This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Поиск

Критерии поиска

Товары, соответствующие критериям поиска

Показать:
Сортировка:

TSV202-60 ideal for monitoring battery banks, solar panels, industrial control circuits, and other high-voltage applications.

  • Dual channel input: 0…60 V
  • Communication interface: 1-Wire protocol
  • Accuracy: ±1%
  • Resolution: 0.001V
  • Galvanic isolation between the voltage circuit and 1-Wire bus
  • Operating environment: -20…+60 °C / 10…90 %RH
  • Warranty: 3 years
  • Dual channel input: 0…24 mA or 0…10 V
  • Communication interface: 1-Wire protocol
  • Accuracy: ±1 %
  • Resolution: 0.001mA / 0.001 V
  • Galvanic isolation between the current circuit and 1-Wire bus
  • Detection of special states such as sensor errors or calibration values
  • Operating environment: -20…+60 °C / 10…90 %RH
  • Warranty: 3 years
  • Digital inputs: 2
  • 1-Wire input (up to 8 sensors)
  • RS-485 input (up to 8 sensors)
  • Analog inputs: 4 (2 x 0...10 VDC, 2 x 0...10 VDC / 4...20 mA, WEB control)
  • Relay outputs: 4 (NO/NC)
  • Setup via USB or SMS
  • Data logger for up to 52 000 records
  • Webserver
  • Periodical upload of data logger file to a remote HTTP server
  • HTTP Post, HTTP API
  • Communication: 4G-LTE, 3G-WCDMA
  • SMS alarms (up to 5 numbers)
  • E-mail alarms (up to 5 recipients), SMT with TLS support
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...28 VDC
  • Input voltage range: 0…264 Vac or 0…370 Vdc
  • Input frequency: 0…60 Hz
  • Input resistance: >2.4 MOhm
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • True RMS measurement
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…28 Vdc
  • Warranty: 3 years
  • Voltage being detected in one of two ranges: 85...250 VAC or 170...250 VAC (settable by jumper)
  • Galvanic isolation between the input voltage and output (OC)
  • Low temperature drift
  • Supplied by detected voltage
  • Warranty: 3 years
  • Ethernet connection
  • Analog outputs: 2 (0...20 mA / 4...20 mA / 0...24 mA / 0...5 V / 0...10 V)
  • Digital outputs: 4 (PWM / ON/OFF)
  • Relay outputs: 2 (NO/NC)
  • Modbus TCP/IP support
  • Webserver
  • XML/JSON, HTTP API commands
  • SNMP alarms (up to 5 recipients)
  • Operating temperature: -10...55 °C
  • Warranty: 3 years
  • Supply: 10...28 VDC

The mini-size multimeter has multiple functions, such as auto range, auto scan (SMART) and true RMS functions, which makes it more convenient and intelligent. Besides normal multimeter function, it also has the function of NCV test and LIVE wire test, which is convenient for field testing. Blacklight and Flashlight capabilities facilitate use in dark work environment.

  • CAT III 600V
  • TRMS
  • AC/DC Voltage measurement: 400 mV…400 V
  • AC/DC Current measurement 40 mA … 10 A
  • Resistance measurement 400 mΩ … 40 MΩ
  • Capacitance measurement 4 nF…4 mF
  • Frequency measurement
  • Temperature measurement -200…1200 °C
  • Auto Scan function (SMART)
  • HOLD function, Continuity test and Diode test
  • Dimensions: 130 x 62 x 27 mm
  • Module is designed to protect battery if it discharges below 10,5 V mark, disconnecting it from load
  • Battery is automatically reconnected to load if its voltage rises
  • Suitable for work with heaters, lighting, travel refrigerators, etc.
  • Operating voltage: 12 V ZBxx, 24 V ZBxx-24V, 48 V ZB-48V
  • Maximal current: 40 A ZB40, 80 A ZB80, 140 A ZB140
  • Operating temperature: -20...50 °C
  • Dimensions: 65 x 89 x 70 mm

The VA702 is a Volt/mA/TC Calibrator, designed as a source and measurement tool. It measures or outputs a 0 to 24 mA DC current loop, 0 to 20 V DC voltage, and supports thermocouple temperature measurements (model dependent). Note: The calibrator cannot measure and source simultaneously.

  • Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
  • Storage temperature: -40℃ to 60℃
  • Operating temperature: -10℃ to 50℃
  • Operating altitude: Up to 2000 meters
  • Temperature coefficient: ±0.01% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
  • Relative humidity:
    • 95% up to 30℃
    • 75% up to 40℃
    • 45% up to 50℃
    • 35% up to 55℃
  • Power requirements: 6 x AAA batteries
  • Size: 204mm (L) x 99mm (W) x 46mm (H)
  • Weight: 460g (including battery)

The VA700 Loop Calibrator is a versatile source and measurement tool. It is designed to measure or output a 0 to 24 mA DC current loop and 0 to 20 V DC voltage. The calibrator cannot measure and source simultaneously.

  • Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
  • Storage temperature: -40℃ to 60℃
  • Operating temperature: -10℃ to 55℃
  • Operating altitude: Up to 3000 meters
  • Temperature coefficient: ±0.005% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
  • Relative humidity:
    • 95% up to 30℃
    • 75% up to 40℃
    • 45% up to 50℃
    • 35% up to 55℃
  • Shock: Random 2g, 5Hz to 500Hz
  • Safety: 1 meter drop test
  • Power requirements: 6 x AAA batteries
  • Size: 204mm (L) x 99mm (W) x 46mm (H)
  • Weight: 460g (including battery)
  • Voltage range: 0,2...1000 V
  • Current range: 20 mA...20 A
  • Frequency range: 40...5000 Hz
  • DC voltage and currency accuracy: 0,02 %
  • AC voltage and currency accuracy: 0,05 %
  • Load capacity up to 40 VA
  • USB, RS232 interfaces
  • Ambient temperature: 23 °C ±5 °C

Portable calibrator for DC voltage and current.

 

Purpose:

  • Calibration and verification of temperature measurement equipment
  • Measurement and control equipment monitoring
  • Current loop circuit monitoring
  • Measurement of 85 power network parameters, including current and voltage harmonics up to 31st in 1-phase 2-wire or 3-phase 3 or 4-wire.
  • Accuracy of active energy measurement 0.5S or 0.2S
  • RS-485 (Modbus RTU) interface for remote monitoring of measured parameters
  • The dual-tariff function for energy billing applications
  • 2 relay outputs
  • Pulse output: SO output as pulse or alarm
  • 2 digital inputs as energy consumption, pulse counting and contact status
  • Measured values displayed in 10 configurable screens
  • Possibility programming of current and voltage ratio without restrictions as in MID-certified products
  • Measurement inputs dedicated for x/1A and x/5A current transformers
  • Power supply: 100…550 V a.c. / d.c.
  • DIN rail mounted
  • Analog inputs: 6 (0...10 VDC / 4...20 mA, configurable, isolated)
  • Digital inputs: 4 (isolated)
  • RS-485 input (up to 24 Modbus RTU registers)
  • Memory: 70 000 values
  • Ethernet connection
  • Modbus RTU to Modbus TCP conversion
  • Webserver
  • Periodical upload of data logger file to a remote HTTP server
  • HTTP Post, HTTP API
  • SNMP alarms (up to 5 recipients)
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...28 VDC
  • Ethernet connection
  • Analog inputs: 2 (0...10 VDC)
  • Digital inputs: 2
  • Relay outputs: 2 (NO/NC)
  • 1-Wire input (up to 8 sensors)
  • Memory: 70 000 values
  • Modbus TCP/IP support
  • Webserver
  • XML/JSON, HTTP API commands
  • SNMP alarms (up to 5 recipients)
  • E-mail alarms (up to 5 recipients)
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...28 VDC
  • Ethernet connection
  • Modbus TCP/IP
  • Digital inputs: 4
  • 1-Wire input (up to 8 sensors)
  • Analog inputs: 4 (0...60 VDC)
  • Relay outputs: 4 (NO/NC)
  • Configurable inputs
  • Webserver
  • HTTP Post, HTTP API
  • E-mail alarms (up to 5 recipients), SMT with TLS support
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...28 VDC
  • Digital inputs: 2
  • 1-Wire input (up to 8 sensors)
  • RS-485 input (up to 8 sensors)
  • Analog inputs: 4 (2 x 0...10 VDC, 2 x 0...10 VDC / 4...20 mA, WEB control)
  • Relay outputs: 4 (NO/NC)
  • Setup via USB or SMS
  • Data logger for up to 52 000 records
  • Webserver
  • Periodical upload of data logger file to a remote HTTP server
  • HTTP Post, HTTP API
  • SMS alarms (up to 5 numbers)
  • E-mail alarms (up to 5 recipients), SMT with TLS support
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...24 VDC
  • Digital inputs: 2
  • 1-Wire input (up to 4 sensors)
  • Analog inputs: 2 (0...60 VDC)
  • Relay outputs: 2 (NO/NC)
  • Setup via USB or SMS
  • Webserver
  • HTTP Post, HTTP API
  • SMS alarms (up to 5 numbers)
  • E-mail alarms (up to 5 recipients), SMTP with TLS support
  • Operating temperature: 0...40 °C
  • Warranty: 3 years
  • Supply: 10...28 VDC
  • Voltage measurement ± 600 V, current measurement via shunt, power, energy and capacity measurement of d.c. circuits
  • 4 alarm outputs with signaling on led diodes, working in 7 different modes
  • Analog outputs: 0/4...20 mA or 0...10 V
  • Digital output: RS-485 / MODBUS RTU
  • Two-line LCD display
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -25...23...55 °C

