Linear encoder MLS210. With spiral connection.
Technical specifications
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS110. With cable connection.
Technical specifications
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS110. With spiral connection.
Technical specifications
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS120.
Technical specifications
- Casing integrated into slider
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS130. Very small size.
Technical specifications
- Very small measuring head (in metal enclosure)
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS210. With spiral connection and slider joints.
Technical specifications
- Protection class IP67
- Twin sliders
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
- 4 analog inputs (standard signals, RTD, thermocouple)
- RS-485 Modbus output (Slave mode)
- 2 alarm outputs
- Galvanic isolation of inputs (2 from other 2)
- Programmable individual characteristics, mathematical functions
- Programmable time counters
- Rail-mounted
- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- Pressure measurement range: 600...1100 hPa
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
Data logger (recorder) AR207 is designed for temperature, standard DC voltage and current and pulse signal logging. 16/8 programmable channels. 4 programmable (NO or SSR) outputs for control and alarm. Color LCD TFT screen. Ethernet (web server function). Internal memory card which can be expanded using USB flash drive. Panel mounting. Multi-channel data presentation. Internal real time clock (RTC). Programming and data access protection.
- Fully functional data logger
- Two-line digital LCD display
- 4 control buttons
- 32 alarm LEDs
System of data logging MS6D, MS6R (Comet System, Czech Republic). For mounting to 19" rack - one rack unit 1U. The device can be integrated into the MP033, MP034 waterproof housing. With backlight display, 4 control buttons (for configuration), 32 LED for alarm.
- Universal datalogger with 4 hardware MiniDIN inputs for connecting temperature and humidity probes.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 hardware MiniDIN inputs for thermocouples K, J, S, B, T, N.
- Cold junction compensation (CJC).
- Sensors of physical quantities with bipolar voltage output can also be connected. Two voltage ranges: -18...+18 mV and -60...+140 mV.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Thermocouples are ordered separately.
- Open collector transistor alarm output.
- Universal datalogger with 4 hardware MiniDIN inputs, 2 for thermocouples K, J, S, B, T, N and 2 for connecting temperature and humidity probes.
- Cold junction compensation (CJC).
- Sensors of physical quantities with bipolar voltage output can also be connected. Two voltage ranges: -18...+18 mV and -60...+140 mV.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures barometric pressure using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures carbon dioxide (CO2) using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
- Ambient temperature and humidity transducer with 4...20 mA output
- Stem length 700 mm
- Calculated values: dew point temperature, absolute humidity, specific humidity, mixing ration, specific enthalpy
- Display with two periodically changed shown values (can be switched off)
- Integrated sensors
- Calibration certificate is included
- Programmable output
- Low temperature inertia
- For use in non-aggressive environment
- 3 year warranty
- To measure and data logging: carbon dioxide (0...5000 ppm), temperature (0...50 °C), atmospheric pressure (800...1100 hPa), humidity (0…100 % RH) in air and neutral gases
- Free software for configuration and data visualization
- Bluetooth communication for smartphones and tablets (Android and IOS)
- Safety lock magnetic mounting with inviolability system holder (accessories)
- Compatible with food industry environment
- Up to 4 recordable parameters simultaneously
- Optional calibration certificate
- Data visualization in WWW server
- Convenient login from various devices (PC, tablet, phone)
- Readout of up to 2500 values of slave devices (up to 100 devices, 25 registers each)
- 1 GB Flash memory
- E-mail messages in case of alarm occurrence
- 2 alarm outputs or 2 binary inputs
- RS-232, RS-485, USB, Ethernet, RTC
Pneumatic valve 290 (Asco).
