This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Search

Search Criteria

Products meeting the search criteria

Show:
Sort By:
  • P20G separator assures full galvanic isolation of the input, output and auxiliary supply and matching of analog signals in automation systems.
  • The device fulfills the requirements of III installation's category for the products designed to industrial application.
  • Fully configurable through the PD14 programmer and free delivered software LPConfig. By means of the programmer, one can change the

TSV202-60 ideal for monitoring battery banks, solar panels, industrial control circuits, and other high-voltage applications.

  • Dual channel input: 0…60 V
  • Communication interface: 1-Wire protocol
  • Accuracy: ±1%
  • Resolution: 0.001V
  • Galvanic isolation between the voltage circuit and 1-Wire bus
  • Operating environment: -20…+60 °C / 10…90 %RH
  • Warranty: 3 years
  • Dual channel input: 0…24 mA or 0…10 V
  • Communication interface: 1-Wire protocol
  • Accuracy: ±1 %
  • Resolution: 0.001mA / 0.001 V
  • Galvanic isolation between the current circuit and 1-Wire bus
  • Detection of special states such as sensor errors or calibration values
  • Operating environment: -20…+60 °C / 10…90 %RH
  • Warranty: 3 years
  • 1-Wire protocol current transmitter
  • Current measurement range: 0,3...15 A (AC / DC, set by jumper)
  • Resolution: 10 bits
  • Galvanic isolation between the current circuit and 1-Wire bus
  • Excellent long-term stability
  • Warranty: 3 years
  • Connection: RJ-11
  • Input: Pt100 (2-, 3-, 4-wire)
  • Measurement range: -200...+850 °C
  • Resolution: 24 bits
  • Very low current consumption
  • No external power supply needed
  • Warranty: 3 years
  • Connection: RJ-11
  • Input: 2x thermocouples - J, K, T, N, E, B, R, and S
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…30 Vdc
  • Warranty: 3 years
  • Input voltage range: 0…264 Vac or 0…370 Vdc
  • Input frequency: 0…60 Hz
  • Input resistance: >2.4 MOhm
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • True RMS measurement
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…28 Vdc
  • Warranty: 3 years
  • Temperature measurement range: -30...+80 °C
  • Humidity measurement range: 0...100 %
  • Output: RS-485 Modbus RTU
  • Calculates absolute humidity and dew-point temperature
  • Cable length: 2 m / 2 m with M8 connector / 5 m / 10 m
  • Operating temperature: -20...+60 °C
  • Supply: 9...28 VAC/VDC
  • Ambient temperature and humidity transducer with 4...20 mA output
  • Integrated sensors
  • Calibration certificate is included
  • Economical
  • Ambient temperature and humidity transducer with 4...20 mA output
  • Stem length 700 mm
  • Calculated values: dew point temperature, absolute humidity, specific humidity, mixing ration, specific enthalpy
  • Display with two periodically changed shown values (can be switched off)
  • Integrated sensors
  • Calibration certificate is included
  • Programmable output
  • Low temperature inertia
  • For use in non-aggressive environment
  • 3 year warranty
  • Carbon dioxide (CO2) range: 0… 2000 ppm or 0…4000 ppm (selectable)
  • Stable long-life optical NDIR sensor
  • Response time: < 2 min
  • Output: 0...10 V arba 4...20 mA
  • Ambient temperature: 0...+ 50 ºC
  • Supply: 24 VAC/ VDC
  • Protection class: IP 30
  • Dimensions: 98 x 98 x 33 mm
  • Application: offices, hotels, convention centers, apartments, shops, etc.

Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.

  • Carbon dioxide (CO2) range: 400...2000 ppm
  • Humidity range: 0...100 % 
  • Temperature range: 0...50 °C
  • CO2 concentration measurement range: 0...10 000 ppm
  • Output: 4...20 mA
  • Programmable
  • External probe cable length: 1 / 2 / 4 m
  • LCD display
  • Calibration certificate included
  • Ambient temperature: -30...+80 °C
  • Supply: 9...30 VDC
  • Protection class: IP65
  • Warranty: 3 years

Temperature transducers P4141, P4121, P4151, P4131, P4161, P4171, P4191 with 4...20 mA output and Pt1000 input.

