- Dual channel input: 0…24 mA or 0…10 V
- Communication interface: 1-Wire protocol
- Accuracy: ±1 %
- Resolution: 0.001mA / 0.001 V
- Galvanic isolation between the current circuit and 1-Wire bus
- Detection of special states such as sensor errors or calibration values
- Operating environment: -20…+60 °C / 10…90 %RH
- Warranty: 3 years
- 1-Wire protocol current transmitter
- Current measurement range: 0,3...15 A (AC / DC, set by jumper)
- Resolution: 10 bits
- Galvanic isolation between the current circuit and 1-Wire bus
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
TSC201 is a compact current sensor with a 1-Wire interface and an input range up to 10 A, designed for AC and DC current monitoring. Its range allows direct measurement of low currents or connection to current transformers (CTs) with 10 A secondary output for accurate indirect monitoring of higher currents.
- 1-Wire protocol current transmitter
- Current measurement range: 0,1...10 A (AC / DC)
- Measuring accuracy: ± 1 %
- Resolution: 0,01 A
- Galvanic isolation between the current circuit and 1-Wire bus
- Power supply: 4,0…5,5 V
- Excellent long-term stability
- Warranty: 3 years
- Digital inputs: 2
- 1-Wire input (up to 8 sensors)
- RS-485 input (up to 8 sensors)
- Analog inputs: 4 (2 x 0...10 VDC, 2 x 0...10 VDC / 4...20 mA, WEB control)
- Relay outputs: 4 (NO/NC)
- Setup via USB or SMS
- Data logger for up to 52 000 records
- Webserver
- Periodical upload of data logger file to a remote HTTP server
- HTTP Post, HTTP API
- Communication: 4G-LTE, 3G-WCDMA
- SMS alarms (up to 5 numbers)
- E-mail alarms (up to 5 recipients), SMT with TLS support
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- T22CT can be used for network analysis, monitoring and measuring of non -sinusoidal and distorted networks AC current
- Variations of measuring current range (A): 0...50 / 100 / 150 / 200 / 250 / 300 / 400 / 500 / 600 / 750
- Output: 4…20 mA or 0…20 mA (Proportional change to input current)
- Frequency range of Measuring current: 50…60 Hz
- High electric isolation between primary conductor and output
- Mounting onto 35 mm DIN rail by means of optional supply of snap on mounting
- Auxiliary power supply: 24 V DC, ± 15%
- Protection class: IP20
- Operating temperature and Humidity: 0…+70 °C, 0...95% RH without condensation
- Ethernet connection
- Analog outputs: 2 (0...20 mA / 4...20 mA / 0...24 mA / 0...5 V / 0...10 V)
- Digital outputs: 4 (PWM / ON/OFF)
- Relay outputs: 2 (NO/NC)
- Modbus TCP/IP support
- Webserver
- XML/JSON, HTTP API commands
- SNMP alarms (up to 5 recipients)
- Operating temperature: -10...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
The mini-size multimeter has multiple functions, such as auto range, auto scan (SMART) and true RMS functions, which makes it more convenient and intelligent. Besides normal multimeter function, it also has the function of NCV test and LIVE wire test, which is convenient for field testing. Blacklight and Flashlight capabilities facilitate use in dark work environment.
- CAT III 600V
- TRMS
- AC/DC Voltage measurement: 400 mV…400 V
- AC/DC Current measurement 40 mA … 10 A
- Resistance measurement 400 mΩ … 40 MΩ
- Capacitance measurement 4 nF…4 mF
- Frequency measurement
- Temperature measurement -200…1200 °C
- Auto Scan function (SMART)
- HOLD function, Continuity test and Diode test
- Dimensions: 130 x 62 x 27 mm
The VA702 is a Volt/mA/TC Calibrator, designed as a source and measurement tool. It measures or outputs a 0 to 24 mA DC current loop, 0 to 20 V DC voltage, and supports thermocouple temperature measurements (model dependent). Note: The calibrator cannot measure and source simultaneously.
- Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
- Storage temperature: -40℃ to 60℃
- Operating temperature: -10℃ to 50℃
- Operating altitude: Up to 2000 meters
- Temperature coefficient: ±0.01% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
- Relative humidity:
- 95% up to 30℃
- 75% up to 40℃
- 45% up to 50℃
- 35% up to 55℃
- Power requirements: 6 x AAA batteries
- Size: 204mm (L) x 99mm (W) x 46mm (H)
- Weight: 460g (including battery)
The VA700 Loop Calibrator is a versatile source and measurement tool. It is designed to measure or output a 0 to 24 mA DC current loop and 0 to 20 V DC voltage. The calibrator cannot measure and source simultaneously.
- Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
- Storage temperature: -40℃ to 60℃
- Operating temperature: -10℃ to 55℃
- Operating altitude: Up to 3000 meters
- Temperature coefficient: ±0.005% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
- Relative humidity:
- 95% up to 30℃
- 75% up to 40℃
- 45% up to 50℃
- 35% up to 55℃
- Shock: Random 2g, 5Hz to 500Hz
- Safety: 1 meter drop test
- Power requirements: 6 x AAA batteries
- Size: 204mm (L) x 99mm (W) x 46mm (H)
- Weight: 460g (including battery)
- Voltage range: 0,2...1000 V
- Current range: 20 mA...20 A
- Frequency range: 40...5000 Hz
- DC voltage and currency accuracy: 0,02 %
- AC voltage and currency accuracy: 0,05 %
- Load capacity up to 40 VA
- USB, RS232 interfaces
- Ambient temperature: 23 °C ±5 °C
Portable calibrator for DC voltage and current.
Purpose:
- Calibration and verification of temperature measurement equipment
- Measurement and control equipment monitoring
- Current loop circuit monitoring
- Measurement of 85 power network parameters, including current and voltage harmonics up to 31st in 1-phase 2-wire or 3-phase 3 or 4-wire.
- Accuracy of active energy measurement 0.5S or 0.2S
- RS-485 (Modbus RTU) interface for remote monitoring of measured parameters
- The dual-tariff function for energy billing applications
- 2 relay outputs
- Pulse output: SO output as pulse or alarm
- 2 digital inputs as energy consumption, pulse counting and contact status
- Measured values displayed in 10 configurable screens
- Possibility programming of current and voltage ratio without restrictions as in MID-certified products
- Measurement inputs dedicated for x/1A and x/5A current transformers
- Power supply: 100…550 V a.c. / d.c.
- DIN rail mounted
- Analog inputs: 6 (0...10 VDC / 4...20 mA, configurable, isolated)
- Digital inputs: 4 (isolated)
- RS-485 input (up to 24 Modbus RTU registers)
- Memory: 70 000 values
- Ethernet connection
- Modbus RTU to Modbus TCP conversion
- Webserver
- Periodical upload of data logger file to a remote HTTP server
- HTTP Post, HTTP API
- SNMP alarms (up to 5 recipients)
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- Digital inputs: 2
- 1-Wire input (up to 8 sensors)
- RS-485 input (up to 8 sensors)
- Analog inputs: 4 (2 x 0...10 VDC, 2 x 0...10 VDC / 4...20 mA, WEB control)
- Relay outputs: 4 (NO/NC)
- Setup via USB or SMS
- Data logger for up to 52 000 records
- Webserver
- Periodical upload of data logger file to a remote HTTP server
- HTTP Post, HTTP API
- SMS alarms (up to 5 numbers)
- E-mail alarms (up to 5 recipients), SMT with TLS support
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...24 VDC
N19Z meter measures AC voltage and current. The meter is designed to work in 3-phase networks or 1-phase networks.