- Great permeability due to angular construction
- Does not produce hydraulic shocks
- Can operate in vacuum (up to 10-2 mbar)
- Reliable and lasting stem seal
Special versions and additional equipment:
- Valve completely made out of stainless steel AISI 3156L
- Valve with welded ends or ISO 2852 connection for food industry
- Back contacts, process limiters
- Solenoid distributors
- Special versions for oxygen, Ex zone
- PD51-A transducer/repeater, designed for conversion of RS232 interface to industrial RS485
- This enables to increase device number in the system and extend its range
- Measures air temperature, humidity
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...+80 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
- Measures air temperature, humidity in ducts
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...105 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- External sensor cable length: 1 / 2 / 4 m
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
- Measures air temperature, humidity in ducts
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...125 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
- Ambient temperature and humidity transducer with 4...20 mA output
- Integrated sensors
- Calibration certificate is included
- Economical
- To measure carbon dioxide in air and neutral gases range 0…5000 ppm
- Configuration with switches or software: measuring ranges, outputs settings
- Optional with display or without display
- Ambient and duct models. Duct model available only without display
- To measure carbon dioxide and temperature in air and neutral gases ranges 0…5000 ppm, 0...50 °C
- Configuration with keypad or software: measuring ranges, units, outputs settings
- Optional with display or without display
- Galvanic isolation all the ways
- On request range increase up to 0...20 000 ppm
- For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
- Default calibration R-404a
- Long-life MOS sensor
- Range 0...1000 ppm
- Resolution 1 ppm
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
The unit is designed for determining dielectric loss tangent and permittivity of transformer oils and other dielectric fluids according to the IEC 60247.
It is a fully automatic device that allows testing according to the procedures defined in these standards, as well as according to the user procedures specified in the appropriate section of the setup menu.
- Applied measuring voltage: 500…2000 V a.c. sinusoidal
- Tan δ measurement range: 0,00001…1
- Tan δ measurement resolution: 1х10-5
- Tan δ measurement accuracy: ± 1 % of measurement + 0,00008
- Measurement range of relative dielectric constant ε: 1,0…15,0
- Accuracy of ε measurement: ± 1 %
- Oil temperature measurement range: 20…110 ᴼС
- Measuring cell volume: 42 cm³
- Power supply: 85...264 V a.c. (48…63 Hz)
Programmable pulse counter P30O, designed to convert frequency, pulse, input period, time and revolution speed signals into standard voltage or current signals. The device is programmed via PC (RS-485 interface) or with buttons.
Main properties:
- 2 universal pulse inputs
- Mathematical functions for every input
- Individual output characteristic (up to 21 point)
- Option – internal transducer supply source 24 VDC, 30 mA
- RS-485 interface (protocols Modbus RTU Slave, Modbus TCP Slave)
- Data logging function (internal 4 MB memory or SD/SDHC card (up to 8 GB))
Fluid level alarm Elcluwo 111S, designed for usage with conductometric probes for fluid level alarm and control.
Technical specifications
- One or more level control
- Switch output 2A, 250 VAC
- Probe supply from isolated ~12 V source
- Adjustable sensitivity
- Available modes – flooding, drainage, dry flow, overflooding
- Pump or valve control
- Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
- Mounting on standard rail (35 mm)
Fluid level alarm Elcluwo 112S, designed for usage with conductometric probes for fluid level alarm and control, depth pump protection.
Technical specifications
- One or more level control
- Switch outputs: switching + NO 2 A / 250 VAC
- Probe supply from isolated ~12 V source
- Adjustable sensitivity
- Available modes – flooding, drainage, dry flow, overflooding
- Pump or valve control
- Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
- Mounting on standard rail (35 mm)
- One or more level control
- Switch outputs: switching + 3 x NO 2 A / 250 VAC
- Probes: galvanically isolated, max. 2mA, 5V~ 100 Hz
- Adjustable sensitivity
- Available modes – flooding, drainage, dry flow, overflooding
- Pump or valve control
- Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
- Mounting on standard rail (35 mm)
- Supply: 230 VAC / 24 VAC
- One or two level control
- Switch outputs – switching + 5 x NO, 2A / 250 VAC
- Probes: galvanically isolated, max. 2uA, 5V~ 100 Hz
- Adjustable sensitivity
- Available modes – filling, draining, dry flow, overflow, two/three pump control and others
- Valve or gate control
- Adapted for work with various probes – SKS 401, 201, 101, SW-01 and others
- Mounted on standard rail (35 mm)
- Supply: 230 VAC / 24 VAC
- Measurement distance: 0,5…2 m
- Accuracy: ± 0,5 °C
- Measurement speed: 0,7…2 m
- Software: DERMALOG Fever Detection (PC required)
- Interface: USB 3.0
- SDK: .Net / C / C++ / (Java coming soon)
- Measurement speed: 0,6 s (up to 700 people per hour)
- Integrated sensors: 5
- IR thermal array, range: 0...100 °C (± 0,3 °C)
- Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
- Relative humidity sensor, range: 0...100 % (± 3 %)
- Vibration sensor (for sabotage detection), range: 0,25...5 G
- Distance sensor, resolution: 1 mm
- Dew point calculation
- Relay inputs: 2
- Relay outputs: 2
- LED indication, buzzer (85 dB)
- Communication: Ethernet (10/100)
- Connector (RJ45) for connection of other Kentix devices
- Webserver
- Software: remote connection with AlarmManager-PRO
- E-mail, SNMP alarms, Rest API
- SD card slot (to save pictures, card up to 128 GB)
- PoE
- Optional: RFID reader
- Optional: wall bracket, cable
2-channel binary input converter SM3 with RS-485/232 interface. Modbus RTU and ASCII.
