  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel, titanium
  • Certificate: ATEX
  • Various level measurement ranges: 10...100 m H2O
  • Accuracy: ≤ ± 0.50 / 0.25
  • Output: 0...10 VDC / 4...20 mA
  • Process temperature: -5...50 °C
  • Operating temperature: -5...50 °C
  • Materials: stainless steel, titanium
  • Diameter: 10 mm
  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Recalibration with software possible
  • Output: 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel, titanium
  • Various level measurement ranges: 1...250 m H2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Output: 4...20 mA
  • Process temperature: -5...80 °C
  • Operating temperature: -5...80 °C
  • Materials: stainless steel, titanium
  • Certificate: ATEX
  • Long-lasting stainless steel screw electrodes
  • Measurement range: 7...20 % (-40...+125 °C)
  • Resolution: 0,1 %
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Electrode cable: FEP, -50...+200 °C, 5/10/15 m
  • Timber temperature compensation
  • Electrode length: 15 / 25 mm
  • Supply: 11...30 VDC
  • Protection class: IP68
  • 4 analog inputs (standard signals, RTD, thermocouple)
  • RS-485 Modbus output (Slave mode)
  • 2 alarm outputs
  • Galvanic isolation of inputs (2 from other 2)
  • Programmable individual characteristics, mathematical functions
  • Programmable time counters
  • Rail-mounted

DPC 8380 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.

DPS 8381 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.

  • Range: 0...2,5 iki 0...600 bar / 0...30 iki 0...7500 psi
  • Sensor type: Thick film on steel
  • Accuracy:  ±0,5 %
  • Output (chosen): 4...20 mA / 0...5 VDC / 0...10 VDC / 1...6 VDC
  • Switching outputs: 2 x PNP
  • Shown measuring units: bar, psi, MPa, kPa, m WC, mm WC
  • Ambient temperature: -25...+85 °C
  • Media temperature: -25...+85 °C
  • Protection class: IP65
  • Process connection: G1/4" m, R1/4" m, 1/4"NPT m, 1/2"NPT m
  • Data logger memory: 3518 points
  • Pressure range: from 0...2,5 to 0...700 bar
  • Process temperature: -40...+125 °C
  • Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
  • Protection class: IP65, IP67

The small sensor dimension combined with IO-Link, the pressure and temperature value of the media make the NAI 8273 the ideal choice in various applications.

  • Measuring range: -0.2...0.2 to 0...700 bar
  • Output signal: IO-Link 1.1, COM3, min. process cycle time 1 ms, Smart Sensor Profile ED2, 2 Switching outputs PNP / NPN
  • Accuracy at 25°C typically: ± 0.3 % FS typ., ± 0.5 % FS typ.
  • Measuring principle: Thin-film-on-steel
  • Media temperature –40... +125 °C
  • Ambient temperature: –40...+125 °C
  • Protection class: IP65, IP67
  • Applications: Hydraulics, Machine tools, Process technology
  • Pressure transmitter ATM (analog output)
  • Pressure measurement range: from 0 to 0,1...1000 bar
  • Accuracy: < ± 0,50 / 0,25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
  • Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M
  • Process temperature: -40...150 °C
  • Operating temperature: -25..85 °C
  • Materials: stainless steel, titanium
  • Pressure transmitter ATM.1ST/Ex (high precision, for explosive Ex environment)
  • Various pressure measurement ranges: 0,1...1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Output: 4...20 mA
  • Process temperature: -40...150 °C
  • Operating temperature: -40...125 °C
  • Materials: stainless steel, titanium
  • Certificates: ATEX, IECEx, EAC, GL/DNV, ABS, Lloyds
  • Pressure transmitter ATM/Ex (for explosive Ex environment)
  • Various pressure measurement ranges: 0,1...1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -40...150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Certificates: ATEX, IECEx, EAC
  • Pressure transmitter ATM/F (hygienic)
  • Various pressure measurement ranges: 0,1...25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
  • Process temperature: -25...100 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel
  • Pressure transmitter ATM/F/Ex (hygienic, for explosive Ex environment)
  • Various pressure measurement ranges: 0,1...25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
  • Process temperature: -25...150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel
  • Certificates: ATEX, EAC

Pressure transmitter CMP 8270 with CANopen output is designed for pressure measurement from 0...1 bar to 0...600 bar. Medium accuracy, small size, high temperature- and strong vibration-resistant.

