This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Поиск

Критерии поиска

Товары, соответствующие критериям поиска

Показать:
Сортировка:
  • To measure air and neutral gases pressure in range -100...100 Pa
  • Solenoid valve for auto-calibration: frequency 1…60 min
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -100...100 Pa
  • Accuracy: ± 1 % of reading ± 2 Pa
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output: 0-10 V and 4-20 mA
  • Overpressure tolerated: 21 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply: 24 V AC / V DC
  • To measure air and neutral gases pressure in range -1000...1000 Pa
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -1000...1000 Pa
  • Accuracy: ± 1.5 % of reading ± 3 Pa
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA: 4-20 mA
  • Overpressure tolerated: 21 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
  • To measure air and neutral gases pressure in range -2000...2000 mbar
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -2000...2000 mbar
  • Accuracy: ± 1.5 % of reading ± 3 mbar
  • Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
  • Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 4100 mbar
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
  • To measure air and neutral gases pressure in range -500...500 mbar
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -500...500 mbar
  • Accuracy: ± 1.5 % of reading ± 3 mbar
  • Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
  • Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 1400 mbar
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
  • Temperature measurement range: -35…+80 ºC
  • Humidity measurement range: 0…100 % RH
  • Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
  • Output: Modbus RTU
  • Allowed overpressure/ bellow: ± 50 kPa
  • Operating temperature: 24 VAC / 15…35 VDC
  • Protection class: IP 65
  • Measuring function: differential pressure, volume flow
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: switchable 0-10 V/ 4 ... 20 mA (via DIP switches)
  • Allowed overpressure: 50 kPA
  • Supply: 24 VAC
  • Medium: clear air, non-aggressive, non-combustible gases
  • Protection class: IP 54
  • Pressure measurement range: 0...1000 Pa, 0...5000 Pa
  • Volume flow, differential pressure measurement, filter monitoring and liquid level detection
  • Volume flow: 10...100% [m3/s][m3/min][m3/h]l/s][l/min][l/h]
  • Filter monitoring: 10...100%
  • Liquid level detection: 0 – 8...14 cm or 0 – 39...72 cm (depends on pressure range)
  • Output: 0 – 10 V, 1 x changeover contact
  • Measurement element: piezoresistive sensor
  • Application: in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spay booths, in large scale catering facilities, for filter monitoring and level measurement or for triggering frequency converters.
  • Medium: clean air, non-aggressive, non-combustible gasses

 

Sensor SKU: 5905309601475 (IP30)

Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.

  • Differential pressure measurement range: +/- 500 Pa, accuracy: up to 1 Pa
  • Length of measuring tubes: 1 m (another lengths on request)
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh, 3xAA battery (replaceable)
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -15…+70 °C / 0…99 %
  • Case IP30 protection

Sensor SKU: 5906660327820 (IP30)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.

  • Differential pressure measurement range: +/- 500 Pa, accuracy: up to 1 Pa
  • Length of measuring tubes: 1 m (another lengths on request)
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Case IP30 protection

Measure the difference in air pressure between two points as needed in HVAC (air filter condition), building automation and Pharma. This device, belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • Pressure range: ± 500 Pa
  • Resolution: 0,02 Pa
  • Accuracy: ± (0.10 Pa + 3 % of reading)
  • Long term drift: 0,05 Pa / year
  • Response time: (99 %) <1 s
  • Calibrated for Air, N2
  • Gas compatibility: Air, N2, O2
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply: 1 x AA battery
  • Battery lifetime (20 °C): up to 10 years
  • Operating temperature: -40…60 °C
  • Protection class: IP65
  • To measure air and neutral gases pressure in range -10 000...10 000 Pa
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -10 000...10 000 Pa
  • Accuracy: ± 1.5 % of reading ± 3 mmH2O
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output (Optional):0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 69 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
Loading...