This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Search

Search Criteria

Products meeting the search criteria

Show:
Sort By:
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...125 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included

Temperature and standard signal transducer P30U.

 

  • Programmable input
  • Mathematical functions
  • Individual channel characteristic
  • 1 or 2 outputs
  • Variant with internal transducer 24 VDC power supply
  • RS-485 interface
  • Adjustable dimension
  • Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
  • Transducer programming with buttons or via PC (“LPConfig” software)
  • Patented quality product (immersion sensor patent)
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: 0 – 10 V or 4...20 mA
  • Sleeve length: 50, 100, 150, 200, 250, 300, 400 mm
  • Supply 24 VAC/ VDC – U var. or 15...36 VDC I var.
  • Medium: in liquid or gaseous media
  • For aggressive media, stainless steel immersion sleeves must be used
  • Ambient temperature: -30…+70 ºC
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitters with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…80 °C
  • Operating temperature: -40…80 °C
  • The sensor can be distanced, meaning the TJ-O can be equipped with the following external temperature sensors: TJ-1, TJ-2, TJ-4, TJ-S
  • Sensor tube:
    • Material: Stainless steel AISI304 (1.4301)
    • Diameter: Ø6 mm
    • Length: 25 mm
  • Mounting box:
    • Material: Polystyrene
    • Dimentions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…180 °C (depends on probe)
  • Operating temperature (case with transmitter): -40…80 °C
  • The sensor TJ-1 is selected according to the individual order
  • Mounting box:
    • Material: Polystyrene
    • Dimensions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…180 °C (depends on probe)
  • Operating temperature (case with transmitter): -40…80 °C
  • The sensor TJ-4 is selected according to the individual order
  • Mounting box:
    • Material: Polystyrene
    • Dimensions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…180 °C (depends on probe)
  • Operating temperature (case with transmitter): -40…80 °C
  • The sensor TJ-S is selected according to the individual order
  • Mounting box:
    • Material: Polystyrene
    • Dimensions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Operates as a temperature switch (thermostat), transducer, data logger
  • Accumulated temperature data is read using a mobile phone with NFC interface
  • Parametrization via NFC interface
  • Display and electrical connection are independently rotatable 335°/343°
  • Temperature measurement range: -50...+150 °C
  • Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
  • Switch output: 2 x PNP
  • Sensor: Pt1000 A
  • Data logger memory: 3518 measurement points
  • Measurement interval: 0,1...999,9 s
  • Operating temperature: -25...+85 °C
  • Supply: 15...30 VDC
  • Temperature transducer TJ-DIN AV, designed to convert temperature measurement signal into 4...20 mA, 0...10 V
  • Mounted on 35 mm DIN rail
  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC

Temperature transducer with 0...10 V output is built in a durable watertight case. Built-in precise temperature sensor. Output temperature range is user adjustable. Calibration certificate is included.

Temperature transducer with 0...10 V output is built in a durable watertight case. To be used with an external Pt1000 temperature probe. Output temperature range is user adjustable. Calibration certificate is included.

  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC

Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.

  • Transducer for AC current and voltage into DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • Transducer for DC current and voltage into other DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • Solves grounding problem in meshed signal networks
  • User selectable type and range of input
  • Transducer for DC current and voltage into other DC signal (2 outputs)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • Signal transducer P20Z is designed to convert AC current and voltage (without direct component) into DC voltage or current signal
  • Input is isolated from input and supply
  • Has fixed inputs and outputs – non-programmable
  • Up to 10 / 15 m level measurement with automatic temperature compensation
  • Calculation of filling in the tank or flow in open channels
  • Galvanically isolated 0/4...20 mA analog output
  • Digital RS-485 Modbus RTU interface
  • 2 alarm outputs
  • Internal data and setup memory
  • Two 32-points individual characteristics (for recalculation)
  • LCD screen
  • Housing protection grade: IP66
  • Sensor protection grade: IP66 / IP 68
  • Supply: 12...25...40 VDC
  • Operating temperature: -20...23...55 °C
  • Up to 10 / 15 m level measurement
  • Analog output: 4…20 mA
  • Digital output: RS-485 Modbus RTU
  • Resolution: 3 mm
  • Supply: 24 VDC / 300 mA
  • Operating temperature: -20...60 °C
  • Cable length: 1 m
Loading...