P4121 – P4171 class transducers are designed to convert RTD Pt1000 (3850ppm/°C) signal to current. These transducers have 4...20 mA output. RTD sensor Pt1000 is not included.

  • Current (AC / DC) transducer T23CT with 4...20 mA output
  • AC/DC current input (single option): up to 50 / 100 / 150 / 200 / 300 A
  • Optional mounting on DIN rail
  • Galvanic isolation
  • Supply: 24 VDC
  • Ambient temperature: -25...+55 °C
  • Protection class: IP65, IP40 for terminals
  • Pressure range: from 0...1 to 0...16 bar
  • Output signal: 4 ... 20 mA (P1–P2)
  • Process temperature: -25...+125 °C
  • Process connection: G1/4" f
  • Protection class: min. IP65

Duct temperature transducer with 4...20 mA output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Calibration certificate is included.

Duct temperature transducer with 0...10 V output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Output temperature range is user adjustable. Calibration certificate is included.

  • Temperature measurement range: -35…+80 ºC
  • Humidity measurement range: 0…100 % RH
  • Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
  • Output: Modbus RTU
  • Allowed overpressure/ bellow: ± 50 kPa
  • Operating temperature: 24 VAC / 15…35 VDC
  • Protection class: IP 65
  • Hydrogen pressure transmitter’s measuring principle: Thin-film-on-steel
  • EC79 and ECER-134 certification pending (see product website for current situation)
  • Applications: Fuel cells, fueling stations, hydrogen compressors, hydrogen tanks, vehicles with H drive
  • Measuring range: 0…1050 bar / 0…15000 psi *(see product datasheet)
  • Measuring accuracy at 25 °C typ.: ± 0.3 / 0.5 % FS typ.
  • Output signal: 4...20 mA, 0.5...4.5 VDC, 0...5 VDC, 1...5 VDC, 1...6 VDC, 0...10 VDC, 0.1...10.1 VDC, 0.5...4.5 VDC ratiometric, Switching output: 1 or 2 PNP
  • Pressure connections: G1/4" m, 1/4"NPT m, 7/16"-20UNF SAE4 m
  • Ambient temperature: 40°C…+85°C
  • Suitable for thick and viscous media
  • Different materials for optimum media compatibility
  • EMC protection class is IEC 61000 (lightning, electrical discharge)
  • Range: 0...0,1 bar to 0...6 bar
  • Accuracy: +/- 0.3 %
  • Output: 4...20 mA
  • Ambient temperature: -25°C...+70 °C
  • Process temperature: -25°C...+70 °C
  • Supply: 9...32 VDC
  • Protection class: IP68
  • Material: Stainless steel (1.4404 (316L) / 1.4462 (318LN))
  • Sensor technology: Thick film on ceramic
  • Sensor material: Ceramics, Al2O3 96%
  • Cable insulation: PUR / Radox / PE
  • Industrial pressure transmitter’s measuring principle: Thin-film-on-steel
  • Applications: hydraulics, industrial applications, machine tools
  • 5-fold overpressure resistance
  • Measuring range: 0...2.5 / 0...700 bar // 0...30 / 0...10000 psi
  • Measuring accuracy at 25 °C typ.: ± 0.5 % FS typ. ± 0.3 % FS typ
  • Output signal: 4...20 mA, 0...5 VDC, 0.5...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
  • Ambient temperature: -40°C…+125°C
  • Incremental encoder output: A, B   /   A, B, Z   /   A, /A, B, /B   /   A, B, Z, /A, /B, /Z
  • Resolution: 5 / 10 / 25 / 50 μm
  • Magnetic measurement (contactless, non-friction system)
  • Vibration-resistant
  • Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
  • Supply: 10...30 VDC / 5 VDC
  • Operating temperature: -25...+85 °C
  • Protection class: IP67
  • Incremental encoder output: A, B   /   A, B, Z   /   A, /A, B, /B   /   A, B, Z, /A, /B, /Z
  • Resolution: 5 / 10 / 25 / 50 μm
  • Portable reference point
  • Stroke values up to 2000 mm
  • Vibration-resistant
  • Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
  • Supply: 10...30 VDC / 5 VDC
  • Operating temperature: -25...+85 °C
  • Protection class: IP65

Linear encoder MLS110. With cable connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS110. With spiral connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS120.