N19Z meter measures AC voltage and current. The meter is designed to work in 3-phase networks or 1-phase networks.

  • Nominal input voltage: 300 or 600 V 1 phase / 100…500 V 3 phase
  • Nominal input current: 1A or 5A
  • True RMS measurement (up to 15th Harmonic)
  • On site programmable PT/CT ratios
  • User selectable 3ph3wire or 3ph4wire Network (for 3ph)
  • Onsite selection of Auto scroll / Fixed Screen (for 3ph)
  • 4 Digits 14mm ultra bright LED Display
  • Protection: IP54 front / IP20 back
  • Parameter Screen recall: In case of power failure, the instrument memorizes the last displayed screen
  • Accuracy: ±0.5% of nominal value
  • Ethernet connection
  • Digital inputs: 2
  • 1-Wire input (up to 2 sensors)
  • Analog inputs: 2 (0...60 VDC)
  • Relay outputs: 2 (NO/NC)
  • IP watchdog function
  • Webserver
  • SNMP alarms
  • VLAN and MAC address filtering
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...14 VDC

The enLink Status-VC transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • 0…20 mA, 0…10 V or resistance input
  • 12 bit resolution
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours
  • 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
  • Configuration via USB cable / downlink
  • Case IP40 protection (IP 67 on request)
  • 10 time functions. With control signal and without additional signal
  • 10 time ranges. Ranging from 0,1 sec. to 30 hours
  • Operating voltage: 12…240 V AC / DC
  • Operating power: < 4 VA
  • Mounting on DIN rail
  • Operating temperature: -20…+55 °C

Applications:

Surge protection for 2 pair lines or 4 single lines with common reference potential in the data, signal and communication systems: 0-20 mA, 4-20 mA current loop, TTY 4-20 mA, TTY, TTL, V24 (RS232C), high-frequency transmission system.

Specifications:

  • ANSI / IEEE C62.41 category: B, C
  • Rated operating voltage Un 24 V DC
  • Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
  • Rated load current at 25°C IL 1 A
  • Nom. discharge current (8/20 μs) In 10 kA
  • Max. discharge current (8/20 μs) Imax 20 kA
  • D1 current impulse (10/350 μs, per line) 2,5 kA
  • Voltage protection level Up:
    • at In, C2 (8/20 μs, line-line, line-PG) ≤ 55 V
    • at C3, 1 kV/µs (line-line, line-PG) ≤ 48 V
  • Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019

Applications:

surge protection for 2 pair lines of closed circuit (loops) in the data, signal and communication systems: 4-20 mA current loop, analog/digital communication, RS485, RS422 (V11) interface, high-frequency bus system, 2 wires video transmission system.

