This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Поиск

Критерии поиска

Товары, соответствующие критериям поиска

Показать:
Сортировка:
  • SET-1000 + SET/OSK2 is designed for oil detection on water surface
  • Can be used in tanks where water level is alternating
  • Control device SET-1000 is a one-channel level switch
  • SET/OSK2 sensor detects more than 15 mm width hydrocarbon layer on water surface
  • Polypropylene floats
  • ATEX certified
  • Wall-mounted, IP67
  • Supply: 230 VAC, 50/60 Hz
  • Lokaset 20 is designed for high wastewater level detection in septic tanks
  • Easy to install, does not need calibration
  • Switch output
  • Visual and acoustic alarms
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
  • Relay output: 2 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Temperature input: none / Pt100 / Pt1000 / thermocouple
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
  • Relay output: 3 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA (optional: double output)
  • Relay output: 4 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • GA-1 is designed for grease detection in separators, basins and tanks
  • Easy to install, does not need calibration
  • Switch output
  • Remote monitoring capability
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • GA-2 is designed for grease detection in separators, basins and tanks
  • Two sensors – one is for grease detection, other – for blockage control
  • Easy to install, does not need calibration
  • 2 switch outputs
  • Remote monitoring capability
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • High level detection
  • Oil on water surface detection
  • Designed for usage in separators, basins and tanks
  • Easy to install, does not need calibration
  • Reliable long-term se in harshest conditions
  • Acoustic and visual alarms
  • 2 switch outputs
  • ATEX certified
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • Input: standard 4...20 mA signal or capacitive Labkotec 3W probe
  • Current output: 0/4...20 mA
  • Switch outputs: 2 units
  • LCD display
  • Programmable using buttons
  • ATEX certified
  • Wall-mounted, IP65
  • Supply: 230 VAC, 50/60 Hz
  • High level detection
  • Oil on water surface detection
  • Sludge under water detection
  • Designed for usage in separators, basins and tanks
  • Version with GSM module available – for alarms and service reminders
  • Acoustic and visual alarms
  • 2 switch outputs
  • ATEX certified
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • OilSET-1000 is designed for oil detection in separators, basins and tanks
  • Easy to install, does not need calibration
  • 2 switch outputs
  • Ultrasonic sensor SET/S, 5 meter cable
  • ATEX certified
  • Wall-mounted, IP67
  • Supply: 230 VAC, 50/60 Hz

Temperature regulator SCD210 is designed for temperature control in various devices and rooms. Made in three variants with different inputs. SCD210 has a step set point (SP) value change by signal option in binary input.

  • Sludge and sand detection
  • Oil on water surface detection
  • Designed for usage in separators, basins and tanks
  • Easy to install, does not need calibration
  • Reliable long-term se in harshest conditions
  • Acoustic and visual alarms
  • 2 switch outputs
  • ATEX certified
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • SandSet-1000 is designed for sludge and sand detection in separators, basins and tanks
  • Easy to install, does not need calibration
  • Reliable long-term se in harshest conditions
  • Acoustic and visual alarms
  • 2 switch outputs or output to LabkoNet remote monitoring system
  • Ultrasonic sensor SET/S, 5 meter cable
  • ATEX certified
  • Wall-mounted, IP67
  • Supply: 230 VAC, 50/60 Hz

Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.

Data logger (recorder) AR207 is designed for temperature, standard DC voltage and current and pulse signal logging. 16/8 programmable channels. 4 programmable (NO or SSR) outputs for control and alarm. Color LCD TFT screen. Ethernet (web server function). Internal memory card which can be expanded using USB flash drive. Panel mounting. Multi-channel data presentation. Internal real time clock (RTC). Programming and data access protection.

Regulator RE22 is designed to control furnace, dryer, cast machine and other devices’ temperature.

Temperature regulator RE72 for ladder control, designed for temperature stabilization in plastics and food industries.

 

  • Universal measurement input
  • Auxiliary measurement input 0/4...20 mA
  • Binary input
  • Ladder temperature control, 15 programs with 15 intervals
  • Soft start
  • ON/OFF, PID, PID step-by-step (step valve control) or PID heating – cooling
  • 8 alarm types, alarm control
  • Timer function
  • Front panel protection class IP65
  • Backside protection class IP20

Process regulator RE82 is designed for temperature stabilization in plastics and food industry.

Humidity and temperature regulator AR247 is designed for temperature and humidity control. The device is made with either integrated or cable-connected sensor. Protection class is IP65. Optionally can be ordered: RS-232 or RS-485 ports, analog output 0/4...20 mA or 0...10 VDC (for control or signal transmission).

  • Temperature regulator for usage with Pt100, Pt1000 or NTC sensors
  • PID or ON/OFF control
  • Automatic selection of PID parameters
  • One relay output and one alarm relay
  • Manual control mode
  • One binary input
  • Operating temperature: 0...50 °C
  • Supply: 230 VAC
  • Protection class: front IP65, back IP20

Regulator RE55 is designed to control temperature in food and chemistry industry.

Temperature regulator RE71 is designed for fixed range and sensor. Input type is selected while ordering. Control: ON/OFF, PID, PID+Autotuning, Smart PID.

Temperature regulator RE81 for fixed range and sensor, with 2 switch or SSR outputs, designed for control in heating, conditioning systems. Function for 3-position control. Control: ON/OFF, PID, PID+Autotuning, Smart PID and 3-position. Input type selected when ordering.

  • System consists of alarm device SET-1000 and fixed level vibration sensor SET/V
  • For usage separators, basins and tanks
  • Alarm device SET-1000 is a single-channel level switch
  • When used with SET/V, SET-1000 alarms when set high level in tank is exceeded
  • ATEX certified
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz

General purpose regulator AR630 is designed for usage in humid or dusty environment (IP65). RS-232, RS-485 or analog ports are optional. Two programmable inputs (for temperature sensors and DC). Settings are protected by password. Set point blocking. Manual output control. Modification AR632 has two indicators (for set point (SP) and process value (PV)).

General purpose regulator with one programmable input and 2 or 3 outputs. Variant with RS-485 is used for work in measuring systems. Programmable binary input for remote work mode modification. PID autotuning. Free software for configuration. Manual control feature.

  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
  • Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
  • Double water- and air-resistant sealant increases protection against infiltration even more
  • Weight: 1050 g; Buoy volume: 990 cm3; Maximum pressure: < 2 bar
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached.
  • Weight: 163 g; Buoy volume: 280 cm3: Maximum pressure:< 1 bar
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
  • Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
  • Double water- and air-resistant sealant increases protection against infiltration even more
  • Weight: 250 g; Buoy volume: 430 cm3; Maximum pressure: < 1 bar
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
  • Boasts for great reliability and small size
  • Weight: 111 g; Buoy volume: 225 cm3; Maximum pressure: < 2 bar / < 5 bar