- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø9,8 mm
- Length: 1...35 m
- Tensile strength: ≤ 2,5 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø17 mm
- Length: 1...100 m
- Tensile strength: ≤ 8 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
- Thermocouple commutatotr TK with cold junction compensation for thermocouple measurement output (in turns) to one output
- Connecting that output to measuring device or indicator enables the monitoring of thermocouples in turns
Room thermostat, temperature switch with an electric socket RTBSB-001.401.
- Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
- Measuring principle: piston
- Measured pressure from -0,6...3,4 to 4...40 bar
- Output signal: floating change-over contact (SPDT)
- Switching differential: not adjustable
- Media temperature: -25...+125 °C / -40...+125 °C
- Ambient temperature: -25...+125 °C / -40...+125 °C
- Protection: IP65
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H
- Compact thermostat for shipbuilding
- ISP version – with capillary tube, ISPT version – without capillary tube
- Measured temperature from +5...95 °C to +20...150 °C
- Switching differential: not adjustable
- Output signal: floating change-over contact
- Ambient temperature: -30...+70 °C
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H
- Thermocouple with small measurement tip TJ-K for temperature measurements from -75 °C to +250 °C, fast measurement
- Sensor type: thermocouple K (NiCr-NiAl), class 2
- Measurement range: -75 °C to +250 °C
- Connection: mini connector
- Multipoint float level switches LJ-VDT for fluid level measurement and control
- Multipoint level switch LJ-VDT main difference from LJ-VT is that LJ-VDT uses up to 3 floats instead of one, that ensures control and measuring in more than one level
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Multipoint temperature sensor AUREGIS TJ-D is designed for temperature measurement in different levels of measured environment
- Temperature sensors can be put in one casing or in separate casings
- When they are put in separate casings, measurement points can be spread in various places vertically and horizontally
Multifunctional professional current cramps NC12 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, frequency, temperature (with Pt100 and Pt1000 sensors), electric resistance and capacitance. Twistable clamp direction enables user to measure current in hard-reachable areas. Two variants are available: NC12-300A (up to 300 A AC) and NC12-1000A (up to 1000 A AC).
- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- Pressure measurement range: 600...1100 hPa
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
Data logger (recorder) AR207 is designed for temperature, standard DC voltage and current and pulse signal logging. 16/8 programmable channels. 4 programmable (NO or SSR) outputs for control and alarm. Color LCD TFT screen. Ethernet (web server function). Internal memory card which can be expanded using USB flash drive. Panel mounting. Multi-channel data presentation. Internal real time clock (RTC). Programming and data access protection.
- Universal datalogger with 4 hardware MiniDIN inputs for connecting temperature and humidity probes.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 hardware MiniDIN inputs for thermocouples K, J, S, B, T, N.
- Cold junction compensation (CJC).
- Sensors of physical quantities with bipolar voltage output can also be connected. Two voltage ranges: -18...+18 mV and -60...+140 mV.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Thermocouples are ordered separately.
- Open collector transistor alarm output.
- Universal datalogger with 4 hardware MiniDIN inputs, 2 for thermocouples K, J, S, B, T, N and 2 for connecting temperature and humidity probes.
- Cold junction compensation (CJC).
- Sensors of physical quantities with bipolar voltage output can also be connected. Two voltage ranges: -18...+18 mV and -60...+140 mV.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures barometric pressure using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures carbon dioxide (CO2) using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
- Ambient temperature and humidity transducer with 4...20 mA output
- Stem length 700 mm
- Calculated values: dew point temperature, absolute humidity, specific humidity, mixing ration, specific enthalpy
- Display with two periodically changed shown values (can be switched off)
- Integrated sensors
- Calibration certificate is included
- Programmable output
- Low temperature inertia
- For use in non-aggressive environment
- 3 year warranty
- To measure and data logging: carbon dioxide (0...5000 ppm), temperature (0...50 °C), atmospheric pressure (800...1100 hPa), humidity (0…100 % RH) in air and neutral gases
- Free software for configuration and data visualization
- Bluetooth communication for smartphones and tablets (Android and IOS)
- Safety lock magnetic mounting with inviolability system holder (accessories)
- Compatible with food industry environment
- Up to 4 recordable parameters simultaneously
- Optional calibration certificate
- Deactivation of the control system in the case of excessive temperature, or in the case of sensor error
- Universal input for thermocouples and resistance thermometers
- Relay output for disconnecting the temperature control system
- Supply: 230 VAC
- Operating temperature: 0...50 °C
Cartridge electric heating elements are designed to emit large amount of heat in a small area. The heaters are made from heat-resistant steel or brass, with kanthal wire embedded in ceramics and supplemented with magnesium oxide (MgO).
- Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
Temperature and standard signal transducer P30U.
- Programmable input
- Mathematical functions
- Individual channel characteristic
- 1 or 2 outputs
- Variant with internal transducer 24 VDC power supply
- RS-485 interface
- Adjustable dimension
- Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
- Transducer programming with buttons or via PC (“LPConfig” software)
- Temperature transducer TJ-DIN AV, designed to convert temperature measurement signal into 4...20 mA, 0...10 V
- Mounted on 35 mm DIN rail
- Measures air temperature, humidity
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...+80 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
- Measures air temperature, humidity in ducts
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...105 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- External sensor cable length: 1 / 2 / 4 m
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
- Measures air temperature, humidity in ducts
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...125 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
- Ambient temperature and humidity transducer with 4...20 mA output
- Integrated sensors
- Calibration certificate is included
- Economical
- To measure carbon dioxide and temperature in air and neutral gases ranges 0…5000 ppm, 0...50 °C
- Configuration with keypad or software: measuring ranges, units, outputs settings
- Optional with display or without display
- Galvanic isolation all the ways
- On request range increase up to 0...20 000 ppm
Temperature regulator RE72 for ladder control, designed for temperature stabilization in plastics and food industries.
