- Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
- THD factor
- Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
- Digital output: RS-485 MODBUS (option)
- Protection class for front side: IP65
- Supply: 85...253 VDC/VAC
- Backlit LCD display
- Dimensions: 96 x 96 x 77 mm
- Measurement of power network parameters in 1-phase and 3-phase (3 or 4-wire) systems
- Current inputs 0,1 A and 0,25 A (for dedicated transformers)
- Quick and convenient ways to connect current transformers via RJ12 connector or screw terminals
- Designed for usage with following transformers: LJ12, LJ25, LJ35, LJ45, LJ306, LJ307, LJ308
- RS-485 (MODBUS RTU) interface
- THD factor measurement
- Backlighted LCD 3,5”
- Protection grade from the frontal side: IP65
Digital programmable indicator N20 for temperature, DC voltage and current measurement. Measures J, K, Pt100 temperature sensors’ signals.
Programmable parameters:
- LED indicator color, which changes depending on input signal value: green, yellow and red
- Value limits
- Measurement unit indication
- Cold junction compensation (CJC)
- Compensation for Pt100 sensors
- Averaging time
- Individual characteristic
- 2 OC alarms in 6 modes
Single-phase commutator – controller RP7. The device can be used or circuit commutations. Can be used for resistive and inductive loads and single-phase motor speed control. Possible control with standard analog signal.
Other functions:
- Load current limiting
- Soft start
- Isolated inputs
- Load current control
- Fuse failure detection
- Overload indication
Multifunctional professional current cramps NC12 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, frequency, temperature (with Pt100 and Pt1000 sensors), electric resistance and capacitance. Twistable clamp direction enables user to measure current in hard-reachable areas. Two variants are available: NC12-300A (up to 300 A AC) and NC12-1000A (up to 1000 A AC).
Multifunctional professional current cramps NC14 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, active, reactive, apparent power, inrush current, resistance, harmonics (up to 49th), phase angle, THD, power factor, DF, crest factor and power factor. Twistable clamp direction enables user to measure current in hard-reachable areas. Can be used in single- and three-phase (3 or 4 wire systems) networks. Two variants are available: NC14-400A (up to 400 A AC) and NC14-1000A (up to 1000 A AC).
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures barometric pressure using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures carbon dioxide (CO2) using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Portable analyzer NP40 is designed for power network quality parameter analysis
- Analyses voltage and current harmonics up to 51-st, THD
- Real-time waveform display (4 voltage / 4 current)
- Measurement of TRMS currents up to 3000 A (with standard sensor)
- Half cycle RMS measurement (voltage and current)
- Measurement in 1-phase and 3-phase systems (3- and 4-wire)
- Voltage, current, harmonics, power, energy and other parameter measurement
- Graphical representation of data in a waveform and vector diagram
- Record of events: dips, swells, overvoltages
- Built-in 8 GB memory card
- Ethernet interface for remote monitoring
- USB interface for data transfer
- Color 5,6” TFT display, 320 x 240 px
- Transducer for AC current and voltage into DC signal (1 output)
- Input, output and supply of the transducer are galvanic insolated
- The construction of the transducer ensures accurate and fast signal transformation
- Fast and easy installation on rail, or onto a wall or in panel using holder
- Transducer for DC current and voltage into other DC signal (2 outputs)
- Input, output and supply of the transducer are galvanic insolated
- The construction of the transducer ensures accurate and fast signal transformation
- Fast and easy installation on rail, or onto a wall or in panel using holder
- Signal transducer P20Z is designed to convert AC current and voltage (without direct component) into DC voltage or current signal
- Input is isolated from input and supply
- Has fixed inputs and outputs – non-programmable
Temperature and standard signal transducer P30U.
- Programmable input
- Mathematical functions
- Individual channel characteristic
- 1 or 2 outputs
- Variant with internal transducer 24 VDC power supply
- RS-485 interface
- Adjustable dimension
- Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
- Transducer programming with buttons or via PC (“LPConfig” software)
- Current (AC / DC) transducer T23CT with 4...20 mA output
- AC/DC current input (single option): up to 50 / 100 / 150 / 200 / 300 A
- Optional mounting on DIN rail
- Galvanic isolation
- Supply: 24 VDC
- Ambient temperature: -25...+55 °C
- Protection class: IP65, IP40 for terminals
- Meter to measurements electric quality parameters in 3 phase systems
- Programmable display pages
- 3 programmable alarm outputs and 1 pulse output
- Digital transmission to the master system through the RS-485 interface
- USB for configuration by using free eCon software
- Primary current: 100...500 A or 300...800 A
- Secondary current: 5 A
- Hole diameter: 27 mm or 37 mm
- Hole depth: 45 mm
- Accuracy class: 1
- Multimeter with backlit LCD screen (two shown values)
- Four versions: NP10-2, NP10-3, NP10-5, NP10-6 TRMS (see datasheet below)
- Capacity measurement from 1 pF to 40 mF
- AC and DC voltage measurement from 100 μV to 1000 V
- AC and DC current measurement from 10 μA to 10 A
- Resistance measurement from 100 mΩ to 60 MΩ
- Frequency measurement from 10 Hz to 10 MHz
- Diode measurement and continuity testing
- Hold function
- Relative measurement
- Duty cycle (%) measurement
- Temperature measurement (K type thermocouple) from 0 to 1300 °C
- Peak value measurement
- Digital multimeter with data logging view function (up to 32000 readings)
- Four versions: NP15-2, NP15-3, NP15-5, NP15-6 TRMS (see datasheet below)
- TRMS measurement
- Low input impedance
- Capacity measurement from 1 pF to 40 mF
- AC and DC voltage measurement up to 1000 V
- AC and DC current measurement up to 10 A
- Resistance measurement
- Frequency measurement
- Diode measurement and continuity testing
- Filtering
- Square wave signal generator
- Hold function, backlight, maximal and minimal value presentation
- External supply
- Duty cycle (%) measurement
- Temperature measurement (K, J type thermocouples, Pt100 and Pt1000)
- Automatic / manual range selection
- USB connectivity (optional)
- Digital multimeter for insulation resistance measurement
- Multimeter with backlit LCD screen
- AC and DC voltage measurement up to 1000 V
- AC and DC current measurement up to 300 mA
- Resistance measurement up to 30 mΩ
- Insulation resistance measurement up to 3 GΩ
- Capacitance measurement up to 30 μF
- Frequency measurement up to 100 kHz
- Fill factor measurement (%)
- Hold function
- Temperature measurement (Pt100 and Pt1000)
- Diode check