  • TOR-80 is designed to measure the dielectric strength of transformer oil and other dielectric fluids according to IEC 60156, ASTM D877 and ASTM D1816
  • Can work autonomously or transfer results to a PC, create a local database, generate reports, plot graphs and print results
  • There is software for the implementation of standard and custom measurement procedures
  • Max output voltage: up to 80 kV, sinusoidal
  • Output voltage measurement accuracy ± 2 %
    • Voltage increase rate: 0,1 to 5 kV/sec (adjustable)
    • Resolution of output voltage indication: 100 V
    • High voltage timeout after breakthrough: 4 ms typical (10 ms max)
  • Operating voltage:  85 – 264 V a.c. (48…63 Hz)
    • Power requirement: 250 VA max
  • Measuring cell volume for oil: 500 cm3
    • Temperature range of testing oil: 0…100 °C
  • Unit operating conditions:
    • Temperature: 0…50 °С
    • Storage temperature: -20… 60 °С
    • Relative humidity: Up to 90 % (without condensation)
  • Modern, simple and user-friendly service
  • Communication interfaces: RS-485 Modbus Slave, Modbus TCP Slave and optionally Ethernet
  • FTP server (available in controller versions with Ethernet interface)
  • Selection of PID parameters for any unit
  • For easy programming and devices configuration, LUMEL offers one common LPCon software
  • Parameter logging on SD card
  • Universal measuring inputs, it can be used for controlling of temperature (RTD, thermocouple) and other physical values
  • Colored TFT display presentation of measured values (numerical values, bar graph, meter, graph)
  • Control algorithms On-Off; PID; 12 segmental adjustment program
  • Interfaces: USB, RS485 (MODBUS-RTU) and Ethernet (100Base-T, TCP / IP protocols: Modbus-TCP, HTTP, SMTP)
  • Internal webserver, information about the active channel, measuring parameters and the status of the regulation, requires access
  • Available alarm sound and visual, status outputs and alarm notification e-mail
  • Write data in a standard text file located in the internal controller memory (4GB) FAT with the possibility of editing in spreadsheets such as Microsoft Excel
  • Selection of PID parameters for each output
  • The possibility of creating inter-channel type mathematical and logical operations: the difference, average, sum, bigger, smaller measurement
  • Function digital inputs (BIN) to changes modes associated outputs, retransmission of measurements
  • Free software for data processing and device programming
  • Controller is destined to control the temperature and other physical quantities like pressure, humidity, level
  • Three optional outputs (0/4...20 mA ± 0,2 %, 0...10 V ± 0,2 %, 0/5 V, relay voltage output)
  • Universal input for RTDs, thermocouples and analog signals
  • Configuration parameters via keys or an optional RS-485 Modbus and free eCon software
  • The controller has three alarms, which can be assigned to each output
  • The output signals are galvanic isolated from the input signals and power supply
  • Selection of PID parameters for any unit, or auto-tuning
  • Protection class from frontal side: IP30, from terminal side: IP20
  • Capacitive moisture measurement
  • Up to 16 sensors per signal processing unit
  • Temperature range of measuring material: 4...80 °C
  • Measured value transfer: Profibus DP or analogue standard signal (e.g. 4...20 mA) optional
  • Continuous measurement or batch operation

These jacket heaters enable the comfortable and effective way to heat up IBC containers and other tanks. Low energy losses, even heat distribution. Can be used for various products: water, oils, diesel fuel, resin, Vaseline, wax, lanolin, fats, butters, Ghee, glue and adhesive. Can be used with insulation lid.

  • 1, 2, or 3 thermostats adjustable from 0…+90 °C
  • Teflon coated Polyester Material
  • Standard size IBC 1000L (4400 x 1000 mm)
  • Durable, lightweight design with quick release buckles
  • 3 m connection cable
  • Protection class IP40 (Optional IP54)
  • Warm-up duration approx. 48h (1000L drum with water starting from +15º C to +50º C with 2x1000 W heaters and isolation lid)
  • Warm-up duration approx. 48h (1000L drum with water starting from +15º C to +70º C with 3x1000 W heaters and isolation lid)