  • Input: 2x thermocouples - J, K, T, N, E, B, R, and S
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…30 Vdc
  • Warranty: 3 years
  • Portable, small dimension temperature meter with a probe
  • The probe can be 1,5 m, 3 m or of specified length
  • Temperature measurement accuracy: ±1 °C
  • Temperature measurement range: -50...+150 °C
  • LCD screen
  • 2 year warranty
  • Supply: 1x6LF-22 (9 V)
  • Designed to be weld-in into pipelines and boilers
  • Instrument standard threads (F): G1/2", G1/4"
  • Dimensions according to customer's needs
  • Case production: solid or welded
  • Available materials: 1.4301 (AISI304), 1.4401 (AISI316), 1.4404 (AISI316L)
  • Dimension tolerances according to DIN ISO 2768
  • Available other materials, threads, flanges and dimensions
  • Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
  • Standard instrument threads (F): G1/2", G1/4"
  • Dimensions according to customer's needs
  • Case production: welded or solid (flange welded)
  • Available materials: 1.4301(AISI304), 1.4401 (AISI316), 1.4404 (AISI316L)
  • Dimension tolerances according to DIN ISO 2768
  • Available other materials, threads, flanges and dimensions

Solid drilled threaded thermowells, protective cases:

  • Protect and extend the lifetime of temperature sensors and thermometers in processing applications
  • Facilitate the replacement of sensors
  • Allow sensor maintenance without process interruption

Thermowells protect and extend the lifetime of temperature sensors and thermometers in processing applications where the sensors are not mechanically or chemically compatible with the process environment. Moreover, thermowells facilitate the replacement of sensors and allow sensor maintenance without process interruption.

The VA702 is a Volt/mA/TC Calibrator, designed as a source and measurement tool. It measures or outputs a 0 to 24 mA DC current loop, 0 to 20 V DC voltage, and supports thermocouple temperature measurements (model dependent). Note: The calibrator cannot measure and source simultaneously.

  • Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
  • Storage temperature: -40℃ to 60℃
  • Operating temperature: -10℃ to 50℃
  • Operating altitude: Up to 2000 meters
  • Temperature coefficient: ±0.01% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
  • Relative humidity:
    • 95% up to 30℃
    • 75% up to 40℃
    • 45% up to 50℃
    • 35% up to 55℃
  • Power requirements: 6 x AAA batteries
  • Size: 204mm (L) x 99mm (W) x 46mm (H)
  • Weight: 460g (including battery)

The VA710 Thermocouple Calibrator is a high-accuracy handheld instrument for calibrating thermocouple instruments. It measures or simulates 8 types of thermocouples (°C or °F) and millivolts. It cannot measure and source simultaneously.

  • Measure or simulate: Millivolt and 8 types of thermocouples (°C or °F)
  • Display: Large 5-digit LCD with full-angle visibility
  • Accuracy: Max. up to 0.3℃ and 0.025% for mV
  • Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
  • Temperature coefficient: ±0.02%/℃ (from 0℃ to 18℃ and 28℃ to 50℃)
  • Storage temperature: -40℃ to 60℃
  • Operating temperature: 0℃ to 50℃
  • Operating altitude: Up to 3000 meters
  • Relative humidity:
    • 95% up to 30℃
    • 75% up to 40℃
    • 45% up to 50℃
  • Shock: Random 2g, 5Hz to 500Hz
  • Safety: 1 meter drop test
  • Fuse: F 0.125A/250V
  • Power supply: 6 x AAA 1.5V batteries or Standard jack for external power supply
  • Size: 205mm (L) x 98mm (W) x 46mm (H)
  • Weight: 472g (including battery)
  • Measures carbon dioxide concentration in air, temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: 0...2000 ppm, -30...+80 °C, 5...95 %RH
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s; CO2: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures carbon dioxide concentration in air, temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: 0...10000 ppm, -30...+105 °C, 5...95 %RH
  • Temperature and humidity sensor cable length: 1 / 2 / 4 m
  • Carbon dioxide concentration sensor cable length: 1  2 / 5 / 10 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s; CO2: 15 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included

Gas cylinder heating jacket prevents frosting and ensures a constant flow rate for laboratory and industrial processes. Equipped with a digital thermostat, it is suitable for various gases and has a durable, lightweight design with quick-release buckles for easy attachment and transport.

