Your shopping cart is empty!
- Measures air temperature, humidity in ducts
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...125 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
Temperature and standard signal transducer P30U.
- Programmable input
- Mathematical functions
- Individual channel characteristic
- 1 or 2 outputs
- Variant with internal transducer 24 VDC power supply
- RS-485 interface
- Adjustable dimension
- Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
- Transducer programming with buttons or via PC (“LPConfig” software)
- Patented quality product (immersion sensor patent)
- Measuring ranges: multi-range switching with 8 switchable measuring ranges
- Output: 0 – 10 V or 4...20 mA
- Sleeve length: 50, 100, 150, 200, 250, 300, 400 mm
- Supply 24 VAC/ VDC – U var. or 15...36 VDC I var.
- Medium: in liquid or gaseous media
- For aggressive media, stainless steel immersion sleeves must be used
- Ambient temperature: -30…+70 ºC
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitters with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…80 °C
- Operating temperature: -40…80 °C
- The sensor can be distanced, meaning the TJ-O can be equipped with the following external temperature sensors: TJ-1, TJ-2, TJ-4, TJ-S
- Sensor tube:
- Material: Stainless steel AISI304 (1.4301)
- Diameter: Ø6 mm
- Length: 25 mm
- Mounting box:
- Material: Polystyrene
- Dimentions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-1 is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-4 is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-S is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Operates as a temperature switch (thermostat), transducer, data logger
- Accumulated temperature data is read using a mobile phone with NFC interface
- Parametrization via NFC interface
- Display and electrical connection are independently rotatable 335°/343°
- Temperature measurement range: -50...+150 °C
- Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
- Switch output: 2 x PNP
- Sensor: Pt1000 A
- Data logger memory: 3518 measurement points
- Measurement interval: 0,1...999,9 s
- Operating temperature: -25...+85 °C
- Supply: 15...30 VDC
- Temperature transducer TJ-DIN AV, designed to convert temperature measurement signal into 4...20 mA, 0...10 V
- Mounted on 35 mm DIN rail
- Input: RTD: Pt100 (3-wire), TC: J, K N
- Output: IO-Link
- Configuration: via IO-Link
- Operating temperature: -20...+80 °C
- Supply 24 VDC
Temperature transducer with 0...10 V output is built in a durable watertight case. Built-in precise temperature sensor. Output temperature range is user adjustable. Calibration certificate is included.
Temperature transducer with 0...10 V output is built in a durable watertight case. To be used with an external Pt1000 temperature probe. Output temperature range is user adjustable. Calibration certificate is included.
- Input: RTD: Pt100 (3-wire), TC: J, K N
- Output: IO-Link
- Configuration: via IO-Link
- Operating temperature: -20...+80 °C
- Supply 24 VDC
Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.
- Transducer for AC current and voltage into DC signal (1 output)
- Input, output and supply of the transducer are galvanic insolated
- The construction of the transducer ensures accurate and fast signal transformation
- Fast and easy installation on rail, or onto a wall or in panel using holder
- Transducer for DC current and voltage into other DC signal (1 output)
- Input, output and supply of the transducer are galvanic insolated
- Solves grounding problem in meshed signal networks
- User selectable type and range of input
- Transducer for DC current and voltage into other DC signal (2 outputs)
- Input, output and supply of the transducer are galvanic insolated
- The construction of the transducer ensures accurate and fast signal transformation
- Fast and easy installation on rail, or onto a wall or in panel using holder
- Signal transducer P20Z is designed to convert AC current and voltage (without direct component) into DC voltage or current signal
- Input is isolated from input and supply
- Has fixed inputs and outputs – non-programmable
- Up to 10 / 15 m level measurement with automatic temperature compensation
- Calculation of filling in the tank or flow in open channels
- Galvanically isolated 0/4...20 mA analog output
- Digital RS-485 Modbus RTU interface
- 2 alarm outputs
- Internal data and setup memory
- Two 32-points individual characteristics (for recalculation)
- LCD screen
- Housing protection grade: IP66
- Sensor protection grade: IP66 / IP 68
- Supply: 12...25...40 VDC
- Operating temperature: -20...23...55 °C
- Up to 10 / 15 m level measurement
- Analog output: 4…20 mA
- Digital output: RS-485 Modbus RTU
- Resolution: 3 mm
- Supply: 24 VDC / 300 mA
- Operating temperature: -20...60 °C
- Cable length: 1 m