  • Sturdy
  • Hanging hook
  • 3 'Y' ¼” 'MFL connectors including one with a Schrader valve
  • Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
  • THD factor
  • Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
  • Digital output: RS-485 MODBUS (option)
  • Protection class for front side: IP65
  • Supply: 85...253 VDC/VAC
  • Backlit LCD display
  • Dimensions: 96 x 96 x 77 mm
  • T22CT can be used for network analysis, monitoring and measuring of non -sinusoidal and distorted networks AC current
  • Variations of measuring current range (A): 0...50 / 100 / 150 / 200 / 250 / 300 / 400 / 500 / 600 / 750
  • Output: 4…20 mA or 0…20 mA (Proportional change to input current)
  • Frequency range of Measuring current: 50…60 Hz
  • High electric isolation between primary conductor and output
  • Mounting onto 35 mm DIN rail by means of optional supply of snap on mounting
  • Auxiliary power supply: 24 V DC, ± 15%
  • Protection class: IP20
  • Operating temperature and Humidity: 0…+70 °C, 0...95% RH without condensation
  • Portable, small dimension temperature meter with a probe
  • The probe can be 1,5 m, 3 m or of specified length
  • Temperature measurement accuracy: ±1 °C
  • Temperature measurement range: -50...+150 °C
  • LCD screen
  • 2 year warranty
  • Supply: 1x6LF-22 (9 V)
  • Maximal pressure measurement range: 0...7000 Pa
  • Air flow and velocity measurement
  • LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 9 V battery
  • Operating temperature: 10...+50°C
  • Protection class: IP54

Bimetallic ammeters BA27, BA39, BE27, BE39 indicate flowing current and maximal flown current. When the user presses the button on the front of ammeter, maximal current indication arrow returns to the actual value.

BE27 and BE39 additionally indicate average current of 8-15 minute timespan. They are fit to indicate thermal current indication in transformers, cables and other electric devices. Measuring range can be extended according to customer’s demand.

  • Panel electromagnetic devices are designed to measure effective values of current and voltage
  • The devices are fit to be mounted in up to 15 mm-thick panels
  • Meter EB16 is mounted on 35 mm rail
  • Tropical version is also available
  • Ammeters for use with transformers (X/1A and X/5A) available
  • Panel devices are designed to measure AC and DC current and voltage
  • Those with P index have integrated rectifier which enables the device to measure effective currents and voltages
  • Asymmetric form signal measurement accuracy depends on harmonic component levels
  • The devices are fit to be mounted in up to 15 mm-thick panels
  • Meter MB16 is mounted on 35 mm rail
  • Tropical version is also available
  • Ammeters for use with transformers (X/1A and X/5A) available

Antenna radar level meter ARLM-54 designed for reliable level measurement of various liquids and pasty.

  • Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
  • Intelligent numerical signal processing with false reflection elimination
  • Measuring range up to 8 m or up to 20 m
  • Current output - 4...20 mA, HART communication
  • Measurement independent of temperature and pressure of the atmosphere above the surface
  • Possibility to measure even in aggressive vapors
  • Operating temperature: -30…+70 °C
  • Protection class: IP68
  • Antenna radar level meter ARLM-70 "AMANDA" designed for reliable level measurement of various liquids
  • Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
  • FMCW antenna radar level gauge with a range of up to 20 m
  • Teaching function to suppress false reflections
  • Display of measured values on matrix OLED or LCD display
  • Current output - 4...20 mA, HART communication
  • Manual or remote adjustment
  • Measurement independent of temperature and pressure of the atmosphere above the surface
  • Possibility to measure even in aggressive vapours or vacuum
  • Operating temperature: -30…+70 °C
  • Measures ambient air pressure
  • Measurement range: 600...1100 hPa
  • Operating temperature: -30...80 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • CLM-70 for continuous level measurement of liquids, bulk solids in all industrial branches
  • Stainless steel design suitable for the food and pharmaceutical industries
  • Output: 4...20 mA with two-way HART
  • Process connection: G1”, G1 ½”, NPT 1" threads and Tri-Clamp (Ø 50.5 or 64 mm)
  • Arbitrary electrode length (up to 20 m)
  • Display of measured values on matrix OLED or LCD display
  • Power supply: 18…36 V DC
  • Protection class: IP67
  • Measures carbon dioxide concentration in air
  • Measurement range: 0...2000 ppm
  • Operating temperature: -30...60 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air
  • Measurement range: 0...10000 ppm
  • Operating temperature: -30...80 °C
  • Cable length: 1 / 2 / 5 / 10 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air
  • Duct mount
  • Measurement range: 0...2000 ppm
  • Operating temperature: -30...60 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air, temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: 0...2000 ppm, -30...+80 °C, 5...95 %RH
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s; CO2: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air, temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: 0...10000 ppm, -30...+105 °C, 5...95 %RH
  • Temperature and humidity sensor cable length: 1 / 2 / 4 m
  • Carbon dioxide concentration sensor cable length: 1  2 / 5 / 10 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s; CO2: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measurement range: -40...+150 °C, -1...60 bar
  • Temperature measurement accuracy: ± 1,3 °C
  • Pressure measurement accuracy: ±0,5 % of full scale
  • Operating temperature: -20...+50 °C
  • Overload: 65 bar
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases

Temperatre, humidity and pressure meters, loggers Cxxxx, Dxxxx.
Cxxxx are designed for indication (without data logging), Dxxxx indicates and logs listed parameters.

  • Compact air flow meter with switching output (1 NO)
  • Robust sensor design, protection class IP67 and compact dimensions
  • Switching point continuously adjustable between 0.1...15 m/s (extended measuring range available with RLSW5)
  • Exemplary areas of application: monitoring of fans, heating registers, extraction, soldering and air curtain systems
  • Compact air flow meter with switching output (1 NO / 1 NC) with TÜV type examination (according to DIN EN 61010-1: 2011-07)
  • Robust sensor design, protection class IP67 and compact dimensions, sensitive and fast air flow detection
  • Media temperature up to 60 °C
  • Switching point continuously adjustable between 0.1...30 m/s
  • Exemplary areas of application: Visualization and control of air flows in building automation, filter and fan monitoring as well as in industrial applications such as catalytic converters
  • Compact air flow meter with analogue output (0…10 V & 4…20 mA)
  • Robust sensor design, protection class IP67 and compact dimensions
  • Media temperature up to 70 °C
  • Switching point continuously adjustable between 0.1...30 m/s
  • Exemplary areas of application: Visualization and control of air flows in building automation, filter and fan monitoring as well as in industrial applications such as catalytic converters

Compact sensor VA 525 for measuring compressed air or nitrogen inline.

  • 4...20 mA and pulse or a Modbus RTU (RS 485) interface as standard
  • Optional interfaces such as Modbus TCP (Ethernet), PoE, M-Bus available
  • Pressure range up to 16 bar
  • Temperature range up to 60°C
  • For speeds up to 224 Nm/s
  • Integrated display to show the measured values
  • Available from 1/4" to 2''
  • Settings adjustable via the keys of the display
  • Main counter can be reset via the display
  • Measurement range: 32…43 °C
  • Measurement accuracy: ± 0,3 °C
  • Measurement distance: 0…5 cm
  • Measurement duration: 1 s
  • Measurement location: forehead
  • Automatic shut-down: 30 s
  • Measurements: 149 x 38 x 42 mm
  • Operating temperature: 10…40 °C
  • Operating humidity: ≤ 85 %
  • Certificates: ISO13485, CE, CFDA
  • Supply: 2 x AAA batteries
Data logger for lever measurement DL/N -35%
  • Data logger for level measurement up to 100 m
  • Measuring interval: from 0,5 s to 24 hours
  • Data capacity: up to 500 000 values
  • Interface: RS-485
  • Ambient temperature: -5...50 °C
  • Protection class: IP67
  • Sensor material: stainless steel 1.4435 (316L)
  • Supply: 3,6 V lithium battery
  • Included: 110 m PE cable, RS-485 converter, software
1,185.80 € 770.77 €
Ex Tax: 637.00 €
  • Range: from 0....60 to 0...5 kPa
  • Accuracy: ±2% (FS 20°C)
  • Allowed overpressure: 20 kPa
  • Operating temperature: -5...+60°C

Differential manometer DPG/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.

  • Range: 0…1500 Pa
  • Switch activation range: 20…1500 Pa
  • Operating temperature: -5… +60°C

Differential manometer MM for air and non-aggressive gasses, designed for pressure measurement in narrow ranges.

  • Range: -100…1500 Pa
  • Operating temperature: -40… +60°C

Differential manometer MM/PS for air and non-aggressive gasses, designed for pressure monitoring and control. Used in ventilation and conditioning systems for filter permeability control.

