- Digital pulse counter - tachometer ECH4400
- Count inputs: 2 channels (max 50 kHz, 5…30 V pulses), can be selected as PNP or NPN input
- Counting frequency: (20, 50, 100, 500, 1000, 5000) Hz, (10, 20, 30, 40) kHz
- Control outputs: 2 relay NO / NC 250 V, 2 A
- SSR outputs: Open collector output (Max.: 30 VDC, 50 mA)
- RS485 Modbus communication interface (custom ordered)
- Power supply: 90…250 V AC; 10…30 V DC; 8…24 V AC (custom ordered)
- Auxiliary supply output: 12 VDC, max 50 mA
- Ambient temperature: 0…+50 °C
- Case protection: front panel IP65, rear panel IP20
Utilizing unique dual-sensing technology, the device combines electromagnetic induction with an integrated ultrasonic sensor to provide highly accurate detection of both liquid level and flow velocity. Specifically optimized for partially filled pipes, open channels, and gravity-fed systems, the unit achieves an outstanding accuracy of ±1–2% of the actual flow rate.
- Internal pipe diameter: DN80…DN600
- Flow velocity (min. / max.): 0,46…7,5 m/s
- Accuracy: ± 1…2 % of actual flow (depends on flow profile and level detection)
- Process Temperature: 0…+70 °C
- Coating materials: hard rubber
- Maximum working pressure: No pressure (gravity flow) or 10 bar if pipe is full
- Output signal: 2× pulse / flow switch (max. 400 Hz), 4 ... 20 mA, 1× RS485 interface (Modbus / M-Bus protocol), M-Bus, HART, Ethernet module (TCP/IP, integrated web server)
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Data archiving on a micro-SD card
- Process connections: flange
- Maximum ambient temperature: 55 °C
- Power supply: 24 V AC / DC, 230 V AC
- Protection class: IP68 for sensor, IP65-IP68 for transmitter
The enLink Status-P transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- 3 channels pulse counter (S0 standard) and monitor of state (open / closed)
- With the transmit on Change of State enabled the unit operates as a standard pulse counter and also transmits a message when the state of the input changes from closed to open or open to closed
- The pulse counts for each channel are written to memory every 5 – 10 minutes
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours or adaptive (triggered by change of state)
- 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
- Configuration via USB cable / downlink
- Case IP40 protection (IP 67 on request)
- 10 time functions. With control signal and without additional signal
- 10 time ranges. Ranging from 0,1 sec. to 30 hours
- Operating voltage: 12…240 V AC / DC
- Operating power: < 4 VA
- Mounting on DIN rail
- Operating temperature: -20…+55 °C
- Digital input: 4 ch. pulse
- Independent modes: OPEN / CLOSED (“Dry contact”) and COUNTER (S0 standard)
- Output: RS-485 MODBUS RTU interface
- Non-volatile memory for counters storage and settings
- Galvanically isolated inputs
- DIN rail mounting
- Protection class: IP40 (connections IP20)
- Operating temperature range: -20…+60 °C
- Power supply: 5…28 VDC
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures carbon dioxide (CO2) using the integrated sensor.
- Measures barometric pressure using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs for voltage, current, logic and pulse signals.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Open collector transistor alarm output.
Designed to monitor electrical, gas, and water meters, as well as other measurement devices that have a dry contact pulse output feature. This device, belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.
- Maximum pulse frequency: 25 Hz
- Minimum pulse width: 10 ms
- Minimum interval between pulses: 30 ms
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Data encryption
- Supply: 1 x AA battery
- Battery lifetime (20 °C): up to 10 years
- Operating temperature: -40...+60 °C
- Protection class: IP67
LoRa-Log-Meter is a wireless data logging system based on LoRaWAN communication technology. It is designed to collect data from LoRaWAN devices such as sensors, interfaces, and meters that monitor environmental, technological and industrial process parameters and transmit data packets to a LoRaWAN gateway.
Collected data is processed and stored in the gateway, and can be accessed via a web browser.