- Universal measurement input
- Auxiliary measurement input 0/4...20 mA
- Binary input
- Ladder temperature control, 15 programs with 15 intervals
- Soft start
- ON/OFF, PID, PID step-by-step (step valve control) or PID heating – cooling
- 8 alarm types, alarm control
- Timer function
- Front panel protection class IP65
- Backside protection class IP20
Process regulator RE82 is designed for temperature stabilization in plastics and food industry.
Humidity and temperature regulator AR247 is designed for temperature and humidity control. The device is made with either integrated or cable-connected sensor. Protection class is IP65. Optionally can be ordered: RS-232 or RS-485 ports, analog output 0/4...20 mA or 0...10 VDC (for control or signal transmission).
- Temperature regulator for usage with Pt100, Pt1000 or NTC sensors
- PID or ON/OFF control
- Automatic selection of PID parameters
- One relay output and one alarm relay
- Manual control mode
- One binary input
- Operating temperature: 0...50 °C
- Supply: 230 VAC
- Protection class: front IP65, back IP20
Regulator RE55 is designed to control temperature in food and chemistry industry.
Temperature regulator RE71 is designed for fixed range and sensor. Input type is selected while ordering. Control: ON/OFF, PID, PID+Autotuning, Smart PID.
Temperature regulator RE81 for fixed range and sensor, with 2 switch or SSR outputs, designed for control in heating, conditioning systems. Function for 3-position control. Control: ON/OFF, PID, PID+Autotuning, Smart PID and 3-position. Input type selected when ordering.
- Measurement distance: 0,5…2 m
- Accuracy: ± 0,5 °C
- Measurement speed: 0,7…2 m
- Software: DERMALOG Fever Detection (PC required)
- Interface: USB 3.0
- SDK: .Net / C / C++ / (Java coming soon)
- Measurement speed: 0,6 s (up to 700 people per hour)
- Integrated sensors: 5
- IR thermal array, range: 0...100 °C (± 0,3 °C)
- Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
- Relative humidity sensor, range: 0...100 % (± 3 %)
- Vibration sensor (for sabotage detection), range: 0,25...5 G
- Distance sensor, resolution: 1 mm
- Dew point calculation
- Relay inputs: 2
- Relay outputs: 2
- LED indication, buzzer (85 dB)
- Communication: Ethernet (10/100)
- Connector (RJ45) for connection of other Kentix devices
- Webserver
- Software: remote connection with AlarmManager-PRO
- E-mail, SNMP alarms, Rest API
- SD card slot (to save pictures, card up to 128 GB)
- PoE
- Optional: RFID reader
- Optional: wall bracket, cable
- Industrial temperature protectors (temperature switches) TS-M, TS-B, TS-1, TS-4, designed for temperature control
- Temperature switch is designed to control when set temperature is reached
- Depending on type, after cooling about 30±15K from base temperature, the temperature switch returns to initial state
- Wide temperature range: -10...+1200 °C
- 320 x 240 and 640 x 480 infrared resolution
- 9 or 60 Hz models available
- Sighting: IR-Fusion technology (thermal and visible sighting) for easy alignment and added detail on blended images
- Remote motorized focus
- Multiple field interchangeable lens options available
- GigE Vision interface
- LAN/Ethernet with PoE for communication with the thermal imager provides access to Ethernet, Web server and ThermoView Software
- I/O alarming capabilities
- ThermoView software for industrial automation applications
- Ambient temperatures to 200 °C with high temperature enclosure
- Air purge and accessories available
- Rugged housing, IP67 rated
- Measurement range: -40…+180 °C
- Type: J / K / N / T / E
- Self-adhesive tape
- Thermocouple tolerance (accuracy), cable length and insulation can be chosen by demand (see datasheet)
- Optional: temperature transducer (4...20 mA / 0...10 V / HART / Profibus PA / Fieldbus)
- Optional: connector
- Indoor temperature controller of TR series (S+S Regeltechnik, Germany)
- TR-040 (external setting): 0...40 °C
- TR-040U (internal setting): 0...40 °C
- TR-060 (external setting): 0...60 °C
- TR-060U (internal setting): 0...60 °C
- Output: Relay
- Switching capacity: 24...250 VAC (16 A)
- Ambient temperature: -35...65 °C
- Protection class: IP65
- TR series indoor thermostat with two temperature settings.TR-04040 (external setting)
- TR-04040 (external setting): 0...40 °C/0...40 °C
- TR-04040U (internal setting): 0...40 °C
- TR-060 (external setting): 0...60 °C
- TR-060U (internal setting): 0...60 °C
- Output: Switch
- Switching voltage / current: 24...250 V, 16 A AC
- Ambient temperature: -35...65 °C
- Protection class: IP65
Temperature relay, mechanical thermostat ATR83 with pipe-mounting for temperature control.