  • Output: CANopen, protocol DS301 / DS404 
  • Range: from 0...1 bar to 0...600 bar 
  • Accuracy: ±0,2%
  • Process connection: G¼ 
  • Supply: 8...32 VDC
  • Temperature: -50...135ºC
  • Ambient temperature: -40...125ºC
  • Sensor material: stainless steel (1.4542)
  • Protection class: IP67
  • Pressure range: from 0...0,1 to 0...40 bar
  • Output signal: 4...20 mA / 0...5 VDC / 1...6 VDC / 0...10 VDC / 0,5...4,5 VDC
  • Process temperature: -25...+125 °C
  • Process connection: G1/4" f, G1/4" m, G1/2" m DIN3852-A, G1/2" m DIN3852-E, 1/4"NPT m ANSI B1.20.1, 1/8"NPT m ANSI B1.20.1, 7/16"-20UNF m SAE4, R1/4" m DIN3858, G3/4" frontal membrane
  • Applications: Machine tools, hydraulics, water treatment
  • Protection class: IP65, IP67, IP68
  • Pressure transmitter for shipbuilding, engine manufacturing
  • Measured pressure from 0...1 bar to 0...250 bar
  • Technology: thick film on ceramic
  • Output signal: 4...20 mA
  • Accuracy: 0,5 %
  • Operating temperature: -25...+125 °C
  • Ambient temperature: -25...+125 °C
  • Conformity: DNV, GL, KRS, RINA
  • Protection class: min. IP68

Pressure transmitter EPN/EPNCR 8298 is suited for ship industry (up to 2500 bar). Totally enclosed, stainless steel sensor system. Long-term reliability and stability, resistance to mechanical factors.