- Nominal input voltage: 300 or 600 V 1 phase / 100…500 V 3 phase
- Nominal input current: 1A or 5A
- True RMS measurement (up to 15th Harmonic)
- On site programmable PT/CT ratios
- User selectable 3ph3wire or 3ph4wire Network (for 3ph)
- Onsite selection of Auto scroll / Fixed Screen (for 3ph)
- 4 Digits 14mm ultra bright LED Display
- Protection: IP54 front / IP20 back
- Parameter Screen recall: In case of power failure, the instrument memorizes the last displayed screen
- Accuracy: ±0.5% of nominal value
The enLink Status-VC transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- 0…20 mA, 0…10 V or resistance input
- 12 bit resolution
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours
- 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
- Configuration via USB cable / downlink
- Case IP40 protection (IP 67 on request)
- Measures and records parameters in 3 and 4-wire, 3-phase, balanced or unbalanced power network
- Up to 500 electrical network quality parameters according to EN 50160, EN 61000-4-30, standards
- Measuring class A or A / S
- Support the IEC 60870-5-104 communication protocol (new - option)
- Analysis of voltage and current harmonics and interharmonics (up to the 51-st)
- Monitoring up to 6 additional energy meters with pulse output
- Recording of measurements before and after events (dips & swells)
- Configurable archives of logged values and events
- SD card support (up to 32 GB)
- Webserver function, FTP server, DHCP client
- Outputs: relays, binary, analog
- Binary inputs
- E-mail alarms
- Interfaces: RS-485 Modbus slave, Ethernet 100 Base-T (Modbus TCP server), USB device and host
- Color touchscreen: LCD TFT 5.6“
- Many data representation modes (i.e. digital display, analog, bar graph, vector diagram)
- IP65 protection class for front side
- Real time clock (RTC) synchronization with NPT time server
- Time synchronization via external GPS module - STR receiver (new - option)
Measurement of 54 power network parameters, including current and voltage harmonics up to 63rd in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems
- High accuracy class (0.2S for active energy)
- Interface: RS-485 (Modbus RTU 8N2,8E1,8O1,8N1)
- Graphical color display: LCD TFT 3,5’’, 320 x 240 pixels, fully configurable by a user (10 screens, 8 parameters in each)
- Additional 2 screens for harmonics presentation and 1 dedicated screen for visualization in the form of an analog meter
- Memory of minimum and maximum values
- 2 configurable alarm outputs
- Supervisory relay mode for alarm outputs
- Password protection
- Programming of parameters using free eCon software
- Battery backup RTC
- Supply: 85...253 V ac / 90...300 V dc
- Operating temperature: -10…23…+55 °C
- Overall dimensions: 96 x 96 x 77 mm
- Pressure range: from 0...2,5 to 0...700 bar
- Process temperature: -40...+125 °C
- Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
- Protection class: IP65, IP67
- 2 analog outputs (operating simultaneously):
1. Current 4...20 mA or 0...20 mA (active output, cannot be supplied in two-wire current loop);
2. Voltage 0...10 V. - Soft start/stop (ramping) or a triangular wave generator triggered manually or automatically after switching power on
- 7-segment LED display with adjustable brightness
- Optional RS485/RS232 serial interface (galvanically isolated, MODBUS-RTU communication protocol)
- Password protection
- High accuracy and immunity to interference
- Supply: 230 VAC or 24 VAC/VDC
- Panel housing 96 x 48 x 79 mm
- Protection: IP65 (front) / IP20 (back)
Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. For direct (up to 63A) and indirect measurement (x/1A or x/5A). Indications considering values of programmed ratios.
