  • Temperature measurement range: -20...+60 °C
  • Humidity measurement range: 0...100 %RH
  • Pressure measurement range: 600...1100 hPa
  • CO2 concentration measurement range: 0...5000 ppm
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Internal sensors
  • GSM modem (GPRS)
  • SMS and JSON messages can be sent via GPRS data connection
  • Messages can be sent on alarms and periodically
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate of manufacturer included
  • Ambient temperature: -20...+60 °C
  • Supply: 5200 mAh LiIon battery
  • Protection class: IP20
  • Warranty: 3 years
  • Universal air and environment quality sensor E2-CO2-series measures CO2 (carbon dioxide) level, temperature, humidity, pressure, sound level, ambient light (LUX). Transmits instant values, average hourly values, and average 24-hour values
  • Communication: wM-BUS EN13757-3/4:2013, complies OMS 4.0.2
    • Modes: C1-A/B, T1 or S1 (selectable on order)
  • Measurement ranges
    • Temperature: -40…85 °C
    • Humidity: 0…100 % RH (non-condensing)
    • CO2: 0…5000 ppm (0…55 °C)
    • LUX: 0,01…83000 LUX at same frequency as the human eye
    • Absolute pressure: 20…100 kPa
    • Sound level: 53…90 dBa at 850 Hz
  • Measurement accuracy
    • Temperature: ± 0,2 at +5…+60 °C; ± 0,5 at -20…+85 °C
    • Humidity: ± 2 % RH at 20…80 % RH; ± 3 % RH at 10…90 % RH; ± 3,5 % RH at 0…100 % RH
    • CO2: ± (50 ppm + 3%)
    • LUX: 4 %
    • Pressure:  0,4 kPa
  • CO2 sensor calibrates every 20 days
  • Warnings about low battery, CO2 sensor malfunction, calibration not performed yet
  • Transmission interval: every 90 seconds
  • Measured values sample interval: every 6 minutes
  • LED and sound indication about CO2 exceeded limit
  • Device has 2 antennas for maximum range in both vertical and horizontal directions
  • Power supply: 2 x ER18505 3.6 V Li-SOCI2 battery pack (8200 mAh)
    • Up to 14 years battery lifetime, standard configuration and operating temperature

TSM400-1-TH is a digital temperature and humidity sensor with a 1-Wire interface. Suitable for monitoring air quality of server rooms, data centers, offices and stores.

  • Temperature measurement range: -20…+60°C
    • Accuracy (min): ± 0,4 °C (in -10…+60°C range)
    • Accuracy (max): ± 0,6 °C (in -20…+60°C range)
    • Resolution: 0,1 °C
  • Relative humidity measurement range: 10 to 90% (non-condensing)
    • Accuracy (min): ± 3.0 % RH (in 20…80 % RH range)
    • Accuracy (max): ± 5.0 % RH (in 10…90 % RH range)
    • Resolution: 0,1 %RH
  • Excellent long-term stability
  • The unique 64-Bit serial number for multi-sensors support
  • Ingress protection: IP20
  • Operating voltage range: 4,5…26 VDC
  • Input: 2x thermocouples - J, K, T, N, E, B, R, and S
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…30 Vdc
  • Warranty: 3 years

TCG210-4 is a battery-powered 4G parcel temperature and humidity logger with fallback support for 2G communication. The device is compatible with HTTP/HTTPS API protocols, making it suitable for modern IoT applications. It periodically sends HTTP/HTTPS POST requests to a remote server, containing a status file in JSON format and the most recent logged data in CSV format.

  • Global connectivity - Quad-band 4G LTE Cat.1 with 2G fallback ensures reliable operation worldwide.
  • Battery-powered autonomy - Operates for months without external power, ideal for parcel monitoring and remote applications.
  • Intelligent power management - Advanced sleep mode significantly extends battery life.
  • Flexible configuration - Easy setup via Wi-Fi, SMS, or HTTP API.
  • Real-time alerts - Instant SMS alarm notifications to up to five phone numbers.
  • Integrated sensing - High-accuracy temperature and humidity sensor for critical parcel monitoring.
  • Large data storage - Onboard memory for up to 70,000 logged records.
  • Seamless IoT integration - Periodic HTTP/HTTPS POST with current status in JSON format.
  • Data export - Automatic upload of logged data in CSV format to a remote server.
  • Remote management - Full device control through HTTP API commands.
  • Future-proof - Firmware update over Wi-Fi or 4G LTE keeps the device always up to date.
  • Compact and lightweight - Designed for easy deployment in parcel logistics, cold chain transport, and warehousing.
  • Safe for air transport - Powered by a compliant Li-SOCl₂ battery (IATA DGR, UN 3091, PI970 Section II), suitable for air shipment.
  • Input voltage range: 0…264 Vac or 0…370 Vdc
  • Input frequency: 0…60 Hz
  • Input resistance: >2.4 MOhm
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • True RMS measurement
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…28 Vdc
  • Warranty: 3 years

