The SV600 Fixed Acoustic Imager enables users to continuously detect, locate and visualize unheard and unseen air and gas leaks or changes in sound signatures before they become costly problems.
- 64 MEMS digital microphones for image of leaks
- Powerful processor for onboard real time processing: Sound classification, Frequency filtering, dB values and sound intensity mapping, Event triggering
- Measuring distance: 3…15 m
- Integrated visual light camera
- The SV600 can be mounted on moving applications – including as a Boston Dynamics Spot
- Can be mounted close to any equipment or asset, to any area of the production line, or where human access is restricted or dangerous
- Option for IO support through fieldbus coupler
- Integration: HTTP REST API, Modbus
- Operating temperature: -20…+50 °C
- Protection class: IP54
- Communication and power supply: Ethernet RJ45, POE IEEE 802.3at
- Analog gas detector MC for connection to DGC, MSC, WSB or any compatible gas detector
- Reliable self-monitoring: Integrated watchdog
- Precise signal: 4–20 mA (2–10 V) output for easy system integration
- Addressable digital gas detection system (Sensor-Board SB) for combustible, toxic and refrigerant gases.
- Communication: RS-485 interface for stable and secure system networking
- Precise Detection: High accuracy thanks to digital signal processing
- Easy maintenance with X-Change: Plug & Play systems for fast, convenient service
- Robust Design: Reliable with IP65 even under extreme conditions
- Applications of flue gas analyzer Si-Ca 130: boilers, burners, water heaters and furnaces
- Detectable gases: O2, CO, CO(H2), CO2, NO, Low NO, NOx, Low NOx
- Up to three gas sensors
- CO measurement up to 8000 ppm
- Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation), stack gas velocity
- Color graphical touchscreen for control
- Communication: USB, Bluetooth (mobile App), remote printer
- Measurement storage: 2000 data points + smartphone and PC
- Predictive maintenance with estimated sensor life and calibration reminders
- Protection class: IP42
- Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
- Operating temperature: -5…+45 °C
- Sensor protection by pump stopping
- Warning- and Sensor-Board WSB for digital and analog sensor technology for the precise detection of combustible, toxic and refrigerant gases.
- Versatile alarm function: Alarm and fault relays (30 V)
- Intelligent interfaces: RS-485 interface with DGC or Modbus protocol
- Precise signal transmission: 4–20 mA input and output for reliable communication
- Flexible: Connection of up to 3 sensors (2 digital)
- Extreme long-term stability, quick response time
- Sensor diagnostic with CS service software
- 4...20 mA analogue output, Modbus-RTU (RS-485)
- Suitable to measurement residual moisture, dew point after granulate driers in plastic industry and various gases
Gas cylinder heating jacket prevents frosting and ensures a constant flow rate for laboratory and industrial processes. Equipped with a digital thermostat, it is suitable for various gases and has a durable, lightweight design with quick-release buckles for easy attachment and transport.
- Digital thermostat with a heating range from 0 – 90ºC
- Durable, lightweight design with quick-release buckles
- Suitable for various gases, including SF6, Propane, Nitrogen, Oxygen, BCl3, WF6, and HF
- Silicone impregnated fabric
- Fiberglass insulation
- Teflon heating wire
- 3 meter power cable (no plug)
- Safety Thermostat
- IP40 Protection
The ATEX Gas Bottle Heater series is a safe, efficient, and customizable heating solution for gas bottles located in hazardous areas.
- Nominal voltage: 230 VAC*
- Nominal power: 380W, 850W, 850W (10L, 50L, 79L) or application-specific
- Max. operating temperature: +50/60°C (jacket max. 200°C)
- Temperature class: T6, T5, T4, T3 (depending on temperature setting limiter)
- Electrical connection terminal boxes for network (EX-e) / sensor (EX-i)
- Protection class: IP65/I
- Zones 1/2 (gas); 21/22 (dust)
- Sensors: 2xPt100 (EX-i, EX-e)
- Weight: 6kg, 9.5kg, 10kg (10L, 50L, 79L)
The silicone heater increases flow from LPG cylinders. By adding heat directly to the cylinder, the silicone heater maximizes LPG vaporization, ensuring that your supply lasts longer and works better, even under high demand.