- Compatible with Synetica and others LoRaWAN devices: analog inputs (4–20 mA, 0–20 mA, 0–10 V), temperature sensors, pulse inputs (SO, NC/NO contacts) and others
- Individual alarm notifications based on specific sensors or contacts
- Alarm notifications via email and SMS
- Logging and review of errors and communication issues
- Remote access to the LoRa-Log-Meter system via 4G LTE, Wi-Fi, or LAN (Ethernet)
- Dynamic data visualization in graph (curve) format via a web browser
- Data export in CSV and PNG formats
- Password-protected user interface
- No subscription required for the gateway or sensors
- Remote configuration of data transmission intervals for devices via a web browser
- Communication range from sensor to gateway:
- 15 km Outdoors (in plain sight)
- 50–200 meters indoors or up to 7–8 walls*
- LoRaWAN devices powered by: 2 × AA 3.6 V lithium batteries or 5 V USB power
- G2-P pulse counter converts wired consumption meter into a wireless meter
- Types of devices: water, electricity, HCA, room sensor devices, etc.
- Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
- Modes: configurable C, T, or S
- AES-128 encryption mode 5, profile A
- Value format: 0,001...10000 / pulse (configurable). Unconverted dimensionless value
- The total number of pulses is sent periodically
- It is possible to count pulses from two devices simultaneously
- Pulses from the electricity meter LEDs can also be counted using an optical probe (only one optical probe can be mounted)
- Transmission interval: configurable 60 s…1 hour
- Tamper protection
- Operating temperature: -30…+85 °C none condensing (recommended +5…+50 °C)
- Power supply: AA battery 3.6 V Li-SOCI2
- Battery lifetime up to 14 years, depends on configuration and operating temperature
Sensor SKU: 5905309601383 (IP30)
Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.
- 3 channels pulse counter (more / less channels on request)
- Supported counters: NO (Pull-up 3.6V)
- Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
- Possibility to integrate sensor to other third-party systems
- Operating temperature / humidity: -35…+70 °C / 0…99 %
- Case IP30 protection
Sensor SKU: 5906660327721 (IP30)
Sensor SKU: 5905309600676 (IP67)
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud** platform or any other third party systems.
- 3 channels pulse counter (more / less channels on request)
- Supported counters: NO (Pull-up 3.6V)
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 1 minutes to 18 hours (configurable by the user)
- Measurement sending interval: 5 minutes to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Sensor's configuration can be changed remotely from the cloud or with a mobile application over Bluetooth Low Energy
- Operating temperature: -35…+70 °C
- Case IP30 protection (IP67 on request)
Aranet Rain and Precipitation sensor kit is specifically designed for outdoor monitoring of rain and precipitation. This versatile kit finds applications in agriculture for irrigation and soil moisture management, weather stations, water treatment plants, and more.
- The rain gauge is made of ASA (Acrylonitrile Styrene Acrylate) material which is resistant to sunlight (UV), heat and cold
- Protection against birds (spines) and leaves (mesh)
- Measurement accuracy: ± 2%
- Measurements may be given in units of volume such as liters, milliliters, gallons, or expressed in millimeters per square meter
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Supply (impulse counter): 1 x AA battery
- Battery lifetime (20 °C): up to 10 years
- Operating temperature (pulse counter): -40...+60 °C
- The rain gauge operates from +0 °C as it does not have a warming mechanism
- Protection class (pulse counter): IP68
- Included: rain gauge and wireless pulse counter TDSPIC02.010
- Digital, programmable pulse, frequency, motor revolutions, work time meter N30O with RS-485 interface
- Programmable with keys or via computer
Data logger (recorder) AR207 is designed for temperature, standard DC voltage and current and pulse signal logging. 16/8 programmable channels. 4 programmable (NO or SSR) outputs for control and alarm. Color LCD TFT screen. Ethernet (web server function). Internal memory card which can be expanded using USB flash drive. Panel mounting. Multi-channel data presentation. Internal real time clock (RTC). Programming and data access protection.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures barometric pressure using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures carbon dioxide (CO2) using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
Programmable pulse counter P30O, designed to convert frequency, pulse, input period, time and revolution speed signals into standard voltage or current signals. The device is programmed via PC (RS-485 interface) or with buttons.
Main properties:
- 2 universal pulse inputs
- Mathematical functions for every input
- Individual output characteristic (up to 21 point)
- Option – internal transducer supply source 24 VDC, 30 mA
- RS-485 interface (protocols Modbus RTU Slave, Modbus TCP Slave)
- Data logging function (internal 4 MB memory or SD/SDHC card (up to 8 GB))