Adding preset counter Type 886.

  • Display 3- or 5-digit, 4mm
  • Protection class IP30
  • Temperature measurement range: -30...+80 °C
  • Humidity measurement range: 0...100 %
  • Output: RS-485 Modbus RTU
  • Calculates absolute humidity and dew-point temperature
  • Cable length: 2 m / 2 m with M8 connector / 5 m / 10 m
  • Operating temperature: -20...+60 °C
  • Supply: 9...28 VAC/VDC

Ambient humidity and temperature logger TERMIOPLUS-S with external sensor is designed for logging of ambient humidity and temperature in its internal memory.

  • Temperature range: -30...+70°C
    • Temperature accuracy: In range -30...+70 °C: ± 0,3 °C
    • Resolution: 0.1
  • Humidity range: 0...100 % RH
    • Humidity accuracy: ±2 %RH at 25 °C (30…70 %RH); ±3 %RH at 25 °C (10…90 %RH); ±4 %RH at 25 °C (0…100 %RH)
  • Memory: 32000 (16000 temperature and 16000 humidity)
  • USB interface for data download
  • Logging interval: 15 s...10000 min
  • Supply: 2xAA battery, 3.6 V
  • Battery lifetime: 1 one year with 30 min. interval recording at +10 °C
  • Size: 45 x 100 x 19 mm

Antenna radar level meter ARLM-54 designed for reliable level measurement of various liquids and pasty.

  • Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
  • Intelligent numerical signal processing with false reflection elimination
  • Measuring range up to 8 m or up to 20 m
  • Current output - 4...20 mA, HART communication
  • Measurement independent of temperature and pressure of the atmosphere above the surface
  • Possibility to measure even in aggressive vapors
  • Operating temperature: -30…+70 °C
  • Protection class: IP68
  • Antenna radar level meter ARLM-70 "AMANDA" designed for reliable level measurement of various liquids
  • Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
  • FMCW antenna radar level gauge with a range of up to 20 m
  • Teaching function to suppress false reflections
  • Display of measured values on matrix OLED or LCD display
  • Current output - 4...20 mA, HART communication
  • Manual or remote adjustment
  • Measurement independent of temperature and pressure of the atmosphere above the surface
  • Possibility to measure even in aggressive vapours or vacuum
  • Operating temperature: -30…+70 °C

The BDX-30 and BDX-20 is the newest in the legendary “BD Series” pin meters for the building trades. This rugged meter has an ergonomic design with an easy grip handle and large tactile buttons for comfort and usability. Equipped with a custom, LCD display and intuitive user interface, users can quickly obtain accurate readings.