  • Digital thermostat with a heating range from 0 – 90ºC
  • Durable, lightweight design with quick-release buckles
  • Suitable for various gases, including SF6, Propane, Nitrogen, Oxygen, BCl3, WF6, and HF
  • Silicone impregnated fabric
  • Fiberglass insulation
  • Teflon heating wire
  • 3 meter power cable (no plug)
  • Safety Thermostat
  • IP40 Protection
  • Air flow monitor with switching output for control cabinet installation
  • Safely and reliably monitor hot air flows up to 400°C
  • Sensitive response behaviour
  • Large measuring range (0.1...30 m/s), simple and fast commissioning
  • Areas of application: Monitoring of heating coils, drying plants, industrial ovens, granulate dryers, surface technology plants, thermoprocess technology
  • Exd fire-resistant thermocouple temperature sensors are designed for temperature sensing in explosive atmospheres.
  • Ranges: -40...+800°C; -40...+1200°C; -40...+700°C
  • Outputs: TC, 4...20 mA
Multipoint thermocouple temperature sensor TTP-328 is designed for temperature measurement. Suitable for energetics, oil and chemistry industries Every sensor is made out of mineral-insulted cable Process connection is threaded or flanged Compact design Maximum immersion depth is 30 m ATEX design Various variants are possible, depending on client’s request Every sensor can be mounted by up to 24 temperature transmitters. In order to bring the start-up cost down, sensor can be configured by our company. More on TTP-328 multipoint thermocou..
  • Modbus Slave over RS-485
  • Modbus RTU / Modbus ASCII protocols
  • Communication parameters configurable by dip-switches
  • Watch-dog alarm
  • Remotely configurable
  • 3-way galvanic isolation (1500 VAC)
  • High accuracy
  • Mounting on DIN rail - EN-50022 compliance
  • Ethernet 10/100 Base-T interface
  • Modbus TCP server
  • Webserver for configuration of device and representation of actual input values
  • Galvanic isolation on all the ways (1500 VAC)
  • Remotely configured
  • LED indication
  • EMC compliance
  • DIN rail mounting
  • Measures ambient temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measuring ranges: -30...+80 °C, 0...100 %RH
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures ambient temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measuring ranges: -30...+105 °C, 0...100 %RH
  • External sensor cable length: 1 / 2 / 4 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30 for device, IP40 for sensor
  • Calibration certificate included
  • Inputs: 4x external sensors + 1x internal temperature sensor
  • 3x Thermocouple type B, J, N, S, T external temperature sensor
    • Measuring range: according to the connected thermocouple
    • Accuracy: ± 0,4 °C
    • Resolution: 0,1 °C
  • 1x PT1000 external temperature sensor
    • Measurement range: -200...+260 °C
    • Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
    • Resolution: 0,1°C
  • Internal temperature sensor
    • Measuring range: -30…+70 °C
    • Accuracy: ± 0,4 °C
    • Resolution: 0,1 °C
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: adjustable 1 s...24 h
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+70 °C
  • Supply: lithium ion 3,6 V AA battery
  • Protection class: IP20
  • Warranty: 3 years
  • Sensor for remote temperature monitoring over the Internet (Ethernet interface)
  • Webserver function
  • Ideal for server, air conditioning, HVAC, warehouse, museum and factory temperature monitoring
  • Remote alarm (meter sends an e-mail when the set temperature range is breached)
  • Archive in CSV format
  • MODBUS TCP protocol
  • Calibration certificate included
  • 3 year warranty

The TJ-S temperature sensor is permanently connected to a cable and designed for measuring temperatures from -50°C to 400°C.

Various cable lengths are available.

  • Sensor type: PT100, PT1000, NTC, Thermocouples K, J
  • Measuring range: -50…+400 °C
  • Operating temperature:
    • -30...+70 °C (PVC isolation)
    • -50...+180 °C (Silicone isolation)
    • -50...+400 °C, kabelio -50...+250 °C (Teflon isolation)
    • -50...+400 °C, kabelio -50...+400 °C (Fiberglass isolation)
  • Cable and connection: 2, 3, 4 wire
  • Sensor tube:
    • Material: Stainless steel 316 (1.4401)
    • Diameter: Ø4 mm
    • Length: 120 mm
  • Temperature range: from +20...+110 °C iki +40...+300 °C
  • Output signal: 1 floating change-over contact
  • Process temperature: +20...+300 °C
  • Approval: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, RMRS, EN60730-1/ EN60730-2-9: Typ 2.B.H
  • Protection class: IP65
  • Operates as a temperature switch (thermostat), transducer, data logger
  • Accumulated temperature data is read using a mobile phone with NFC interface
  • Parametrization via NFC interface
  • Display and electrical connection are independently rotatable 335°/343°
  • Temperature measurement range: -50...+150 °C
  • Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
  • Switch output: 2 x PNP
  • Sensor: Pt1000 A
  • Data logger memory: 3518 measurement points
  • Measurement interval: 0,1...999,9 s
  • Operating temperature: -25...+85 °C
  • Supply: 15...30 VDC
  • Input (configurable): TC, RTD, mV, resistance and potentiometer
  • Output: Modbus RTU / ASCII Slave device over RS-485
  • 1500 Vac 3-ways Galvanic Isolation
  • High accuracy
  • Remotely configurable over RS-485
  • EMC compliance (CE mark)
  • Mounting in B-type head
  • Easy implementation in existing PLCs and SCADA systems
  • Operating temperature: -40...+85°C
  • Supply voltage: 18...30 VDC
  • Measures ambient temperature, humidity, pressure
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measuring ranges: -30...+80 °C, 0...100 %RH, 600...1100 hPa
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Protection class: IP30

The sensor consists of a replaceable insert, a ceramic protective tube (thermowell) and an aluminium connection head (depends on model) where a programmable temperature transmitter with 4-20 mA output can be installed.

  • Temperature measuring range: 0… +1800 °C
  • Usable areas: Blast furnaces, regenerating air heaters, industrial heating installations, heat generation
  • Standard protection tube material: mullite C610 (Al2O3 60%), Ceramic C799 (99.7% Al2O3)
  • Gastight process connection: (to 0.1 MPa / 1 bar)
  • Optionally the head can be installed with a local temperature display (DANWdie-LED)
  • ATEX and EAC Ex versions
  • For specific model design please look picture below ↓: TT438, TT440, TT441, TT442, TT443, TT444
Thermocouples TTP-320, TTP-321, TTP-322 are suitable for temperature measurement of industrial furnace pipes. Suitable for energetics industry Suitable for oil and chemistry industries Made out of mineral-insulated cable Good vibration resistance Spiral windings for vibration protection Two possible variants, chosen according to client’s request ATEX design Thermocouple TTP-320...TTP-322 description [EN]More on TTP-320...TTP-322 thermocouples on Termoaparatura Wroclaw website [EN] ..

Capillary thermometer TXC is designed for temperature measurement from -200 to +800 °C. Capillary parameters, diameter and length of measuring element, measurement dial range, process connection, contact type and other parameters must be chosen from the catalogue. 

Stainless steel thermometer TXR is designed for temperature measurement from -200 to +800 °C. Diameter and length of measuring element, measurement dial range, process connection, contact type and other parameters must be chosen from the catalogue. 

  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Versions according to PN-79/M-53857/05
  • Threads for thermometer: metric M12x1.5, M14x1.5
  • Lengths: according to customer's specification
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Bore diameters: Ø3.5 mm, Ø7 mm
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Optional designs per DIN 43772 ( form 4 )
  • Other materials, threads and dimensions
  • Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT or other
  • Immersion lengths: from 50 mm to 2500 mm (according to customer's specification)
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti )
  • Dimension tolerance according to DIN ISO 2768
  • Protection tube coated by layer of CrC to increase abrasion resistance
  • Protection tube coated by teflon® PTFE to increase corrosion resistance
  • Other materials, threads, flanges and dimensions
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
  • Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
  • Lengths: according to customer's specification
  • Dimension tolerances according to DIN ISO 2768
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Versions according to DIN 43772
  • Other materials, threads and dimensions
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
  • Lengths: according to customer's specification
  • Dimension tolerances according to DIN ISO 2768
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Versions according to DIN 43772
  • Other materials, threads and dimensions
  • Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
  • Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
  • Lengths: according to customer's specification
  • Dimension tolerances according to DIN ISO 2768
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Versions according to DIN 43772
  • Other materials, threads and dimensions
  • RTKSA series thermostat have cooling or / and heating functions
  • Temperature control range: -10, 0, 20, 30, …50, 110, 120, 150 °C
  • Two-way switching contact
  • Number of outputs: up to 4
  • Number of control ranges: up to 2
  • Sensor element: capillary tube
  • Capillary tube length: up to 12 m
  • Maximum switching voltage: 230 V AC 50 / 60 Hz, 230 V DC
  • Maximum switching current: NC: 16 (2.5) A; NO: 6.3 (2.5) A, 0,25 ADC
  • Minimum switching voltage: 24 V AC / 50 Hz, 24 V DC
  • Universal mounting
  • Ambient temperature for head: up to 80 °C
  • Protection class: up to IP65
  • Safety and EMC: in accordance DIN EN 60730

Sensor SKU: 5905309602588 (IP30)

Sensor SKU: 5905309602595 (IP67)

Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.

