This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Search

Search Criteria

Products meeting the search criteria

Show:
Sort By:

TSV202-60 ideal for monitoring battery banks, solar panels, industrial control circuits, and other high-voltage applications.

  • Dual channel input: 0…60 V
  • Communication interface: 1-Wire protocol
  • Accuracy: ±1%
  • Resolution: 0.001V
  • Galvanic isolation between the voltage circuit and 1-Wire bus
  • Operating environment: -20…+60 °C / 10…90 %RH
  • Warranty: 3 years
  • Dual channel input: 0…24 mA or 0…10 V
  • Communication interface: 1-Wire protocol
  • Accuracy: ±1 %
  • Resolution: 0.001mA / 0.001 V
  • Galvanic isolation between the current circuit and 1-Wire bus
  • Detection of special states such as sensor errors or calibration values
  • Operating environment: -20…+60 °C / 10…90 %RH
  • Warranty: 3 years
  • 1-Wire protocol current transmitter
  • Current measurement range: 0,3...15 A (AC / DC, set by jumper)
  • Resolution: 10 bits
  • Galvanic isolation between the current circuit and 1-Wire bus
  • Excellent long-term stability
  • Warranty: 3 years
  • Connection: RJ-11
  • Input: Pt100 (2-, 3-, 4-wire)
  • Measurement range: -200...+850 °C
  • Resolution: 24 bits
  • Very low current consumption
  • No external power supply needed
  • Warranty: 3 years
  • Connection: RJ-11
  • Input: 2x thermocouples - J, K, T, N, E, B, R, and S
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…30 Vdc
  • Warranty: 3 years
  • Air velocity measurement range: 0...2 / 0...10 / 0...20 m/s (selectable via jumper)
  • Temperature measurement range: 0...50 °C
  • Output: 0...10 V / 4...20 mA
  • Option: LCD screen
  • Option: relay output
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...+50°C
  • Protection class: IP54
  • Maximal pressure measurement range: 0...1000/2000/5000/7000 Pa
  • Air flow and velocity measurement
  • Output: 0...10 V / 2...10 V or 4...20 mA
  • Option: autozero function and LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 10...35 VDC
  • Operating temperature: -40...+50°C (see datasheet)
  • Protection class: IP54
  • Temperature measurement range: -30...+80 °C
  • Humidity measurement range: 0...100 %
  • Output: RS-485 Modbus RTU
  • Calculates absolute humidity and dew-point temperature
  • Cable length: 2 m / 2 m with M8 connector / 5 m / 10 m
  • Operating temperature: -20...+60 °C
  • Supply: 9...28 VAC/VDC
  • Ambient temperature and humidity transducer with 4...20 mA output
  • Integrated sensors
  • Calibration certificate is included
  • Economical
  • Ambient temperature and humidity transducer with 4...20 mA output
  • Stem length 700 mm
  • Calculated values: dew point temperature, absolute humidity, specific humidity, mixing ration, specific enthalpy
  • Display with two periodically changed shown values (can be switched off)
  • Integrated sensors
  • Calibration certificate is included
  • Programmable output
  • Low temperature inertia
  • For use in non-aggressive environment
  • 3 year warranty

Carbon dioxide (CO2) and temperature transmitter with a display CDT2000 Duct. The device is designed for measurement of air parameters in ventilation channels.

  • CO2 range 400...2000 ppm
  • Temperature range 0...50 °C
  • To measure carbon dioxide and temperature in air and neutral gases ranges 0…5000 ppm, 0...50 °C
  • Configuration with keypad or software: measuring ranges, units, outputs settings
  • Optional with display or without display
  • Galvanic isolation all the ways
  • On request range increase up to 0...20 000 ppm

 

  • To measure carbon dioxide in air and neutral gases range 0…5000 ppm
  • Configuration with switches or software: measuring ranges, outputs settings
  • Optional with display or without display
  • Ambient and duct models. Duct model available only without display

Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.

  • Carbon dioxide (CO2) range: 400...2000 ppm
  • Humidity range: 0...100 % 
  • Temperature range: 0...50 °C

Carbon dioxide transmitter CMT is designed for CO concentration measurement. The transmitter is used to control interior ventilation systems.