  • Range: 0…1500 Pa
  • Switch activation range: 40…1500 Pa
  • Operating temperature: -20… +60°C
  • Multimeter with backlit LCD screen (two shown values)
  • Four versions: NP10-2, NP10-3, NP10-5, NP10-6 TRMS (see datasheet below)
  • Capacity measurement from 1 pF to 40 mF
  • AC and DC voltage measurement from 100 μV to 1000 V
  • AC and DC current measurement from 10 μA to 10 A
  • Resistance measurement from 100 mΩ to 60 MΩ
  • Frequency measurement from 10 Hz to 10 MHz
  • Diode measurement and continuity testing
  • Hold function
  • Relative measurement
  • Duty cycle (%) measurement
  • Temperature measurement (K type thermocouple) from 0 to 1300 °C
  • Peak value measurement
  • Digital multimeter with data logging view function (up to 32000 readings) 
  • Four versions: NP15-2, NP15-3, NP15-5, NP15-6 TRMS (see datasheet below)
  • TRMS measurement
  • Low input impedance
  • Capacity measurement from 1 pF to 40 mF
  • AC and DC voltage measurement up to 1000 V
  • AC and DC current measurement up to 10 A
  • Resistance measurement
  • Frequency measurement
  • Diode measurement and continuity testing
  • Filtering
  • Square wave signal generator
  • Hold function, backlight, maximal and minimal value presentation
  • External supply
  • Duty cycle (%) measurement
  • Temperature measurement (K, J type thermocouples, Pt100 and Pt1000)
  • Automatic / manual range selection
  • USB connectivity (optional)
  • Digital multimeter for insulation resistance measurement
  • Multimeter with backlit LCD screen
  • AC and DC voltage measurement up to 1000 V
  • AC and DC current measurement up to 300 mA
  • Resistance measurement up to 30 mΩ
  • Insulation resistance measurement up to 3 GΩ
  • Capacitance measurement up to 30 μF
  • Frequency measurement up to 100 kHz
  • Fill factor measurement (%)
  • Hold function
  • Temperature measurement (Pt100 and Pt1000)
  • Diode check
  • Analog scale on screen

 

  • Outputs 0...10 V, 0...20 mA
  • Display LED 4 digits, 14 mm height

 

  • Output 0...20 mA
  • Display LED 4 digits, 14 mm height

 

 

  • Digital pulse counter - tachometer ECH4400
  • Count inputs: 2 channels (max 50 kHz, 5…30 V pulses), can be selected as PNP or NPN input
  • Counting frequency: (20, 50, 100, 500, 1000, 5000) Hz, (10, 20, 30, 40) kHz
  • Control outputs: 2 relay NO / NC 250 V, 2 A
  • SSR outputs: Open collector output (Max.: 30 VDC, 50 mA)
  • RS485 Modbus communication interface (custom ordered)
  • Power supply: 90…250 V AC; 10…30 V DC; 8…24 V AC (custom ordered)
  • Auxiliary supply output: 12 VDC, max 50 mA
  • Ambient temperature: 0…+50 °C
  • Case protection: front panel IP65, rear panel IP20

Digital thermometer SDT8 for temperature measurement from -50 to +150 °C.

  • Temperature range: -30...70 °C
  • Accuracy: ±0,5 °C (-10 °C...40 °C) / ± 1 °C
  • Display: LCD
  • Battery work time: 2 years
  • Battery type: 1/2 AA (3,6 V)
  • Dimensions: 45x100x19 mm
  • Protection class: IP65
  • Weight: 85 g
  • Holder is ordered separately
  • Measurement of 85 power network parameters, including current and voltage harmonics up to 31st in 1-phase 2-wire or 3-phase 3 or 4-wire.
  • Accuracy of active energy measurement 0.5S or 0.2S
  • RS-485 (Modbus RTU) interface for remote monitoring of measured parameters
  • The dual-tariff function for energy billing applications
  • 2 relay outputs
  • Pulse output: SO output as pulse or alarm
  • 2 digital inputs as energy consumption, pulse counting and contact status
  • Measured values displayed in 10 configurable screens
  • Possibility programming of current and voltage ratio without restrictions as in MID-certified products
  • Measurement inputs dedicated for x/1A and x/5A current transformers
  • Power supply: 100…550 V a.c. / d.c.
  • DIN rail mounted
  • Measurement distance: 0,5…2 m
  • Accuracy: ± 0,5 °C
  • Measurement speed: 0,7…2 m
  • Software: DERMALOG Fever Detection (PC required)
  • Interface: USB 3.0
  • SDK: .Net / C / C++ / (Java coming soon)
  • Measurement speed: 0,6 s (up to 700 people per hour)
  • Integrated sensors: 5
  • IR thermal array, range: 0...100 °C (± 0,3 °C)
  • Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
  • Relative humidity sensor, range: 0...100 % (± 3 %)
  • Vibration sensor (for sabotage detection), range: 0,25...5 G
  • Distance sensor, resolution: 1 mm
  • Dew point calculation
  • Relay inputs: 2
  • Relay outputs: 2
  • LED indication, buzzer (85 dB)
  • Communication: Ethernet (10/100)
  • Connector (RJ45) for connection of other Kentix devices
  • Webserver
  • Software: remote connection with AlarmManager-PRO
  • E-mail, SNMP alarms, Rest API
  • SD card slot (to save pictures, card up to 128 GB)
  • PoE
  • Optional: RFID reader
  • Optional: wall bracket, cable

Frequency meters CA32, CA36, CA37, CA39, CA39L are designed for frequency measurement in electrical grid. Transducer signal is measured using magnetoelectric effect. Tropical version available.

