Moisture measuring of sand, minerals, clay, grain, foodstuffs, sawdust, ores, sewage sludge. During operation, the sensor requires nothing but a power supply and a display or a controller that can receive the measurement signal. The BMMS sensor is designed for applications in which no multi-part systems are to be used but still the highest precision is required. Due to the in-process calibration, all potential interference from the sensor installation is directly compensated for.
Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.
- Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
- Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
- CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
- Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
- Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
- Air quality (VOC) measuring range: 0…100 %
- Data output: galvanically separated RS-485 Modbus RTU interface
- Variants: with / without LCD display
- One sensor covers about 30 m² of room area
- Power supply: 24 V ac/dc (200 mA)
- Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
- Fuel sawdust moisture meter WTR-2A is designed to measure moisture of sawdust, scobs, wood shavings, slivers and other finely crumbled wood waste used as fuel
- Range: 35...85 %
- Sample volume: 120 cm2
- Measuring sample: 0,2 MPa
Automatic portable solid state particle (dust) meter EMIOTEST 3114 is designed for periodic solid state particle concentration measurement in closed channels, i.e. flue gas, and perform other functions:
- Periodic measurement of solid state particle concentration in stationary sources of emission
- Solid state particle concentration measurement in gasses
- Testing of dust removal equipment
- Gas flow rate measurement
- Calibration and periodic control of automatic systems (AMS) by measuring the emission and mass stream of dust
- Dioxins, furans, PAH, mercury concentration measurement
- Heavy meal, HCL, HF concentration measurement
RFLS-53 can be used in demanding applications to indicate powder, dust and hygroscopic materials and can replace mechanical rotary level switches or standard capacitive level switches.
- The RFLS-53 uses the principle of high-frequency capacitive measurement
- It responds to the mass of the material and ignores deposits and material residues on the measuring part
- For demanding applications to indicate powder, dust and hygroscopic materials
- The sensor is available in several versions with different types of outputs and electrical connections
- The RFLS-53 fully replaces the older CLS-53, its electrical connection is different for the 230 VAC version (3 wires)
Industrial IoT module TCW242 for remote real-time monitoring and control of industrial equipment, facilities, production lines, renewable energy systems, greenhouses and water stations
- Web-based configuration and control with password protection
- 4 digital inputs for dry contacts
- 4 analog inputs with 0-10V and 0-20mA options
- 4 relays with normally open/normally closed contacts
- RS-485 interface for MODBUS RTU sensors. Up to 24 sensors (registers)
- Monitor up to 24 channels
- Set up to 24 independent alarms
- SNMPv3 protocol support
- Alarm notifications via SNMP traps
- NTP protocol support
- HTTP API commands
- 4 schedules for real-time control of relay outputs
- Custom logical functions
- Secured email transfer with TLS 1.0, TLS 1.1, and TLS 1.2 support
- Data logging capacity for up to 70,000 records
- Dynamic DNS support for DynDNS, No-IP, and DNS-O-Matic providers
- Periodical HTTP / HTTPS Post of XML / JSON status files for client-server systems
- MODBUS TCP / IP protocol support
- MQTT 3.1.1 protocol support
- Rugged DIN-Rail / wall-mountable enclosure
- Operating temperature range: -20…+55 °C
- Industrial pressure transmitter’s measuring principle: Thin-film-on-steel
- Applications: hydraulics, industrial applications, machine tools
- 5-fold overpressure resistance
- Measuring range: 0...2.5 / 0...700 bar // 0...30 / 0...10000 psi
- Measuring accuracy at 25 °C typ.: ± 0.5 % FS typ. ± 0.3 % FS typ
- Output signal: 4...20 mA, 0...5 VDC, 0.5...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
- Ambient temperature: -40°C…+125°C
- Designed to measure the moisture of wood, sawdust, shavings, chips, straws and hay
- Moisture measurement method: resistive
- Sawdust moisture range: 8...30 %
- Hay moisture range: 8...25 %
- Sample size: 120 cm3
- Sample compression pressure: 0,2 MPa
The sensor consists of a replaceable insert, a ceramic protective tube (thermowell) and an aluminium connection head (depends on model) where a programmable temperature transmitter with 4-20 mA output can be installed.