Technical specifications

  • Casing integrated into slider
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS130. Very small size.

 

Technical specifications

  • Very small measuring head (in metal enclosure)
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS210. With spiral connection and slider joints.

 

Technical specifications

  • Protection class IP67
  • Twin sliders
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS210. With spiral connection.

 

Technical specifications

  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC
  • 4 analog inputs (standard signals, RTD, thermocouple)
  • RS-485 Modbus output (Slave mode)
  • 2 alarm outputs
  • Galvanic isolation of inputs (2 from other 2)
  • Programmable individual characteristics, mathematical functions
  • Programmable time counters
  • Rail-mounted

LTC potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

The main difference from LTM transducers is that LTC has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines

LTM potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

Movement of up to 1000 mm. High resolution (0,01 mm). No additional parts such as gears are needed, because transducer construction enables the direct connection into mechanical system.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines

LTP potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

The main difference from LTM transducers is that LTP has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines

Power network transducer P41 is designed to convert 1-phase power network parameters into analog or digital signal. Measured parameters: voltage (U), current (I), frequency (f), active power (P), reactive power (Q), apparent power (S), power factor (PF), reactive power coefficient (tgφ), phase angle difference (φ), active energy (Ep), reactive energy (Eq).

  • universal inputs (1 A or 5 A, 100 V or 400 V)
  • programmable analog output ( -20 mA...+20 mA)
  • parameter transfer via RS-485 interface (Modbus RTU protocol)
  • chosen values memory (9000 records)
  • programmable current and voltage transformer coefficients
  • transducer settings are changed via „LPConfig“ software (USB)

Power network transducer P43 is designed to measure 3-phase (three or four-wire systems) power network parameters. Two parameter values are converted into analog output signal -20...+20 mA. Other parameter values are sent over RS-485 or USB ports. All parameter min and max values are measured. Data refresh interval is less than 1 s. Output signals are isolated from input and supply. Two programmable alarm outputs. Pulse (passive) output OC can be used for energy accounting. Mounted on 35 mm rail.

  • Measuring ranges:
    • current 1/5 A L1...L3: 0,02...6 A
    • voltage L-N/L-L: 2,9...276/ 10...480 V
    • frequency: 45,00...66 Hz
    • active power: -1,65 kW...1,4 W...1,65 kW
    • reactive power: -1,65 kvar...1,4 var...1,65 kvar
    • apparent power: 1,4 VA...1,65 kVA
    • power factor: -1...0...1
    • active energy: 0...99 999 999,9 kWh
    • sum energy: 0...99 999 999,9 kvarh
  • Consumed power: ≤ 6 VA
  • Transformation coefficients: Ku = 1...4000, Ki = 1...10000
  • Supply: 85...253 VDC or AC 40...400 Hz
  • Ambient temperature: -10...23...+55 °C
  • Measuring range: -1…100 bar (see datasheet)
  • Basic accuracy 0,5% of range
  • Output: 4…20 mA
  • Process connection: G 1/2“, G 1/2“, G 1/2“ Flush membrane, G 1/4“, G 1/4“, 1/2“ NPT, 1/4“ NPT, Tri-Clamp (Ø 50,5) Flush membrane
  • Operating temperature: -20…+85 / 200 °C (see datasheet)
  • Stainless steel housing and diaphragm material
  • Protection class: IP67 / IP68

DPC 8380 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.

DPS 8381 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.