  • Frequency range: 45...55, 45...65, 48...52, 55...65, 360...440, 380...420 Hz
  • Voltage range: 60,100, 110, 230, 240, 400, 415, 440, 500 ± 20%
  • Accuracy class: 0,5
  • Consumed power: =< 7 VA
  • Protection class: IP52 or IP65
  • Standards conformed: EN61000-6-2, EN-61000-6-4, EN-61010-1
  • Temperature range: 5...23...40 °C
  • Fuel sawdust moisture meter WTR-2A is designed to measure moisture of sawdust, scobs, wood shavings, slivers and other finely crumbled wood waste used as fuel
  • Range: 35...85 %
  • Sample volume: 120 cm2
  • Measuring sample: 0,2 MPa
  • Portable, small dimension grain moisture meter
  • The sample is ground, increasing the measurement accuracy
  • External probes can be connected
  • Temperature measurement accuracy: ±0,5 °C
  • Moisture measurement accuracy: ±0,5 %
  • Automatic temperature compensation
  • Calibrated for more than 400 grain species
  • 2” LCD screen
  • USB connection for software updates and data transfer
  • Supply: 4xAA (1,5 V), 1xCR2032 (3 V)
  • Portable, small dimension grain moisture meter
  • Temperature measurement accuracy: ±0,5 °C
  • Moisture measurement accuracy: ±1 % (in range up to 10 %)
  • Calibrated for more than a hundred grain types (the list can be extended)
  • Automatic temperature compensation
  • 2” LCD screen
  • USB connection for software updates
  • Supply: 2xAA (1,5 V, LR6)
  • Portable, small dimension grain moisture meter
  • The sample is ground, increasing the measurement accuracy
  • Temperature measurement accuracy: ±0,5 °C
  • Moisture measurement accuracy: ±0,5 %
  • Calibrated for more than 400 grain types
  • Automatic temperature compensation
  • 2” LCD screen
  • USB connection for software updates
  • Supply: 1x6LF-22 (9 V)
Hay and straw moisture and temperature meter DRAMINSKI HMM works by measuring electrical conductivity variation. HMM measures hay/straw moisture and indicates it on the LCD screen. Measured value is shown in percentage. Device can measure temperature. Has internal memory which stores last 50 measurements. Shows maximal, minimal and average values.  Technical parameters Measuring range:       Moisture       Temperature 10...80% 1…100°C ..
  • Portable, small dimension grain moisture meter
  • The sample is ground, increasing the measurement accuracy
  • Temperature measurement accuracy: ±1 °C
  • Moisture measurement accuracy: ±0,5 %
  • Automatic temperature compensation
  • LCD screen
  • Supply: 4xAA (1,5 V), 1xCR2032 (3 V)
  • G-7 is designed for moisture measurement of grain
  • Moisture measurement range: 9...30 %, depends on grain type
  • Built-in calibrations for barley, coffee, corn, flax, hay, oats, pasta, rapeseed, rough rice, rye, sorghum, soybeans and wheat
  • Built-in temperature correction over the range of 0...70 °C
  • Programmable offset to match elevator
  • Stores up to 150 accumulated readings in user-defined batches by grain
  • Displays the average and highest readings, standard deviation, co-efficient of variance oh stored readings
  • Built-in connector accepts any Delmhorst electrode
  • Built-in calibration check
  • Audible, adjustable alarm
  • Size: 180 x 150 x 140 mm
  • Weight: 1800 g
  • Rugged construction ensures years of reliable use
  • Supply: 9 V battery
  • 1-year warranty

Automatic portable solid state particle (dust) meter EMIOTEST 3114 is designed for periodic solid state particle concentration measurement in closed channels, i.e. flue gas, and perform other functions:

  • Periodic measurement of solid state particle concentration in stationary sources of emission
  • Solid state particle concentration measurement in gasses
  • Testing of dust removal equipment
  • Gas flow rate measurement
  • Calibration and periodic control of automatic systems (AMS) by measuring the emission and mass stream of dust
  • Dioxins, furans, PAH, mercury concentration measurement
  • Heavy meal, HCL, HF concentration measurement
  • Designed to measure the moisture of hay and straw
  • Moisture measurement method: resistive
  • Moisture range: 8...50 %