Dimensions: 890mm x 120mm
Voltage: 230V
Wattage: 500W
Compatible with 22kg and 33kg standard size gas bottles
Spring mounted for perfect cylinder fit
Features a 40°C limiter and a 55°C safety fuse with manual reset
Thermal mass flow sensor for compressed air and gases VA 500
- 4...20 mA, pulse and a Modbus RTU (RS 485) interface as standard
- Optional: Interfaces such as Modbus TCP (Ethernet), PoE, M-Bus
- Optional: Bi-directional measurement
- Pressure tight up to 50 bar
- Temperature range up to 110 °C
- Protection class IP65
- Suitable for gas velocities up to 224 Nm/s
- Integrated display for showing the measured values
- Can be used from 1/2" up to 40", larger diameters on request
- Easy installation under pressure
- Settings can be changed via the display
- Main counter reading can be reset via the display
- Calorimetric measuring principle
- Units freely selectable via keys at the display
- Display shows 2 values at the same time, twistable by 180 ° degree
- Integrated Modbus interface enables connection control systems, SCADA
- M-Bus (optional)
- Analog output 4...20 mA
- Pulse output (galvanic isolation)
- High measuring accuracy (ideal for leakage measurement)
- Applications of flue gas analyzer Si-Ca 130: for commercial and residential boilers and water heaters
- Detectable gases: O2, CO, CO2, NO, NOx
- Up to three gas sensors
- CO measurement up to 8000 ppm
- Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation)
- Color display screen with buttons
- Communication: Bluetooth (mobile App), remote printer
- Measurement storage: smartphone
- Predictive maintenance with estimated sensor life and calibration reminders
- Protection class: IP42
- Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
- Operating temperature: -5…+45 °C
- Sensor protection by pump stopping
- Gas measuring, monitoring and warning controller (Multi-Sensor-Controller MSC) for reliable detection of combustible, toxic and refrigerant gases
- Flexible control: 3 relays (SPDT, potential-free, 250 V)
- Intelligent Communication: RS-485 interface with DGC and Modbus protocol
- Precise signal transmission: 4–20 mA input and output for seamless system integration, up to 3 sensors including remote
- Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
- Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
- Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
- Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
- Applications of flue gas analyzer Si-Ca 230: boilers, burners, water heaters, gas and diesel engines, furnaces, industrial kilns, industrial heating systems, incinerators
- Detectable gases: O2, CO (H2 comp.), CO2, NO, Low NO, NO2, Low NO2, NOx, Low NOx, SO2, Low SO2, CxHy (HC), H2S
- Up to six gas sensors
- CO measurement up to 50 000 ppm
- Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation), stack gas velocity
- Color graphical touchscreen for control
- Communication: USB, Bluetooth (mobile App), remote printer
- Measurement storage: 2000 data points + smartphone and PC
- Predictive maintenance with estimated sensor life and calibration reminders
- Protection class: IP42
- Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
- Operating temperature: -5…+45 °C
- Sensor protection by pump stopping
- Įėjimas: Pt100, Pt1000, 0…4000 Ω, TC (E, J, K, N, R, S), -75…310 mV, -10…10 V, -24…24 mA, potenciometras
- Relinė išėjimas: 1 x NO kontaktas, apkrovos galia 6 A / 250 V AC; 6 A / 30 V DC
- Skaitmeninis išėjimas: RS-485 / MODBUS RTU
- Išorinio įrenginio maitinimas: 24 V DC / 24 mA
- Matematinės funkcijos matavimo reikšmės konvertavimui
- Dviejų eilučių LCD ekranas (1 eilutė – 6 skaitmenys, 2 eilutė – 5 skaitmenys)
- Apsaugos klasė: priekio – IP65 / galo – IP10
- Darbinė temperatūra: -20...23...60 °C
- Maitinimas: 40…253 V AC / 20…300 V DC
- Measuring range: -1…100 bar (see datasheet)
- Basic accuracy 0,5% of range
- Output: 4…20 mA
- Process connection: G 1/2“, G 1/2“, G 1/2“ Flush membrane, G 1/4“, G 1/4“, 1/2“ NPT, 1/4“ NPT, Tri-Clamp (Ø 50,5) Flush membrane
- Operating temperature: -20…+85 / 200 °C (see datasheet)
- Stainless steel housing and diaphragm material
- Protection class: IP67 / IP68
- Volumetric flow and air velocity meter with linear analogue output in control quality (0...10 V & 4...20 mA) and switch
- Suitable for media temperatures up to 350°C
- Measured value display by means of LCD and LED
- Freely scalable measuring range m/s, m³/h, l/min
- Sensitive and fast airflow detection up to 30 m/s
- Exemplary areas of application: Measurement and control of air flows, building services, PLC, filter monitoring, extraction and extrusion systems, exhaust gases and test benches