  • Large, custom display with auto backlight - easy to read under all conditions
  • On-screen statistics for up to 100 readings saved to the meter
    • High, Low, Average, Standard Deviation
  • Measuring Range:
    • Wood (Douglas Fir) 6%-60%
    • Drywall 0.1%-6%
    • Reference 1-100
  • Wood temperature correction (°F / °C)
  • Select from 37 wood species and materials
  • Bluetooth® connectivity to EDGE® app (BDX-30)
    • Timestamp and geotag, Data export to .csv format, Save unlimited readings
  • Color-coded LED’s – adjustable through EDGE® app (BDX-30)
  • Alarm set point - alerts to user-selected MC level
  • Internal calibration check
  • "Low Batt" warning with audio
  • Auto off timer. Set to 1m, 4m or 10m
  • Compatible with all Delmhorst electrodes
  • Power: 2x AA Alkaline batteries
  • Temperature Correction Range: 0…255 °F (-18…+124°C)
  • For continuous level measurement of diesel in trucks, building machines, locomotives, etc.
  • Output: 4...20 mA / 0...10 V / CAN
  • Direct mounting into a tank through the 5-hole flange or G1” thread
  • Arbitrary electrode length (up to 1 m)
  • Setting by means of magnetic pen
  • Ambient temperature: 9...30 VDC / 12...30 VDC / 9...30 VDC
  • Protection class: IP68
  • CLM-70 for continuous level measurement of liquids, bulk solids in all industrial branches
  • Stainless steel design suitable for the food and pharmaceutical industries
  • Output: 4...20 mA with two-way HART
  • Process connection: G1”, G1 ½”, NPT 1" threads and Tri-Clamp (Ø 50.5 or 64 mm)
  • Arbitrary electrode length (up to 20 m)
  • Display of measured values on matrix OLED or LCD display
  • Power supply: 18…36 V DC
  • Protection class: IP67
  • For continuous level measurement of liquid and bulk-solid materials
  • Output: 4...20 mA / 0...10 V
  • Universal usage, direct mounting into tanks, vessels, sumps or silos and hoppers
  • Setting using a magnetic pen
  • Possibility of linear measurement even in non-conductive or variously shaped vessels
  • LED indication
  • Versions with coated electrodes for aggressive or electrically conductive media
  • Versions for explosive areas
  • Ambient temperature: -40...85 °C
  • Supply: 9...34 VDC / 12...34 VDC
  • Protection class: IP67 / IP68
  • Detection of various types electrical conductive or non-conductive liquids (water, water solution, cooling liquids, oil, ets.)
  • Direct mounting into various containers, vessels, tanks, ets.
  • Output: S, PNP, NAMUR (for explosive areas)
  • Sensitivity setting by means of magnetic pen
  • High temperature performance, pressure resistance up to 7 MPa
  • Process coupling: thread M18, M20, G3/8“ or 1/2–14 NPT
  • Versions for usage in explosive areas
  • Supply: 6…30 VDC
  • Protection class: IP68
  • Universal use for limit level sensing of liquids and bulk solids
  • Direct mounting into tanks, vessels, sumps and tubes or silos and hoppers
  • Output: NPN, PNP, NAMUR (for explosive areas)
  • Sensitivity and hysteresis fluently adjustable
  • Process coupling: thread M27x2; M30x1.5; G3/4“ or Triclamp
  • Indication by LED
  • Versions for explosive and flammable areas
  • Supply: 7…36 VDC
  • Protection class: IP67
  • Universal use for limit level sensing of liquids and bulk solids.
  • Direct mounting into tanks, vessels, sumps and tubes or silos and hoppers
  • Output: NPN, PNP
  • Setting using a magnetic pen
  • High stability upon high sensitivity (possible to use for materials with εr ≥ 1.3)
  • Indication by two LEDs
  • Versions for explosive areas
  • Supply: 8…9 VDC
  • Protection class: IP67 / IP68

Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.

  • Carbon dioxide (CO2) range: 400...2000 ppm
  • Humidity range: 0...100 % 
  • Temperature range: 0...50 °C
  • Stable long-life optical NDIR gas sensor
    Range 0...10 000/50 000 ppm CO2
    Resolution 1/100 ppm for 10K/50K range CO2​
    Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
    Remote probe option

  • Stable long-life optical NDIR gas sensor
  • Range 400...5 000/10 000/50 000 ppm CO2
  • Resolution 10 ppm CO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • NDIR gas sensor
  • Range: 0...10 000 ppm CO2
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: 0...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC as options
  • Addressable digital gas detection system (Sensor-Board SB) for combustible, toxic and refrigerant gases.
  • Communication: RS-485 interface for stable and secure system networking
  • Precise Detection: High accuracy thanks to digital signal processing
  • Easy maintenance with X-Change: Plug & Play systems for fast, convenient service
  • Robust Design: Reliable with IP65 even under extreme conditions
  • CO2 concentration measurement range: 0...10 000 / 50 000 ppm
  • External sensor cable length 1 / 2 / 4 m
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 10 s...24 h
  • Calibration certificate included
  • LED, acoustic alarms
  • LCD screen
  • Data can be transferred to PC via USB-C interface
  • Operating temperature: -20...+60 °C
  • Supply: battery
  • Protection class: IP54
  • Warranty: 3 years
  • Measures carbon dioxide concentration in air
  • Measurement range: 0...2000 ppm
  • Operating temperature: -30...60 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air
  • Measurement range: 0...10000 ppm
  • Operating temperature: -30...80 °C
  • Cable length: 1 / 2 / 5 / 10 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air
  • Duct mount
  • Measurement range: 0...2000 ppm
  • Operating temperature: -30...60 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air, temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: 0...2000 ppm, -30...+80 °C, 5...95 %RH
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s; CO2: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air, temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: 0...10000 ppm, -30...+105 °C, 5...95 %RH
  • Temperature and humidity sensor cable length: 1 / 2 / 4 m
  • Carbon dioxide concentration sensor cable length: 1  2 / 5 / 10 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s; CO2: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included