  • CO range 0...300 ppm
  • CO2 concentration measurement range: 0...10 000 ppm
  • Output: 4...20 mA
  • Programmable
  • External probe cable length: 1 / 2 / 4 m
  • LCD display
  • Calibration certificate included
  • Ambient temperature: -30...+80 °C
  • Supply: 9...30 VDC
  • Protection class: IP65
  • Warranty: 3 years
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
  • Relay output: 2 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Temperature input: none / Pt100 / Pt1000 / thermocouple
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
  • Relay output: 3 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA (optional: double output)
  • Relay output: 4 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • Current (AC / DC) transducer T23CT with 4...20 mA output
  • AC/DC current input (single option): up to 50 / 100 / 150 / 200 / 300 A
  • Optional mounting on DIN rail
  • Galvanic isolation
  • Supply: 24 VDC
  • Ambient temperature: -25...+55 °C
  • Protection class: IP65, IP40 for terminals
  • To measure air and neutral gases pressure in range -10 000...10 000 Pa
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -10 000...10 000 Pa
  • Accuracy: ± 1.5 % of reading ± 3 mmH2O
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output (Optional):0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 69 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
  • To measure air and neutral gases pressure in range -100...100 Pa
  • Solenoid valve for auto-calibration: frequency 1…60 min
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -100...100 Pa
  • Accuracy: ± 1 % of reading ± 2 Pa
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output: 0-10 V and 4-20 mA
  • Overpressure tolerated: 21 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply: 24 V AC / V DC
  • To measure air and neutral gases pressure in range -1000...1000 Pa
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -1000...1000 Pa
  • Accuracy: ± 1.5 % of reading ± 3 Pa
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA: 4-20 mA
  • Overpressure tolerated: 21 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
  • To measure air and neutral gases pressure in range -2000...2000 mbar
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -2000...2000 mbar
  • Accuracy: ± 1.5 % of reading ± 3 mbar
  • Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
  • Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 4100 mbar
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
  • To measure air and neutral gases pressure in range -500...500 mbar
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -500...500 mbar
  • Accuracy: ± 1.5 % of reading ± 3 mbar
  • Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
  • Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 1400 mbar
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
  • PID controller
  • 2 set points (SP), chosen by binary input
  • Pressure measurement range: -250...2500 Pa
  • Output: 0...10 V
  • Input: NTC10, NTC20, Pt1000, Ni1000
  • LCD screen
  • Temperature compensation
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • Maximal pressure measurement range: 0...2500 Pa
  • 8 field selectable measurement ranges (via jumper)
  • Output: 4...20 mA
  • Option: LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 10...35 VDC
  • Operating temperature: -10...+50°C
  • Protection class: IP54
  • Two pressure transmitters in one device
  • Pressure measurement range: -250...2500 / -250...7000 Pa
  • Option: DPT-DUAL-MOD-AHU – with air flow transmitter
  • Output: Modbus RTU
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • Pressure measurement range: -250...2500 / -250...7000 Pa
  • Input: 2 x  0...10 V, NTC10k, Pt1000, Ni1000, binary
  • Output: Modbus RTU
  • Temperature compensation in range of 0...50 °C
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+50°C
  • Protection class: IP54

Differential pressure transmitter with Modbus interface DPT-MOD-2000, DPT-MOD-3000 and DPT-MOD-5000 for usage in air and non-aggressive gasses.

Differential 8 range pressure transmitter DPT250, DPT2500 and DPT7000. Designed for usage in air and non-aggressive gasses.

  • Pressure measurement range: from 0...1 bar to 0...6 bar
  • Made to be used for air-conditioning, heating and water systems
  • For neutral fluids and non-aggressive gases, compatible with refrigerants
  • Output: 4...20 mA
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+80°C
  • Protection class: IP65
  • Input: differential pressure
  • Typical areas of use are chemical industry and process engineering
  • Measurement range: 75 mbar...70 bar
  • Output: 4...20 mA HART
  • Supply: 12...30 VDC
  • Operating temperature: -40…+85 °C
  • Protection class: IP65
  • Process connection: 1/4-18NPT
  • Pressure range: from 0...1 to 0...16 bar
  • Output signal: 4 ... 20 mA (P1–P2)
  • Process temperature: -25...+125 °C
  • Process connection: G1/4" f
  • Protection class: min. IP65
  • PID controller
  • Pressure measurement range: 0...2500 Pa / 0...7000 Pa
  • Switchable between air flow and pressure measurement
  • Output: 0...10 V / 4...20 mA
  • Option: autozero function
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • PID controller
  • Pressure measurement range: 0...2500 Pa
  • Modbus RTU communication
  • Control output: 0...10 V
  • External input: 0...10 V / thermistor / binary
  • LCD display
  • Temperature compensation
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC
  • Operating temperature: -20...+50°C
  • Protection class: IP54

Duct temperature transducer with 4...20 mA output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Calibration certificate is included.

Duct temperature transducer with 0...10 V output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Output temperature range is user adjustable. Calibration certificate is included.

