- Датчик температуры AUREGIS ТJ-1 с соединительным кабелем
- Предназначен для измерения температуры в диапазоне -50°C до 400°C
- Возможны исполнения по требованиям заказчика
- Тип сенсора: PT100, PT1000, K, J, PTC, NTC, Ni120, Ni1000
- Input: 2x thermocouples - J, K, T, N, E, B, R, and S
- Output: Modbus RTU – RS-485
- Resolution: 24 bits with DSP processing
- Working isolation voltage: 1500 Vrms
- Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
- DIN rail mounting
- Power supply: 5…30 Vdc
- Warranty: 3 years
The VA702 is a Volt/mA/TC Calibrator, designed as a source and measurement tool. It measures or outputs a 0 to 24 mA DC current loop, 0 to 20 V DC voltage, and supports thermocouple temperature measurements (model dependent). Note: The calibrator cannot measure and source simultaneously.
- Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
- Storage temperature: -40℃ to 60℃
- Operating temperature: -10℃ to 50℃
- Operating altitude: Up to 2000 meters
- Temperature coefficient: ±0.01% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
- Relative humidity:
- 95% up to 30℃
- 75% up to 40℃
- 45% up to 50℃
- 35% up to 55℃
- Power requirements: 6 x AAA batteries
- Size: 204mm (L) x 99mm (W) x 46mm (H)
- Weight: 460g (including battery)
Universal calibrator-meter Inmel 60 for automation tuning.
Compact sensor VA 525 for measuring compressed air or nitrogen inline.
- 4...20 mA and pulse or a Modbus RTU (RS 485) interface as standard
- Optional interfaces such as Modbus TCP (Ethernet), PoE, M-Bus available
- Pressure range up to 16 bar
- Temperature range up to 60°C
- For speeds up to 224 Nm/s
- Integrated display to show the measured values
- Available from 1/4" to 2''
- Settings adjustable via the keys of the display
- Main counter can be reset via the display
The DPI series electronic pressure measuring devices are engineered for building automation in HVAC/R industry. The most technologically advanced and versatile electronic differential pressure switches on the market, combining up to two relay outputs and 0–10 V output options.
Differential manometer DPG/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.
- Range: 0…1500 Pa
- Switch activation range: 20…1500 Pa
- Operating temperature: -5… +60°C
Differential manometer MM/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.
- Range: 0…1500 Pa
- Switch activation range: 40…1500 Pa
- Operating temperature: -20… +60°C
- Pressure range: from -1...6 to -1...18 bar
- Output signal: 1 Floating change-over contact (SPDT)
- Process temperature: -40...+150 °C
- Process connection: G1/4" f, G1/8" f, G1/2" m
- Protection class: IP65
Differential pressure switch is designed for use in air and non-aggressive gasses. Made by HK Instruments (Finland).
Utilizing unique dual-sensing technology, the device combines electromagnetic induction with an integrated ultrasonic sensor to provide highly accurate detection of both liquid level and flow velocity. Specifically optimized for partially filled pipes, open channels, and gravity-fed systems, the unit achieves an outstanding accuracy of ±1–2% of the actual flow rate.
- Internal pipe diameter: DN80…DN600
- Flow velocity (min. / max.): 0,46…7,5 m/s
- Accuracy: ± 1…2 % of actual flow (depends on flow profile and level detection)
- Process Temperature: 0…+70 °C
- Coating materials: hard rubber
- Maximum working pressure: No pressure (gravity flow) or 10 bar if pipe is full
- Output signal: 2× pulse / flow switch (max. 400 Hz), 4 ... 20 mA, 1× RS485 interface (Modbus / M-Bus protocol), M-Bus, HART, Ethernet module (TCP/IP, integrated web server)
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Data archiving on a micro-SD card
- Process connections: flange
- Maximum ambient temperature: 55 °C
- Power supply: 24 V AC / DC, 230 V AC
- Protection class: IP68 for sensor, IP65-IP68 for transmitter
- Exi thermocouple sensors for explosive atmospheres
- Range: -40...+1200°C
- Exi thermocouple sensors for explosive atmospheres with cable
- Range: -40...+400°C
- Exi thermocouple sensors for explosive atmospheres with connection head
- Outputs: TC, 4..20 mA
Thermal mass flow sensor for compressed air and gases VA 500
- 4...20 mA, pulse and a Modbus RTU (RS 485) interface as standard
- Optional: Interfaces such as Modbus TCP (Ethernet), PoE, M-Bus
- Optional: Bi-directional measurement
- Pressure tight up to 50 bar
- Temperature range up to 110 °C
- Protection class IP65
- Suitable for gas velocities up to 224 Nm/s
- Integrated display for showing the measured values
- Can be used from 1/2" up to 40", larger diameters on request
- Easy installation under pressure
- Settings can be changed via the display
- Main counter reading can be reset via the display
- Data converter which connects reader in safe zone with network switches and temperature cables/spears in dangerous zone
- Input: 4 x temperature cables (from switches GWNET11 and cables GWSL 1100 or GWSL 2100)
- Output: Modbus RTU, RS-485
- Reads data from 68 individual temperature cables and spears
- Supply: 230 VAC / 115 VAC
- Protection class: IP66
- Certificates: IECEx, ATEX
- Works as a multiplexer, enabling 4 additional temperature cables or spears to be connected to GWAB11 converter
- Another GWNET11 can be connected in parallel, further expanding inputs of GWAB11 by 4
- Operating temperature: -20...+50 °C
- Protection class: IP66
- Certificates: IECEx, ATEX
- Data logger (4 MB, up to 1 year of backup)
- Sample rate: 60 s...18 h
- Communication: GSM/3G/HSPA/Telstra arba GSM/2G/GPRS arba CDMA/Verizon
- Certificates: FCC, ETSI, C-TICK
- Option: GPS
- 1 input: for sensors with SDI-12 interface
- 2 input: double analog/digital/counter input or I2C interface
- USB connection: for charging and RanchMgr communication
- LCD screen
- Remote control
- Solar panel
- Supply: battery (typical run time without sunlight is 1 month)
- Used with grain temperature sensor cables GWSL 1100, GWSL 2100 and spear sensors GWTL-R
- Cable length up to 200 m (including the temperature cables)
- Up to 32 values of temperatures are shown in cycle
- Weight: 240 g (with batteries)
- Case material: ABS
- Supply: 2 x AA (battery life circa 1 year)
- Operating temperature: -20...+40 °C
RFLS-53 can be used in demanding applications to indicate powder, dust and hygroscopic materials and can replace mechanical rotary level switches or standard capacitive level switches.
- The RFLS-53 uses the principle of high-frequency capacitive measurement
- It responds to the mass of the material and ignores deposits and material residues on the measuring part
- For demanding applications to indicate powder, dust and hygroscopic materials
- The sensor is available in several versions with different types of outputs and electrical connections
- The RFLS-53 fully replaces the older CLS-53, its electrical connection is different for the 230 VAC version (3 wires)
- Pressure range: from 0...2,5 to 0...600 bar
- Output signal: 1 or 2 PNP transistors
- Process temperature: -40...+125 °C
- Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
- Protection class: IP65, IP67
Industrial IoT module TCW242 for remote real-time monitoring and control of industrial equipment, facilities, production lines, renewable energy systems, greenhouses and water stations
- Web-based configuration and control with password protection
- 4 digital inputs for dry contacts
- 4 analog inputs with 0-10V and 0-20mA options
- 4 relays with normally open/normally closed contacts
- RS-485 interface for MODBUS RTU sensors. Up to 24 sensors (registers)
- Monitor up to 24 channels
- Set up to 24 independent alarms
- SNMPv3 protocol support
- Alarm notifications via SNMP traps
- NTP protocol support
- HTTP API commands
- 4 schedules for real-time control of relay outputs
- Custom logical functions
- Secured email transfer with TLS 1.0, TLS 1.1, and TLS 1.2 support
- Data logging capacity for up to 70,000 records
- Dynamic DNS support for DynDNS, No-IP, and DNS-O-Matic providers
- Periodical HTTP / HTTPS Post of XML / JSON status files for client-server systems
- MODBUS TCP / IP protocol support
- MQTT 3.1.1 protocol support
- Rugged DIN-Rail / wall-mountable enclosure
- Operating temperature range: -20…+55 °C
- For liquids limit level sensing on non-conductive (glass or plastic) gauge-pipes, tubes and tank walls
- Output: switch or PNP
- Sensitivity setting by means of magnetic pen
- LED indication
- Prismatic or planar electrode
- Versions with a fixed cable or a connector
- Supply: 6...30 VDC
- Operating temperature: -20...+80 °C
- Protection class: IP67
- Output: switch
- Application: level sensing for solids
- Supply: 24 VDC / 220 VAC
- Sensitivity setting: 3 positions
- Rotation speed: 1 per minute
- Operating temperature: -20...+70 °C
- Operating pressure: up to 0,8 bar
- Material: body – plastic, other component – stainless steel
- Protection class: IP65
- Weight: 1 kg
- Input: Modbus RTU – RS-485
- Output: 4-channel SPST relay contacts
- Rated relay load: 3 A at 250 Vac; 3 A at 30 Vdc
- Non-volatile memory to retain and restore relay states following power outages
- Watchdog functionality for communication loss
- Operating temperature / humidity: -20…+60 °C / 10…90 % (non-condensing)
- DIN rail mounting
- Power supply: 5…28 Vdc
- Warranty: 3 years
The AUREGIS LJ-VD4M12 multi-zone floating, stainless steel level relay with standard M12 connector is designed for liquid level measurement and regulation.