  • Range: nuo 0...2,5 iki 0...2500 bar
  • Accuracy: ± 0,3%
  • Output: 4...20mA / 0.5...4.5V DC
  • Process connection: G1/4“, R1/4“, G1/2“, M14x1.5, M18x1.5
  • Process temperature: -40°C...+125°C
  • Supply: 9...32 VDC / 5 VDC ±0.25 VDC
  • Protection class: IP67
  • Sensor material: nerūdijantis plienas 1.4548 (AISI630)     
  • Certification: GL, ABS, BV, DNV, RINA, LRS, KRS, NKK, RMRS
  • Certificates Ex ATEX and IECEx
    • Ex-zones 0, 1, 2 (gas), 20, 21, 22 (dust) and mining
  • High reliability and safety
  • Extraordinary long-term parameter stability
  • Range:
    • from 0...0.4 bar to 0...2000 bar
    • standard 0...0.4 bar to 0...250 bar
    • accuracy: ± 0.2% of range
  • Process connection: G1/4"
  • Output: 4...20 mA
  • Process temperature: -40°C...+120°C
  • Ambient temperature: -40°C...+120°C 
  • Supply: 10...30 VDC
  • Protection class: IP65
  • Casing material: stainless steel 1.4452 (AISI630)/ 1.4301 (AISI304)
  • Pressure transmitter is suited for ship industry, has extended temperature range and increased accuracy, M12 connection and IP67 protection class
  • Small size
  • Totally enclosed, stainless steel sensor system
  • Long-term reliability and stability, resistance to mechanical factors
  • Range: from 0...2,5 to 0...700 bar
  • Accuracy: ± 0,2%
  • Output: 4...20 mA
  • Process connection: G1/4" m; G1/4" m (Manometer EN 837); G1/8" a, DIN3852-E; 1/4"NPT m; M10x1 m
  • Process temperature: -25°C...+125°C
  • Ambient temperature: -40°C...+125°C
  • Supply: 9...32 VDC
  • Protection class: IP67
  • Sensor material: Stainless steel (1.4542)
  • Certification: ABS, BV, DNV, GL, KRS, LRS, RINA, for shipbuilding
  • Pressure range: from 0...6 to 0...600 bar
  • Output signal: 4...20 mA / 1 x PNP / 2 x PNP
  • Process temperature: -40...+125 °C
  • Accuracy: 0,3 %
  • Dielectric strength: 710 V
  • Measurement principle: thin film on steel
  • Protection class: IP65, IP67
  • Conformity: EN 50155, EN 45545-2, EN 61373, EN 50121-3-2
  • Parametrization by SMI programmer (not included) via Bluetooth connection from smartphone (Android)
  • Pressure transmitter for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measured pressure from 0...2,5 bar to 0...250 bar
  • Technology: thick film on steel
  • Output signal: 4...20 mA
  • Accuracy: 0,5 %, 0,3 %
  • Operating temperature: -40...+100 °C
  • Ambient temperature: -40...+100 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS
  • Increased vibration resistance
  • Totally enclosed, stainless steel sensor system
  • Long-term reliability and stability, resistance to mechanical factors
  • Measurement range: from 0…2 to 0…2.5 bar
  • Accuracy: 0,15...0,8 % (at 25 °C
  • Output: 4...20 mA, 0...5 V, 0...10 V
  • Process connection: G1/4 (optional G1/2 with additional adapter), 1/4” NPT
  • Process temperature: -40°C...+125 °C
  • Ambient temperature: -40°C...+125 °C
  • Supply: 9/15...32 VDC
  • Protection class: IP65 / IP67
  • Sensor material: stainless steel (1.4542)
  • Pressure transmitter PTM (programmable)
  • Various pressure measurement ranges: 0,1...1000 bar
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -40... 150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Various pressure measurement ranges: 0,1...1000 bar
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -40... 150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Certificates: ATEX, EAC
  • Various pressure measurement ranges: 0,1...1000 bar
  • Temperature measurement range: -25...85 °C
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Output: 2 x 4...20 mA
  • Digital output: RS-485
  • Process temperature: -40... 150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Various pressure measurement ranges: 0,1...1000 bar
  • Relay output: 2 units
  • Output: 0...20 mA / 4...20 mA
  • Process temperature: -40...150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Input: 4x RTD (Pt100, Pt1000, Ni100, Ni1000), resistive and potentiometer configurable input
  • Output: RS-485 Master/Slave and RS-232 (MODBUS RTU/ASCII protocol)
  • 2000 VAC galvanic isolation
  • High accuracy
  • EMC compliance - CE symbol
  • Mounting on DIN rail - EN-50022 complience
  • Supply voltage: 10...30 VDC
  • Ambient temperature: -10...+60°C
  • Ethernet 10/100 Base-T Modbus TCP interface (RJ-45 connector)
  • Configurable using webserver
  • RS-485 (Modbus RTU Master)
  • Distance up to 1200 m, up to 32 modules
  • LED indication
  • Galvanic isolation in all ways (1500 VAC)
  • EMC compliance
  • Mounting on DIN rail - EN-50022 compliance
  • Modbus Slave over RS-485
  • Modbus RTU / Modbus ASCII protocols
  • Communication parameters configurable by dip-switches
  • Watch-dog alarm
  • Remotely configurable
  • 3-way galvanic isolation (1500 VAC)
  • High accuracy
  • Mounting on DIN rail - EN-50022 compliance
  • Ethernet 10/100 Base-T interface
  • Modbus TCP server
  • Webserver for configuration of device and representation of actual input values
  • Galvanic isolation on all the ways (1500 VAC)
  • Remotely configured
  • LED indication
  • EMC compliance
  • DIN rail mounting
  • Measures air temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...+80 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...105 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • External sensor cable length: 1 / 2 / 4 m
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...125 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Operates as a temperature switch (thermostat), transducer, data logger
  • Accumulated temperature data is read using a mobile phone with NFC interface
  • Parametrization via NFC interface
  • Display and electrical connection are independently rotatable 335°/343°
  • Temperature measurement range: -50...+150 °C
  • Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
  • Switch output: 2 x PNP
  • Sensor: Pt1000 A
  • Data logger memory: 3518 measurement points
  • Measurement interval: 0,1...999,9 s
  • Operating temperature: -25...+85 °C
  • Supply: 15...30 VDC
  • Temperature transmitter 5331A with 4...20 mA output, designed for TC, RTD, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5333A with 4...20 mA output, designed for RTD signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5334A with 4...20 mA output, designed for TC, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5334B for explosive Ex atmosphere with 4...20 mA output, designed for TC, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5335A with 4...20 mA HART protocol output, designed for TC, RTD, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5350A with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
  • To be mounted into B-type electric head
  • Temperature transmitter 5350B for explosive Ex atmosphere with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
  • To be mounted into B-type electric head

Temperature transmitter DAT1010 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm) ir voltage (mV) signal conversion to analog (4...20 mA).

The transmitter is mounted into a B-type head. Programming can be done in our company.

Temperature transmitter DAT1015 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N)  and voltage (mV) signal conversion to analog (4...20 mA).

The transmitter is mounted into a B-type head. Programming can be done in our company.

Temperature transmitter DAT1066 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N)  and voltage (mV) signal conversion to analog (4...20 mA). With galvanic isoliation (1500 VAC).

The transmitter is mounted into a B-type head. Programming can be done in our company.

Temperature transmitter DAT1135 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (0...10 V). With galvanic isolation (1500 VAC).

The transmitter is mounted into a B-type head. Programming can be done in our company.

  • Input (configurable): TC, RTD, mV, resistance and potentiometer
  • Output: Modbus RTU / ASCII Slave device over RS-485
  • 1500 Vac 3-ways Galvanic Isolation
  • High accuracy
  • Remotely configurable over RS-485
  • EMC compliance (CE mark)
  • Mounting in B-type head
  • Easy implementation in existing PLCs and SCADA systems
  • Operating temperature: -40...+85°C
  • Supply voltage: 18...30 VDC
  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC