- Voltage being detected in one of two ranges: 85...250 VAC or 170...250 VAC (settable by jumper)
- Galvanic isolation between the input voltage and output (OC)
- Low temperature drift
- Supplied by detected voltage
- Warranty: 3 years
The SV600 Fixed Acoustic Imager enables users to continuously detect, locate and visualize unheard and unseen air and gas leaks or changes in sound signatures before they become costly problems.
- 64 MEMS digital microphones for image of leaks
- Powerful processor for onboard real time processing: Sound classification, Frequency filtering, dB values and sound intensity mapping, Event triggering
- Measuring distance: 3…15 m
- Integrated visual light camera
- The SV600 can be mounted on moving applications – including as a Boston Dynamics Spot
- Can be mounted close to any equipment or asset, to any area of the production line, or where human access is restricted or dangerous
- Option for IO support through fieldbus coupler
- Integration: HTTP REST API, Modbus
- Operating temperature: -20…+50 °C
- Protection class: IP54
- Communication and power supply: Ethernet RJ45, POE IEEE 802.3at
- Analog gas detector MC for connection to DGC, MSC, WSB or any compatible gas detector
- Reliable self-monitoring: Integrated watchdog
- Precise signal: 4–20 mA (2–10 V) output for easy system integration
Stable long-life optical NDIR gas sensor
Range 0...10 000/50 000 ppm CO2
Resolution 1/100 ppm for 10K/50K range CO2
Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
Remote probe option
- Stable long-life optical NDIR gas sensor
- Range 400...5 000/10 000/50 000 ppm CO2
- Resolution 10 ppm CO2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Remote probe option
- NDIR gas sensor
- Range: 0...10 000 ppm CO2
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: 0...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC as options
- Stable long-life electrochemical gas sensor
- Range 0....1000 ppm CO
- Resolution 1 ppm CO
- Default alarms at 25 ppm / 35 ppm CO
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Stable long-life electrochemical gas sensor
- Range: standard 0....200 ppm CO, maximal 0...1000 ppm CO
- Resolution 1 ppm CO
- Default alarms at 25 ppm / 125 ppm CO
- Outputs 2 x relays with switch-over contacts
- Visual and acoustic alarms
- Long-life electrochemical cell
- Range 0....1000 ppm CO
- Resolution 1 ppm CO
- Outputs 4...20 mA / 0...10 V, RS-485
- Stable long-life electrochemical gas sensor
- Range 0....200 ppm CO
- Resolution 1 ppm CO
- Outputs 2 x relays with switch-over contacts
- UART digital interface
- Visual and acoustic alarms
- Magnetic key switching
- Electrochemical gas sensor
- Range:
- -- 0…300 ppm CO
- -- 0...1000 ppm CO
- Resolution: 1 ppm CO
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Addressable digital gas detection system (Sensor-Board SB) for combustible, toxic and refrigerant gases.
- Communication: RS-485 interface for stable and secure system networking
- Precise Detection: High accuracy thanks to digital signal processing
- Easy maintenance with X-Change: Plug & Play systems for fast, convenient service
- Robust Design: Reliable with IP65 even under extreme conditions
- Stable long-life electrochemical cell
- Range 0...20 ppm Cl2
- Resolution 0,02 ppm Cl2
- Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 0,5 ppm/1 ppm Cl2
- Remote probe option
- Stable long-life electrochemical cell
- Range 0...20 ppm Cl2
- Resolution 0,02 ppm Cl2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Remote probe option
- Electrochemical gas sensor
- Range: 0...10 ppm Cl2
- Resolution: 0,1 ppm Cl2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC (default), 24 VAC or 90...265 VAC
- For methane, butane, propane and hydrogen
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL
- Resolution 0,1 % LEL
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarms at 20 / 50 % LEL
- For methane, LPG, hydrogen and acetylene
- Can be calibrated for metane, propane and butane
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL
- Resolution 0,1 % LEL
- Outputs 2 x relays with switch-over contacts
- Default alarms at 10 / 25 % LEL
- For methane, butane, propane and hydrogen
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL
- Resolution 0,1 % LEL
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- For methane, LPG, hydrogen and acetylene
- Can be calibrated for methane, butane, propane, acetylene and hydrogen
- Stable long-life metal-oxide gas sensor
- Range: 0...100 % LEL
- Resolution: 0,1 % LEL
- Outputs 2 x relays with switch-over contacts
- Default alarms set-points 10 / 25 % LEL
- UART digital interface
- Alarms: blinking LED, 85 dB buzzer
- Metal-oxide gas sensor
- Detected gases: hydrogen, methane, acetylene, propane, butane
- Standard calibration: methane
- Range: 0...100 % LEL
- Resolution: 0,1 % LEL
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+70 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Warning- and Sensor-Board WSB for digital and analog sensor technology for the precise detection of combustible, toxic and refrigerant gases.
