This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Поиск

Критерии поиска

Товары, соответствующие критериям поиска

Показать:
Сортировка:
  • Input voltage range: 0…264 Vac or 0…370 Vdc
  • Input frequency: 0…60 Hz
  • Input resistance: >2.4 MOhm
  • Output: Modbus RTU – RS-485
  • Resolution: 24 bits with DSP processing
  • True RMS measurement
  • Working isolation voltage: 1500 Vrms
  • Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
  • DIN rail mounting
  • Power supply: 5…28 Vdc
  • Warranty: 3 years

The VA700 Loop Calibrator is a versatile source and measurement tool. It is designed to measure or output a 0 to 24 mA DC current loop and 0 to 20 V DC voltage. The calibrator cannot measure and source simultaneously.

  • Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
  • Storage temperature: -40℃ to 60℃
  • Operating temperature: -10℃ to 55℃
  • Operating altitude: Up to 3000 meters
  • Temperature coefficient: ±0.005% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
  • Relative humidity:
    • 95% up to 30℃
    • 75% up to 40℃
    • 45% up to 50℃
    • 35% up to 55℃
  • Shock: Random 2g, 5Hz to 500Hz
  • Safety: 1 meter drop test
  • Power requirements: 6 x AAA batteries
  • Size: 204mm (L) x 99mm (W) x 46mm (H)
  • Weight: 460g (including battery)

Portable calibrator for DC voltage and current.

 

Purpose:

  • Calibration and verification of temperature measurement equipment
  • Measurement and control equipment monitoring
  • Current loop circuit monitoring
  • 10 time functions. With control signal and without additional signal
  • 10 time ranges. Ranging from 0,1 sec. to 30 hours
  • Operating voltage: 12…240 V AC / DC
  • Operating power: < 4 VA
  • Mounting on DIN rail
  • Operating temperature: -20…+55 °C
  • Transducer for DC current and voltage into other DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • Solves grounding problem in meshed signal networks
  • User selectable type and range of input
Wireless current sensor 4…20mA with PSU, TDSCT102, TDSCT202 Hовый

Measures analog signal of a 3rd party sensor. Provides 24 or 12 VDC power for a 3rd party sensor using the built-in power supply unit (PSU).

  • Sensor compatible with base stations: PRO, PRO Plus ir PRO Plus LTE
  • Current measurement range: 0...30 mA
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Operating temperature: -30...+80 °C
  • Power supply: 85…265 VAC
    • 1 x AA battery is for to notify user in case of external
  • Protection class: IP67
Wireless voltage sensor 0-10V with PSU, TDSVT102, TDSVT202 Hовый

Measures analog signal of a 3rd party sensor. Provides 24 or 12 VDC power for a 3rd party sensor using the built-in power supply unit (PSU).

  • Sensor compatible with base stations: PRO, PRO Plus ir PRO Plus LTE
  • Voltage measurement range: -32...32 VDC
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Operating temperature: -30...+80 °C
  • Power supply: 85…265 VAC
    • 1 x AA battery is for to notify user in case of external
  • Protection class: IP67
Loading...