Temperatre, humidity and pressure meters, loggers Cxxxx, Dxxxx.
Cxxxx are designed for indication (without data logging), Dxxxx indicates and logs listed parameters.

TSH202B is a compact humidity and temperature sensor with 1-Wire interface. It is ideal for use in a variety of applications where space is limited, such as environmental monitoring systems, HVAC control, and more.

  • Fully calibrated digital output
  • Excellent long-term stability
  • A unique 64-bit serial number for multi-sensor systems
  • 3.0% relative humidity accuracy
  • 12-bit resolution for humidity measurements
  • 14-bit resolution for temperature measurements
  • Flow monitors for water and air flows
  • Robust stainless steel sensor housing for industrial environments
  • Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
  • Switching point sensitive and continuously adjustable both for liquids (0.03 ... 3 m/s) and for gases (0.5 ... 20 m/s)
  • With switching output (1 NO/ 1 NC)
  • Exemplary areas of application: Monitoring of air and water flows, cooling circuits up to 30% glycol content, pump monitoring
  • Warning- and Sensor-Board WSB for digital and analog sensor technology for the precise detection of combustible, toxic and refrigerant gases.
  • Versatile alarm function: Alarm and fault relays (30 V)
  • Intelligent interfaces: RS-485 interface with DGC or Modbus protocol
  • Precise signal transmission: 4–20 mA input and output for reliable communication
  • Flexible: Connection of up to 3 sensors (2 digital)
Microprocessor controller INDU-30 with RS-485 interface for temperature and humidity control in food and other industries. The device is designed for temperature and humidity control in food and other industries (drying, climate chambers, etc.). Humidity measurement is done via psychorometer method. Two programmable inputs are used for temperature sensor connection and one for standard signal 0/4...20 mA. Version for work with thermocouples is also available. The device can log measured values in set time intervals. Data is transferred via RS-485 interface. Control starts in set t..
Microprocessor controller INDU-50 with RS-485 interface for temperature control in thermal processing devices in food industry. The device is intended to be us in boiling pots, vaporizers, grills, climate chambers and so on. Measured values can be logged into the internal memory. Data is transferred via RS-485 interface. Real time clock. Control starts in set time or after set delay. Technical specifications Input: 2 analogue inputs PT-100 (PT-500, PT1000) channel 1: temperature – ‘dry’ thermometer channel 3: temperature – ‘we..
  • The MQTT protocol is ideal for communication in distributed acquisition systems data (IoT applications)
  • Especially suitable for server rooms, pharmaceutical and food warehouses, laboratories, museums and greenhouses
  • Logged data is stored in the internal memory and then sent digitally to the user (over Ethernet)
  • Alarms are formed by e-mails, on the webserver, using symbols on screen or via audible alarms
  • HT20IoT can be powered by the Ethernet network (PoE – Power over Ethernet), additionally ordered
  • FTP, DHCP, SMT, Modbus TCP/IP protocols
Temperature and humidity mini data loggers SL5x. Operating temperature from -40°C to +140°C, designed for temperature measurements or temperature and humidity measurements logging. Due to small size (Ø17x6 mm) these data loggers can easily be fit in small objects and packages. ♦ Compact size♦ Sturdy and reliable construction♦ Wide range of accessories♦ Free software♦ Data export function♦ Cold supply chain assurance while transporting and storing pharmaceuticals and biotechnological products, chemicals and food products which require special transport and stora..
  • Triton Vape Detector of vaped and burn nicotine, THC, and other substances. Does not differentiate the substances
  • Monitoring of Humidity, Particulate Matter Index and VOC Index
  • Rejects most aerosols with a similar profile to vape/smoking
  • Alert Options: SMS Text Message, Email, App, Notification, 3rd Party Integration, Audible Alarm