  • Supported thermocouple types: B, E, J, K, N, R, S, T
    • Accuracy: depends on the connected thermocouple type
    • Resolution: 0.1°C
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh, 3xAA battery (replaceable)
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -15…+70 °C / 0…99 %
  • Case IP30 protection (IP 67 on request)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third-party systems.

  • Supported thermocouple types: B, E, J, K, N, R, S, T
    • Accuracy: depends on the connected thermocouple type
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 5 seconds to 18 hours (configurable by the user)
  • Measurement sending interval: 1 minute to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -15…+70 °C / 0…99 %
  • Case IP30 protection
  • Measurement range: 32…43 °C
  • Measurement accuracy: ± 0,3 °C
  • Measurement distance: 0…5 cm
  • Measurement duration: 1 s
  • Measurement location: forehead
  • Automatic shut-down: 30 s
  • Measurements: 149 x 38 x 42 mm
  • Operating temperature: 10…40 °C
  • Operating humidity: ≤ 85 %
  • Certificates: ISO13485, CE, CFDA
  • Supply: 2 x AAA batteries
  • Measurement range of external sensor: -200...+600 °C
  • Operating temperature: -30...+80 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Communication protocol: WWW, ModbusTCP, SNMPv1, SOAP, XML
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: piston
  • Measured pressure from  -0,6...3,4 to 4...40 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: -25...+125 °C / -40...+125 °C
  • Ambient temperature: -25...+125 °C / -40...+125 °C
  • Protection: IP65
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H
  • Compact thermostat for shipbuilding
  • ISP version – with capillary tube, ISPT version – without capillary tube
  • Measured temperature from +5...95 °C to +20...150 °C
  • Switching differential: not adjustable
  • Output signal: floating change-over contact
  • Ambient temperature: -30...+70 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Versions according to DIN 43763 and DIN 43772 (form 4)
  • Lengths: according to customer's specification
  • Bore diameters: Ø3.5 mm, Ø7 mm
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Threads for thermometer: metric M14x1.5, M18x1.5
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Other materials, threads and dimensions
  • Measurement range: -40…+180 °C
  • Type: J / K / N / T / E
  • Self-adhesive tape
  • Thermocouple tolerance (accuracy), cable length and insulation can be chosen by demand (see datasheet)
  • Optional: temperature transducer (4...20 mA / 0...10 V / HART / Profibus PA / Fieldbus)
  • Optional: connector
  • TR series indoor thermostat with two temperature settings.TR-04040 (external setting)
  • TR-04040 (external setting): 0...40 °C/0...40 °C
  • TR-04040U (internal setting): 0...40 °C
  • TR-060 (external setting): 0...60 °C
  • TR-060U (internal setting): 0...60 °C
  • Output: Switch
  • Switching voltage / current: 24...250 V, 16 A AC
  • Ambient temperature: -35...65 °C 
  • Protection class: IP65
Temperature relay, mechanical thermostat A/AS/ASE 645/650 for temperature control. Technical specifications Range -45...+15 °C iki 0...60 °C Accuracy  ±2 % Output Switch Switching voltage, current 5...500 VAC, 0,01...20 AAC5...250 VDC, 0,01...20 ADC Ambient temperature -30...50 °C Protection class IP54 Certification EN60730..
Temperature relay, mechanical thermostat M/MS 624/634 with external temperature setting for temperature control. Technical specifications Range -30...+350 °C Accuracy  ±2 % Capillary tube length 2 m Output Switch Setting External Cable Ø 4...9 mm Switching voltage, current 500 VAC 10 (0,75) A30 VDC 6 (1,5) A250 VDC 0..

Temperature relay, mechanical thermostat ATR83 with pipe-mounting for temperature control.

Temperature relay, mechanical thermostat EXAS 409/419 with internal temperature control. Technical specifications Range -30...+60 °C Accuracy  ±2 % Output Switch Switching voltage, current 30 VDC, 5 (5) A 250 VAC, 5 (3) A 250 VDC, 0,25 (0,03) A Protection class IP65 Sensor material Nickel-coated brass Certified for explosive Ex atmosphe..
Loading...