Specifications:

  • ANSI / IEEE C62.41 category: B, C
  • Rated operating voltage Un 24 V DC
  • Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
  • Rated load current at 25°C IL 1 A
  • Nom. discharge current (8/20 μs) In 10 kA
  • Max. discharge current (8/20 μs) Imax 20 kA
  • D1 current impulse (10/350 μs, per line) 2,5 kA
  • Voltage protection level Up:
    • at In, C2 (8/20 μs, line-line) ≤ 55 V
    • at In, C2 (8/20 μs, line-PG) ≤ 500 V
    • at C3, 1 kV/µs (line-line) ≤ 48 V
    • at C3, 1 kV/µs (line-PG) ≤ 600 V
  • Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019

Applications:

  • For protecting low voltage equipment against lightning and surge damages
  • For installation in conformity with the lightning protection zones concept at LPZ 0-1
  • Designed according to IEC 61643-11:2011

 

Specifications:

  • Category IEC / EN / VDE: class II+III / type 2+3 / C+D
  • Max. continuous operating voltage Uc 275 V AC
  • Nom. discharge current (8/20 μs) In 10 kA
  • Max. discharge current (8/20 μs) Imax 20 kA
  • Voltage protection level Up ≤ 1,5 kV
  • Max. backup fuse 125 A

Phase voltage controller PKF-302. The device is designed for electric motor protection from asymmetric supply and grid voltage drop. The controller has two switch outputs of which one is used for protective shutdown and another for alarm. Simplified type 333 variant.

  • Channels: Shutdown and alarm
  • Supply: 3x (50...230...265)V. Max 2,5W
  • Frequency: 40...50...60 Hz
  • Indicator: 3 x LED 3 digits
  • Measuring mode: True RMS
  • Activation voltage: 185 V
  • Reset voltage: 195 V
  • Activation time: about 1s
  • Reset time: 1...999 s (optional 4 or 6 s)
  • Switch outputs: 2 x switching 2A, 250V AC
  • Ambient temperature: -15°C...55°C
  • Mounting: 35 mm rail
  • Protection class: panel IP40; connections IP20

Phase voltage controller PKF-333SZE. The device is designed for electric motor protection from asymmetric supply and grid voltage drop or overvoltage and automatic UPS activation. The controller monitors voltage phase angles and harmonic distortions due to generated high harmonics.

Phase voltage controller PKF-333SZR. The device is designed for electric motor protection from asymmetric supply and grid voltage drop or overvoltage and automatic UPS activation. The controller monitors voltage phase angles and harmonic distortions due to generated high harmonics.

  • Measures and records parameters in 3 and 4-wire, 3-phase, balanced or unbalanced power network
  • Up to 500 electrical network quality parameters according to EN 50160, EN 61000-4-30, standards
  • Measuring class A or A / S
  • Support the IEC 60870-5-104 communication protocol (new - option)
  • Analysis of voltage and current harmonics and interharmonics (up to the 51-st)
  • Monitoring up to 6 additional energy meters with pulse output
  • Recording of measurements before and after events (dips & swells)
  • Configurable archives of logged values and events
  • SD card support (up to 32 GB)
  • Webserver function, FTP server, DHCP client
  • Outputs: relays, binary, analog
  • Binary inputs
  • E-mail alarms
  • Interfaces: RS-485 Modbus slave, Ethernet 100 Base-T (Modbus TCP server), USB device and host
  • Color touchscreen: LCD TFT 5.6“
  • Many data representation modes (i.e. digital display, analog, bar graph, vector diagram)
  • IP65 protection class for front side
  • Real time clock (RTC) synchronization with NPT time server
  • Time synchronization via external GPS module - STR  receiver (new - option)

Measurement of 54 power network parameters, including current and voltage harmonics up to 63rd in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems

  • High accuracy class (0.2S for active energy)
  • Interface: RS-485 (Modbus RTU 8N2,8E1,8O1,8N1)
  • Graphical color display: LCD TFT 3,5’’, 320 x 240 pixels, fully configurable by a user (10 screens, 8 parameters in each)
  • Additional 2 screens for harmonics presentation and 1 dedicated screen for visualization in the form of an analog meter
  • Memory of minimum and maximum values
  • 2 configurable alarm outputs
  • Supervisory relay mode for alarm outputs
  • Password protection
  • Programming of parameters using free eCon software
  • Battery backup RTC
  • Supply: 85...253 V ac / 90...300 V dc
  • Operating temperature: -10…23…+55 °C
  • Overall dimensions: 96 x 96 x 77 mm
  • Pressure range: from 0...2,5 to 0...700 bar
  • Process temperature: -40...+125 °C
  • Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
  • Protection class: IP65, IP67
  • 2 analog outputs (operating simultaneously):
    1. Current 4...20 mA or 0...20 mA (active output, cannot be supplied in two-wire current loop);
    2. Voltage 0...10 V.
  • Soft start/stop (ramping) or a triangular wave generator triggered manually or automatically after switching power on
  • 7-segment LED display with adjustable brightness
  • Optional RS485/RS232 serial interface (galvanically isolated, MODBUS-RTU communication protocol)
  • Password protection
  • High accuracy and immunity to interference
  • Supply: 230 VAC or 24 VAC/VDC
  • Panel housing 96 x 48 x 79 mm
  • Protection: IP65 (front) / IP20 (back)

Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. For direct (up to 63A) and indirect measurement (x/1A or x/5A). Indications considering values of programmed ratios.

