- 1-Wire protocol ambient light sensor
- Light measurement range: 0...83000 lux
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
Applications:
Surge protection for 2 pair lines or 4 single lines with common reference potential in the data, signal and communication systems: 0-20 mA, 4-20 mA current loop, TTY 4-20 mA, TTY, TTL, V24 (RS232C), high-frequency transmission system.
Specifications:
- ANSI / IEEE C62.41 category: B, C
- Rated operating voltage Un 24 V DC
- Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
- Rated load current at 25°C IL 1 A
- Nom. discharge current (8/20 μs) In 10 kA
- Max. discharge current (8/20 μs) Imax 20 kA
- D1 current impulse (10/350 μs, per line) 2,5 kA
- Voltage protection level Up:
- at In, C2 (8/20 μs, line-line, line-PG) ≤ 55 V
- at C3, 1 kV/µs (line-line, line-PG) ≤ 48 V
- Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019
Applications:
surge protection for 2 pair lines of closed circuit (loops) in the data, signal and communication systems: 4-20 mA current loop, analog/digital communication, RS485, RS422 (V11) interface, high-frequency bus system, 2 wires video transmission system.
Specifications:
- ANSI / IEEE C62.41 category: B, C
- Rated operating voltage Un 24 V DC
- Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
- Rated load current at 25°C IL 1 A
- Nom. discharge current (8/20 μs) In 10 kA
- Max. discharge current (8/20 μs) Imax 20 kA
- D1 current impulse (10/350 μs, per line) 2,5 kA
- Voltage protection level Up:
- at In, C2 (8/20 μs, line-line) ≤ 55 V
- at In, C2 (8/20 μs, line-PG) ≤ 500 V
- at C3, 1 kV/µs (line-line) ≤ 48 V
- at C3, 1 kV/µs (line-PG) ≤ 600 V
- Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019
Applications:
- For protecting low voltage equipment against lightning and surge damages
- For installation in conformity with the lightning protection zones concept at LPZ 0-1
- Designed according to IEC 61643-11:2011
Specifications:
- Category IEC / EN / VDE: class II+III / type 2+3 / C+D
- Max. continuous operating voltage Uc 275 V AC
- Nom. discharge current (8/20 μs) In 10 kA
- Max. discharge current (8/20 μs) Imax 20 kA
- Voltage protection level Up ≤ 1,5 kV
- Max. backup fuse 125 A
Single-use data logger for real-time measurement of temperature, humidity and light. GSM tracking and LTE 4G connectivity for smart logistics worldwide. Free usability of tempmate.®-Cloud for information viewing, reports generation and devices setup. Tempmate-GS2 have 3 models: T, TH and TE, for more information see datasheet.
- Temperature measurement range*: -200…+100 °C
- Relative humidity measurement range*: 0…100 %
- Ambient light measurement range*: 0…10000 lx
- Local storage capacity*: 24200 values for Temperature, Humidity and Light
- Shelf-Life:
- Lithium Battery devices: 12 months (possibility to charge)
- Non-Lithium Battery devices: 6 months (possibility to charge)
- External sensor*: PT100 (cable length: 1m, length of probe is 6cm length, 4 mm in diameter, sensor tip: stainless steel)
- Log interval: User defined: 1 min. to 60 min. (10 min. as standard setting preconfigured)
- Transmission Interval: User defined: 10 min. to 1440 min. (60 min. as standard setting preconfigured)
- Recording Duration:
- Lithium Battery: 90 days (with standard log interval of 10 min. and transmission interval of 240 min.)
- Non Lithium Battery: 60 days (with standard log interval of 10 min. and transmission interval of 240 min.)
- Certifications: CE, EN12830, EMC, RoHS, FCC
- Connectivity: LTE 4G cat 1 with 2G Fallback
- Report Generation: Readable in the Cloud and locally in the device through the USB 2.0 interface
- Location: LBS - GSM Localization
- Recommended Storage Temperature: -15…+25 °C
RSP-E25-... is a Class I+II SPD for surge and lightning protection of low-voltage power supply systems, especially in high-risk exposure areas or building entrances in LPZ 0-2 (IEC 62305-4), protecting against damage caused by direct or nearby lightning strikes; suitable for use in main distribution boards.
- IEC / EN / VDE category: Class I+II / Type 1+2 / B+C
- Application: main distribution boards (MB)
- Power networks: TT, TN-S, TN-C
- Protection modes: L-N, N-PE
- Protective elements: MOV, MOV+GDT
- Enclosure: modular (replaceable module)
- Mechanical status indicator: green/red flag
- Compliant with standards: IEC/EN 61643-11:2011, IEC 60364-4-53, IEC 62305, CE, RoHS
Sensor SKU: 5905309600959 (IP30)
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud** platform or any other third party systems.
- Illuminance measurement range: 0…83000 lux
- Filtering: rejects > 99 % (typically) of IR (matches human eye)
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 1 minutes to 18 hours (configurable by the user)
- Measurement sending interval: 5 minutes to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Possibility to integrate sensor to other third-party systems
- Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
- Case IP30 protection
Aranet T/RH sensor with Radiation Shield is an innovative solution for accurate temperature and humidity measurements in greenhouses exposed to direct sunlight.
- Sensor compatible with base stations: PRO, PRO Plus ir PRO Plus LTE
- Temperature measurement range: -40...+60 °C
- Accuracy: ± 0.3 °C
- Relative humidity measurement range: 0…100 %
- Accuracy: ± 2 %
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Supply: 1xAA battery
- Battery lifetime (20 °C): up to 10 years
- Transmitter operating temperature: -40…+60 °C
- Transmitter protection class: IP65
- 6-range lighting meter AHKF
- Supply: 15...36 VDC (24 VAC for AHKF-U too)
- Sensor: Photodiode in glass casing
- Ranges: 0...500 Lux / 1 kLux / 2 kLux / 5 kLux / 20 kLux / 60 kLux
- Output: 4...20 mA / 0...10 V
- Ambient temperature: -35...70 °C
- Accuracy: < ±10 %
- Temperature accuracy: < ±5 %
- Size: 72 x 64 x 37,8 mm
- Protection type: III (EN 60730)
- Protection class: IP 65 (EN 60529)