- Molded epoxy resin protects against aggressive environmental factors
- Primary current: 60...160 A or 200...320 A
- Secondary current: 1 A or 5 A
- Hole diameter: 30 mm or 50 mm
- Hole depth: 50 mm or 40 mm
- Accuracy class: 1
- LW and LE series of current transformers with a round hole for a cable
- Ranges of primary current from 50A up to 5000A
- Maximum operating voltage 0,72 kV
- Secondary current: 1A or 5A
- Accuracy classes: 0.2S, 0.2, 0.5S, 0.5, 1; 3
- Terminals of the secondary circuit are protected by cover that protects them against accidental contact
- Operating temperature: -10…+55 °C
- Signal splitter DAT5022
- Configurable with switches on body
- 3-way galvanic isolation (2000 VAC)
- Input: 4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V
- Output: 2 X (4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V)
- Power Supply: 18...32 VDC. Reverse polarity protection 60 VDC
- Current Consumption: Current output 35 mA max. Voltage output 25 mA max.
- Environment: -20...+70 °C / (non-condensing) 0-90%
- Housing: Self-extinguishing material
- EMC
- Immunity: EN 61000-6-2
- Emission: EN 61000-6-4
They are used to regulate the power delivered to the receiver, where this power is proportional to the input control signal. They are used in automation control systems where smooth control of receiver power is required for resistive or resistive-inductive loads. Typical applications for power controllers: heaters, industrial furnaces (annealing, quenching, drying, etc.), dryers, plastics processing equipment, industrial sealing machines, glass production industry, industrial heating systems (matting and lining of pipelines), load transformers.
- Single-phase power controller (phase angle load control)
- Control input: DC voltage 0...10 V DC (RSR92-..V..) or current 4...20 mA (RSR92-..I..)
- SCR output (thyristors)
- Load current 25...80 A
- Max. load voltage 280, 530 V AC (single-phase)
- Dielectric strength 4 000 Vrms (opto-isolation)
- MOV protection (built-in varistor)
- Mounting on panel or on heatsinks
- Recognitions, certifications, directives: RoHS, REACH, CE, EAC
- Available versions with 2 to 8 primary windings
- Nickel plated secondary terminals
- Multiple mounting methods, including wall mounting and on DIN rail
- Applicable standard: IEC 61869-1/2
- Rated primary current: (2...8) x 5 A
- Rated secondary current: 5 A
- Rated burden: 5 / 10 / 15 / 20 / 25 A
- Max system voltage: 720 V
- Operating temperature: -25...+40 °C
- Accuracy class: 0,5 / 1
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures carbon dioxide (CO2) using the integrated sensor.
- Measures barometric pressure using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
They are used to regulate the power delivered to the receiver, where this power is proportional to the input control signal. They are used in automation control systems where smooth control of receiver power is required for resistive or resistive-inductive loads. Typical applications for power controllers: heaters, industrial furnaces (annealing, quenching, drying, etc.), dryers, plastics processing equipment, industrial sealing machines, glass production industry, industrial heating systems (matting and lining of pipelines), load transformers.
- Three-phase power controller (phase angle load control)
- Control input: DC voltage 0...10 V DC or current 4...20 mA
- SCR output (thyristors)
- Load current 25...80 A
- Max. load voltage 530 V AC (three-phase)
- Dielectric strength 4 000 Vrms (opto-isolation)
- MOV protection (built-in varistor)
- Mounting on heatsinks
- Recognitions, certifications, directives: RoHS, REACH, CE, EAC
- Transducer for DC current and voltage into other DC signal (1 output)
- Input, output and supply of the transducer are galvanic insolated
- Solves grounding problem in meshed signal networks
- User selectable type and range of input
- EDP2041 is standard signals generator (digital potentiometer) with outputs:
- 0…10 V; Resolution: 1 mV; Fluctuation: max 30 mA; Rise time from 0 to 10V is max. 300ms
- 0 / 4…20 mA; Accuracy: 0.1 %; Resolution: 2 µA; Fluctuation: max. 60 µA
- Preset value can be adjusted from external buttons
- Communication via RS-485 Modbus protocol or synchronous running between two or more potentiometers
- Display scale can be adjusted between -1999 and 9999
- Soft on and soft off properties can be selected
- 4 digits display
- Parameter access protection on 3 levels
- Supply: 230 V AC; 24 V AC; 9…30 V DC
- Ambient temperature: 0…50 °C
- Universal datalogger with 4 inputs for voltage, current, logic and pulse signals.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Open collector transistor alarm output.