- Temperature measuring range: 0… +1800 °C
- Usable areas: Blast furnaces, regenerating air heaters, industrial heating installations, heat generation
- Standard protection tube material: mullite C610 (Al2O3 60%), Ceramic C799 (99.7% Al2O3)
- Gastight process connection: (to 0.1 MPa / 1 bar)
- Optionally the head can be installed with a local temperature display (DANWdie-LED)
- ATEX and EAC Ex versions
- For specific model design please look picture below ↓: TT438, TT440, TT441, TT442, TT443, TT444
LoRa-Log-Meter is a wireless data logging system based on LoRaWAN communication technology. It is designed to collect data from LoRaWAN devices such as sensors, interfaces, and meters that monitor environmental, technological and industrial process parameters and transmit data packets to a LoRaWAN gateway.
Collected data is processed and stored in the gateway, and can be accessed via a web browser.
- Compatible with Synetica and others LoRaWAN devices: analog inputs (4–20 mA, 0–20 mA, 0–10 V), temperature sensors, pulse inputs (SO, NC/NO contacts) and others
- Individual alarm notifications based on specific sensors or contacts
- Alarm notifications via email and SMS
- Logging and review of errors and communication issues
- Remote access to the LoRa-Log-Meter system via 4G LTE, Wi-Fi, or LAN (Ethernet)
- Dynamic data visualization in graph (curve) format via a web browser
- Data export in CSV and PNG formats
- Password-protected user interface
- No subscription required for the gateway or sensors
- Remote configuration of data transmission intervals for devices via a web browser
- Communication range from sensor to gateway:
- 15 km Outdoors (in plain sight)
- 50–200 meters indoors or up to 7–8 walls*
- LoRaWAN devices powered by: 2 × AA 3.6 V lithium batteries or 5 V USB power
The sensor SVT200-T require to be used with Broadsens's wireless gateway and analysis software BroadVibra.
- Temperature measurement range: -40…+105 °C
- Accuracy / Resolution: ±0,3 °C / 0,01 °C
- Measurement and transmission interval: 15 seconds (Selectable: 1…60 s)
- Power supply: CR2450W Battery. Up to 10 years in continuous usage
- Wireless data transmission (BLE): 2.4GHz; up to 100 m in line of sight
- Certificates: FCC, IC, CE(EU), TELEC, KCC, NCC, WPC, RCM certified
- Mounting: Glue / epoxy. Screw mounting option available for SVT200-T-F case
- Protection class: IP68 waterproof
- Size / Weight: 39 mm x 14 mm / 30 g
The sensor SVT300-V require to be used with Broadsens's wireless gateway and advanced vibration analysis software BroadVibra.
- Alarm sent out in 0,5 second when accident detected
- Acceleration range: 2g to 16g auto adjustment
- Acceleration sampling rate: Low speed & 6.4kHz sampling rate dynamic adjustment based on vibration level
- Acceleration resolution: 16 bit
- -3dB bandwidth (Hz): x,y,z axis: 0.1Hz to 3.2kHz
- Temperature measurement range: -40…+125 °C
- Wireless data transmission (BLE): 2.4GHz; up to 300 m in open space. FCC / IC approved
- Battery life: 3…4 (12-hour running machine a day); 14250 battery, 1200 mAh
- Mounting: M6 screw hole or two screw-hole case
- Working temperature: -55…+85 °C; IP68 (IP69K optional)
- Explosive atmosphere: Intrinsic safe. ATEX & IECEx: Ex ia IIC T4 Ga; Ex ia IIIC T135 Da
- Capacitive moisture measurement
- Temperature range of measuring material: 4...50 °C
- Direct measured values transfer from the sensor
- Calibration is made directly at sensor, beyond the process
- Capacitive moisture measurement
- Up to 16 sensors per signal processing unit
- Temperature range of measuring material: 4...80 °C
- Measured value transfer: Profibus DP or analogue standard signal (e.g. 4...20 mA) optional
- Continuous measurement or batch operation