- Connection connector: M12 (4 / 8 pins)
- Floats and float holders are customizable (on request)
- Connection thread: G3/4" or larger (on request)
- Switching power: 25 VA
- Switching voltage: 24 V AC/DC
- Process part operating temperature: -30...+105 °C
- Process part: Stainless steel AISI316L
- Protection class: IP65
- Grain temperature monitoring system software for PC
- Collects data from temperature cables GWSL 1100 and GWSL 2100 and spear temperature sensors GWTL-R
- Stores, visualizes data in charts
- Alarms
- Level indication
- Pressure range: from -0,9...1,5 to 4...40 bar
- Output signal: 1 Floating change-over contact (SPDT)
- Process temperature: -40...+150 °C
- Process connection: G1/4" f, G1/2" m
- Protection class: IP66
- Pressure range: from 1...10 to 60...600 bar
- Output signal: 1 Floating change-over contact (SPDT)
- Process temperature: -30...+100 °C / -15...+150 °C
- Process connection: G1/4" f, G1/2" m
- Protection class: IP66
- Pressure range: from 0...2,5 to 0...600 bar
- Output signal: 1 or 2 PNP transistors
- Process temperature: -40...+125 °C
- Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
- Protection class: IP65, IP67
- Various pressure measurement ranges: 0,1...1000 bar
- Relay output: 2 units
- Output: 0...20 mA / 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. For direct (up to 63A) and indirect measurement (x/1A or x/5A). Indications considering values of programmed ratios.
- TC Monitor is remote monitoring software that collects data and controls your TCG (GSM) and TCW (Ethernet) Teracom I/O modules
- User-friendly WEB interface for easy configuration and control
- Free version let monitor up to 10 items
- The monitored parameters can be sensors, digital and analog inputs and relay outputs
- Graphical and Data dashboards for better visualization
- TC Monitor allows flexible administration of user accounts
- Easy access to the raw data tables, export in .csv format
- Alarm notifications
- User activities log
- Output relay: SPDT / 3A / 250VAC
- Application: level sensing for solids and powder
- Speed: 1 RPM
- Supply: 24 VDC or 220 VAC
- Operating temperature: - 10...+ 70 °C
- Operating pressure: - 0,6...+ 0,6 bar
- Protection class: IP66
PD9-Modbus RS485 to Ethernet converter can realize bidirectional transparent transmission between RS485 and Ethernet. It carries ARM processor, low power, fast speed, high stability. Via web-page or software, Rs-485 to Ethernet Converter can realize serial data and TCP/IP data package transparent transmission.
- Communication interfaces: 1x RS485, 1x Ethernet WAN/LAN
- Easy configuration the parameters via the webpage or set-up software
- Compact size, DIN rail mount
- Working mode: TCP server, TCP client, UDP server, UDP client
- Modbus RTU to TCP conversion, Modbus Polling
- DHCP support, IP dynamic or static
- Watchdog function
- Working temperature: -40…85°C
- Power supply: 5…36 V dc
- Up to 60 logical channels for data logging (max. up to 8 analog channels)
- Inputs:
- Measuring programmable: 0, 4 or 8
- Binary: 2 or 6
- Modbus RTU Client: 10 devices, 10 registers each
- Outputs:
- Relay: 2, 6 or 8
- Analog 0 / 4...20 mA: 0, 4 or 8
- Supplying output for external devices: 24V d.c. / 30 mA
- Communication interfaces:
- RS-485 MODBUS (Client and Server)
- Ethernet: MODBUS TCP/IP, Webserver (www), FTP
- USB Host 2.0
- Screen: Graphical color display LCD TFT 3.5”
- Internal memory 8 GB for Archiving of measured parameters
- Visualization of measurements in digital form, analog indicators, line charts, bargraphs
- Advanced mathematical functions on measured values
- Archiving and visualization of measuring data transmitted to KD6 from external devices via RS-485 MODBUS
- Settings secured with access password
- PC software for easier setup
- Protection class: IP65 (front)
- Operating temperature: -10...55 °C
- Supply: 85...253 V a.c., 90...300 V d.c. or 20...60 V d.c.