Measures analog signal of a 3rd party sensor. Provides 24 or 12 VDC power for a 3rd party sensor using the built-in power supply unit (PSU).
- Sensor compatible with base stations: PRO, PRO Plus ir PRO Plus LTE
- Current measurement range: 0...30 mA
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Operating temperature: -30...+80 °C
- Power supply: 85…265 VAC
- 1 x AA battery is for to notify user in case of external
- Protection class: IP67
- Current measurement range: 0...30 mA
- Operational range (in line-of-sight): up to 3 km
- Cable length: 1 m
- Data transmission: 1, 2, 5, 10 min
- Data encryption
- Supply: 1 x AA battery
- Battery lifetime (20 °C): up to 10 years
- Operating temperature: -40...60 °C
- Protection class: IP68
Designed for precisely measuring electricity usage and frequency of use. Pulse counter belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.
- Compliance with MID certificate
- Maximum current: 40 A
- Nominal voltage: 230 V, 50 Hz
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Data encryption
- Supply (pulse counter): 1 x AA battery
- Battery lifetime (20 °C): up to 10 years
- Protection class sensor / meter: IP67 / IP40
Designed for precisely measuring electricity usage and frequency of use. Pulse counter belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.
- Compliance with MID certificate
- Maximum current: 80 A
- Nominal voltage: 3 x 230 / 400 V, 50 / 60 Hz
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Data encryption
- Supply (pulse counter): 1 x AA battery
- Battery lifetime (20 °C): up to 10 years
- Protection class sensor / meter: IP67 / IP40
Bimetallic ammeters BA27, BA39, BE27, BE39 indicate flowing current and maximal flown current. When the user presses the button on the front of ammeter, maximal current indication arrow returns to the actual value.
BE27 and BE39 additionally indicate average current of 8-15 minute timespan. They are fit to indicate thermal current indication in transformers, cables and other electric devices. Measuring range can be extended according to customer’s demand.
- Panel electromagnetic devices are designed to measure effective values of current and voltage
- The devices are fit to be mounted in up to 15 mm-thick panels
- Meter EB16 is mounted on 35 mm rail
- Tropical version is also available
- Ammeters for use with transformers (X/1A and X/5A) available
- Panel devices are designed to measure AC and DC current and voltage
- Those with P index have integrated rectifier which enables the device to measure effective currents and voltages
- Asymmetric form signal measurement accuracy depends on harmonic component levels
- The devices are fit to be mounted in up to 15 mm-thick panels
- Meter MB16 is mounted on 35 mm rail
- Tropical version is also available
- Ammeters for use with transformers (X/1A and X/5A) available
- Measures and records power network parameters in single phase or three phase 3 and 4-wire symmetrical and asymmetrical systems
- 54 electrical network quality parameters
- Analysis of voltage and current harmonics (up to the 51-st)
- Color touchscreen: LCD TFT 3.5“, 320 x 240
- 2 configurable alarm outputs
- Analog output 0/4...20 mA and 2 x Pt100 inputs (optional)
- Digital output: RS-485 (MODBUS)
- Ethernet / Profinet 2.2
- Supply: 85...253 VAC / 90...300 VDC or 20...40 VAC / 20...60 VDC
- Battery backup RTC
- Dimensions: 96 x 96 x 77 mm
Power network meter N100 for electric quality to measurements parameters 3 and 4-wire, 3-phase, balanced or unbalanced power network systems with data logging.
The measurement of: values of voltage and current, active, reactive and apparent power, active, reactive energy, power factors, frequency, up to 51st THD.
