- Датчик температуры ТJ-S с соединительным кабелем. Предназначен для измерения температуры в диапазоне -50°C до 400°C.
- Возможны исполнения по требованиям заказчика
- Тип сенсора: PT100, PT1000, K, J
- Temperature sensor TJ-S (with cable, angled), designed for temperature measurement from -25 to +180 °C
- Various versions are available we also produce sensors according to client’s requests
- Sensor type: Pt100, Pt1000, K, J, PTC, NTC
- The temperature sensor TJ1-TTP is inextricably connected to the cable, it is designed for measuring the temperature ranging from -30 °C to 400 °C
- Various sizes are available depending on customer requirements and drawings
- Sensor type: termocouple K, J
Devices of SPECTRO-3 series are designed to detect “true-color” (human color reception). Sensors can be used in AC or DC modes, with internal or external light source.
Fluid level electrode probes SKC-201, designed to control conductive fluid level in open and pressure tanks. Electrodes – rod or flexible (rope with plastic coating). Probe head is made of acid-resistant steel. Maximal electrode count – 3. Insulation is made out of high quality plastic, enabling the probe to be used in food industry. Standard version probes are coated with plastic (FEP, PU, PVDF), lowering the residue collection (slime, carbonate, foam, etc.). Two modifications are available – with connection cable (P) and connector (G).
Capacitive level sensor Reka 2000 is designed to be submerged into liquids, made out of non-toxic polypropylene (PP)
Capacitive oil level sensor PWP-420.60, designed for oil, liquid fuel, food oil and other fluid level control in metal and nonmetal tanks. Special sensor versions are suited for work in aggressive fluid mediums (acids, alkalis).
CLM-36 are designed for continuous level measurement of liquids and bulk-solid materials. Mounted directly in containers, tanks, etc. Indicator LDU-410 can be mounted on head. Can be used in high temperature and explosive atmospheres. Current (4...20 mA) or voltage (0...10 V) output.
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø9,8 mm
- Length: 1...35 m
- Tensile strength: ≤ 2,5 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø17 mm
- Length: 1...100 m
- Tensile strength: ≤ 8 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
- Thermocouple commutatotr TK with cold junction compensation for thermocouple measurement output (in turns) to one output
- Connecting that output to measuring device or indicator enables the monitoring of thermocouples in turns
- Thermocouple with small measurement tip TJ-K for temperature measurements from -75 °C to +250 °C, fast measurement
- Sensor type: thermocouple K (NiCr-NiAl), class 2
- Measurement range: -75 °C to +250 °C
- Connection: mini connector
- Multipoint float level switches AUREGIS LJ-VD for fluid level measurement and control
- Multipoint level switch LJ-VD main difference from LJ-V is that LJ-VD uses up to 3 floats instead of one, that ensures control and measuring in more than one level
- Multipoint float level switches LJ-VDT for fluid level measurement and control
- Multipoint level switch LJ-VDT main difference from LJ-VT is that LJ-VDT uses up to 3 floats instead of one, that ensures control and measuring in more than one level
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Multipoint temperature sensor AUREGIS TJ-D is designed for temperature measurement in different levels of measured environment
- Temperature sensors can be put in one casing or in separate casings
- When they are put in separate casings, measurement points can be spread in various places vertically and horizontally
- Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Float level switches AUREGIS LJ-V with an extension for level control
- Operating temperature: -30...+130°C
- Protection class: IP65
- Radar level meter GRLM-70 for continuous level measurement in liquids, mush and bulk-solid materials
- Outputs: 4...20 mA HART or RS-485 Modbus RTU
- Measurement depth: up to 40 m
- Universal usage, direct mounting into containers, silos, vessels, reservoirs, etc.
- LCD or OLED screen
- Linear measurement in non-conductive and in differently shaped containers
- Versions with stainless steel rod or rope electrodes
- Xi, Xit versions for usage in explosive areas
- Xd, XdT versions for usage in flammable dusts areas
- Supply: 18...30/33/36 VDC
- Protection class: IP67
- System consists of alarm device SET-1000 and fixed level vibration sensor SET/V
- For usage separators, basins and tanks
- Alarm device SET-1000 is a single-channel level switch
- When used with SET/V, SET-1000 alarms when set high level in tank is exceeded
- ATEX certified
- Wall-mounted
- Supply: 230 VAC, 50/60 Hz
- Measurement range: -40…+180 °C
- Type: J / K / N / T / E
- Self-adhesive tape
- Thermocouple tolerance (accuracy), cable length and insulation can be chosen by demand (see datasheet)
- Optional: temperature transducer (4...20 mA / 0...10 V / HART / Profibus PA / Fieldbus)
- Optional: connector
Ultrasonic level meter ULM-53 is designed for continuous liquid (even if polluted), mash and paste materials level measurements in closed and open tanks, sumps, open channels, etc. Adjustments are made with two buttons. State indication by two LEDs. Current (4...20 mA, 20...4 mA) or voltage (0...10 V, 10...0 V) outputs. Xi version is for usage in explosive areas.
ULM-70 is designed for continuous non-contact level measurements. Suitable for usage in various liquids and bulk-solid materials. OLED display. Fast measured values representation on display. Current (4...20 mA) output with HART protocol. Xi version for usage in explosive atmosphere.
- Capacitive moisture measurement
- Up to 16 sensors per signal processing unit
- Temperature range of measuring material: 4...80 °C
- Measured value transfer: Profibus DP or analogue standard signal (e.g. 4...20 mA) optional
- Continuous measurement or batch operation
Fluid level electrode probes SKC-101, designed to control conductive fluid level in high temperature and high pressure medium. Modifications differ by permissible operating temperature. Recommended to use with Elcluwo 112...114 level alarms.
- Electrode level sensor AUREGIS LJ-B for level measurement
- Process temperature: From -30 to 180°C
- Electrode level sensor AUREGIS LJ-DSH-2R, LJ-DSH-3R for level measurement
- LJ-DSH-2R - 2 electrode level sensor; LJ-DSH-3R - 3 electrode level sensor
- Process temperature: -20...+80 °C
Electrode level sensor AUREGIS LJ-E3 with 3 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.
Electrode level sensor AUREGIS LJ-E5 with 5 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
- Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
- Double water- and air-resistant sealant increases protection against infiltration even more
- Weight: 1050 g; Buoy volume: 990 cm3; Maximum pressure: < 2 bar
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached.
- Weight: 163 g; Buoy volume: 280 cm3: Maximum pressure:< 1 bar
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
- Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
- Double water- and air-resistant sealant increases protection against infiltration even more
- Weight: 250 g; Buoy volume: 430 cm3; Maximum pressure: < 1 bar
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
- Boasts for great reliability and small size
- Weight: 111 g; Buoy volume: 225 cm3; Maximum pressure: < 2 bar / < 5 bar