  • Ethernet connection
  • Digital inputs: 2
  • 1-Wire input (up to 2 sensors)
  • Analog inputs: 2 (0...60 VDC)
  • Relay outputs: 2 (NO/NC)
  • Webserver
  • HTTP and XML API commands
  • E-mail alarms, SMTP, SNMP
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...14 VDC
  • Signal splitter DAT5022
  • Configurable with switches on body
  • 3-way galvanic isolation (2000 VAC)
  • Input: 4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V
  • Output: 2 X (4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V)
  • Power Supply: 18...32 VDC. Reverse polarity protection 60 VDC
  • Current Consumption: Current output 35 mA max. Voltage output 25 mA max.
  • Environment: -20...+70 °C / (non-condensing) 0-90%
  • Housing: Self-extinguishing material
  • EMC
    • Immunity: EN 61000-6-2
    • Emission: EN 61000-6-4

They are used to regulate the power delivered to the receiver, where this power is proportional to the input control signal. They are used in automation control systems where smooth control of receiver power is required for resistive or resistive-inductive loads. Typical applications for power controllers: heaters, industrial furnaces (annealing, quenching, drying, etc.), dryers, plastics processing equipment, industrial sealing machines, glass production industry, industrial heating systems (matting and lining of pipelines), load transformers.

  • Single-phase power controller (phase angle load control)
  • Control input: DC voltage 0...10 V DC (RSR92-..V..) or current 4...20 mA (RSR92-..I..)
  • SCR output (thyristors)
  • Load current 25...80 A
  • Max. load voltage 280, 530 V AC (single-phase)
  • Dielectric strength 4 000 Vrms (opto-isolation)
  • MOV protection (built-in varistor)
  • Mounting on panel or on heatsinks
  • Recognitions, certifications, directives: RoHS, REACH, CE, EAC

RSP-E25-... is a Class I+II SPD for surge and lightning protection of low-voltage power supply systems, especially in high-risk exposure areas or building entrances in LPZ 0-2 (IEC 62305-4), protecting against damage caused by direct or nearby lightning strikes; suitable for use in main distribution boards.

  • IEC / EN / VDE category: Class I+II / Type 1+2 / B+C
  • Application: main distribution boards (MB)
  • Power networks: TT, TN-S, TN-C
  • Protection modes: L-N, N-PE
  • Protective elements: MOV, MOV+GDT
  • Enclosure: modular (replaceable module)
  • Mechanical status indicator: green/red flag
  • Compliant with standards: IEC/EN 61643-11:2011, IEC 60364-4-53, IEC 62305, CE, RoHS
  • Destined to synchronize generator, wind, water turbine and similar devices connecting to the network
  • Eliminate voltage difference, frequency, and phase shift angle
  • Ethernet interface 10/100 base-t, RS-485 interface with Modbus RTU protocol
  • Web server, Modbus TCP / IP, DHCP server
  • Protection class from frontal side: IP65, terminal side: IP20
  • Electrical safety CAT III measurement category
  • Voltage range (resolution): 20...180 V (0,1 V), 60...480 V (0,1 V), ...1920 kV (0,01 kV)
  • Voltage difference (resolution): -20...0…20 % (0,1 %)
  • Frequency range (resolution): 45...65 Hz (0,001 Hz)
  • Frequency difference (resolution): -10...0...10 % (0,01 %)
  • Phase shift (resolution): 0...360 o (0,1 o)
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures carbon dioxide (CO2) using the integrated sensor.
  • Measures barometric pressure using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.

They are used to regulate the power delivered to the receiver, where this power is proportional to the input control signal. They are used in automation control systems where smooth control of receiver power is required for resistive or resistive-inductive loads. Typical applications for power controllers: heaters, industrial furnaces (annealing, quenching, drying, etc.), dryers, plastics processing equipment, industrial sealing machines, glass production industry, industrial heating systems (matting and lining of pipelines), load transformers.

