  • The temperature sensor TJ-PL12 is designed for measuring temperature ranging from -50°C to 400°C
  • The design could be changed according the requirements and drawings of the customer
  • Measuring range: -50°C ... 400°C
  • Temperature sensor TJ-S (with cable, angled), designed for temperature measurement from -25 to +180 °C
  • Various versions are available we also produce sensors according to client’s requests
  • Sensor type:  Pt100, Pt1000, K, J, PTC, NTC
  • Temperature sensor TJ-S is inextricably connected to the cable, it is designed for temperature measurement from -50°C to 400°C
  • Various sizes are available depending on customer requirements and drawings
  • Sensor type: PT100, PT1000, K, J

The TJ-S temperature sensor is permanently connected to a cable and designed for measuring temperatures from -50°C to 400°C.

Various cable lengths are available.

  • Sensor type: PT100, PT1000, NTC, Thermocouples K, J
  • Measuring range: -50…+400 °C
  • Operating temperature:
    • -30...+70 °C (PVC isolation)
    • -50...+180 °C (Silicone isolation)
    • -50...+400 °C, kabelio -50...+250 °C (Teflon isolation)
    • -50...+400 °C, kabelio -50...+400 °C (Fiberglass isolation)
  • Cable and connection: 2, 3, 4 wire
  • Sensor tube:
    • Material: Stainless steel 316 (1.4401)
    • Diameter: Ø4 mm
    • Length: 120 mm
  • The temperature sensor TJ1-TTP is inextricably connected to the cable, it is designed for measuring the temperature ranging from -30 °C to 400 °C
  • Various sizes are available depending on customer requirements and drawings
  • Sensor type: termocouple K, J
  • Temperature sensor TJ1TE – NTC10k3B HVAC developed for air conditioning devices and heating, ventilation, (HVAC) systems
  • Measurement range: -30…+105 °C
  • Sensor: NTC; Rnom = 10 kΩ at +25 °C; steepness β = 3977 (+25...+85 °C)
  • Accuracy: enhanced accuracy ± 0.2 % in range 0...+75 °C, in the rest ± 1 %
  • Measuring part housing: PVC; dimensions 4,5 x 90 mm
  • Cable of two wire with PVC insulation: standard lengths - 0,1 m; 1,5 m; 3 m; 6 m
  • Protection class: IP54
  • Fastening with rubber sleeve and / or flange holder according to the drawing (see drawing above)

RTD sensors with TOPGDM, TOPGDS connectors. With threaded process connector, designed to measure temperature in pipes, tanks and canals. Measuring range is -50...+400 ºC. Can be fit with a LED display.

  • Temperature range: from +20...+110 °C iki +40...+300 °C
  • Output signal: 1 floating change-over contact
  • Process temperature: +20...+300 °C
  • Approval: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, RMRS, EN60730-1/ EN60730-2-9: Typ 2.B.H
  • Protection class: IP65
  • Input: RTD: Pt100 (2-wire) / TC: K
  • Output: relay (NC/NO)
  • Configuration: via HART (switching point, hysteresis, switching delay, damping), with magnet (switching point)
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC
  • Operates as a temperature switch (thermostat), transducer, data logger
  • Accumulated temperature data is read using a mobile phone with NFC interface
  • Parametrization via NFC interface
  • Display and electrical connection are independently rotatable 335°/343°
  • Temperature measurement range: -50...+150 °C
  • Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
  • Switch output: 2 x PNP
  • Sensor: Pt1000 A
  • Data logger memory: 3518 measurement points
  • Measurement interval: 0,1...999,9 s
  • Operating temperature: -25...+85 °C
  • Supply: 15...30 VDC
  • Temperature transducer TJ-DIN AV, designed to convert temperature measurement signal into 4...20 mA, 0...10 V
  • Mounted on 35 mm DIN rail
  • Temperature transmitter 5331A with 4...20 mA output, designed for TC, RTD, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5333A with 4...20 mA output, designed for RTD signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5334A with 4...20 mA output, designed for TC, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5334B for explosive Ex atmosphere with 4...20 mA output, designed for TC, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5335A with 4...20 mA HART protocol output, designed for TC, RTD, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5350A with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
  • To be mounted into B-type electric head
  • Temperature transmitter 5350B for explosive Ex atmosphere with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
  • To be mounted into B-type electric head

Temperature transmitter DAT1010 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm) ir voltage (mV) signal conversion to analog (4...20 mA).

