The RE4X series controllers have a wide range of process control options and versions. Programmable inputs for standard signals, signal difference measurement between channels, control algorithms ON / OFF, PID, soft start and Fuzzy logic. Remote control with SCADA system through RS-485. The required output types can be selected during ordering (relays, SSR, analog).
Main features:
- Sampling rate (5 times / second)
- 1 input: TC and RTD sensors; standard signals 0 / 4…20 mA and 0…10 V
- 2 input: 0 / 4…20 mA and 0…10 V
- Binary input for changing the function of the controller and SP switching
- Outputs: relays - NO, SSR; analog - 0 / 4…20 mA and 0…10 V
- Galvanically isolated transducer and sensors power supply 24 V d.c. 25 mA
- Programmable digital filter
- Hardware and software security before changing settings
- Alarm for breaking the control loop
- Supply: 90…264 V a.c. or 11…26 V a.c. / d.c.
- Protection class: IP65
- Pressure range: from -0,9...1,5 to 4...40 bar
- Output signal: 1 Floating change-over contact (SPDT)
- Process temperature: -40...+150 °C
- Process connection: G1/4" f, G1/2" m, 1/4" NPT f
- Protection class: IP65
Environmental monitoring gateway with an integrated touchscreen dashboard.
Gateway Pro is the central hub for your Aranet wireless sensor network. It collects data from connected sensors and forwards it to Aranet Cloud or to local integrations for real-time monitoring. The built-in touchscreen enables quick on-site setup and sensor pairing. Full gateway management, data visibility, and analytics are available via Aranet Cloud. Gateway Pro supports Wi-Fi or Ethernet and integrations via MQTT and Modbus TCP/IP.
- Maximum sensor count: 100
- Storage: no local storage, cache memory of up to 7200 readings in case connection to Aranet cloud lost
- Radio sensitivity allows receiving signals from sensors up to 3 km away (in plain sight)
- Port: RJ45 with PoE 802.3af power and internet input or USB-C 5 VDC 1 A power input
- Communication: Ethernet, Wi-Fi 2.4 GHz client mode
- Supported Aranet sensors: CO2, Temperature, Radon, Particle matter (PM), Soil moisture. (For specific models see datasheet)
- Integrations: MQTT, Modbus TCP/IP, (BACnet IP and InfluxDB coming soon)
- Operating environment: 0...45 °C / 0…90 % RH
An environmental monitoring solution that acts as a gateway, data storage, and web server. Receives sensor measurements from Aranet PRO series devices using Aranet Sub-GHz ISM band radio. Features rugged IP67 casing for outdoor use and PoE power input for ease of commissioning. Additionally, 4G LTE connectivity enables usage in areas lacking local internet access.
Using Aranet Cloud* provides centralized and remote access to data from any number of sensors and base stations, with all sensors accessible in one place.
- Maximum sensor count*: 100/50/12
- Alarms: email, SMS
- Local data storage: up to 10 years for 100 sensors
- Radio sensitivity allows receiving signals from sensors up to 3 km away (in plain sight)
- Port: RJ45 with PoE 802.3af power input
- Communication: Ethernet, Wi-Fi 2.4 GHz access point or client mode, 4G LTE
- Data protection methods: XXTEA, HTTPS, password-protected user accounts
- Integrations*: MQTT, Modbus TCP/IP, BACnet IP
- Operating temperature: -40...60 °C
- Protection class: IP67
Broadsens edge-computing wireless gateways connect and control multiple wireless low-power sensors such as SVT200-A, SVT300-A, SVT400-A, SVT200-V, SVT300-V and SVT400-V.
BroadVibra software is installed inside the wireless gateway. The software has intuitive interface and can be accessed from all major web browsers remotely. The software is ideal for predictive maintenance and conditional based monitoring.
- Communication with sensor: 2.4GHz BLE
- Up to 190 sensors supported
- Network interface: Ethernet, Wi-Fi 802.11ac wireless
- Communication protocol: MQTT, TCP/IP, UDP, Modbus TCP & RTU (RS-485), OPC UA
- Integrated Database: 64 / 128 GB
- Notifications and alarms sent by email (SMTP)
- Vibration analysis: Velocity, RMS, True peak, Peak-peak, STD, Crest factor, Kurtosis, trend analysis, FFT analysis, advanced filtering, frequency fine tuning, trigger modes
- Working environment: -30...+60 °C, 10...90 %RH
- Additional features: 2nd power connector, 2 x GPIO ports (input or output, see manual)
Sensor SKU: 5905309601369 (IP30)
Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.
- Sensor detects change of state (open / close) with reed switch
- Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
- Possibility to integrate sensor to other third-party systems
- Operating temperature / humidity: -35…+70 °C / 0…99 %
- Case IP30 protection
Sensor SKU: 5906660327691 (IP30) – plastic magnetic detector
Sensor SKU: 5906660327707 (IP30) – metal magnetic detector
Sensor SKU: 5905309600768 (IP67) – metal magnetic detector
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.
- Sensor detects change of state (open / close) with reed switch
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 1 minutes to 18 hours (configurable by the user)
- Measurement sending interval: 5 minutes to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Possibility to integrate sensor to other third-party systems
- Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
- Case IP30 protection (IP67 on request)
Sensor SKU: 5905309602588 (IP30)
Sensor SKU: 5905309602595 (IP67)
Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.
