  • Analog gas detector MC for connection to DGC, MSC, WSB or any compatible gas detector
  • Reliable self-monitoring: Integrated watchdog
  • Precise signal: 4–20 mA (2–10 V) output for easy system integration
  • Stable long-life electrochemical gas sensor
  • Range 0....1000 ppm CO
  • Resolution 1 ppm CO
  • Default alarms at 25 ppm / 35 ppm CO
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Stable long-life electrochemical gas sensor
  • Range: standard 0....200 ppm CO, maximal 0...1000 ppm CO
  • Resolution 1 ppm CO
  • Default alarms at 25 ppm / 125 ppm CO
  • Outputs 2 x relays with switch-over contacts
  • Visual and acoustic alarms
  • Long-life electrochemical cell
  • Range 0....1000 ppm CO
  • Resolution 1 ppm CO
  • Outputs 4...20 mA / 0...10 V, RS-485
  • Stable long-life electrochemical gas sensor
  • Range 0....200 ppm CO
  • Resolution 1 ppm CO
  • Outputs 2 x relays with switch-over contacts
  • UART digital interface
  • Visual and acoustic alarms
  • Magnetic key switching
  • Electrochemical gas sensor
  • Range:
  • -- 0…300 ppm CO
  • -- 0...1000 ppm CO
  • Resolution: 1 ppm CO
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Addressable digital gas detection system (Sensor-Board SB) for combustible, toxic and refrigerant gases.
  • Communication: RS-485 interface for stable and secure system networking
  • Precise Detection: High accuracy thanks to digital signal processing
  • Easy maintenance with X-Change: Plug & Play systems for fast, convenient service
  • Robust Design: Reliable with IP65 even under extreme conditions
  • Warning- and Sensor-Board WSB for digital and analog sensor technology for the precise detection of combustible, toxic and refrigerant gases.
  • Versatile alarm function: Alarm and fault relays (30 V)
  • Intelligent interfaces: RS-485 interface with DGC or Modbus protocol
  • Precise signal transmission: 4–20 mA input and output for reliable communication
  • Flexible: Connection of up to 3 sensors (2 digital)
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...300 or 0...1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Gas measuring, monitoring and warning controller (Multi-Sensor-Controller MSC) for reliable detection of combustible, toxic and refrigerant gases
  • Flexible control: 3 relays (SPDT, potential-free, 250 V)
  • Intelligent Communication: RS-485 interface with DGC and Modbus protocol
  • Precise signal transmission: 4–20 mA input and output for seamless system integration, up to 3 sensors including remote
  • Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
  • Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
  • Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
  • Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
  • Electrochemical (CO) and optical NDIR (CO2) gas sensors
  • Range: 0...100 ppm CO, 0...10000 ppm CO2
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Operating temperature: -20...+50 °C
  • Supply: 24 VDC/VAC
  • Protection class: IP65
  • Electrochemical gas sensors
  • Range: 0...100 ppm CO, 0...20 ppm NO2
  • Resolution: 1 ppm CO, 0,1 NO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Operating temperature: -20...+50 °C
  • Supply: 24 VDC/VAC
  • Protection class: IP65
Loading...