  • Three-phase power controller (phase angle load control)
  • Control input: DC voltage 0...10 V DC or current 4...20 mA
  • SCR output (thyristors)
  • Load current 25...80 A
  • Max. load voltage 530 V AC (three-phase)
  • Dielectric strength 4 000 Vrms (opto-isolation)
  • MOV protection (built-in varistor)
  • Mounting on heatsinks
  • Recognitions, certifications, directives: RoHS, REACH, CE, EAC
  • Transducer for DC current and voltage into other DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • Solves grounding problem in meshed signal networks
  • User selectable type and range of input
  • EDP2041 is standard signals generator (digital potentiometer) with outputs:
    • 0…10 V; Resolution: 1 mV; Fluctuation: max 30 mA; Rise time from 0 to 10V is max. 300ms
    • 0 / 4…20 mA; Accuracy: 0.1 %; Resolution: 2 µA; Fluctuation: max. 60 µA
  • Preset value can be adjusted from external buttons
  • Communication via RS-485 Modbus protocol or synchronous running between two or more potentiometers
  • Display scale can be adjusted between -1999 and 9999
  • Soft on and soft off properties can be selected
  • 4 digits display
  • Parameter access protection on 3 levels
  • Supply: 230 V AC; 24 V AC; 9…30 V DC
  • Ambient temperature: 0…50 °C

The LP10-V monitors the AC voltage of the system / equipment and protects it against overvoltage, undervoltage and phase failure problems. It also indicates faults with LED indicators.

Applications: Motor protection, Server rooms, Control system

Features:

  • Compact size 17.5 mm
  • True RMS measurement
  • Under voltage protection
  • Over voltage protection
  • Phase unbalance protection
  • Phase failure protection
  • Phase incorrect sequence protection
  • Neutral failure protection
  • Adjustable Nominal voltage, Trip point, Trip time delay
  • Onsite selection of VLL / VLN value-based tripping
  • Self-powered
  • 1CO, 1CO+1CO relay configuration
  • LED indication for faults
  • Disabling of Over & Under Voltage fault on site is possible
  • Universal datalogger with 4 inputs for voltage, current, logic and pulse signals.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Open collector transistor alarm output.

Designed for precisely measuring electricity usage and frequency of use. Pulse counter belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • Compliance with MID certificate
  • Maximum current: 40 A
  • Nominal voltage: 230 V, 50 Hz
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply (pulse counter): 1 x AA battery
  • Battery lifetime (20 °C): up to 10 years
  • Protection class sensor / meter: IP67 / IP40

Designed for precisely measuring electricity usage and frequency of use. Pulse counter belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • Compliance with MID certificate
  • Maximum current: 80 A
  • Nominal voltage: 3 x 230 / 400 V, 50 / 60 Hz
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply (pulse counter): 1 x AA battery
  • Battery lifetime (20 °C): up to 10 years
  • Protection class sensor / meter: IP67 / IP40
Wireless voltage sensor 0-10V with PSU, TDSVT102, TDSVT202 Hовый

Measures analog signal of a 3rd party sensor. Provides 24 or 12 VDC power for a 3rd party sensor using the built-in power supply unit (PSU).

  • Sensor compatible with base stations: PRO, PRO Plus ir PRO Plus LTE
  • Voltage measurement range: -32...32 VDC
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Operating temperature: -30...+80 °C
  • Power supply: 85…265 VAC
    • 1 x AA battery is for to notify user in case of external
  • Protection class: IP67
  • Panel electromagnetic devices are designed to measure effective values of current and voltage
  • The devices are fit to be mounted in up to 15 mm-thick panels
  • Meter EB16 is mounted on 35 mm rail
  • Tropical version is also available
  • Ammeters for use with transformers (X/1A and X/5A) available
  • Panel devices are designed to measure AC and DC current and voltage
  • Those with P index have integrated rectifier which enables the device to measure effective currents and voltages
  • Asymmetric form signal measurement accuracy depends on harmonic component levels
  • The devices are fit to be mounted in up to 15 mm-thick panels
  • Meter MB16 is mounted on 35 mm rail
  • Tropical version is also available
  • Ammeters for use with transformers (X/1A and X/5A) available
Loading...