The transmitter is mounted into a B-type head. Programming can be done in our company.

Temperature transmitter DAT1015 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N)  and voltage (mV) signal conversion to analog (4...20 mA).

The transmitter is mounted into a B-type head. Programming can be done in our company.

Temperature transmitter DAT1066 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N)  and voltage (mV) signal conversion to analog (4...20 mA). With galvanic isoliation (1500 VAC).

The transmitter is mounted into a B-type head. Programming can be done in our company.

Temperature transmitter DAT1135 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (0...10 V). With galvanic isolation (1500 VAC).

The transmitter is mounted into a B-type head. Programming can be done in our company.

  • Input (configurable): TC, RTD, mV, resistance and potentiometer
  • Output: Modbus RTU / ASCII Slave device over RS-485
  • 1500 Vac 3-ways Galvanic Isolation
  • High accuracy
  • Remotely configurable over RS-485
  • EMC compliance (CE mark)
  • Mounting in B-type head
  • Easy implementation in existing PLCs and SCADA systems
  • Operating temperature: -40...+85°C
  • Supply voltage: 18...30 VDC
  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC

Temperature transducer with 0...10 V output is built in a durable watertight case. Built-in precise temperature sensor. Output temperature range is user adjustable. Calibration certificate is included.

Temperature transducer with 0...10 V output is built in a durable watertight case. To be used with an external Pt1000 temperature probe. Output temperature range is user adjustable. Calibration certificate is included.

  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC
  • Temperature measurement range: -20...+60 °C
  • Humidity measurement range: 0...100 %RH
  • CO2 concentration measurement range: 0...5000 ppm
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Internal sensors
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+60 °C
  • Supply: 5200 mAh LiIon battery
  • Protection class: IP20
  • Warranty: 3 years
  • Measures ambient temperature, humidity, pressure
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measuring ranges: -30...+80 °C, 0...100 %RH, 600...1100 hPa
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Protection class: IP30
  • Temperature measurement range: -20...+60 °C
  • Humidity measurement range: 0...100 %RH
  • Pressure measurement range: 600...1100 hPa
  • CO2 concentration measurement range: 0...5000 ppm
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Internal sensors
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+60 °C
  • Supply: 5200 mAh LiIon battery
  • Protection class: IP20
  • Warranty: 3 years

Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.

Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.

  • Flow and temperature sensor for liquids in pipes
  • Output: 1 x 4...20 mA, 1 x PNP / 2 x PNP
  • Flow measurement range: 1...150 cm/s (water)
  • Temperature measurement switching points: 15, 30, 45, 60, 75 °C
  • Flow rate measurement is shown in a bar graph by five green LEDs
  • Settings provided by magnetic pen
  • Stainless steel case
  • Supply: 12...34 VDC
  • Ambient temperature: -20...+80 °C
  • Protection class: IP67 / IP68
  • Wide temperature range: -10...+1200 °C
  • 320 x 240 and 640 x 480 infrared resolution
  • 9 or 60 Hz models available
  • Sighting: IR-Fusion technology (thermal and visible sighting) for easy alignment and added detail on blended images
  • Remote motorized focus
  • Multiple field interchangeable lens options available
  • GigE Vision interface
  • LAN/Ethernet with PoE for communication with the thermal imager provides access to Ethernet, Web server and ThermoView Software
  • I/O alarming capabilities
  • ThermoView software for industrial automation applications
  • Ambient temperatures to 200 °C with high temperature enclosure
  • Air purge and accessories available
  • Rugged housing, IP67 rated
  • Air velocity, airflow and temperature measurement
  • Air flow measurement with a cone
  • Automatic average
  • Display of minimum and maximum values, hold function
  • Adjustable auto shut-off
  • Detection of flow direction
  • Selection of units
  • Supplied with calibration certificate
  • Display of minimum and maximum values, hold function
  • Adjustable auto shut-off
  • Automatic average
  • Selection of units
  • Detection of flow direction (LV 110/LV 117)
  • Supplied with calibration certificate
  • Air flow measurement with a cone (LV 110/LV 117)
  • Thermocouple commutatotr TK with cold junction compensation for thermocouple measurement output (in turns) to one output
  • Connecting that output to measuring device or indicator enables the monitoring of thermocouples in turns
Thermocouple sensors TTE with cable. Technical specifications Example Model Range Protective tube Cable insulation TTE310 -40 .. +400°C Ø5, Ø6, Ø8 mm PVC, silicone, teflon, glass fiber TTE311 TTE312 TTE409 -40 .. +400°C Ø5, Ø6, Ø8 mm TTE410 TTE411 -4..
Thermocouple sensors TT with connection head. Technical specifications Example Model Range Accuracy Tube* diameter TT_G -40…+800°C 1 class (standard) or 2 according to EN 60584 Various variants available TT_GB -40…+150°C TT_GN -40…+800°C TT_P -40…+800°C ..
Thermocouple sensors TTP with mineral insulation. Technical specifications Example Model Range Diameter TTP-NA -40 .. +1250°C Ø1.0 .. Ø8.0 TTP-BTW -40 .. +1250°C Ø0.25 .. Ø3.0 TTP-WL -40 .. +1250°C Ø1.0 .. Ø6.0  TTP-TKbW -40 .. +1250°C Ø0.25 .. Ø8.0 ..
  • Measurement range: -40…+180 °C
  • Type: J / K / N / T / E
  • Self-adhesive tape
  • Thermocouple tolerance (accuracy), cable length and insulation can be chosen by demand (see datasheet)
  • Optional: temperature transducer (4...20 mA / 0...10 V / HART / Profibus PA / Fieldbus)
  • Optional: connector
  • Thermocouple with small measurement tip AUREGIS TJ-K for temperature measurements from -75 °C to +250 °C, fast measurement
  • Sensor type: thermocouple K (NiCr-NiAl), class 2
  • Measurement range: -75 °C to +250 °C
  • Connection: mini connector

Capillary thermometer TXC is designed for temperature measurement from -200 to +800 °C. Capillary parameters, diameter and length of measuring element, measurement dial range, process connection, contact type and other parameters must be chosen from the catalogue. 

Stainless steel thermometer TXR is designed for temperature measurement from -200 to +800 °C. Diameter and length of measuring element, measurement dial range, process connection, contact type and other parameters must be chosen from the catalogue. 

Temperature relay, mechanical thermostat A/AS/ASE 645/650 for temperature control. Technical specifications Range -45...+15 °C iki 0...60 °C Accuracy  ±2 % Output Switch Switching voltage, current 5...500 VAC, 0,01...20 AAC5...250 VDC, 0,01...20 ADC Ambient temperature -30...50 °C Protection class IP54 Certification EN60730..

Temperature relay, mechanical thermostat ATR83 with pipe-mounting for temperature control.

Temperature relay, mechanical thermostat EXAS 409/419 with internal temperature control. Technical specifications Range -30...+60 °C Accuracy  ±2 % Output Switch Switching voltage, current 30 VDC, 5 (5) A 250 VAC, 5 (3) A 250 VDC, 0,25 (0,03) A Protection class IP65 Sensor material Nickel-coated brass Certified for explosive Ex atmosphe..
Temperature relay, mechanical thermostat IA/IAS 409/419 with external temperature setting for temperature control. Technical specifications Range IA33: -30...+30 °CIA35: +5...+35 °CIA60: 0...+60 °C Accuracy  ±2 % Output Switch Switching voltage, current 500 VAC 10 (0,75) A30 VDC 6 (1,5) A250 VDC 0,25 (0,03) A Ambient temperature -30...50 °C Protection ..

Temperature relay, mechanical thermostat JTF-1 for frost protection.

Temperature relay, mechanical thermostat M/MS 624/634 with external temperature setting for temperature control. Technical specifications Range -30...+350 °C Accuracy  ±2 % Capillary tube length 2 m Output Switch Setting External Cable Ø 4...9 mm Switching voltage, current 500 VAC 10 (0,75) A30 VDC 6 (1,5) A250 VDC 0..
Loading...