The FPI 8237 IO-Link Flush Membrane pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel 1.4462. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.

  • Measuring range: -0,5...0,5 to 0...100 bar
  • Output signal: IO-Link 1.1, COM3, min. process cycle time 1 ms, Smart Sensor Profile ED2, 2 Switching outputs PNP / NPN / Push-Pull configurable
  • Accuracy at 25°C typically: ± 0.5 % FS typ.
  • Measuring principle: Thin-film-on-steel
  • Media temperature –10... +125 °C
  • Ambient temperature: –10...+125 °C
  • Protection class: IP65, IP67
  • Applications: Hydraulics, Machine tools, Process technology, Food industry, Water treatment

The FPT 8236 pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.

  • Measuring range: 0.5...0.5 to 0...100 bar (-5...10 to 0...1500 psi)
  • Output signal: 4...20 mA, 0...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
  • Accuracy at 25°C typically: ± 0.5 % FS typ.
  • Membrane in Duplex steel 1.4462
  • Pressure connection: G1/2” male, flush membrane
  • Media temperature –10... +125 °C
  • Ambient temperature: –10...+125 °C
  • Applications: Machine tools, Food Industry, Process technology, Water treatment, Hydraulics
  • Temperature measurement range: 0...50 °C
  • Humidity measurement range: 0...100 %
  • Output: 2 x 0...10 V / 2...10 V / 4...20 mA
  • Option: LCD display
  • Option: relay output
  • Option: Modbus RTU
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...50 °C
  • Protection class: IP20
  • Temperature measurement range: 0...50 °C
  • Humidity measurement range: 0...100 %
  • Output: 2 x 0/2...5/10 VDC
  • Option: LCD display
  • Option: Modbus RTU
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...50 °C
  • Protection class: IP54
  • Temperature measurement range:
    a) Ambient model: -20...+80 °C
    b) Remote model with polycarbonate probe: -20...+80 °C
    c) Remote model with stainless steel probe: -40...180 °C
  • Relative humidity measurement range: 0...100 %
  • Calculates dew point, absolute humidity, enthalpy and combination ratio
  • 4-wire analog output: 0...5/10 V or 0/4...20 mA
  • 2 relay outputs
  • Versions with or without display
  • Protection class: IP65 (ABS V0 housing)
  • Hydrogen pressure transmitter’s measuring principle: Thin-film-on-steel
  • EC79 and ECER-134 certification pending (see product website for current situation)
  • Applications: Fuel cells, fueling stations, hydrogen compressors, hydrogen tanks, vehicles with H drive
  • Measuring range: 0…1050 bar / 0…15000 psi *(see product datasheet)
  • Measuring accuracy at 25 °C typ.: ± 0.3 / 0.5 % FS typ.
  • Output signal: 4...20 mA, 0.5...4.5 VDC, 0...5 VDC, 1...5 VDC, 1...6 VDC, 0...10 VDC, 0.1...10.1 VDC, 0.5...4.5 VDC ratiometric, Switching output: 1 or 2 PNP
  • Pressure connections: G1/4" m, 1/4"NPT m, 7/16"-20UNF SAE4 m
  • Ambient temperature: 40°C…+85°C
  • Suitable for thick and viscous media
  • Different materials for optimum media compatibility
  • EMC protection class is IEC 61000 (lightning, electrical discharge)
  • Range: 0...0,1 bar to 0...6 bar
  • Accuracy: +/- 0.3 %
  • Output: 4...20 mA
  • Ambient temperature: -25°C...+70 °C
  • Process temperature: -25°C...+70 °C
  • Supply: 9...32 VDC
  • Protection class: IP68
  • Material: Stainless steel (1.4404 (316L) / 1.4462 (318LN))
  • Sensor technology: Thick film on ceramic
  • Sensor material: Ceramics, Al2O3 96%
  • Cable insulation: PUR / Radox / PE
  • Industrial pressure transmitter’s measuring principle: Thin-film-on-steel
  • Applications: hydraulics, industrial applications, machine tools
  • 5-fold overpressure resistance
  • Measuring range: 0...2.5 / 0...700 bar // 0...30 / 0...10000 psi
  • Measuring accuracy at 25 °C typ.: ± 0.5 % FS typ. ± 0.3 % FS typ
  • Output signal: 4...20 mA, 0...5 VDC, 0.5...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
  • Ambient temperature: -40°C…+125°C
  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel, titanium
  • Certificates: ATEX, IECEx
  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.25 % FS
  • Output: 0...5 VDC / 0...10 VDC / 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel
  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel, titanium
  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel
  • Diameter: 19 mm
Loading...