  • Input: 2x thermocouples - J, K, T, N, E, B, R, and S
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…30 Vdc
  • Warranty: 3 years
  • 4G LTE supported frequency bands:
    • B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/B19/B20/B25/B26/B28/ B66/B34/B38/B39/B40/B41
  • 3G supported frequency bands:
    • B1/B2/B4/B5/B6/B8/B19
  • 2G supported frequency bands:
    • B2/B3/B5/B8
  • M2M communication protocols: MQTT, HTTP API (XML or JSON)
  • Setup via WEB interface through the USB or remote setup with HTTP API or SMS commands
  • Digital inputs: 2 “dry contacts”
  • 1-Wire input (up to 4 sensors)
  • Analog inputs: 2 (0...60 VDC)
  • Relay outputs: 2 (NO/NC)
  • E-mail alarms (up to 5 recipients), SMTP with TLS support
  • SMS alarms (up to 5 recipients)
  • GSM Geolocation (optional)
  • Firmware update over the air (FOTA)
  • Operating temperature: -20...+55 °C
  • Supply: 10…28 VDC
  • Module is designed to protect battery if it discharges below 10,5 V mark, disconnecting it from load
  • Battery is automatically reconnected to load if its voltage rises
  • Suitable for work with heaters, lighting, travel refrigerators, etc.
  • Operating voltage: 12 V ZBxx, 24 V ZBxx-24V, 48 V ZB-48V
  • Maximal current: 40 A ZB40, 80 A ZB80, 140 A ZB140
  • Operating temperature: -20...50 °C
  • Dimensions: 65 x 89 x 70 mm
  • Input: Modbus RTU – RS-485
  • Output: 4-channel SPST relay contacts
  • Rated relay load: 3 A at 250 Vac; 3 A at 30 Vdc
  • Non-volatile memory to retain and restore relay states following power outages
  • Watchdog functionality for communication loss
  • Operating temperature / humidity: -20…+60 °C / 10…90 % (non-condensing)
  • DIN rail mounting
  • Power supply: 5…28 Vdc
  • Warranty: 3 years
  • 4 analog inputs (standard signals, RTD, thermocouple)
  • RS-485 Modbus output (Slave mode)
  • 2 alarm outputs
  • Galvanic isolation of inputs (2 from other 2)
  • Programmable individual characteristics, mathematical functions
  • Programmable time counters
  • Rail-mounted
  • Designed to replace cable data transmission into aerial
  • Can be used in telemetric and information systems
  • The module setting can be done through USB or one of the RS-485 (master/slave) interface using the available for free eCon program
  • Possibility of connection via internal RS-485 port in order to increase no of analog outputs in network
  • Master Modbus function dedicated to read out data from other RS-485 devices and to scale analog value.
  • Slave Modbus function to set the signal on analog outputs
  • Possibility of configuration through USB without power supply