- Versatile alarm function: Alarm and fault relays (30 V)
- Intelligent interfaces: RS-485 interface with DGC or Modbus protocol
- Precise signal transmission: 4–20 mA input and output for reliable communication
- Flexible: Connection of up to 3 sensors (2 digital)
- Stable long-life electrochemical gas sensor
- Range 0...10 / 0...200 / 0...1500 ppm C2H4
- Resolution 0,1 / 1 / 5 ppm C2H4
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Stable long-life electrochemical gas sensor
- Range 0...10 / 0...200 / 0...1500 ppm C2H4
- Resolution 0,1 / 1 / 5 ppm C2H4
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...10 / 0...200 / 0...1500 ppm C2H4
- Resolution: 0,1 / 1 / 1 ppm C2H4
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Electrochemical gas sensor
- Range: 0...20 / 0...100 ppm C2H4O
- Resolution: 0,1 / 1 / 5 ppm C2H4O
- Analog output: 2 x 4...20 mA / 0a...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Suitable for ATEX Zones 2 and 22
- Electrochemical gas sensor
- Range: 0...100, 0...300, 0...1000, 0...5000 ppm NH3
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life pellistor (catalytic bead) sensor
- Range: 0...15% vol. (0…100% LEL)
- Resolution: 0.1% vol. or 1% LEL
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -10...+50 °C
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life photoacoustic or optical NDIR sensor
- Range: 0...10 000 ppm / 0...40 000 ppm / 0...5 % vol (0...100 % on request)
- Resolution: 1 ppm / 10 ppm / 0.01 % vol. CO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+60 °C; 0….100 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...300 or 0...1000 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Detected gases: hydrogen, methane, acetylene, propane, butane
- Default calibration: methane CH4
- Stable long-life metal-oxide / pellistor sensor
- Range: 0...100% LEL
- Resolution: 0,1 / 1 % LEL
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...10 / 0...200 / 0...1500 ppm
- Resolution: 0,1 / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C; up to 100 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Detectable gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234ze and similar
- Stable long-life metal-oxide sensor
- Range: 0…1000 / 0…2500 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -30...+60 °C; < 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...100 ppm, 0...2000 ppm H2S
- Resolution: 1 ppm H2S
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C; 15…90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life metal-oxide / pellistor sensor
- Range: 0...100% LEL CH4
- Resolution: 0,1 / 1 % LEL CH4
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0…250 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -30...+50 °C; 15…90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life optical NDIR sensor
- Range: 0…1000 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -20...+50 °C; 0…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...25 % vol O2
- Resolution: 0,01 % vol O2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+60 °C; 5…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Highly sensitive Photo Ionization Detector (PID) sensor
- Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
- Default calibration: Isobutylene
- Range: 0…40 / 0…200 ppm isobutylene
- Resolution: 0,01 / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life metal-oxide sensor
- Detectable gases: acetone, ethanol, toluene, xylene etc.
- Default calibration: toluene
- Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
- Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Gas measuring, monitoring and warning controller (Multi-Sensor-Controller MSC) for reliable detection of combustible, toxic and refrigerant gases
- Flexible control: 3 relays (SPDT, potential-free, 250 V)
- Intelligent Communication: RS-485 interface with DGC and Modbus protocol
- Precise signal transmission: 4–20 mA input and output for seamless system integration, up to 3 sensors including remote
- Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
- Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
- Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
- Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
- Long-life metal-oxide gas sensor
- Range 0...100 % LEL H2
- Resolution 0,1 % LEL H2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor options
- Stable long-life electrochemical gas sensor
- Range 0...100 / 0...1000 ppm H2S
- Resolution 0,1 / 1 ppm H2S
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 10 / 20 ppm H2S
- Stable long-life electrochemical gas sensor
- Range 0...100 / 0...1000 ppm H2S
- Resolution 0,1 / 1 ppm H2S
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor option
- Electrochemical gas sensor
- Range: 0...100 / 0...2000 ppm H2S
- Resolution: 0,1 / 1 ppm H2S
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
LCC series laser edge detectors (laser copy counters) primarily are designed for detecting and counting magazines or single sheets in imbricated arrangement. Furthermore, these laser sensors are suitable for counting corrugated cardboard boxes, laminates, as well as for counting the number of folds of paper filters (air filters).
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL (0...5 % vol) CH4
- Resolution 0,1 % LEL (50 ppm) CH4
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 20 / 50 % LEL CH4
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL CH4
- Resolution 0,1 % LEL CH4
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 20 / 50 % LEL CH4
- Visual and acoustic alarms
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL (0...5 % vol) CH4
- Resolution 0,1 % LEL (50 ppm) CH4
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor options
- Metal-oxide gas sensor
- Range: 0...100% LEL (0...5 %) CH4
- Resolution: 0,1 % LEL (50 ppm) CH4
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+70 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC