Portable temperature calibrator for dry air Pyros 650. These innovative calibrators have been designed for on-site applications and for the severe conditions of the naval and marine sectors. Their ease of use, compact and practical design make them unbeatable in industrial processes where the verification of the temperature measurement systems is a key issue for the control of the process and the quality of the final product. Special attention was paid to reduce the weight, to the small size and sound design obtained by using an aluminum body and aluminum and stainless steel for m..
  • Modern, simple and user-friendly service
  • Communication interfaces: RS-485 Modbus Slave, Modbus TCP Slave and optionally Ethernet
  • FTP server (available in controller versions with Ethernet interface)
  • Selection of PID parameters for any unit
  • For easy programming and devices configuration, LUMEL offers one common LPCon software
  • Parameter logging on SD card

Duct temperature transducer with 4...20 mA output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Calibration certificate is included.

Duct temperature transducer with 0...10 V output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Output temperature range is user adjustable. Calibration certificate is included.

  • Temperature measurement range: -35…+80 ºC
  • Humidity measurement range: 0…100 % RH
  • Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
  • Output: Modbus RTU
  • Allowed overpressure/ bellow: ± 50 kPa
  • Operating temperature: 24 VAC / 15…35 VDC
  • Protection class: IP 65
  • Ethernet connection
  • Analog inputs: 2 (0...10 VDC)
  • Digital inputs: 2
  • Relay outputs: 2 (NO/NC)
  • 1-Wire input (up to 8 sensors)
  • Memory: 70 000 values
  • Modbus TCP/IP support
  • Webserver
  • XML/JSON, HTTP API commands
  • SNMP alarms (up to 5 recipients)
  • E-mail alarms (up to 5 recipients)
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...28 VDC
  • Ethernet connection
  • Modbus TCP/IP
  • Digital inputs: 4
  • 1-Wire input (up to 8 sensors)
  • Analog inputs: 4 (0...60 VDC)
  • Relay outputs: 4 (NO/NC)
  • Configurable inputs
  • Webserver
  • HTTP Post, HTTP API
  • E-mail alarms (up to 5 recipients), SMT with TLS support
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...28 VDC
  • Exd fire-resistant RTD temperature sensors are designed for temperature sensing in explosive atmospheres
  • Ranges: -200...+150°C; -200...+550°C; -200...+600°C
  • Outputs: RTD, 4..20 mA
  • Exd fire-resistant thermocouple temperature sensors are designed for temperature sensing in explosive atmospheres.
  • Ranges: -40...+800°C; -40...+1200°C; -40...+700°C
  • Outputs: TC, 4...20 mA
  • Exi RTD sensors for explosive atmospheres with cable
  • Range: -50 .. +400°C
  • Cable insulation: PVC, silicone, teflon, glass fiber
Exi RTD sensors for explosive atmospheres with connection head. Technical specifications Example Model Range Diameter Output XI-TOPGB / XI-APTOPGB -200 .. +150°C Ø9, Ø10, Ø11, Ø12, Ø15 mm RTD, 4..20 mA XI-TOPG / XI-APTOPG -200 .. +550°C Ø11, Ø12, Ø14, Ø15 mm RTD, 4..20 mA XI-TOPT / XI-APTOPT -200 ...
Exi RTD sensors for explosive atmospheres with mineral insulation. Technical specifications Example Model Range Diameter XI-TOPI / XI-APTOPI -200 .. +600°C Ø3, Ø4.5, Ø6, Ø8 mm XI-TRP-BTW -50 .. +600°C Ø1.5, Ø2, Ø3 mm XI-TRP-WL -50 .. +600°C Ø1.5, Ø2, Ø3, Ø4.5, Ø6 mm XI-TRP-TKbW ..
  • Exi thermocouple sensors for explosive atmospheres
  • Range: -40...+1200°C
  • Exi thermocouple sensors for explosive atmospheres with cable
  • Range: -40...+400°C
  • Exi thermocouple sensors for explosive atmospheres with connection head
  • Outputs: TC, 4..20 mA
  • Measurement distance: 0,5…2 m
  • Accuracy: ± 0,5 °C
  • Measurement speed: 0,7…2 m
  • Software: DERMALOG Fever Detection (PC required)
  • Interface: USB 3.0
  • SDK: .Net / C / C++ / (Java coming soon)
  • Measurement speed: 0,6 s (up to 700 people per hour)
  • Integrated sensors: 5
  • IR thermal array, range: 0...100 °C (± 0,3 °C)
  • Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
  • Relative humidity sensor, range: 0...100 % (± 3 %)
  • Vibration sensor (for sabotage detection), range: 0,25...5 G
  • Distance sensor, resolution: 1 mm
  • Dew point calculation
  • Relay inputs: 2
  • Relay outputs: 2
  • LED indication, buzzer (85 dB)
  • Communication: Ethernet (10/100)
  • Connector (RJ45) for connection of other Kentix devices
  • Webserver
  • Software: remote connection with AlarmManager-PRO
  • E-mail, SNMP alarms, Rest API
  • SD card slot (to save pictures, card up to 128 GB)
  • PoE
  • Optional: RFID reader
  • Optional: wall bracket, cable

Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.

  • Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
  • Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
  • CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
  • Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
  • Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
  • Air quality (VOC) measuring range: 0…100 %
  • Data output:  galvanically separated RS-485 Modbus RTU interface
  • Variants: with / without LCD display
  • One sensor covers about 30 m² of room area
  • Power supply: 24 V ac/dc (200 mA)
  • Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
  • Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
  • Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
  • Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC 
  • Applications of flue gas analyzer Si-Ca 130: for commercial and residential boilers and water heaters
  • Detectable gases: O2, CO, CO2, NO, NOx
  • Up to three gas sensors
  • CO measurement up to 8000 ppm
  • Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation)
  • Color display screen with buttons
  • Communication: Bluetooth (mobile App), remote printer
  • Measurement storage: smartphone
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Protection class: IP42
  • Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
  • Operating temperature: -5…+45 °C
  • Sensor protection by pump stopping
  • Grain temperature monitoring system for steel and concrete bins
  • Digital sensors with 2-wire bus
  • Sensor spacing: 2 or 3 m
  • Diameter: Ø9,8 mm
  • Length: 1...35 m
  • Tensile strength: ≤ 2,5 t
  • Operating temperature -20...50 °C
  • Maximal surface temperature 85 °C
  • System is ATEX-, IECEx- and GOST-R approved
  • ATEX approval code: Ex II 1D Ex ia IIIC T85°C
  • Grain temperature monitoring system for steel and concrete bins
  • Digital sensors with 2-wire bus
  • Sensor spacing: 2 or 3 m
  • Diameter: Ø17 mm
  • Length: 1...100 m
  • Tensile strength: ≤ 8 t
  • Operating temperature -20...50 °C
  • Maximal surface temperature 85 °C
  • System is ATEX-, IECEx- and GOST-R approved
  • ATEX approval code: Ex II 1D Ex ia IIIC T85°C
  • Temperature measurement range: -20...+60 °C
  • Accuracy: ±0.4 °C
  • Internal temperature sensor
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Internal sensor
  • GSM modem (GPRS)
  • SMS and JSON messages can be sent via GPRS data connection
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate of manufacturer included
  • Ambient temperature: -20...+60 °C
  • Supply: 5200 mAh LiIon battery
  • Protection class: IP67
  • Warranty: 3 years
  • Measures temperature, humidity, calculates dew point
  • Temperature measurement range: -20...+60 °C
  • Humidity measurement range: 0...100 %
  • Memory: up to 500,000 values in non-cyclic mode (350,000 in cyclic)
  • Logging interval: 10 s...24 h
  • Display and alarm refresh interval: 1 s...1 min
  • Protection class: IP67
  • Warranty: 3 years
  • Calibration certificate of manufacturer is included (according to EN ISO/IEC 17025)
  • Free analytical software COMET Vision
  • Inputs: 4x external Pt1000 sensors
    • Measuring range: -200…+260 °C
    • Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
    • Resolution: 0,1 °C
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: adjustable 1 s, 10 s, 1 min
  • GSM modem (GPRS)
  • SMS and JSON messages can be sent via GPRS data connection
  • Messages can be sent on alarms and periodically
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+60 °C
  • Supply: rechargeable Li-Ion battery A8200, 3.6V/5200mAh
  • Protection class: IP20
  • Warranty: 3 years
  • Digital inputs: 2
  • 1-Wire input (up to 8 sensors)
  • RS-485 input (up to 8 sensors)
  • Analog inputs: 4 (2 x 0...10 VDC, 2 x 0...10 VDC / 4...20 mA, WEB control)
  • Relay outputs: 4 (NO/NC)
  • Setup via USB or SMS
  • Data logger for up to 52 000 records
  • Webserver
  • Periodical upload of data logger file to a remote HTTP server
  • HTTP Post, HTTP API
  • SMS alarms (up to 5 numbers)
  • E-mail alarms (up to 5 recipients), SMT with TLS support
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...24 VDC
  • Digital inputs: 2
  • 1-Wire input (up to 4 sensors)
  • Analog inputs: 2 (0...60 VDC)
  • Relay outputs: 2 (NO/NC)
  • Setup via USB or SMS
  • Webserver
  • HTTP Post, HTTP API
  • SMS alarms (up to 5 numbers)
  • E-mail alarms (up to 5 recipients), SMTP with TLS support
  • Operating temperature: 0...40 °C
  • Warranty: 3 years
  • Supply: 10...28 VDC
  • Used with grain temperature sensor cables GWSL 1100, GWSL 2100 and spear sensors GWTL-R
  • Cable length up to 200 m (including the temperature cables)
  • Up to 32 values of temperatures are shown in cycle
  • Weight: 240 g (with batteries)
  • Case material: ABS
  • Supply: 2 x AA (battery life circa 1 year)
  • Operating temperature: -20...+40 °C

A simple handheld, accurate vape particulate, vape smoke detector FD-VAPE-HAND that indicates air quality for home, work, vehicles, or other occupational spaces. Excellent to detect vape, cigarette smoke, and e-cig smoke.

  • Sensor: Laser scattering PM1.0, PM2.5, PM10 sensor
  • Detection Range: 0-1000 µg/m3
  • Response Time: <10 seconds
  • Temperature measurement range: 0…50 °C (can be selected between Fahrenheit and Celsius)
  • Humidity measurement range: 10…95 %RH
  • Sound alarm when vape detected
  • Auto off: after 5 minutes
  • Power: 1000 mAh Li-Ion Battery, up to 8 hours of operation, (recharge USB 5V/1A)
  • Dimensions: 5,1 x 1,8 x 8,6 cm
  • Weight: 142 gr

Humidity and temperature regulator AR247 is designed for temperature and humidity control. The device is made with either integrated or cable-connected sensor. Protection class is IP65. Optionally can be ordered: RS-232 or RS-485 ports, analog output 0/4...20 mA or 0...10 VDC (for control or signal transmission).

SM400-4-TH humidity and temperature sensor supports MODBUS RTU protocol over the RS-485 interface. Suitable for environmental quality monitoring offices, server room, data center and indoor air

  • Changeable communication parameters
  • Non-volatile memory for all settings
  • Operating temperature range: -20…60°C
    • Accuracy (min): ± 0.4 °C (in -10…+ 60 °C range)
    • Accuracy (max): ± 0.6 °C (in -20…+ 60 °C range)
    • Resolution: 0.1 °C
  • Operating relative humidity range: 10…90% (non-condensing)
    • Accuracy (min): ± 3.0 % RH (in 20…80 % RH range)
    • Accuracy (max): ± 5.0 % RH (in 10…90 % RH range)
    • Resolution: 0.1 % RH
  • Ingress protection: IP20
  • Operating voltage range: 4.5…26 VDC
  • Temperature measurement range: 0...50 °C
  • Humidity measurement range: 0...100 %
  • Output: 2 x 0...10 V / 2...10 V / 4...20 mA
  • Option: LCD display
  • Option: relay output
  • Option: Modbus RTU
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...50 °C
  • Protection class: IP20
  • Temperature measurement range: 0...50 °C
  • Humidity measurement range: 0...100 %
  • Output: 2 x 0/2...5/10 VDC
  • Option: LCD display
  • Option: Modbus RTU
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...50 °C
  • Protection class: IP54
  • Temperature measurement range:
    a) Ambient model: -20...+80 °C
    b) Remote model with polycarbonate probe: -20...+80 °C
    c) Remote model with stainless steel probe: -40...180 °C
  • Relative humidity measurement range: 0...100 %
  • Calculates dew point, absolute humidity, enthalpy and combination ratio
  • 4-wire analog output: 0...5/10 V or 0/4...20 mA
  • 2 relay outputs
  • Versions with or without display
  • Protection class: IP65 (ABS V0 housing)
  • Universal input for measuring temperature, resistance and standard signal
  • 4 alarm outputs with signaling on LED diodes
  • Digital output: RS-485 modbus (can be programmed through RS-485)
  • Analog signal output: 0/4...20 mA or 0...10 V
  • Two-line LCD display
  • Mathematical functions for converting the measured value
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C

Digital programmable indicator N20 for temperature, DC voltage and current measurement. Measures J, K, Pt100 temperature sensors’ signals.

 

Programmable parameters:

  • LED indicator color, which changes depending on input signal value: green, yellow and red
  • Value limits
  • Measurement unit indication
  • Cold junction compensation (CJC)
  • Compensation for Pt100 sensors
  • Averaging time
  • Individual characteristic
  • 2 OC alarms in 6 modes

Digital programmable indicator N24 for temperature, AC/DC voltage and current measurement. Measures J, K, Pt100 temperature sensors signals.

 

Programmable parameters:

  • Value limits
  • Decimal point place
  • Measurement unit indication
  • Cold junction compensation (CJC)
  • Compensation for Pt100 sensors
  • Averaging time
  • Individual characteristic

Indoor temperature meter / transducer Txx18, designed for temperature, humidity and barometric pressure measurement.

Inserts for thermocouple sensors (changeable, with ceramic block). Technical specifications Example Model Range Sensor Accuracy Measuring tube   w2 -40 ... +1150°C K (NiCr-NiAl),J (FeCu-Ni)  1 class (standard)or 2 according to EN 60751   INCONEL 600 w4 0 ... +1800°C ceramics C610 ir C79..
  • Ethernet connection
  • Digital inputs: 2
  • 1-Wire input (up to 2 sensors)
  • Analog inputs: 2 (0...60 VDC)
  • Relay outputs: 2 (NO/NC)
  • IP watchdog function
  • Webserver
  • SNMP alarms
  • VLAN and MAC address filtering
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...14 VDC
  • SpotScan is a linear scanning add-on for RAYTEK, IRCON noncontact IR thermometers ENDURANCE, Marathon MM, Modline 5 and Modline 7

  • SpotScan is designed to broaden the capabilities of noncontact IR thermometers while scanning measured surface linearly thus measuring wider than one dot target area

The enLink Status-T transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • External sensor measurement range: -55…+125 °C
    • Accuracy: ± 0.5 °C (-10…+85 °C)
  • Up to two probes (cable length: 1 m, others on request)
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours or adaptive (triggered by alarm)
  • 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
  • Configuration via USB cable / downlink
  • Each sensor can be programmed individually for different alarm type: No alarming, High threshold alarm, Low threshold alarm, In band alarm, Out of band alarm
  • Each alarm type has an individual alarm status message with the following parameters: Alarm status, Total number of alarm activations, Alarm duration
  • Case IP40 protection (IP 67 on request)

The Wx9xx series of sensors from COMET SYSTEM enables accurate measurement of temperature, relative humidity, and atmospheric pressure, with data transmitted via the low-power LoRaWAN network. This technology allows data to be sent to a cloud storage, where users can easily view both current and historical values through a standard web browser. Each sensor has an LCD display showing the measured value and battery status.

  • Possibility to connect Pt1000 sensors
  • Covers up to 15 km in rural areas and 2…5 km in urban areas
  • Work with Comet System LoRaWAN gateway SP041
  • Battery life: from 1 to 10 years depending on transmission time and environment temperature
  • Unlimited space for data in cloud
  • Alarm: email and app notification
  • Mobile applications for Android and iOS
  • Measurement range: -40...+150 °C, -1...60 bar
  • Temperature measurement accuracy: ± 1,3 °C
  • Pressure measurement accuracy: ±0,5 % of full scale
  • Operating temperature: -20...+50 °C
  • Overload: 65 bar
  • Two valve system
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases
Non-reversible temperature labels, 10 temperature ranges.  A °F°C 10440  10842 11144 11546 12049 12954 14060 14462 14965 16071  B °F°C  17177 18082 19088 19993 21099 ..

Digital meters – bargraphs NA3, NA5, NA6,measurement of DC voltage, current, resistance and temperature measurement (with thermal sensors J, K, N, E, R, S, T, Pt100, Pt500, Pt1000).

  • Temperature sensor AUREGIS TJ-2 with mineral insulation is inextricably connected to the cable
  • It is designed for temperature measurement from -50°C to 550°C for RTD sensors Pt100, Pt1000 and from -50°C to 1150°C - for thermocouples
  • Various sizes are available depending on customer requirements and drawings
  • Mounting brackets for easy installation of temperature sensors in measuring point
  • UZ11 – full bracket
  • UZ21 – bracket without body (only flange)
  • Diameter: 15 / 22 / 32 mm
  • Body and flange material: 1.0401 steel
  • Sealing part material: Teflon / glass fiber
  • High quality
  • Complies with DIN EN 50 446

The Triton ULTRA is a multifunctional vape sensor capable of detecting e-cigarette vapor, marijuana smoke (THC), smoking, loitering, the number of people, gunshots, loud noise, and glass breakage.

  • Measured parameters: Temperature, humidity, PM1.0, PM2.5, PM10, TVOC, CO2, NO2, CO, HCHO, sound level
  • Customizable instant alarms based on the situation: Email notification, loud alarm, lights, *integration
  • Tamper protection: device vandalism, masking and covering
  • Real-time monitoring of student loitering via live video streaming
  • No license subscription required for use
  • The sensor independently performs all measurements and detections and sends alarms itself
  • *Integration capability with many third-party systems: TCP, HTTP, MQTT, RTSP
  • Event logging of alarms in the device
  • Communication: LAN, WiFi
  • Operating environment temperature / humidity: 0...44 °C / 0...90% RH (non-condensing)
  • Power supply: PoE+ (IEEE 802.3at Class 3 compliance). Ability to connect up to 4 devices in series
  • Temperature sensor: HQ digital internal or optional external sensor*
  • Temperature measurement range: -30...+70 °C (-40...+90 °C with ext T sensor) (-80...+200 °C with ext Pt100 sensor)
  • Accuracy: ±0.3 °C (-20...+40 °C); ±0.5 °C
  • Memory: 60,000 values ​​(up to 6 months)
  • Display: multifunction LCD
  • Battery: CR2450 3V
  • Dimensions: 100mm x 53mm x 12mm (L x W x H)
  • Weight: 54 g
  • Protection class: IP65
  • Automatic PDF, CSV reporting: Yes
  • Connection interface: USB 2.0, A-Type
Loading...