8 binary output converter SM4 with RS-485/232 interface. Modbus RTU and ASCII.
8-channel binary input converter SM5 with RS-485/232 interface. Modbus RTU and ASCII.
Solenoid valve SCG238 (Asco).
- Normally closed, does not produce hydraulic shocks, pilot
- Solenoid valve complies to all associated EC directives
- For hot and cold water (on/off function)
- Self-cleaning breather guarantees reliable function
Counter ALC77-C for linear and rotary encoders (up/down).
Technical specifications
- 600 kHz input frequency
- Encoder input (A and B signals)
- 7-digit LED screen
- Range -999...9999
- 2 programmable set points (SPs)
- 2 switch outputs + RS-232
- Protection class IP65
- Supply 24 VAC/VDC or 230 VAC
- Sensor supply 5 VDC or 12 VDC
- Size 72 x 72 mm
Counter ALC77-T for linear and rotary encoders (for tachometers).
Technical specifications
- 5 kHz input frequency
- Encoder input (A and B signals)
- 7-digit LED screen
- Range -999...9999
- 2 programmable set points (SPs)
- 2 switch outputs
- Protection class IP65
- Supply 24 VAC/VDC or 230 VAC
- Sensor supply 5 VDC or 12 VDC
- Size 72 x 72 mm
Counter ALC77-B for linear and rotary encoders (batch).
Technical specifications
- 10 kHz input frequency
- Encoder input (A and B signals)
- 7-digit LED screen
- Range -999...9999
- 2 programmable set points (SPs)
- 2 switch outputs
- Protection class IP65
- Supply 24 VAC/VDC or 230 VAC
- Sensor supply 5 VDC or 12 VDC
- Size 72 x 72 mm
Counter ALC94UNI for linear and rotary encoders (up/down), universal.
Technical specifications
- 600 kHz input frequency
- Encoder input
- 6-digit LED screen
- Range -99999...999999
- 2 programmable set points (SPs)
- 2 switch outputs OR RS-232
- Protection class IP65
- Supply 24 VAC/VDC or 230 VAC
- Sensor supply 5 VDC or 12 VDC
- Size 96 x 48 mm
- Wide temperature range: -10...+1200 °C
- 320 x 240 and 640 x 480 infrared resolution
- 9 or 60 Hz models available
- Sighting: IR-Fusion technology (thermal and visible sighting) for easy alignment and added detail on blended images
- Remote motorized focus
- Multiple field interchangeable lens options available
- GigE Vision interface
- LAN/Ethernet with PoE for communication with the thermal imager provides access to Ethernet, Web server and ThermoView Software
- I/O alarming capabilities
- ThermoView software for industrial automation applications
- Ambient temperatures to 200 °C with high temperature enclosure
- Air purge and accessories available
- Rugged housing, IP67 rated
- Measurement range: -40…+180 °C
- Type: J / K / N / T / E
- Self-adhesive tape
- Thermocouple tolerance (accuracy), cable length and insulation can be chosen by demand (see datasheet)
- Optional: temperature transducer (4...20 mA / 0...10 V / HART / Profibus PA / Fieldbus)
- Optional: connector
- Indoor temperature controller of TR series (S+S Regeltechnik, Germany)
- TR-040 (external setting): 0...40 °C
- TR-040U (internal setting): 0...40 °C
- TR-060 (external setting): 0...60 °C
- TR-060U (internal setting): 0...60 °C
- Output: Relay
- Switching capacity: 24...250 VAC (16 A)
- Ambient temperature: -35...65 °C
- Protection class: IP65