- Ethernet 10/100 Base-T Modbus TCP interface (RJ-45 connector)
- Configurable using webserver
- RS-485 (Modbus RTU Master)
- Distance up to 1200 m, up to 32 modules
- LED indication
- Galvanic isolation in all ways (1500 VAC)
- EMC compliance
- Mounting on DIN rail - EN-50022 compliance
- Ethernet 10/100 Base-T interface
- Modbus TCP server
- Webserver for configuration of device and representation of actual input values
- Galvanic isolation on all the ways (1500 VAC)
- Remotely configured
- LED indication
- EMC compliance
- DIN rail mounting
- Flexible spears for grain temperature measurement
- Rigid construction
- Diameter: Ø8 mm
- Penetration depth: up to 12 m
- Digital temperature sensor
- Measurements are done using PC software or handheld reader GW-200
- Temperature spears and cables can be integrated into single system
- Measures ambient air temperature and humidity
- Integrates seamlessly into GrainWatch PC Software and displays the ambient weather conditions in real-time
TJ-1V sensor is convenient for installation on pipes with staples. For HVAC systems.
- Measurement range: -30...+105 °C
- Sensor type: PT100, PT1000, PTC, NTC, Ni1000, TC K
- Sensor measurement material: brass
- Cable of two or three wires with PVC isolation. Cable length: on request
The TJ-S temperature sensor is permanently connected to a cable and designed for measuring temperatures from -50°C to 400°C.
Various cable lengths are available.
- Sensor type: PT100, PT1000, NTC, Thermocouples K, J
- Measuring range: -50…+400 °C
- Operating temperature:
- -30...+70 °C (PVC isolation)
- -50...+180 °C (Silicone isolation)
- -50...+400 °C, kabelio -50...+250 °C (Teflon isolation)
- -50...+400 °C, kabelio -50...+400 °C (Fiberglass isolation)
- Cable and connection: 2, 3, 4 wire
- Sensor tube:
- Material: Stainless steel 316 (1.4401)
- Diameter: Ø4 mm
- Length: 120 mm
- Temperature sensor TJ1TE – NTC10k3B HVAC developed for air conditioning devices and heating, ventilation, (HVAC) systems
- Measurement range: -30…+105 °C
- Sensor: NTC; Rnom = 10 kΩ at +25 °C; steepness β = 3977 (+25...+85 °C)
- Accuracy: enhanced accuracy ± 0.2 % in range 0...+75 °C, in the rest ± 1 %
- Measuring part housing: PVC; dimensions 4,5 x 90 mm
- Cable of two wire with PVC insulation: standard lengths - 0,1 m; 1,5 m; 3 m; 6 m
- Protection class: IP54
- Fastening with rubber sleeve and / or flange holder according to the drawing (see drawing above)
- Temperature range: from +20...+110 °C iki +40...+300 °C
- Output signal: 1 floating change-over contact
- Process temperature: +20...+300 °C
- Approval: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, RMRS, EN60730-1/ EN60730-2-9: Typ 2.B.H
- Protection class: IP65
- Input: RTD: Pt100 (2-wire) / TC: K
- Output: relay (NC/NO)
- Configuration: via HART (switching point, hysteresis, switching delay, damping), with magnet (switching point)
- Operating temperature: -20...+80 °C
- Supply 24 VDC
- Operates as a temperature switch (thermostat), transducer, data logger
- Accumulated temperature data is read using a mobile phone with NFC interface
- Parametrization via NFC interface
- Display and electrical connection are independently rotatable 335°/343°
- Temperature measurement range: -50...+150 °C
- Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
- Switch output: 2 x PNP
- Sensor: Pt1000 A
- Data logger memory: 3518 measurement points
- Measurement interval: 0,1...999,9 s
- Operating temperature: -25...+85 °C
- Supply: 15...30 VDC
- Flow and temperature sensor for liquids in pipes
- Output: 1 x 4...20 mA, 1 x PNP / 2 x PNP
- Flow measurement range: 1...150 cm/s (water)
- Temperature measurement switching points: 15, 30, 45, 60, 75 °C
- Flow rate measurement is shown in a bar graph by five green LEDs
- Settings provided by magnetic pen
- Stainless steel case
- Supply: 12...34 VDC
- Ambient temperature: -20...+80 °C
- Protection class: IP67 / IP68
The sensor consists of a replaceable insert, a ceramic protective tube (thermowell) and an aluminium connection head (depends on model) where a programmable temperature transmitter with 4-20 mA output can be installed.
- Temperature measuring range: 0… +1800 °C
- Usable areas: Blast furnaces, regenerating air heaters, industrial heating installations, heat generation
- Standard protection tube material: mullite C610 (Al2O3 60%), Ceramic C799 (99.7% Al2O3)
- Gastight process connection: (to 0.1 MPa / 1 bar)
- Optionally the head can be installed with a local temperature display (DANWdie-LED)
- ATEX and EAC Ex versions
- For specific model design please look picture below ↓: TT438, TT440, TT441, TT442, TT443, TT444