  • Tamper protection: Device Vandalism, Device Disconnect, Masking and Sensor Cover, Ultra-loud alarm to dissuade tampering
  • Integrations: Integrates with numerous 3rd party video management systems to give context to alerts through automatic camera recording
  • Manage devices through the Triton Sync online dashboard and app in Cloud. Real-time monitoring and customizable alerts
  • Operating environment Temperature / Humidity: 0…40 °C / 0…90 % RH (non-condensing)
  • Power Supply PoE (IEEE 802.3af Class 3 Compliance) 9W 48V
  • With display and operation via keys, three display pages for temperature humidity and other parameters to show
  • 4...20 mA analogue output, alarm relay connection, Modbus-RTU (RS-485)
  • Extreme long-term stability, quick response time
  • Sensor diagnostic with CS service software
  • Suitable to measurement in granulate dryers, compressed refrigerating gases 
  • Extreme long-term stability, quick response time
  • Sensor diagnostic with CS service software
  • 4...20 mA analogue output, Modbus-RTU (RS-485)
  • Suitable to measurement residual moisture, dew point after granulate driers in plastic industry and various gases
  • To measure air and neutral gases pressure in range -100...100 Pa
  • Solenoid valve for auto-calibration: frequency 1…60 min
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -100...100 Pa
  • Accuracy: ± 1 % of reading ± 2 Pa
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output: 0-10 V and 4-20 mA
  • Overpressure tolerated: 21 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply: 24 V AC / V DC
  • To measure air and neutral gases pressure in range -1000...1000 Pa
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -1000...1000 Pa
  • Accuracy: ± 1.5 % of reading ± 3 Pa
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA: 4-20 mA
  • Overpressure tolerated: 21 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
  • To measure air and neutral gases pressure in range -2000...2000 mbar
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -2000...2000 mbar
  • Accuracy: ± 1.5 % of reading ± 3 mbar
  • Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
  • Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 4100 mbar
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
  • To measure air and neutral gases pressure in range -500...500 mbar
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -500...500 mbar
  • Accuracy: ± 1.5 % of reading ± 3 mbar
  • Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
  • Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 1400 mbar
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
  • RS-485 (Modbus) protocol temperature and humidity sensor
  • Temperature measurement range: -20...+60 °C
  • Humidity temperature range: 5...95 %RH
  • Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (5...95 %RH) / ±0,4 °C (-10...+60 °C) / ±0,6 °C (-20...+60 °C)
  • Resolution: 12 bits for temperature and humidity
  • Long-term stability
  • Warranty: 3 years
  • 1-Wire protocol temperature and humidity sensor
  • Temperature measurement range: -20...+60 °C
  • Humidity temperature range: 10...90 %RH
  • Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (10...90 %RH) / ±0,4 °C (-10...+60 °C) / ±1 °C (-20...+60 °C)
  • Resolution: 14 bits for temperature, 12 bits for humidity
  • Long-term stability
  • Warranty: 3 years
  • RS-485 protocol temperature and humidity sensor
  • Temperature measurement range: -20...+60 °C
  • Humidity temperature range: 5...95 %RH
  • Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (5...95 %RH) / ±0,4 °C (-10...+60 °C) / ±0,6 °C (-20...+60 °C)
  • Resolution: 14 bits for temperature, 12 bits for humidity
  • Long-term stability
  • Warranty: 3 years
  • Connection: RJ-45

 

  • Outputs 0...10 V, 0...20 mA
  • Display LED 4 digits, 14 mm height

 

  • Output 0...20 mA
  • Display LED 4 digits, 14 mm height
  • 1-Wire protocol temperature sensor
  • Temperature measurement range: -40...+85 °C
  • Accuracy: ±0,5 °C (-10...+85 °C) / ±2 °C (-40...+85 °C)
  • Resolution: 12 bits
  • Very low current consumption
  • Warranty: 3 years
  • Protection class: IP65
Loading...