- Supported thermocouple types: B, E, J, K, N, R, S, T
- Accuracy: depends on the connected thermocouple type
- Resolution: 0.1°C
- Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh, 3xAA battery (replaceable)
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
- Possibility to integrate sensor to other third-party systems
- Operating temperature / humidity: -15…+70 °C / 0…99 %
- Case IP30 protection (IP 67 on request)
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third-party systems.
- Supported thermocouple types: B, E, J, K, N, R, S, T
- Accuracy: depends on the connected thermocouple type
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 5 seconds to 18 hours (configurable by the user)
- Measurement sending interval: 1 minute to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Possibility to integrate sensor to other third-party systems
- Operating temperature / humidity: -15…+70 °C / 0…99 %
- Case IP30 protection
- SF6 gas density monitor for high voltage switchgear
- Three versions: 1 / 2 / 3 stages (8781 / 8782 / 8783)
- Measurement range: 0...1,1 MPa (mechanical), 0...0,85 MPa (electronic)
- Output signal: floating change-over contact (SPDT) / 6.5...20 mA current loop
- Switch point: factory calibrated
- Media temperature: -40...+80 °C
- Ambient temperature: -40...+80 °C
- Protection class: IP65
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø9,8 mm
- Length: 1...35 m
- Tensile strength: ≤ 2,5 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø17 mm
- Length: 1...100 m
- Tensile strength: ≤ 8 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
Room thermostat, temperature switch with an electric socket RTBSB-001.401.
- Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
- Measuring principle: piston
- Measured pressure from -0,6...3,4 to 4...40 bar
- Output signal: floating change-over contact (SPDT)
- Switching differential: not adjustable
- Media temperature: -25...+125 °C / -40...+125 °C
- Ambient temperature: -25...+125 °C / -40...+125 °C
- Protection: IP65
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H
- Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
- Measuring principle: piston
- Measured pressure from 1...10 to 40...400 bar
- Output signal: floating change-over contact (SPDT)
- Switching differential: not adjustable
- Media temperature: -25...+125 °C
- Ambient temperature: -25...+85 °C
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, EN60730-1 / EN60730-2-9: Typ 2.B.H
- Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
- Measuring principle: membrana
- Measured pressure from 1...10 to 10...100 bar
- Output signal: floating change-over contact (SPDT)
- Switching differential: not adjustable
- Media temperature: 0...+80 °C
- Ambient temperature: 0...+80 °C
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, EN60730-1 / EN60730-2-6: Typ 2.B.H
- Compact thermostat for shipbuilding
- ISP version – with capillary tube, ISPT version – without capillary tube
- Measured temperature from +5...95 °C to +20...150 °C
- Switching differential: not adjustable
- Output signal: floating change-over contact
- Ambient temperature: -30...+70 °C
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H
- Multipoint float level switches AUREGIS LJ-VD for fluid level measurement and control
- Multipoint level switch LJ-VD main difference from LJ-V is that LJ-VD uses up to 3 floats instead of one, that ensures control and measuring in more than one level
- Multipoint float level switches LJ-VDT for fluid level measurement and control
- Multipoint level switch LJ-VDT main difference from LJ-VT is that LJ-VDT uses up to 3 floats instead of one, that ensures control and measuring in more than one level
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Deactivation of the control system in the case of excessive temperature, or in the case of sensor error
- Universal input for thermocouples and resistance thermometers
- Relay output for disconnecting the temperature control system
- Supply: 230 VAC
- Operating temperature: 0...50 °C
- Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Float level switches AUREGIS LJ-V with an extension for level control
- Operating temperature: -30...+130°C
- Protection class: IP65
- Temperature regulator for usage with Pt100, Pt1000 or NTC sensors
- PID or ON/OFF control
- Automatic selection of PID parameters
- One relay output and one alarm relay
- Manual control mode
- One binary input
- Operating temperature: 0...50 °C
- Supply: 230 VAC
- Protection class: front IP65, back IP20
- Used for controlling pumps in traditional boosting systems, with expansion tank
- Possible ranges: 1,5...6 bar, 4...10 bar (programmable)
- 1- or 3-phase
- Mounting on pipe
- Operating temperature: 0...50 °C
- Supply: 117/230/400 VAC
- Protection class: IP44
- Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
- Measuring principle: bellow
- Measured pressure from -0,9...1,5 to 10...100 bar
- Output signal: floating change-over contact (SPDT)
- Switching differential: not adjustable
- Media temperature: -40...+150 °C
- Ambient temperature: -25...+70 °C
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, EN60730-1 / EN60730-2-6: Typ 2.B.H
- Industrial temperature protectors (temperature switches) TS-M, TS-B, TS-1, TS-4, designed for temperature control
- Temperature switch is designed to control when set temperature is reached
- Depending on type, after cooling about 30±15K from base temperature, the temperature switch returns to initial state
- Measurement range: -40…+180 °C
- Type: J / K / N / T / E
- Self-adhesive tape
- Thermocouple tolerance (accuracy), cable length and insulation can be chosen by demand (see datasheet)
- Optional: temperature transducer (4...20 mA / 0...10 V / HART / Profibus PA / Fieldbus)
- Optional: connector
Temperature relay, mechanical thermostat ATR83 with pipe-mounting for temperature control.
Temperature relay, mechanical thermostat JTF-1 for frost protection.