  • Range: 0...2,5 iki 0...600 bar / 0...30 iki 0...7500 psi
  • Sensor type: Thick film on steel
  • Accuracy:  ±0,5 %
  • Output (chosen): 4...20 mA / 0...5 VDC / 0...10 VDC / 1...6 VDC
  • Switching outputs: 2 x PNP
  • Shown measuring units: bar, psi, MPa, kPa, m WC, mm WC
  • Ambient temperature: -25...+85 °C
  • Media temperature: -25...+85 °C
  • Protection class: IP65
  • Process connection: G1/4" m, R1/4" m, 1/4"NPT m, 1/2"NPT m
  • Data logger memory: 3518 points
  • Pressure range: from 0...0,1 to 0...40 bar
  • Output signal: 4...20 mA / 0...5 VDC / 1...6 VDC / 0...10 VDC / 0,5...4,5 VDC
  • Process temperature: -25...+125 °C
  • Process connection: G1/4" f, G1/4" m, G1/2" m DIN3852-A, G1/2" m DIN3852-E, 1/4"NPT m ANSI B1.20.1, 1/8"NPT m ANSI B1.20.1, 7/16"-20UNF m SAE4, R1/4" m DIN3858, G3/4" frontal membrane
  • Applications: Machine tools, hydraulics, water treatment
  • Protection class: IP65, IP67, IP68
  • Pressure transmitter for shipbuilding, engine manufacturing
  • Measured pressure from 0...1 bar to 0...250 bar
  • Technology: thick film on ceramic
  • Output signal: 4...20 mA
  • Accuracy: 0,5 %
  • Operating temperature: -25...+125 °C
  • Ambient temperature: -25...+125 °C
  • Conformity: DNV, GL, KRS, RINA
  • Protection class: min. IP68
  • Pressure range: from 0...6 to 0...600 bar
  • Output signal: 4...20 mA / 1 x PNP / 2 x PNP
  • Process temperature: -40...+125 °C
  • Accuracy: 0,3 %
  • Dielectric strength: 710 V
  • Measurement principle: thin film on steel
  • Protection class: IP65, IP67
  • Conformity: EN 50155, EN 45545-2, EN 61373, EN 50121-3-2
  • Parametrization by SMI programmer (not included) via Bluetooth connection from smartphone (Android)
  • Pressure transmitter for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measured pressure from 0...2,5 bar to 0...250 bar
  • Technology: thick film on steel
  • Output signal: 4...20 mA
  • Accuracy: 0,5 %, 0,3 %
  • Operating temperature: -40...+100 °C
  • Ambient temperature: -40...+100 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS
  • Measuring function: differential pressure, volume flow
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: switchable 0-10 V/ 4 ... 20 mA (via DIP switches)
  • Allowed overpressure: 50 kPA
  • Supply: 24 VAC
  • Medium: clear air, non-aggressive, non-combustible gases
  • Protection class: IP 54

Relative humidity and temperature transducer P18D with display and RS-485 output, designed for temperature and humidity measurement.

  • Signal splitter DAT5022
  • Configurable with switches on body
  • 3-way galvanic isolation (2000 VAC)
  • Input: 4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V
  • Output: 2 X (4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V)
  • Power Supply: 18...32 VDC. Reverse polarity protection 60 VDC
  • Current Consumption: Current output 35 mA max. Voltage output 25 mA max.
  • Environment: -20...+70 °C / (non-condensing) 0-90%
  • Housing: Self-extinguishing material
  • EMC
    • Immunity: EN 61000-6-2
    • Emission: EN 61000-6-4

Temperature and air humidity transducer P19 with RS-485 output, designed for room humidity ant temperature contro. Can be used in various control and monitoring systems. Output signal is digital (RS-485, MODBUS). Transducer parameters are programmed via PC. Wall-mounted. Can work in condensation-free environment.

 

  • Integrated temperature and humidity sensor
  • Calculated values – dew point temperature, absolute humidity
  • Minimal and maximal value memory
  • Isolated RS-485 port
  • Measures air temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...+80 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...105 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • External sensor cable length: 1 / 2 / 4 m
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
Loading...