  • Modern SCADA system
  • Free license allows to work with up to 50 objects (each having 10 variables / tags / atoms)
  • Free license supports only one chosen driver (i.e. Modbus)
  • Hardware-independent, communicates with all major industry-standard
  • Mobile application (in full version)
  • 25 year experience in the marketplace  - developed by 7-Technologies which belongs to Schneider Electric
  • Software to work with Comet devices Sxxxx, Rxxxx, UxxxxM, Dxxxx and Mxxxx
  • Device settings
  • Data download
  • Analysis of critical situations
  • Presentation of measured data
  • Reports
  • Database import/export
  • Free license

Broadsens edge-computing wireless gateways connect and control multiple wireless low-power sensors such as SVT200-A, SVT300-A, SVT400-A, SVT200-V, SVT300-V and SVT400-V.

BroadVibra software is installed inside the wireless gateway. The software has intuitive interface and can be accessed from all major web browsers remotely. The software is ideal for predictive maintenance and conditional based monitoring.

  • Communication with sensor: 2.4GHz BLE
  • Up to 190 sensors supported
  • Network interface: Ethernet, Wi-Fi 802.11ac wireless
  • Communication protocol: MQTT, TCP/IP, UDP, Modbus TCP & RTU (RS-485), OPC UA
  • Integrated Database: 64 / 128 GB
  • Notifications and alarms sent by email (SMTP)
  • Vibration analysis: Velocity, RMS, True peak, Peak-peak, STD, Crest factor, Kurtosis, trend analysis, FFT analysis, advanced filtering, frequency fine tuning, trigger modes
  • Working environment: -30...+60 °C, 10...90 %RH
  • Additional features: 2nd power connector, 2 x GPIO ports (input or output, see manual)
  • The purpose of the test chamber is to measure the airtightness of doors which are in the frame of chamber at set pressure
  •  Air is driven into the chamber with a ventilator which is controlled by an AC drive
  • The intake flow rate is measured by CS Instruments VA420 flow rate meter (0-480 m3/4)
  • The pressure in chamber is measured with DPT series differential pressure transmitter
  • The temperature in chamber is measured in 11 points
  • All data is logged and visualized in logger and computer (via IGSS software)
  • The program is designed to represent and log measured values
  • Representation tools: bar graphs, graphs, numbers
  • Interfaces: RS-485 MODBUS RTU, ASCII, LUMBUS, MODBUS TCP/IP
  • Number of MODBUS devices that can be represented (1 device – 1 address): 5, 10, 30 and 100 (selected while ordering)
  • Data logging: tables and/or graphs in PC memory
  • The system is designed to monitor pressure and flow rate of medical gasses
  • Information is gathered from pressure and flow rate transmitters and conveyed into the controllers which transfer the data into a PC via RS-485 interface (MODBUS protocol)
  • SCADA software enables the visualization of the process
  • Data is logged annd represented on the computer screen
  • Values can also be represented in graphs
  • The system is designed to contol ambient parameters (temprature, humidity,lighting time, CO2, O3 and O2 concentration)
  • The data is gathered from various measuring devices and conveyed into a PLC
  • PLC and SCADA interface is MODBUS TCP
  • Manual and automatic control is available
  • Marameters can be changed via SCADA (IGSS) software
  • All data is logged