measurement
  • Frequency measurement
  • Diode measurement and continuity testing
  • Filtering
  • Square wave signal generator
  • Hold function, backlight, maximal and minimal value presentation
  • External supply
  • Duty cycle (%) measurement
  • Temperature measurement (K, J type thermocouples, Pt100 and Pt1000)
  • Automatic / manual range selection
  • USB connectivity (optional)
  • Digital multimeter for insulation resistance measurement
  • Multimeter with backlit LCD screen
  • AC and DC voltage measurement up to 1000 V
  • AC and DC current measurement up to 300 mA
  • Resistance measurement up to 30 mΩ
  • Insulation resistance measurement up to 3 GΩ
  • Capacitance measurement up to 30 μF
  • Frequency measurement up to 100 kHz
  • Fill factor measurement (%)
  • Hold function
  • Temperature measurement (Pt100 and Pt1000)
  • Diode check
  • Analog scale on screen
Loading...