- Two-color LED display
- Backlit units of all measured quantities
- Configurable analog and alarm outputs
- Digital RS-485 interface, MODBUS
- Archiving data in the internal memory file system memory 8 GB
- Ethernet interface, protocol: MODBUS TCP/IP, HTTP, FTP
- services: www server, ftp server, DHCP client
Digital meters – bargraphs NA3, NA5, NA6,measurement of DC voltage, current, resistance and temperature measurement (with thermal sensors J, K, N, E, R, S, T, Pt100, Pt500, Pt1000).
Digital programmable indicator N20Z for AC voltage, current and frequency measurement.
Programmable parameters:
- LED indicator color, which changes depending on input signal value: green, yellow and red
- Value limits
- Measurement unit indication
- Decimal point location
- Measured signal
- Averaging time
- Individual characteristic
- 2 OC alarms in 6 modes
Digital programmable indicator N24 for temperature, AC/DC voltage and current measurement. Measures J, K, Pt100 temperature sensors signals.
Programmable parameters:
- Value limits
- Decimal point place
- Measurement unit indication
- Cold junction compensation (CJC)
- Compensation for Pt100 sensors
- Averaging time
- Individual characteristic
Digital, programmable indicator N30H for DC voltage, current, with RS-485 interface.
- Device is designed for DC (bi-polar) voltage, current measurement
- LED indicator colors: red, green, yellow (for 3 input value ranges)
- Device is programmed with buttons or via RS-485 port
- 4 alarm inputs in 6 modes
- Measurement value conversion into analog signal 0/4...20 mA arba 0...10 V
- Minimal and maximal value storing for all measurements
- Input:
- temperature:
- resistance thermometers: Pt100, Pt500, Pt1000
- thermocouples: J, K, N, E, R, S
- resistance: 400 ohm, 4000 ohm
- current: ± 20 mA
- voltage: 0…10 V, -10…60 mV
- temperature:
- Output: relay (4), analog (1), digital RS-485/MODBUS (1),
- Three-colour display - red, green and orange, programmable in three intervals of the measured value – facilitates the observation of measured value changes.
- digit height: 14 mm
- highlighted measuring unit
- Four alarm outputs with signaling on LED diodes operating in six different modes.
- Input (single option): 100 V, 250 V, 400 V, 1 A, 5 A, 20...500 Hz
- Digital output: RS-485 (Modbus RTU)
- Relay outputs: 2x OC
- Display: 3-color LED, 5-digit
- Galvanic isolation
- Supply: 85...253 VAC/VDC / 20...40/60 VAC/VDC
- Protection class: IP65
- Input (single option): Pt100, J, K, 0...20 mA, 4...20 mA, ±20 mA, 0...75 mV, 0...10 V, ±10 V, 0...150 mV, ±75 mV, V150 mV
- Voltage measurement range: 0...75 mV; 0...150 mV; 0...10 V (DC)
- Current measurement range: 0/4...20 mA; ±20 mA (DC)
- Temperature measurement range: -50...400 °C (Pt100); -50...1200 °C (J) / -50...1370 °C (K)
- Digital output: RS-485 (Modbus RTU)
- Relay outputs: 2x OC
- Auxiliary 24 VDC output to supply transducers
- Display: 3-color LED, 5-digit
- Temperature compensation
- Galvanic isolation
- Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
- Protection class: IP65
- Digital, programmable power network parameter meter N30P with RS-485 interface
- Measures voltage, current, frequency, active, reactive power, cosφ, tgφ, energy consumption
- Programmable with keys or via computer
- Designed for direct or indirect measurement of 1-phase network parameters
- Measured values: U, I, f, P, Q, S, PF, tg fi, fi, Ep, Eq
- Direct measurements up to 63 A
- Universal input: 1/5 A 100/400 VAC or 32/63 A, 100/400 VAC
- Outputs: RS-485 (MODBUS interface), 1x relay + 1x analog or 2x relay
- OLED display
- Programmable current and voltage transformer ratios
- Programmable via buttons or free eCon software (through USB)
- Size: 53 x 110 x 60 mm